Gianni Industries EB200NVGL Installation guide

Type
Installation guide
EB180/185
EB190/195
EB220
EB262
EB300
EB400
EB220
EB262
EB200NVGL
EB300VGL
EB195VGL
Copyright
P-MU-EB-S Ver.J Published on 2011.08.22
© Gianni Industries, Inc. All Rights Reserved.
0,3,6,9 seconds
Default: 1 second
Note: BSS= Bond sensor status (Locked or unlocked) ; DPS= Door position status (Door open or closed)
Installation on Frameless Glass Door / Wall
Surface mount (narrow frame)
Standard frame (1.75” frame) mortise mount
With UBK-262 for Frameless Glass door
Pull in:
0.9A/12VDC
0.4A/24VDC
Holding:
0.15A/12VDC
0.1A/24VDC
Pull in:
0.9A/12VDC
0.45A/24VDC
Holding:
0.15A/12VDC
0.1A/24VDC
Pull in:
0.9A/12VDC
Holding:
0.3A/12VDC
Pull in:
0.9A/12VDC
Holding:
0.3A/12VDC
Pull in:
0.9A/12VDC
Holding:
0.3A/12VDC
Pull in:
0.9A/12VDC
Holding:
0.3A/12VDC
EB180/185
EB190/195
The C-Bracket can be
use d if the doo r le af
frame is concave.
Ensure the width and depth of the door frame, door leaf (hollow
metal door) are enough to install the lock body. Also check if it is
possible to place the wires inside the door frame.
Ensure the double action door swings back to correct position
after use to make sure the electric dropbolt locks up quickly.
Therefore the hinge of the double action door is very important.
Check if the regulated power supply or controller can provide
the current draw (pull in: 0.9A/12VDC , holding: 0.3A/12VDC)
and that the voltage can be maintained during operation under
all circumstances.
General Installation Instructions:
Copyright
P-MU-EB-S Ver.J Published on 2011.08.22
© Gianni Industries, Inc. All Rights Reserved.
Adjustable Position Ball
EB300VGL for Frameless Glass Door/ Wall
EB195VGL for Frameless Glass Door/ Wall
EB300-Surface Mount
EB400-Surface Mount
Installation:
1.Clean the glass before installing , strike the face place on the glass
(indoor)
2.The interior width of VGL bracket is 14mm , spacer thickness is 1 mm.
3.Stick the spacer in accordance to the glass thickness (10~13mm)
4.Put silicone inside the VGL bracket to hold firmly.
5.Lock the Sunken screw.
6.Use allen wrench to install the cover.
Caution:
1.Spacers are installed indoor.
2.Lock the sunken screws slightly or it will break the glass.
Copyright
P-MU-EB-S Ver.J Published on 2011.08.22
© Gianni Industries, Inc. All Rights Reserved.
T
he th
ick
n
ess o
f g
l
as
s
is 1
0~1
3m
m
.
EB400
T
h
e th
ick
n
ess o
f g
la
s
s
i
s 1
0
~13
m
m.
Energy saving design: All Electric Dropbolt
Auto-detective circuitry: Unique self-detective logical circuitry
designed to retract the bolt until the door is properly closed.
After relock time delay for the Electric Dropbolt activates the pull
in motion, the motion will not stop until theDropbolt locks the door
properly.
When the sensor magnet in the Strike Plate detects the reed in the
lock body, the Dropbolt projects immediately.
Under the energy saving design, after the dropbolt completely
locks, the current draw will drop from high pull in current to low,
continuingholding state.
The reed in the lock body will automatically switches off at the
same time when the dropbolt is locked.
Dropbolt does not activate when
the door closed.
Low in voltage / current.
Low in voltage / current.
Make sure the output voltage and the current
draw are large enough for pull in 0.9A/12VDC.
Make sure the output voltage and the current
draw are large enough for pull in 0.9A/12VDC.
Lock and unlock sensor rating
1A/24VDC
Door position status rating
0.5A/20VDC
Lock and unlock sensor rating
1A/24VDC
Door position status rating
0.5A/20VDC
Door opened= N.C.
Door closed=N.O.
Copyright
P-MU-EB-S Ver.J Published on 2011.08.22
© Gianni Industries, Inc. All Rights Reserved.
Make sure that the “+” and “-” wires are connected correctly. Failure to observe polarity will result in a short circuit and is not covered
by product warranty.
Caution:
0 second 3 seconds
6 seconds
0 second 3 seconds
6 seconds
0 second 3 seconds
6 seconds
Adjust the door closer or the door hinge for the
door leaf to close the door in the correct
position.
If solution 1. doesnt work, it is recommended
to change the double action door to single
action door.
Release or sway the door to release the latch
bolt to open the door.
If solution 1. doesnt work, it is recommended
to change the double action door to single
action door.