Ditek DTK-VM12RM is a high-performance surge protective device designed to safeguard sensitive electronic equipment from voltage spikes and surges. It offers versatile protection for analog, digital, and high-speed data circuits terminating at a single point using RJ45 or BNC interfaces. The modular design allows for easy installation and replacement of individual surge modules, providing flexibility in configuring protection for up to 12 ports. With proper grounding and installation, the DTK-VM12RM ensures maximum protection for valuable electronic devices in various applications.

Ditek DTK-VM12RM is a high-performance surge protective device designed to safeguard sensitive electronic equipment from voltage spikes and surges. It offers versatile protection for analog, digital, and high-speed data circuits terminating at a single point using RJ45 or BNC interfaces. The modular design allows for easy installation and replacement of individual surge modules, providing flexibility in configuring protection for up to 12 ports. With proper grounding and installation, the DTK-VM12RM ensures maximum protection for valuable electronic devices in various applications.

INSTALL INSTRUCTIONS
DTK-VM12RM
DITEK Technical Support Available 24/7
1-888-472-6100 www.diteksurgeprotection.com
DITEK Corporation
ONE DITEK CENTER
1720 Starkey Road
Largo, FL 33771
INSTALLATION
This Surge Protective Device (SPD) is a high performance device, designed to provide protection
for sensitive electronic loads where the SPD is directly connected to the elctronic device.
Maximum protection will only be achieved if the SPD is properly installed and grounded.
Please read and follow all instructions carefully.
NOTICE: This SPD should be installed by a licensed contractor in accordance with the National
and Local Electrical Codes and the following instructions.
APPLICATION
Surge suppression for analog, digital, and high speed data circuits all terminating at the same point of
use using RJ45 or BNC interfaces. This device is designed for *rack mount, *back plane mount or on a
*hinged wall mount bracket. This design allows you to mix and match up to 12 ports per face plate.
SURGE MODULE INSTALLATION INSTRUCTIONS:
Versa Module Series
1. Lay faceplate face down on a flat surface with the ground lug on your left hand side.
2. Select the desired module and its desired positon number (1-12)
3. Remove hardware kit and surge module from plastic bag.
4. Place the silver spacer onto the threaded standoff.
5. Place split (lock) washer on top of silver standoff.
6. Place surge module pc board over threaded standoff with the 4 solder points at the top right hand
corner of the surge module pc board. Make sure the connectors and threaded standoff line up with
their perspective holes and seat properly.
7. Place 2nd split (lock) washer over threaded standoff.
8. Place the hex-nut over the threaded standoff. using a hex socket, tork the nut
to 10 Inch Pounds Maximum.
9. Turn the DTK-VM12RM over.
10.Use the circuit identification label supplied with your hardware kit and apply to the front face of your
DTK-VM12RM under that surge module’s corresponding port number.
11. Repeat these steps for each additional surge module or to replace a module that has self-sacrificed.
DTK-VMBNC Module Installation:
Follow the same procedure as above, adding the black flat washers and retaining nuts to the BNC
connectors where they protrude through the DTK-VM12RM face plate. Fasten the nuts until snug.
WIRING INSTRUCTIONS:
Caution
: Measure all voltages to insure applied voltage does not exceed the voltage rating of the
module. Improper installation voids the warranty.
This unit must be connected in series with the field wiring and the equipment to be protected.
1. Connect a #10 AWG minimum ground wire to the ground lug on back of face plate and connect
this to an appropriate ground point.
2. Mount this device using your preferred method of install*.
3. Connect the incoming wires to the “IN” connector.
4. Connect a 3’ minimum CAT5e patch cable for Ethernet connections, and a 3’ minimum BNC patch
cable for Coaxial connections, from the “OUT” connector to the equipment to be protected.
Note: Always have one common ground per system to eliminate the possibility of a differential in
ground potentials.
Ground Resistance Rule: Max ground resistance is 25 Ohms, 5 Ohms or less is optimum.
This cannot be an assumed value and must be measured to assure proper grounding.
DTK-RM12FPPLUG Installation/Removal:
1. Press square plug into unused port until it seats completely.
2. To remove plug, tap the plug out from the back side of faceplate until it is freed.
Doc # INT-100167-001
Part No. 191598 Rev. 2
Drawn By: B. Aycock 5/18/18
Approved By: R. Mitchell 7/2/18
INSTALL INSTRUCTIONS
DTK-VM12FP
DITEK Technical Support Available 24/7
1-888-472-6100 www.diteksurgeprotection.com
DITEK Corporation
ONE DITEK CENTER
1720 Starkey Road
Largo, FL 33771
INSTALLATION
Illustrations Page
Ground
wire
10 AWG Min.
EQUIPMENT
Output Patch Cables
Allow 3 ft. minimum
Length to Equip
Input Patch Cables
Doc # INT-100167-001
Part No. 191598 Rev. 2
Drawn By: B. Aycock 5/18/18
Approved By: R. Mitchell 7/2/18
Ground Lug
4 Solder Points
Cut Away View Of
Rear Of VM12RM
Faceplate
  • Page 1 1
  • Page 2 2

Ditek DTK-VM12RM Installation guide

Type
Installation guide

Ditek DTK-VM12RM is a high-performance surge protective device designed to safeguard sensitive electronic equipment from voltage spikes and surges. It offers versatile protection for analog, digital, and high-speed data circuits terminating at a single point using RJ45 or BNC interfaces. The modular design allows for easy installation and replacement of individual surge modules, providing flexibility in configuring protection for up to 12 ports. With proper grounding and installation, the DTK-VM12RM ensures maximum protection for valuable electronic devices in various applications.