Chloride SoftGlo LED Night Light is an energy-efficient and long-lasting lighting solution for indoor applications. It features an expandable hanger bar that allows for easy mounting between studs on either 16" or 24" centers. The three knockout holes provided in the back box offer flexibility for wiring, and the quick disconnect connector simplifies faceplate installation. With its flush mounting design, the night light seamlessly integrates with your wall décor.

Chloride SoftGlo LED Night Light is an energy-efficient and long-lasting lighting solution for indoor applications. It features an expandable hanger bar that allows for easy mounting between studs on either 16" or 24" centers. The three knockout holes provided in the back box offer flexibility for wiring, and the quick disconnect connector simplifies faceplate installation. With its flush mounting design, the night light seamlessly integrates with your wall décor.

INSTALLATION INSTRUCTIONS
SoftGlo
LED Recessed Night Light
Series: SO
CAUTION! – READ THIS FIRST --- IMPORTANT SAFETY INSTRUCTIONS
* Carefully read the instructions pertaining to your
xture.IFYOUHAVEANYQUESTIONS
REGARDINGTHEPROPERINSTALLATION 
ORLOCALCODES,CONSULTAQUALIFIED
ELECTRICIAN.
* Injurytopersonsanddamagetothexture
and/ormountingsurfacemayresultifthexture
ispulledfromthesurface.Toreducethe
likelihoodofsuchinjuryordamage,mountonly
onasurfacethatismechanicallysound.
* Thisxtureisintendedforconnectiontoa
grounded,three-wiresourceofsupply.
* Toavoidshockhazard,donotworkwithlive
electricalwires.
* Installthextureinonlydry,indoorapplications.
* Do not install outdoors or in applications other than
theintendeduse.
* Installandwirethextureinlocationsinaccordance
withallnational,stateandlocalcodes.
WARNING: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTIONS AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED.
WARNING: RISK OF FIRE, MINIMUM OF 90°C SUPPLY CONDUCTOR. CONSULT A QUALIFIED ELECTRICIAN
TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
WARNING: TO AVOID SHOCK HAZARD, DISCONNECT THE POWER AT THE PANEL BOARD (CIRCUIT
BREAKER BOX) BEFORE BEGINNING INSTALLATION.
11500 Melrose Avenue
Franklin Park, Illinois 60131
Phone: 847-451-0700
Fax: 847-451-7512
www.alkco.com
OVERVIEW
Read through the entire Installation Instructions
prior to beginning the installation.
A. PROCEDURE
1. Attachtheexpandablehangerbarstothebackboxusingthe
wingnutsprovided(asshowninFigure1).
2. Selectasuitablelocationforthexture.Themounting
bracketsmaybeexpandedtosecurethebackboxbetween
studs that are on either 16" or 24"centers.
3. Insertthesupplywiringattherearoratthesideofthe
backboxthroughoneofthethree(3)knockoutholes
provided.Attachconduitasrequired.
4. Situatethebackboxbetweenthewoodenstuds.Expand
thebracketendstothestudsandinitiallysecurethemby
hammeringtheirwoodspikesintothestuds.
5. Loosenthewingnutsandensurethatwhenthebackboxis
movedforwarditsedgeswillbeushwiththeexposed
surfaceofthewallmaterialtobeinstalled.Relocateas
required.
6. Naileachbracketendinplaceagainstthestudasshownin
Figure2.
7. Locatethebackboxineachdirectionasrequiredforush
mountingwithwallmaterialtobeinstalled.
8. Tightenthefourwingnutsandthencrimpeachyokebracket
rmlyontotherailsasshowninFigure2.Thiswillprevent
left/rightmovementofthebackbox.
Figure 1
Expandable
HangerBar
Wing Nut
CUSTOMER SUPPORT
IfyourequireadditionalinformationregardingthislightxtureweinviteyoutocallusatALKCO.Ourbusinesshoursare:
Monday-Friday(exceptholidays),8:00amto4:30pmCentraltime.Phone:847-451-0700,Fax:847-451-7512
REPLACEMENT PARTS
ContactAlkcoLightingdirectlyforinformationonreplacementparts.Whencalling,bepreparedtoprovidethemodel
numberanddateofmanufactureofthexture.Thisinformationisindicatedonlabelslocatedontheproduct.
.075.0027-Rev1 11/11 SO Series
B. WIRING CONNECTIONS
9. Connectthesupplyground(green)wiretothegroundingstudinsidethebackbox.ConnecttheACsupplyhot(black)lead
tothebrownleadoftheLEDpowersupply.ConnecttheACneutral(white)leadtotheblueleadoftheLEDpowersupply.
C. FACEPLATE INSTALLATION
10.ConnecttheleadextendingfromthefaceplatetotheLEDpowersupplyleadwiththequickdisconnectconnector(Fig.3).
11. ApplypowerandconrmproperoperationoftheLEDboard.
12.Installthefaceplatebysqueezingthewirespringstogetherandinsertingthemintotheupperandlowerretainerhoops
asshowninFigure4.
Figure 2
Figure 3
Figure 4
Squeezewirespring
together and insert into
retainerhoop.
Connect faceplate lead
toLEDtransformer
connector.
Allfaceplatemodelsinstall
inthesamemanner.
SO2N
SO3N
SO4N
Retainer
Hoop
Nail
Crimpeachyoke
bracketwith
pliers to secure
backboxon
bracketrails.
  • Page 1 1
  • Page 2 2

Chloride SoftGlo LED Night Light Install Instructions

Type
Install Instructions

Chloride SoftGlo LED Night Light is an energy-efficient and long-lasting lighting solution for indoor applications. It features an expandable hanger bar that allows for easy mounting between studs on either 16" or 24" centers. The three knockout holes provided in the back box offer flexibility for wiring, and the quick disconnect connector simplifies faceplate installation. With its flush mounting design, the night light seamlessly integrates with your wall décor.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI