Vari-Lite Showline SL RDM COMMANDER User manual

Category
DJ controllers
Type
User manual

This manual is also suitable for

RDM Commander
Philips Group 2013
All rights reserved.
The Company reserves the right to make any
variation in design or construction to the
equipment described. E&OE
Philips Entertainment Lighting Asia( )PELA
Tel +(852)2796 9786:
Fax +(852)2798 6545:
Unit C , 14/F, Roxy Industrial Centre,NO. 41-49, Kwai Cheong
Road,Kwai Chung, N.T.Hong Kong
Tel +(86)010-5867 4776:
E-mail Showline_info@philips.com:
BeiJing Office
Room 1201,Free Town D Tower,58 South 3 Ring Road East
ChaoYang District BeiJing
Sh wline
RD M CO MMAND ER
RATE
REV FWD
RD M
MO DE
CO PY
IN FOR
AD DR
RE SET
CA L
LA BEL
BAC KUP
UP DATE
F 2
F 1
SHORTCUT OPERATION
Philips Showline Offices
Thank you for purchasing Philips Showline products. every product has been thoroughly tested and carefully
packed before delivery. Unpack the shipping carton carefully and save the carton with all packaging
materials for possible future use.
Check carefully for sure your product is not damaged and all accessories not missing. if your product appears
to be damaged or missing, please do not use it and contact your local dealer immediately.
The material in this manual is for information purposes only and is subject to change without notice.
Philips Entertainment assumes no responsibility for any errors or omissions which may appear in this
manual. For comments and suggestions contactregarding corrections and/or updates to this manual, please
your nearest Philips Entertainment office.
Note: information contained in this document may bot be duplicated in full or in part by any person without
on the equipment mentioned. The use of this document for all other purposes is specifically prohibited.
Document Number: 24-004-3540-00
Rev1.1
RDM Commander User’s Manual
c
2013 Philips Group. All rights reserved.
RDM Commander
RDM Commander
prior written approval of Philips Showline. Its sole purpose is to provide the users with conceptual information
Philips Entertainment Dallas
10911 Petal Street
Dallas, TX 75238
Tel: +1 214647 7880
Fax: +1 214647 8030
Philips Entertainment Europe
Marssteden 152
Enschede 7547 TD
The Netherlands
Tel: +31 53450 0424
Fax: +31 53450 0425
Philips Entertainment New Zealand
19 - 21 Kawana Street, Northcote
Auckland 0627, New Zealand
Tel: +64 9481 0100
Fax: +64 9481 0101
Philips Entertainment Lighting Asia Limited
Unit C, 14/F, Roxy Industry Centre
No. 41 - 49 Kwai Cheong Road
Kwai Chung, N.T. Hong Kong
Tel: +852 27969786
Fax: +852 27986546
25
The hardware code of this unit is upgradable. Copy the source hardware code and
paste it into the RDM_Commander menu of the mini SD card, then insert the mini
SD card to the SD card socket of this unit. Turn off the unit. Keep on pressing F1 and
F2 new hardwarekey at the same time will power on the unit again, the unit will read the
code file and start updating.automatically
After update, the unit will automatically restart.
Please follow the steps as below.
Step 1. Power on the unit and wait for at least 2 seconds, select RDM Tester menu at the
main menu.
Step 2. Select the user defined RDM parameters (RDM PID ).≥0x8000
Step 3. Select and press the function menu .Set
Step 4. Keep on pressing the Update key, and press the F1 key or F2 key simultaneously to
define the parameter and save it to the responding function key.
Once finished defining the function keys, user can set the RDM parameters by shortcut
operation.
TABLE OF CONCENTSFUNCTION KEYBOARD
RDM Commander
RDM Commander
1
24
OPERATION GUIDE
Main Menus
DMX Packet Test
1. Data Format
2. Data Timing
3. Data Level(Volt)
GENERAL INFORMATION
Description
Safety Instructions
Specifications
DMX Data RX
1. Barchart display
2. Value display
3. Min/Max display
DMX Data TX
1. Modify Channel
2. Signal Channel
3. Color Mode
4. Chase Mode
RDM Tester
DMX-1000K RX
DMX-1000K TX
Moving Light
1. Library Setting
2. Play mode
Cue Save/ Run
Cable Test
MIDI Data-RX
System Setup
1. DMX & RDM Setting
2. Display Setting
Product View
Physical Diagram
SHORTCUT OPERATION
TABLE OF CONTENTS
2
2
2
3
3
4
5
5
6
7
8
8
9
11
12
12
13
15
15
16
17
17
18
19
20
20
21
View Device_info: press the < at the third line to acess the sub-menu, and the LCD display
will show information as below.
Filename. ncw: press the < at the third line to select the file name to be updated.
Update: press the > at the fourth line to activate the updating.
<Device infor
Protocol Ver:01.00
Software Ver_ID:
20.18.01.30
Model ID: 20.18
Footprint: 01
Personality: 02/06
Start Addr: 01
Sub-Dev Count: 00
Senor Count; 01
Product Category:
Special LED Dimmer
UPDATE key
F1/F2 key
Press UPDATE key to update the hardware code. The LCD display will show as below.
User can use these two function keys (F1 and F2) to define the RDM parameter function.
<Device: 01/05
>SL PAR 130
Filename. ncw <
Update>
At present this function can only be available to the fixtures with upgradable hardware code.
<Device: 01/05
>SL PAR 130
View Device _info <
Calibration: Set ON or OFF the calibration function.
INFOR Key
Press INFOR key to check the related RDM devices’ information. The LCD display will show
as below.
SHORTCUT OPERATIONGENERAL INFROMATION
RDM Commander
RDM Commander
2
23
GENERAL INFORMATION
Description
Reduce the risk of electric shock or fire when using this unit.
Do not immense in or expose to water.
Turn off this unit, if not being used for a long time.
Do not use immediately in the event of malfunction.
Do not dismantle or modify the unit, only by qualified staff.
Safety Instructions
Power Input 9V DC , 500mA
( an AC ~ DC adaptor included or
built-in rechargeable battery)
DMX In 3pins/5 pins male XLR connectors
Power Consumption 4.5 W
Compliant Protocols Standard DMX512(1990) and
DMX-1000K, RDM
DMX Out 3pins/5 pins female XLR connectors
MIDI In 5 pins male XLR socket
IP Rating IP20
Dimension 207.5X208X75mm
Specifications
Note: All rights reserved. No part of this manual may be reproduced in any form
or by any means without written permission.
Weight 0.6Kg
Thank you for your purchase of the RDM Commander. The RDM Commander is a
professional RDM tester with the features of stylish design and versatility. With it's
flexible dial wheel, the user may use it to access all the menus and do the tests DMX
packet and cable concerned.
It's 4x20 characters LCD displays the menu states and the received DMX data which
makes the operation interface is very friendly. Please read this user's instruction
carefully before operation.
<Source Device:
>SL PAR 130
To: All Same Device <
Paste >
<Device: 01/05
>SL PAR 130
Store to Card <
OK >
<Device: 01/05
>SL PAR 130
Calibration: ON <
Set >
Source Device: To select the source device.
To: To select the target device.
All Same Device: all the devices that the Manufacturer No. and Model No. are the same.
Paste: Copy the RDM parameters of the source device and then paste them into the target
device.
Store to Card: save the RDM parameters into the SD card.
Restore from Card: Restore the RDM parameters from the SD card.
BACKUP key
CAL key
Press BACKUP key to backup RDM parameters. The LCD display will show as below.
Press CAL key to calibrate the color of RDM devices. This operation is only available to
the fixtures with color calibration function. The LCD display will show as below.
COPY key
Press COPY key to copy the parameters of the RDM device. The LCD display will show
as below.
<Device: 01/05
>SL PAR 130
Default Set: False
Set >
Default Set: Select default setting or not.
DC IN PUT:
9VD C, 500m A
MID I IN
Und er Volta ge (Red )
Pow er (Gre en)
DMX IN DMX OUT
1=Gr ound; 2 =Data -; 3=Da ta+; 4= NC; 5=N C
1=Ground; 2=Data-; 3=Data+; 4= ; 5=5 Volt(Midi) Signal(Midi)
PHISICAL DIAGRAMSHORTCUT OPERATION
RDM Commander
RDM Commander
3
22
Physical Diagram
Displays the functions and guides you to operate the unit.
Used to operate this device
1. LCD :
2. Dial Wheel : .
It will light red when the unit is in the state of "under voltage". It will
light green when the unit was supplied with the full power source .
Connects to the power of 9V DC, 500mA .
Used to input DMX signal via 5-pin/3-pin connector. To input MIDI via 5-
pin connector.
Outputs DMX signal via 5-pin/3-pin connector.
3. Power Indicator :
4. DC INPUT:
5. DMX/MIDI IN:
6. DMX OUT :
RDM C OMMAN DER
RATE
REV FWD
RDM
MODE
COPY
INFO R
ADDR
RESE T
CAL
LABE L
BACKU P
UPDATE
F 2
F 1
1
2
Product View
3
4
5
6
Press < at the third line to set the start address, the LCD display to show as below:
Addr: xxx/yyy <
xxx stands for the current address or the address to be set, while yyy stands for the provided
reference address.
Set: Once finish setting the desired parameters, send them to the RDM devices.
MODE key
LABEL key
RESET key
Press MODE key to set the working mode of the RDM device. The LCD display will show
as below.
Press LABEL key to rename the RDM device. The LCD display will shows as below.
Press RESET key to restore the default parameters of the RDM device. The LCD display
will show as below.
<Device: 01/05
>SL PAR 130
Single Channel Mode/001 <
Set >
<Device: 01/05
>SL PAR 130
L:SL PAR 130 <
Set >
Char String/xxx: Selected working mode and the DMX channel.
L: xxx: The characters need to be set.
Device: The total RDM devices and the current device number.
>SL PAR 130: The desired device to be set.
Addr: The current start address of the device.
searched
< Device: 01/05
> SL PAR 130
Addr: 001 <
Set >
MAIN MENUS
SHORTCUT OPERATION
RDM Commander
RDM Commander
4
21
RDM Commander, which can be applied in various lighting occasions to meet your
requirements, provides ample menu options in 20 x 4 LCD window for you. The desired
menu or window can be activated by turning the Dial wheel, and by pressing this Dial
wheel in the central place will access to the menu functions.
OPERATION GUIDE
Pressing the dial wheel will access the top window.
There are 11 main menu options for your choice, including DMX packet test, DMX
data-RX, DMX data-TX, RDM Teseter, DMX 1000K--RX, DMX 1000K--TX, Moving light,
Cues Save/Run, Cable Test, MIDI data--RX and System setup.
< DMX Packet test >
DMX data--RX >
DMX data--TX >
RDM Teseter >
< DMX 1000K--RX >
DMX 1000K--TX >
Moving Light >
Cues Save/Run >
MIDI data-RX >
System Setup >
Main Menus
DMX Packet Test
Turn the Dial wheel clockwise to select DMX packet test and then press the Dial wheel
to access this function.
To increase the charging speed, do not switch on this unit. The time for full charging
battery is about 3~5 hours, which can supply the unit for 6~8 hours. When switching
the unit on at first, with its switch at back cover, the LCD window shows main window
information as follows:
The power of this unit can be supplied by built-in storage battery or DC 9V adaptor.
When using DC 9V adaptor for this unit, the built-in battery will automatically be
charged at the same time.
NOTE: If you want to browse the next forward menu, please turn the Dial wheel clock
-wise. On the contrary, you may turn it unticlockwise to browse the previous menu
option.
Power on the unit, the LCD will display the unit name and current software version. Wait for
more than 2 seconds with no operation, the LCD will automatically display the main menus.
Cable Test >
Contrast Level: The default level is 05 and it must range from 01 to 10. User can improve
the display effect by increasing the Contrast Level when the voltage is low.
Back Light: To change the state of back light, you can enable the label > at the second
line. Pressing the Dial wheel to turn on/off the back light, while pressing it again to
complete your setting and exit "Back light". Turn on the Back light, it will be light when
setting the Encoder. The back light will automatically off if there is no operation on
Encoder within 10 seconds.
Display: You can also change the value display in three modes, including decimal,
hexadecimal and percent. To save what you have set, press the label > at the fourth
line to confirm by Dial wheel. Without saving, enable the label < to return the previous
menu.
< 3. Display setting
Contrast _level: 1-10
Back light : On/Off
dec, hex or % data
For more information, press ? for help.
There are 11 in on the front panel, which can
be used to set the common parameters of the connected
RDM devices.
keys total
Power on the unit and wait for more than 2 seconds, the LCD will automatically display
the main menus. Press to activate the RDM shortcut function. The unit will
search the online RDM devices automatically and access the start address setting
function( ) . The LCD display shows as below.
RDM key
ADDR
RD M COMM AND ER
RATE
REV FWD
RDM
MOD E
COP Y
INF OR
ADD R
RES ET
CAL
LAB EL
BACK UP
UPDATE
F 2
F 1
Shortcut Operation(Function Keyboard)
(1) Create a subdirectory named rdm_commander under
the root menu of mini SD card.
(2) COPY the files to be updated and the stored data to
the subdirectory.
(3) Eject the mini SD card from the PC, and then insert it
into the mini SD slot of this unit.
Functions of BACKUP and UPDATE acquire a mini SD
card. Connect the mini SD card to PC with a proper card
reader and then operate as below.
DMX&RDM SETTING
DMX PACKET TEST
RDM Commander
RDM Commander
5
20
If there is no signal input and you have accessed each menu of Data format, Data
timing, Data level ( Volt ) by the Dial wheel, the LCD window shows the same as follows:
< DMX packet test:
Receive no signal ?
You may locate the cursor to the label ? for help. In this case, the help message usually
shows:
< DMX-512 tester help
No signal or signal
not complying with
USITT DMX-512( 1990 )
On the contrary, if there is signal input, you can do some DMX packet tests .
< Data format ?
RX-Chan: 512
Break:--OK--
Signal preset
1. Data format
Turn the Dial wheel to select and press it for viewing the total channelsData format
of external operator and the states of BREAK when receiving the signals.
< DMX packet test:
1. Data format >
2. Data timing >
3. Data level ( Volt ) >
< Data format:
Indication of --OK--
means:Received
signal is good
To return to the previous menu, press the by Dial wheel.<
For the further information, you may
e help information shows as below.
locate the cursor to the label ? and press the
wheel for help. Th
Turn the Dial wheel to select and press it for application. You can viewData timing
all the parameters of the received signals, including BREAK, Mask B$S, START
CODE, CHAN TIME, Period Time. The LCD window will dynamically show data timing
information.
2. Data timing
The LCD window shows the channel information of external connected DMX operator.
Turn the Dial wheel to DMX & RDM Setting and press it, then the LCD window shows
the following message for you.
1. DMX & RDM Setting
AUTO Identify: There are two modes can be set: On and OFF mode. Set , the fixture
will automatically send Indentify order to the selected device in RDM Tester function. While
set OFF, the fixture will not automatically send Indentify order.
it ON
it
16bit: To set the order of the 16bit precision channel data. User need to make settings when
selecting from TX-COLOR mode and CHASE mode. For example, PIXEL: 16bit-COLOR.
Press Confirm> to save all the settings in this menu.
Max Level: Turn the Dial wheelThere are two modes available: Normal and Hold Mode.
to > at the second line, then pressing it can shift between Normal mode and Hold mode.
In Normal Mode the unit will display all the received DMX data, while in Hold Mode it
will display the maximum value of each channel.
< DMX& RDM SETTING ?
Start Code : 000 >
RX Start Code: 000 >
Max Level: Normal >
Auto Identify OFF >
16bit: Coarse first >
Confirm >
TX
TX Start code: You can set the start code for DMX 512 signal transmission, which can
be reflected in setting range is 0-255.the DMX data-TX function. The
RX Start Code: The default of start code is set to 000, that means the unit only receive
DMX signals with 000 start code . If you would like to amend it, use the Dial wheel for
this purpose. The setting range is 0-255 and All. All means receive DMX signals with
all kinds of Start Code.
In this sub-menu you can adjust the display and contrast level of the LCD window by
Dial wheel.
< Contrast Level : 08 >
Display : Decimal >
? Confirm >
Back light : OFF >
2. Display setting
DMX DATA-RX
SYSTEM SETUP
RDM Commander
RDM Commander
6
19
Select > firstly and then press it can shift from Chan. Time to Period Time.
< Start Code: 000 ?
Break: 100us
Mask B$S: 10us
Chan. time: 48us >
< Data Level(Volt) ?
--Good-->
Level = 4.44V
...
For further information, you may use the help function by pressing Dial wheel.
3. Data level ( Volt )
The LCD window will dynamically shows the information of signal voltage .
< 3. Data level
Reception may still
be possible with
lower levels.
For the further information, you may use the help function by pressing Dial wheel. The
help information shows as below.
For another menu available, you may turn the Dial wheel backward to return. Then
select the new entry by Dial wheel.
< DMX data RX:
1. Barchart display >
2. Value display >
3. Min/ max display >
Turn the Dial wheel to select and then press the Dial wheel accessDMX data--RX
this menu function. There are 3 sub-menu options, including Barchart display, Value
display and Min/max display.
Turn the Dial wheel to select and press it in the central place for
application.
Data level ( Volt )
System setup
In this menu you can set the system settings at your disposal. There are two sub-
< Cable Test ---
Test Result:
>> Cable failure!
---
< Cable Test ---
Test Result:
>> Cable OK
---
Otherwise, if the cable can not work normal, the LCD window shows:
This option can receive MIDI signals and show it on the LCD window. The update
speed of data is relate to the received signals. The larger the number of the received
signals, the faster the data change speed. If there is no signal received, the data on
the LCD window will keep the same.
MIDI data -- RX
If the cable works normal, the LCD window shows as follows:
< System set up :
1. DMX & RDM setting >
2. Display setting >
< MIDI data RX:
$ - - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
menus for your choice, including DMX &RDM setting and Display setting. You can
set the the DMX & RDM parameters and the display mode of LCD, and so on.
Turn the Dial wheel to System setup and press it to enable this function. The LCD
window shows as follows.
DMX Data-RX
CABLE TEST DMX DATA-RX
RDM Commander
RDM Commander
7
18
In the display mode, when pushing the fader relative to the specific channelNormal
of external operator, the relative channel value of the LCD window will change tempora
- conforming with the position of fader.rily,
< RX Channel :000 ?
001: xxxxx xxxxx
011: xxxxx xxxxx
021: xxxxx xxxxx
Total channels of received
signal:000
Means: no signal input from
channel 1 to channel 10
Turn the Dial wheel forward to enter the Barchart display option. If there is no signal
input, the LCD window always show empty information as follows:
1. Barchart display
< RX Channel :512 ?
>001:
011:
021:
< 1. Barchart display
x = no signal
- = no data
Each line can indicate the values of 10 channels in all. To browse the other values of
channels, turn the Dial wheel forward to select , then press the Dial wheel . At this>
time you can turn Dial wheel backward or forward for this purpose.
On the contrary, if there is signal input, the LCD window will display the values of
received signals in the bar chart diagram.
Each bar chart indicates the
different value of the fader.
For the further information, you may use the help function by pressing Dial wheel. The
help information shows as below.
This DMX data--RX function can display the value of signal input by the means of
Barchart and Value and Min/max, complying with the display mode that can be adjusted
in the System setup menu.There are two display modes: Normal and Hold Mode.
In the display mode, when pushing the fader relative to the specific channel ofHold
external operator, the relative channel value of the LCD window may not change
temporarily. The display value is only the max. value of al the adjustment by the
fader.
LLLLL LLLLL
LLLLL LLLLL
LLLLL LLLLL
Chan Level
< Save Cue ( Scene )
The cue with 512 data
can be stored to
memory or clear cues
< Save Cue ( Scene ) ?
As Cue No.:01 >
Save >
< Run more Cue:
1.Start:01 > End: 99>
2. Run Speed:01 >
3.Fade Time:100% >
For more information, press ? for help.
Select Run cue then access the function, the LCD window show a message as below:
Locate to > at the first line and turn the Dial wheel. Then you can set cue desire to run.
Locate to > at the second line and turn the Dial wheel to set the data change speed
in the range of 01-10.
Locate to > at the third line and turn the Dial wheel to set fade time of data change in
the range of 01-100.
Set the Auto Speed as 0, then user can modify the auto speed manually. The LCD window
shows the following diagram.
Manual Mode >
Go >
The data will change synchronously with each pressing of Go. You can save it into a specific
number while you accessed " Save Cue" menu. This function can be done only NO DMX
signal input.
Use the standard DMX In/Output of this unit for connecting the cable. One head for
female plug-in, another head for male plug-in. Then press > at the fourth line to start
the test.
When enable this function, you can test the cable whether there are errors or not.
Cable test
< Cable Test
Connect Cable to
DMX IN and DMX OUT
Socket. Press OK>
DMX DATA-RX CUE SAVE/RUN
RDM Commander
RDM Commander
17
8
The default total channels is set to be 000 and the start channel always is automatically
preset to be 001. If you would like to change the start channel, turn the Dial wheel to
select > at the right side of the LCD window then press it. Now you can scroll to the
desired channel No., then press the Dial wheel again to confirm.
< RX Chan:512 >001
255 255 255 000 000
> 000 000 000 000 000
000 000 000 000 000
For decimal, hexadecimal or percent display mode, you can turn the Dial wheel to
select > at the left side of the LCD window. And then press the Dial wheel to scroll to
the desired mode. The display values of the relative channels will temporarily be
changed according to the new setting.
You can also display the values in a simple way when using this option , only for min.
value, typical value, max. value. But the values will comply with the decimal, hexa-
decimal or percent display mode what you have set.
On the contrary, if there is signal input, the LCD window will display the values of re-
ceived signals in the following diagram.
NOTE: Other main display values of this unit may be converted, complying with the
new display mode.
3. Min / max display
Supposed that you have set the percent display mode. If there is no signal input, the
LCD shows as follows.
< RX Chan:000 >001
--- --- --- --- ---
> --- --- --- --- ---
--- --- --- --- ---
This option can display the value of signal input by the means of decimal, hexadecimal
and percent. Turn the Dial wheel forward to enter the Barchart display option. If there
is no signal input, the LCD window always show empty information as follows:
2. Value display
< RX Channel : 000
Chan. Min cur max
>001 --- --- ---
>Elapse:0Sec.
Locate to > at the First line and turn the Dial wheel. Then you can select the set
fixture name. The relative library settings can be available. Complying with the fixture
channel, locate to > at the second line and turn the Dial wheel to set the right start
address.
<Fixture: fix_01 >
Start Address:001 >
Attribute:Pan >
DMX level:000 >
In this function you can test the fixtures by using the previous library settings. Turn
on the Dial wheel to select . The LCD window show a message as follows:Play mode
2. Play mode
If there is DMX signal input at present, the saved cue can be the received signal.
However, when no signal input, enabling this Save Cue function will save the previous
received or running cue as new one. By the way, you can access the 512 channel of
DMX data--TX menu to set values of the desired channels or modify the existed cue,
and then enabling this Save Cue can also save the settings as new cue. User can save
99 cues/scenes at most.
Cue Save/Run
Locate the > at the third line to the desired fixture attribute name. Then locate the >
at the fourth line to set the DMX value of the fixture attribute.
< Cues ( Scene ) :
1. Save Cue(Scene) >
2. Run Cue(Scene) >
When accessing this menu, the LCD window will ask for you the cue number to be
saved.
If you would like to set the lighting function of this unit for testing the other lighting
equipments, do pay attention to the relative channels parameters of them. What you
have set must be complying with the devices.
You can turn the Dial wheel to browse the functions of other channels.
The default cue no. is preset to be 01. You can change the default cue number to
the desired one. First locate to > at the second line and turn the Dial wheel for this
purpose. To save the received data, press save> at the third line to confirm. Other
- automatically save the received data and the cue number will increase by 1wise,
for the next saving.
MOVING LIGHT DMX DATA-TX
RDM Commander
RDM Commander
9
16
This option can display the levels of 512 channels, and also be used for temporary
adjustments, while the actual channel value can be held. When using the Dial wheel
to enter this sub-menu, the LCD window usually shows as follows:
1. Modify Channel
Turn the Dial wheel to select and then press the Dial wheel to accessDMX data--TX
this menu function. There are 4 sub-menu options, including Modify Channel, Single
Channel, Color mode, Chase Mode.
While accessing this DMX data--TX menu, new coming DMX signal will be disabled.
You are allowed to temporarily set the levels for the intended channels, and also have
priority to transmit cue ( scene ) at a set rate. Remember there are 99 cues available.
When switching on the unit, the receiving DMX signal can be transmitted automatically,
with the STARTCODE you have set. Supposed that you aren't in this DMX data--TX
menu now and there is no DMX signal input, if you have run the specific saved cue
just now , the cue will be transmitted repeatedly.
DMX Data -- TX
Note: The min value display is the min. value of all the adjustments referring to the
present channel; the typ value display is the set value of the present channel; the max
display is the max. Value of all the adjustments referring to the present channel.
To browse the value of each channel, turn the Dial wheel to select > at the third line
of LCD window, then press the Dial wheel. At this time you can browse the desired
channel by turning the Dial wheel backward or forward. Turn the Dial wheel to select
> at the fourth line and press the dial wheel can reset the current value.
On the contrary, if the signal input has been received correctly, the LCD window dis-
plays the following diagram.
< RX Channel : 512
Chan. Min cur max
>001 000 000 000
>Elapse: 68Sec.
Total channels
Time counter for reference.
In this case the new coming DMX signal will have priority to be transmitted. However,
when accessing the Cable Test or MIDI data-RX menus, the transmitting signal will
be halted.
The function and operation of DMX1000K--TX are similar to those of DMX data
TX. Please refer to the information of DMX data--TX on page 9.
< Moving light :
1. Library setting >
2. Play mode >
Turn the Dial wheel to select and then press the Dial wheel to accessMoving light
this menu function. There are 2 sub-menu options, including ,Library setting Play
mode. You can set the function of each fixture channel, complying with the present
library. The library of this unit is preset to meet your requirements in general. If you
would like to use your own library, please mail us an attachment of this information
for update. For more tests, in the you can use the library settings and adjustPlay Mode
the parameters of relative channels for this purpose. After accessing the Moving
light, the LCD window usually shows as follows:
Moving light
To set the lighting function of the desired channel, you can use Dial wheel to access
this option. The LCD window will show the fixture number, name and function of each
channel. Remember that there are only 36 channels and 10 kind of fixtures in all,
which can be set. And each channel has 29 effect functions to be selected.
1. Library setting
< 1. Library setting >
Fixture No. 01 >
Fix Name: Fix_01 >
>Attr01: Pan >
Precision:16bit >
High Chan:01 >
Low Chan.: >
Confirm>
Fixture No.: Select the fixture desired to edit. There are totally 32 pcs available.
Fix Name: Set the name of fixture.(totally 8 characters)
Attr01: Select the reference number of fixture properties. User can set 36 reference
numbers at most.
Pan: Select the name of reference number. Totally 45 normal name are available.
Precision: Select the precision of fixture between 8 bit and 16 bit.
When setting the precision as 16 bit, the High Chan. and Low Chan. are the control
channels of the fixture. While setting the precision as 8 bit, the High Chan. is the
control channel of the fixture.
Confirm: Make sure and save the parameters you have set.
DMX DATA-TX DMX-1000K--RX
RDM Commander
RDM Commander
15
10
< 1. 512 Channel ?
Send Speed: 01 >
Chan : 001 >
Data : 127 = 50% >
To adjust the temporary value of the desired channel, first enable the Dial wheel to >
at the third line. Then adjust the "Data" at the fourth line. The "Data" display the value
by the means of decimal and percent.
001- 010]
127 000 000 000 000
000 000 000 000 000
Cue:01> Save Cue>
> CLR>
Channel 1
Channel 2
Channel 5
Channel 10
Channel 3
You may turn the Dial wheel to scroll to the next page. The LCD window shows the
values of 10 channels at the following diagram.
Send Speed: To sent the output speed of different data packet. Please refer to the
table below for more information.
Chan: To set the desired channel.
Data: To set the output value of the corresponding channel.
CLR: Zero cleaning the output value by shortcut operation.
Cue and Save Cue: Save the current output value as a cue. Maximum 99 cues can be saved.
Speed
Space
for break
Maskbetween
break & start code
Maskbetween
frames
Maskbetween
packet
1
2
3
4
5
6
7
8
9
10
100us 15us 52us 200ms
100ms
50ms
30ms
50ms
30ms
25ms
25ms
50ms
23ms
52us
52us
52us
48us
44us
44us
44us
48us
48us
15us
15us
15us
15us
15us
15us
10us
10us
10us
100us
100us
100us
100us
100us
100us
90us
90us
90us
You can set these values of 10 channels ( 001 -- 010 ).For example, set the value for
channel 1. Locate the cursor to the desired channel, press the Dial wheel to select
it. Then turning the Dial wheel to adjust the level. When satisfying the adjustment,
press the Dial wheel again to confirm the settings.
3)The manufacturer specific PIDs are displayed with hex form and which were excluded
from the above 45 or 28 PIDs .
4)You can carry out GET "DMX_PERSONALITY_DESCRIPTION", GET"SENSOR_
DIFINITION" and GET"SENSOR_VALUE" only you if perform GET " DEVICE_INFO"
first.
5)You can GET or SET the relevant PID only if you perform GET " PARAMETER_
DESCRIPTION" first.( " PARAMETER_DESCRIPTION" is a description for the
relevant manufacturer specific PID.)
1) For "COMMAND: GET", when the UID(Unique ID) was chosen, the PID (parameter
ID) can only be selected in the range of which the device supported, a part of the
45 PIDs or all of them.
NOTE
2) Likewise, for "COMMAND: SET", the PID can only be selected in the range of which
the device supported as well, a part of the 28 PIDs or all of them.
6) You can carry out GET "STATUS-ID_MESSAGES" only if you perform GET " STATUS_
MESSAGES" first.
DMX-1000K--RX
Turn and press the Dial wheel to access DMX-1000K RX. The LCD window shows
you as follows and you can use the dial wheel to set the start channel.
1. Barchart Display >
2. Value Display >
3.
Min/Max Display >
< DMX 1000K RX:
< 1. Modify Channel >
2. Single Channel >
3. Color Mode >
4. Chase mode >
Turn and press the Dial wheel to access DMX-1000K TX. The LCD window shows you
as follows and you can use the dial wheel to set the channel value.
DMX-1000K--TX
The function and operation of DMX-1000K--RX Mode are similar to those of DMX Data--RX.
Please refer to the information of DMX Data--TX on page 7.
RDM TESTER
DMX DATA--TX
RDM CommanderRDM Commander
11
14
Turn the dial wheel to select the ">" of the third line right, you can select and set the
value for each parameter. There are 28 parameters available for "COMMAND: SET"
Turn the dial wheel to select the ">" of the first line right, you can swap "GET" and
"SET". To select "SET", the LCD show you as follows:
Turn the dial wheel to select the ">" of the second line right, you can select an unit ID
and view it.
Turn the dial wheel to select the ">" of the third line right, you can select and view the
details of each parameter. There are 45 parameters available for "COMMAND: GET"
< COMMAND: SET >
UID: XXXXXXXXX >
DMX_START >
ADDRESS
Turn the dial wheel to select the ">" of the second line right, you can select the unit
you want to set the command for it.
< 512 Channel
Modify = Each
Channel will hold
its preset value
Locate the label ? for more details. Help information shows as follows.
If you would like to set these 512 channels to be 000, use the Clear All function by
pressing the CLR> at the right of the first line.
You may also adjust the other 502 channels levels. Locate the cursor to > at the first
line of LCD, press the Dial wheel and turn it to the desired channels for new settings.
Remember that there are only 10 continual channels available for your choices every
time.
Turn the Dial wheel to select option. You can adjust the speed, channel,Single Channel
mode, level for your requirements when applying this function. The speed value can
be increased from 1 to 10. And there are 4 modes for reference, including Fade Only,
Auto On/ Off, Ramping, Stop.
2. Single Channel
Fade Only: Changing the channel value by Dial Wheel in the range of 0~255.
The LCD window usually shows the following diagram.
Ramping: The channel value will steadily increase one by one till to 255, complying
with the speed. Then repeat the sequence of 0 to 255.
Auto On/Off: The channel value will be changed between 000 and 255, complying
with the speed.
< Auto Speed : 01 > ?
Chan : 001 >
Mode: Fade Only >
Data : 000 = 00% >
The Speed function takes effect only when the mode is set as Auto On/Off or Ramping.
In this case, the level of the desired channel is adjusted automatically by this unit.
You can adjust the level by dial wheel when the mode is set to Fader Only. However,
there is only one channel level varied from the other 511 channels levels. And the
other 511 channels levels are 0.
Stop : The channel value can not be changed and held.
In addition, when the channel is set to be " 001 - 512 ( all ) ", you can set all the 512
channels to the same values.
< Total device: XX
>Device:
>Device_Inform
Get>
1). In the RDM system the RDM function of RDM Commander was used as a controller.
2). Total devices: Totally discovered RDM devices linked.
Device: The unit desired to operate.
Device inform: The properties of the unit.
Get: User can get or set command.
<
Found 0 RDM devices
Please exit!
Turn and press the Dial wheel to access GET or SET COMMAND function. If your unit
doesn't link to any RDM device, the LCD window will show you as follows:
If your unit discovered any RDM devices linking to your unit, the LCD window will
show you ,
< COMMAND: GET >
UID: XXXXXXXXX >
DEVICE_INFO: >
DMX DATA--TX RDM TESTER
RDM Commander
RDM Commander
13
12
4. Chase Mode
< 4. Chase Mode
Pixel: 8 Bit-1 color >
Total Pixel: 100 >
Pixel/Group: 001 >
Jump pixel: 001 >
Test Color: All >
Start Chan : 001 >
Master Level: 255 >
Auto Speed: 01 >
Fade Time:100% >
Cue:01 > Save Cue >
Manual Mode >
Go >
Manual Mode >
Go >
Turning the Dial wheel to select , you can test the DMX luminaires withChase Mode
multi channels. When accessing this option, the LCD window shows thefollowing
diagram.
Set the Auto Speed as 0, then user can modify the auto speed manually. The LCD window
shows the following diagram.
The data will change synchronously with each pressing of Go >. You can save it into a specific
The data will change synchronously with each pressing of Go. You can save it into a specific
number while you accessed " Save Cue" menu. This function can be done only NO DMX
number while you accessed " Save Cue" menu(Maximum 99 cues can be saved). This
signal input.
function can be done only NO DMX signal input.
Pixel: To select the 8 bit pixel or 16 bit pixel luminaires, each consists of 9 colors.
When selected the 16 bit luminaire, user can set the order of the Coarse channel and
Fine channel, by selecting System Setup menu, then selecting 1.DMX&RDM Setting
and 16bit:Coarse first/Finefirst to make setting.
Total Pixel: The maximum luminaries can be tested, user can set it in the range of 1
-512.
Pixel/Group: Set how many luminaires as a group according to the range of the Total
Pixel.
Jump Pixel: To set the number of luminaires each jump according to the range of
Pixel/Group.
Test Color: To select the properties of luminaires desired to test.
Start Chan: To set the start address of the DMX data chain in the range of 1-512.
Master Level: To set the maximum value of the DMX output in the range of 0-255.
Auto Speed: To set the changing speed of data in the range of 01-10.
Fade Time : To set the fade time ratio of data change in the range of 0-100.
Turn the Dial wheel to select and then press the Dial wheel to accessRDM Tester
this menu function. The LCD window usually shows as follows:
RDM Tester
3. Color Mode
< 2. Single Channel
512 data is same, or
one data is special
the others are zero
< 3. Color Mode ?
Pixel: 8Bit-1color >
Start Chan: 001 >
Master Level: 255 >
Auto Speed:01 >
Fade Time : 100% >
Cue:01 > Save Cue >
Turn the Dial wheel to select this function, the LCD window shows a message as follows:
Pixel: To select the 8 bit pixel or 16 bit pixel luminaires, each consists of 9 colors.
When selected the 16 bit luminaire, user can set the order of the Coarse channel and
Fine channel, by selecting System Setup menu, then selecting 1.DMX&RDM Setting
and 16bit:Coarse first/Finefirst to make setting.
Start Chan: To set the start address of the first pixel in the range of 1-512.
Master Level: To set the maximum value of the DMX output in the range of 0-255.
Auto Speed: To set the changing speed of data in the range of 01-10.
Fade Time : To set the fade time ratio of data change in the range of 0-100.
Locate the label ? for more details.
Set the Auto Speed as 0, then user can modify the auto speed manually. The LCD
window shows the following diagram.
Locate the label ? for more details. Help information shows as follows.
Cue:01> Save Cue>
Cue:01> Save Cue>
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Vari-Lite Showline SL RDM COMMANDER User manual

Category
DJ controllers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI