American Dynamics ADTT32E Installation Instructions Manual

Category
Motorcycle Accessories
Type
Installation Instructions Manual

American Dynamics ADTT32E Enhanced TOUCH TRACKER is a device that offers advanced features for monitoring and controlling security cameras. It features SensorNet technology, allowing for easy setup and configuration of multiple devices, and supports up to two controllers for flexible management. The TOUCH TRACKER provides a user-friendly interface with a keypad and backlit LCD display for intuitive operation. It enables users to control camera functions such as panning, tilting, zooming, and focus adjustments, ensuring precise camera positioning.

American Dynamics ADTT32E Enhanced TOUCH TRACKER is a device that offers advanced features for monitoring and controlling security cameras. It features SensorNet technology, allowing for easy setup and configuration of multiple devices, and supports up to two controllers for flexible management. The TOUCH TRACKER provides a user-friendly interface with a keypad and backlit LCD display for intuitive operation. It enables users to control camera functions such as panning, tilting, zooming, and focus adjustments, ensuring precise camera positioning.

Installation Instructions
8000-2671-02, Rev. A (7 pages) AMERICAN DYNAMICS PRODUCTS 1
1 AD32 Enhanced TOUCH
TRACKER®
1
ADTT32E
With Video Matrix Switcher
A
B
C
D
1
2
3
4
5
6
7
8
9
0
P
e
e
l
I
n
f
o
O
n
O
u
t
p
u
t
O
f
f
C
l
e
a
r
M
e
n
u
I
r
i
s
C
l
o
s
e
O
p
e
n
F
l
i
p
V
i
e
w
P
a
t
t
e
r
n
R
e
p
e
a
t
P
a
t
t
e
r
n
S
e
q
P
r
e
v
i
o
u
s
N
e
x
t
About this Guide
This installation guide explains the procedures for
installing Enhanced TOUCH TRACKER controllers
with the Video Matrix Switcher. Other related
documents are:
Installation and Service Manual, 8000-1702-02
Operator's Manual, 8000-2655-02
Note: Because customer requirements dictate the
placement of T
OUCH TRACKER components, your
Sensormatic representative will supply this
information separately.
If you need assistance...
Call Sensormatic Customer Support at:
1-800-543-9740
1
TOUCH TRACKER, Sensormatic, and the Sensormatic logo are
registered trademarks of Sensormatic Electronics Corporation. Other
product names (if any) mentioned herein may be trademarks or
registered trademarks of Sensormatic or other companies.
No part of this document may be reproduced in any form without
written permission from Sensormatic Electronics Corporation.
© Copyright 1999. All rights reserved.
(CSD) 07/99
Parts Required
TOUCH TRACKER Installation Kit:
Part Number 0351-0474-07
INSTL KIT, TOUCH TRKR, W/RJ45 1
Description Qty Part No.
CABLE ASSY,MDLR,14FT,8 COND,CROSS-P 1 6003-0047-01
SCR,THD CUT,M2.9X9.5,PHP,ST,Z,T1 1 5899-0004-102
ANCHOR,PLASTIC,W/O SCREW,8-10 2 2880-0083-01
SCR,TYP AB,PHP,CAD,#8X1" 2 2816-7634-44
CONN,PLUG,TUBLR,.200CTR,26-12AWG,1X 1 2109-0254-04
LUG,SPADE,CRIMP,INSUL,22-16AWG 3 2141-0002
CABLE,3COND,18AWG,CM 16.5 6002-0024-01
INTERCONNECT BOX,TOUCHTRACKER 1 0300-1000-01
CABLE ASSY,TOUCH TRACKER,INTFC TO Q 1 0650-0932-01
HOOD,D-SUB,9POS,EMI/RFI,.25 DIA CAB 1 2125-0007-02
CONN,D-SUB,PLUG,HSG,9POS,SSI 1 2130-0021-01
FERRITE CORE 1 2700-0023-01
QUICK REFERENCE GUID 1 8000-2656-02
TOUCH TRACHER STRAIN RELIEF INSTR 1 8000-1370-01
WARNING Shock Hazard!
Disconnect AC Power.
CAUTION static sensitive
components!
Follow proper handling procedures to
prevent component failure.
Installation Procedures
See Remote Switcher Location for procedures
when the Video Matrix Switcher will be more than 4m
(14 ft) from the EIMs.
1. Attach each EIM to a wall or other surface within
3m (10 ft) of its TOUCH TRACKER controller.
2. Terminate the EIM that is at the end of the
SensorNet network.
See Figure 1 for the wiring diagram for a typical
2-controller AD32 system installation. For more
information on the SensorNet network, see the
SensorNet Network Guide (PN 8000-0970-01).
3. Attach the 3 spade lugs to one end of the 3-
conductor cable, then attach the lugs to the EIM
power transformer.
INSTALLATION INSTRUCTIONS
AD32 ENHANCED TOUCH TRACKER W/VM
S
8000-2671-02, REV.
A
2
Figure 1. VM32 Wiring Diagram
21354
J-Box #1
EIM #1
DB9 (M)
RJ45
RJ45
P1
P2
P3
P4
P5
P6
P8
RJ45
RJ45
EIM #2
J1
J2
J3
E1
32 1
1-2 TERMINATED
2-3 UNTERMINATED
J1
J2
J3
E1
321
1-2 TERMINATED
2-3 UNTERMINATED
5 2 3
21354
P1
P2
P3
P4
P5
P6
P8
21354
21354
J-Box #2
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32
1 2 3 4 5 6 7 8 SI NO NC C
1 2 3 4 5
1 2 3
RS232 PORTS
MONITORS
ALARMS
RELAY
120V
60Hz
CAMERAS
RJ45
5 4 2
ASSY
0301-0340-01 REV-
ASSY
0301-0340-01 REV-
UniCard
P3
UniCard
P3
321
DB9 (M)
5 2 3
RJ45
5 4 2
321
Primary
T
OUCH TRACKER
Secondary
T
OUCH TRACKER
Video Matrix Switcher
EIM DB9 (M)
COLOR PIN FUNCTION
Green 3 Receive
Red 2 Transmit
Orange 5 Ground
NOTE:
View Manager 32 supports up
to 2 controllers. Terminate E1
on the EIM that is on an end
point of the SensorNet network.
NOTE:
The maximum combined SensorNet
cable length is 1219m (4000').
24 Vac B
Ground
UNTERMINATED
EIM Transformers
24 Vac A
24 Vac B
Ground
24 Vac A
RJ45 Wiring
COLOR PIN
Green 5
Red 4
Orange 2
J-Box P8
COLOR PIN Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxillary A
Yellow 4 Auxillary B
J-Box P1-P6
COLOR PI
N
Function
Orange 1 SensorNet A
White 2 28Vac
Red 3 Ground
Black 4 28Vac
Yellow 5 SensorNet B
UniCard P3 Wiring
COLOR PIN FUNCTION
Orange 1 SensorNet A
Yellow 2 SensorNet B
Black 3 24Vac A
Red 4 Ground
White 5 24Vac B
TERMINATED
Ferrite Core
Ferrite Core
Modular
Cable
Data Cable
AD32 ENHANCED TOUCH TRACKER W/VMS
8000-2671-02, REV. A
INSTALLATION INSTRUCTIONS 3
4. Connect the power transformer cable and the
SensorNet data cable, and if required, the data
cable to EIM #2, to the compression connector,
and connect it to J3 on each EIM.
5. Wire the DB9 connector to the data cable. See
the tables in
Figure 1. Assemble the hood onto
the DB9 connector.
6. Install the ferrite core onto the cable assembly,
2.54-3.81cm (1 in.-1.5 in.) from the RJ45
connector (see
Figure 2).
7. Connect the data cable to J1 on the EIM to the
RS232 port 1 (primary) or port 2 (secondary) on
the rear panel of the Video Matrix Switcher.
8. Connect a modular cable to J2 on EIM and to the
T
OUCH TRACKER controller.
9. Plug each power transformer into a grounded,
3-wire receptacle.
NOTE: If the keypad and backlighting do not
illuminate when power is applied, unplug the
power transformers, check all wiring connections,
and repeat step 9.
10. Press Menu to configure the T
OUCH TRACKER
controller as a primary or secondary unit.
11. Page down the screen to the Tog Primary/2nd
menu option.
12. To select the Tog Primary/2nd menu option,
press the zoom (top line) or focus (bottom line)
button, as appropriate.
13. Press Next to toggle between using the T
OUCH
TRACKER controller as the primary unit or as the
secondary unit.
14. Press Menu to reset the TOUCH TRACKER
controller as a primary or secondary unit. The
controller will reboot to the Camera Control Mode.
Figure 2. Ferrite Core Attachment
0 in
2.54 - 3.81 cm
(1" - 1.5")
Resetting a Dome
1. Use the number buttons to select the dome to
reset, then press
(the Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll down to
Reset Dome.
4. Press the
zoom (top line) or focus (bottom line)
button to select the Reset Dome menu option.
The TOUCH TRACKER will send a request to the selected
dome to reboot.
Switching Primary and
Secondary Functions
between Controller Units
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Tog Primary/2nd.
3. Press the
zoom (top line) or focus (bottom line)
button to select the Tog Primary/2nd menu
option.
An asterisk (*) identifies the current setting for
the T
OUCH TRACKER.
4. Press Next to toggle between using the
primary unit for SensorNet polling and alarm
monitoring or as the secondary unit with
limited user functionality.
5. Press Menu to reset the controller as a
primary or secondary unit.
The controller will reboot and return to the Camera
Control Mode.
Adjusting V-Phase
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Adjust V-phase.
3. Press the
zoom (top line) or focus (bottom line)
button to select the Adjust V-phase menu
option.
4. Press Next or Prev to observe V-phase
through the oscilloscope or Fluke scope.
5. Press Menu to exit.
Off-line domes or fixed cameras will generate a warning
beep and disallow use of the V-phase utility. For
additional information on adjusting V-phase, see the
Service section of the View Manager 32 manual.
Ferrite
RJ45
DB9(M
)
Place 1 loop into
core slot; close core
halves; gently pull
cable to ti
g
hten loo
p
.
INSTALLATION INSTRUCTIONS
AD32 ENHANCED TOUCH TRACKER W/VM
S
8000-2671-02, REV.
A
4
Reviewing System
Information
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Show Sys Info.
3. Press the
zoom (top line) or focus (bottom line)
button to select the Show Sys Info menu
option. The LCD screen displays the following
message:
Primary/Secondary Indicator:
Primary Unit
<NEXT> <PREV>
4. Press Next to step through the following
messages:
Flash and EEPROM checksum values:
ROM Checksum
E=0A7B F=9C82
Flash
Checksum
EEPROM
Checksum
Tracker Ball calibration values:
Min 00 00 00 00
Max 00 00 00 00
Flash and EEPROM part numbers (including
version):
Flash Part Number
and Version
Product Code
F 0701-0000-0000
Product Code
E 0701-0000-0000
EEPROM Part Number
and Version
5. Press Menu to exit.
Performing SensorNet Ping
Test
1. Use the number buttons to select a dome to
test, then press
(the Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll down to
Ping Dome/TTR.
4. Press the
zoom (top line) or focus (bottom line)
button to select the Ping Dome/TTR menu
option and to start the ping test on the
selected dome. The LCD screen displays the
following message:
*
=Device being
tested
No. of pings
transmitted
*Dome Tx=0006
TTR Bad=0002
No. of failed
responses
5. Press Next to perform the ping test on the
Secondary T
OUCH TRACKER controller unit.
6. Press Menu to exit.
Off-line domes or fixed cameras will generate a
warning beep and disallow use of the SensorNet
network test.
Changing the Port Setting
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Port Settings.
3. Press the
zoom (top line) or focus (bottom line)
button to select the Port Settings menu option.
The LCD screen displays the following
message:
*Operating Mode
Download Mode
*
=Selected mode
4. Press Next to change the currently selected
mode.
5. Press Menu to save the change and exit.
AD32 ENHANCED TOUCH TRACKER W/VMS
8000-2671-02, REV. A
INSTALLATION INSTRUCTIONS 5
Remote Switcher Location
If the EIM and TOUCH TRACKERs will be located
more than 4m (14 ft) but less than 15m (50 ft) from
the Video Matrix Switcher, the following additional
equipment will be needed:
Description Qty Part No.
CABLE ASSY,MDLR,14FT,8 COND,CROSS-P 1 6003-0047-01
TERMINAL, RJ45 2 2113-0019-01
ANCHOR,PLASTIC,W/O SCREW,8-10 4 2880-0083-01
SCR,TYP AB,PHP,CAD,#8X1" 4 2816-7634-44
CABLE,3COND,18AWG,4M-15M (14’-50”) 1 6002-0024-01
WARNING: Shock Hazard!
Disconnect AC Power.
CAUTION: static sensitive
components!
Follow proper handling procedures
to prevent component failure.
Installation Procedures
1. Attach each EIM to a wall or other surface within
3m (10 ft) of its T
OUCH TRACKER controller.
2. Terminate the EIM at the end of the SensorNet
network.
See Figure 1 for the wiring diagram for a typical 2-
controller VM32 system installation. See
Figure 3
for the wiring diagram for remotely located Video
Matrix Switcher. For more information on the
SensorNet network, see the SensorNet Network
Guide (PN 8000-0970-01).
3. Attach the HP0047 terminal boxes to a wall. The
remote terminal box must be within 15m (50 ft) of
the EIM terminal box.
4. Connect the 3-wire, 18AWG shielded cable to the
terminal boxes (see
Figure 3).
5. Attach the 3 spade lugs to one end of the 3-
conductor cable, then attach the lugs to the EIM
power transformer.
6. Connect the power transformer cable and the
SensorNet data cable, and if required, the data
cable to EIM #2, to the compression connector, and
connect it to J3 on each EIM.
7. Wire the DB9 connector to the data cable. See the
tables in
Figure 3. Assemble the hood onto the
DB9 connector.
8. Connect the data cable to J1 on the EIM to the
HP0047 terminal box.
9. Install a ferrite core onto a modular cable assembly,
2.54-3.81cm (1 in.-1.5 in.) from an RJ45 connector
(see
Figure 2).
10. Connect the modular cable to the remote HP0047
terminal box and to the RS232 port 1 (primary) or
port 2 (secondary) on the rear panel of the Video
Matrix Switcher.
11. Connect a modular cable to J2 on EIM and to the
T
OUCH TRACKER controller.
12. Plug each power transformer into a grounded,
3-wire receptacle.
NOTE: If the keypad and backlighting do not illuminate
when power is applied, unplug the power
transformers, check all wiring connections, and
repeat step 12.
13. To configure the TOUCH TRACKER controller as a
primary or secondary unit, page down the screen to
the Tog Primary/2nd menu option.
14. To select the Tog Primary/2nd menu option, press
the zoom (top line) or focus (bottom line) button, as
appropriate.
15. Press Next to toggle between using the T
OUCH
TRACKER controller as the primary unit or as the
secondary unit.
16. Press Menu to reset the T
OUCH TRACKER controller
as a primary or secondary unit. The controller will
reboot to the Camera Control Mode.
6 INSTALLATION INSTRUCTIONS
AD32 ENHANCED TOUCH TRACKER W/VM
S
8000-2671-02, REV.
A
Figure 3. VMS Wiring Diagram—Remote Switcher Location
5 2 3
RJ45
RJ45
RJ45
DB9 (M)
24 Vac A
Ground
24 Vac B
1
2
3
45
8
7
6
1
2
3
45
8
7
6
5 4 2
RJ45
RJ45
J1
J2
J3
EIM
5 4 3 2 1
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32
1 2 3 4 5 6 7 8 SI NO NC C
1 2 3 4 5
1 2 3
RS232 PORTS
MONITORS
ALARMS
RELAY
120V
60Hz
CAMERAS
Transforme
J3 Wiring
Pin Function
1N/A
2 24Vac A
3 Ground
4 24Vac B
5N/A
DB9 (M) Wiring
Color Pin Function
Green 3 Receive
Red 2 Transmit
Orange 5 Ground
Touch Tracker
RJ45 Wiring
Color Pin
Green 5
Red 4
Orange 2
Video Matrix Switche
r
3-wire, 18AWG
shielded cable
Shield
EIM
Terminal
B
o
x
Data
Cable
Modular
Cable
Modular
Cable
Ferrite
Core
Remote
Terminal
Box
AD32 ENHANCED TOUCH TRACKER W/VMS
8000-2671-02, REV. A
INSTALLATION INSTRUCTIONS 7
Alarm and Relay
Connections
The back panel of the VM32 Video Matrix Switcher
provides eight alarm contact inputs, an external
frequency synchronization input, and contact
terminations for an internal alarm-activated relay.
You can program the Form-C internal relay to
activate during alarms for control of a VCR or
other alarm response device.
Figure 4. Alarm/Relay Connections
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32
1 2 3 4 5 6 7 8 SI NO NC C
1 2 3 4 5
1 2 3
RS232 PORTS
MONITORS
ALARMS
RELAY
120V
60H z
CAMERAS
1 2 3 4 5 6 7 8 SI NO NC C
ALARMS
RELAY
The following is a description of the alarm and
relay connector pins.
Pin Description
1Ground
2Alarm 1
3Alarm 2
4Alarm 3
5Alarm 4
6Alarm 5
7Alarm 6
8Alarm 7
9Alarm 8
10 Ground
11 External Sync Ground
12 External Sync Input
13 Ground
14 Relay–Normally Open
15 Relay–Normally Closed
16 Relay–Common
Connections
Alarms
Alarm contact closures must have a resistance
of 500 Ohms or less.
Connect alarm contacts to inputs 1 through 8
(pins 2 through 9).
Connect alarm contact returns to Ground (pin
1 or 10).
External Sync
External sync input signal must be 1-5Vrms,
50/60Hz.
Connect external sync input to SI (pin 12).
Connect external sync ground to Ground (pin
11).
Relay
Connections for the internal relay are normally
open (NO), normally closed (NC), and
common (C). The relay contact ratings are
0.6A @ 120Vac or 2.0A @ 30Vdc.
Connect an alarm-response device requiring a
normally open circuit to NO (pin 14) and C (pin
16).
Connect an alarm-response device requiring a
normally closed circuit to NC (pin 15) and C
(pin 16).
Pin 1
Pin 16
Video Matrix Switcher—Rear Panel
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

American Dynamics ADTT32E Installation Instructions Manual

Category
Motorcycle Accessories
Type
Installation Instructions Manual

American Dynamics ADTT32E Enhanced TOUCH TRACKER is a device that offers advanced features for monitoring and controlling security cameras. It features SensorNet technology, allowing for easy setup and configuration of multiple devices, and supports up to two controllers for flexible management. The TOUCH TRACKER provides a user-friendly interface with a keypad and backlit LCD display for intuitive operation. It enables users to control camera functions such as panning, tilting, zooming, and focus adjustments, ensuring precise camera positioning.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI