Vivint V-SH1 Setup Manual

Category
Security access control systems
Type
Setup Manual
SETUP GUIDE
Smart Hub
Panel
a
© 2016 Vivint, Inc. All rights reserved.
VivintanditsrespectivelogosareregisteredtrademarksortrademarksofVivint,Inc.intheUnitedStatesand
othercountries.Allothertrademarksarethepropertyoftheirrespectiveowners.
DISCLAIMER:Nopartofthismaterialmaybeexcerpted,reproduced,redistributed,published,broadcast,transmitted,translated,orutilized
inanyformorbyanymeans,electronic,mechanical,photocopying,recording,orotherwise,withoutpriorwrittenpermissionofVivint,Inc..
Vivintdoesnotwarrantthatthisdocumentiserrorfreeandretainstherighttomakechangestothisdocumentorrelatedproduct
specifications,drawings,anddescriptionsatanytimewithoutnotice.Vivintdoesnotassumeanyobligationtoupdatetheinformation
containedherein.Thisdocumentisprovided"ASIS"andwithoutanyguaranty,warranty,orlicense,expressorimplied,includingbutnot
limitedto:fitnessforaparticularpurpose,merchantability,non-infringementofintellectualproperty,orotherrightsofanythirdparty.
AnyVivintproductsreferencedinthisdocumentarenotintendedforuseinmedical,lifesaving,orlifesustainingapplications.
Thirdpartiesmayhaveintellectualpropertyrightsrelevanttothisdocumentandthetechnologiesdiscussedherein.
Setup Guide
Released:10/17/2016
DocumentPartNumberP/N:77-600017-001RevA.0
PanelPartNumberP/N:V-SH1
PanelComplianceModelNumberM/N:CP02
- 1 -
Contents
Contents 1
Introduction 3
About this Guide 3
SystemOverview 4
About the System 4
System Configuration Diagram 5
Control Panel Features 6
Control Panel Display Screens 10
SystemSetup 11
System Setup Outline and Summary 11
ConfigureSystemSettings 12
System Settings Configuration Outline 12
System Settings Complete List 13
Security Sensor Numbers and Types 14
Wireless Zones Configuration 17
Wired Zones Configuration 24
Key Fobs Configuration 28
Keypads Configuration 33
Entry and Exit Settings 36
Installer Settings 39
Key Fob Behavior Settings 42
Central Station Settings 43
Reporting and Troubles Settings 45
Emergency Buttons Settings 55
System Options Settings 56
System Registration Settings 59
Z-Wave Settings 60
Networking Settings 63
Cameras Settings 65
System Testing Settings 68
Cellular Settings 71
Sensor Bypass Settings 72
Bell Cutoff Settings 73
- 2 -
Update Settings 74
RegulatoryInformation 75
Where To Find Regulatory Compliance Declarations 75
FCC and IC Regulatory Compliance Declarations 76
Wireless Product Notice 77
Operating Temperature and Humidity Range Notice 77
Important Power Supply Notice 78
Internal Backup Battery Notice 78
Regulatory Notes 79
Applicable Warnings for Technicians 80
Default Settings for SIA CP-01-2014 Compliance 81
FCC and IC ID Numbers for System Devices 83
Fire Protection and Safety Information 84
Service and Warranty Information 88
Specifications 89
Introduction: About this Guide
- 3 -
Introduction
About this Guide
TheVivintSmartHub™panelisthehuboftheVivintSmartHomesystem,afully-supervised,integrated,and
intelligenthomesecurityandautomationsystem.
Thesystemwhichincludesthecontrolpanelandvarioussecuritysensorsandperipheraldevices
incorporatesthemostadvancedandsophisticatedfeaturesandtechnologyavailabletoday.Thesystemcanbe
expandedandcustomizedtofiteveryindividualhomeenvironmentandcustomerneed.
ThisguideprovidesanoverviewoftheentireVivintSmartHomesystem,informationabouthowthedifferent
componentsofthesystemworktogether,importantsafetystandardsandregulatorycompliancedeclarations,
andanoutlineoftheinstallation,setup,andsettingsconfigurationtasks.
Thefollowingtopicsarecoveredinthisguide:
l Learn about the control panelandoverallsystemfunctionality.
l Set up the control panelincludingplugginginthepowersupply,waitingforthepaneltobootup,andthen
followingtheonscreeninstructionsonthepanel'stouchscreendisplaythatstepsyouthroughtheprocess
ofaddingdevices(i.e.,sensors,cameras,etc.)andverifyingsuccessfuldeviceandpanelconnection.
l Configure system settingsforthepanel,securitysensors,andothersmarthomedevices.
NOTE:Somecitiesandmunicipalitiesmayrequireanalarmsystempermit.Checkwiththelocal
authoritiesbeforeinstallingthesystem.
IMPORTANT:AnychangesormodificationsnotapprovedbyVivintcouldvoidtheuser’sauthorityto
operatetheequipment.
Smart Hub Setup Guide
- 4 -
System Overview
About the System
ThissectionprovidesabriefsummaryofthemaincomponentsandfeaturesoftheVivintSmartHubsystem.
Control Panel
TheSmartHubpanelfeaturesacapacitive,colortouchscreendisplaythatallowscontrolofallsystemfunctions
andconfiguration.ThetouchscreendisplayshowstheVivintSmartHomeProtechnician(andthecustomer)
importantinformationsuchassystemanddevicestatus.Thecontrolpanelofferstouchnavigationthatmakes
systeminstallation,configuration,andoperationquickandeasy.
Thecontrolpanelhassystemsoftwareinstalledthatcanbeupdatedwiththelatestreleaseversionthatcan
includefeatureenhancements,fixes,andnewfunctionality.
Security Sensors
Thesystemcansupportupto100wirelesssensorsofvarioustypes(doorandwindowsensors,glassbreak
detectors,motiondetectors,etc.),aswellas20keyfobs,30keypads,and15sensorresponsetypes.
ThecontrolpanelreportssystemalarmsandtroublealertstotheVivintCentralStation(i.e.,MonitoringStation)
viaeithercellularorbroadbandIPnetworkcommunication.Two-wayvoicecommunicationbetweenthepaneland
theCentralStation(VivintLive)isalsoenabledthroughcellularcommunications.
A345MHznarrow-bandradioreceiverinsidethepaneldetectssignalstransmittedfromthewirelesssensors.
Z-Wave Devices
Thepanelhasabuilt-inZ-Waveradiomodulethatprovidessecure,encryptedcommunicationbetweenthepanel
andothersecurity-enabledZ-Wavedevices.Thepanel'sZ-Wavetechnologyallowsthecontrollingandmonitoring
ofvarioushomeautomationdevicessuchasdoorlocks,thermostats,andlightingcontroloutletmodules.
ThecontrolpanelwillworkwithanycompatibleZ-Wavedeviceregardlessofthemanufacturer.
User Accounts
TheVivintsystemsupports50useraccountsincludingasingleDuressUserandoneormoreAdminusers.The
Adminuserscanadd,delete,ormodifytheotherusers.NotethatalluserPINcodesmustbeunique.
TheInstallerPINcodeisassociatedwiththeonlyuseraccountthathasaccesstotheInstaller Toolboxscreens
(usedforconfiguringpanel,device,andsystemsettings).The default Installer PIN code is 2203.
Panel Buttons
ThepanelhasanEmergency buttonandaHome buttonthatfunctionasbothcontrolsandindicators.
Pressingthe buttonatanytimedisplaystheEmergencyscreenwithbuttonsforPanic,Emergency,andFire
alarmactivation(eachbuttonhasconfigurableoptionsandcanbeenabledanddisabledintheInstaller Toolbox).
Pressingthe buttonatanytimedisplaystheHomescreen.
System Overview: System Configuration Diagram
- 5 -
System Configuration Diagram
Thediagrambelowshowstheconfigurationofanoverallsystem—fortheVivintSmartHub™panel—andhow
itsvariouscomponentscommunicateandinteract,includingthecontrolpanel,userinputandinteractionfeatures,
internalmodules,wirelesssecuritysensors,NFC-readysensors(forDIYsetup),Z-Wavedevices,wireless
cameras,remoteaccessandcontroldevices(smartphone,tablet,laptop,etc.)viamobileandwebapps,power
supply,Wi-FicellularandbroadbandIPnetworks,andtheVivintPlatform.
Vivint Smart Hub Panel System
Smart Hub Setup Guide
- 6 -
Control Panel Features
ThefollowingdrawingsshowtwoviewsoftheSmartHubcontrolpanel,withsomeofthemainfeaturescalledout.
First,anexternalfrontview;andsecond,anexternalbackviewofthepanel.
Panel Front View
System Overview: Control Panel Features
- 7 -
Panel Back View
Smart Hub Setup Guide
- 8 -
System Status as Indicated by the Home Button Display
TheHomebuttonLEDcanindicatethestatusofsystemfunctionsandconditions,asdescribedbelow.
Secur ity Sensor Status
l GlowsGreenwhenallofthesensorsareclosedandthesystemisreadytoarm.
l Notlitwhenanysensorisopenandthesystemisnotreadytoarm.
Ar mi ng Status
l GlowsRedwhilethesystemisarmed(ineitherStayorAwaymode).
l FlashesRedduringtheEntryDelaytimeperiod.
Al arm Status
l FlashesRedduringanalarm.
l FlashesRedafteranalarmwhilesystemisstillarmed.
Power Outage Status (on Backup Battery Power)
l FlashesGreenwhenallofthesensorsareclosedandthesystemisreadytoarm.
l FlashesOrangewhenanysensorisopenandthesystemisnotreadytoarm.
l FlashesRedwhilethesystemisarmed(ineitherStayorAwaymode).
System Overview: Control Panel Features
- 9 -
Installer Toolbox Screens
IMPORTANT:ThecompletesetofInstaller ToolboxscreensisaccessibleonlytoaVivintSmart
HomeProstechnicianwhoenterstherequiredInstallerPINcode.
UsetheInstaller Toolboxscreenstoconfiguresystemsettings.TheVivintSmartHomeProtechnicianmust
enteravalidInstallerPINcodetoaccessthistoolbox.Themainscreendisplaysasetofsystemconfiguration
andtestingtools.Usethesetoolstoconfigureallofthesystemsettings,testsystemfunctionality,andreset
systemoptionstodefaultvalues(fordetails,see"ConfigureSystemSettings"onpage12).
FromtheHomescreen,presstheMenubutton>Settings>entertheInstallerPINcode(thedefaultcodeis
2203)>andthenpressInstaller Toolbox.
Smart Hub Setup Guide
- 10 -
Control Panel Display Screens
TheVivintSmartHubpanelisconfiguredandoperatedusingthetouchscreendisplay.Thedisplayshowscritical
systeminformationandprovidesaccesstothenumerousfeaturesusedtoconfigure,monitor,andcontrolthe
homesecurityandautomationsystembyboththeVivintSmartHomeProtechnicianandthehomeowner.
Thestatus baratthetopofthetouchscreenprovidesMenuaccess,andshowssysteminformationsuchasthe
dateandtimeandweatherinformation,aswellasstatusiconsforalerts,messages,power(AC/battery),and
sound.
Thenavigation baratthebottomofthetouchscreenshowsthesecuritymode,andprovidesaccesstothe
connecteddevicessuchasdoorlocks,thermostats,cameras,lightingcontrols,andmore.
TheMenubuttonintheupperleftcornerofthetouchscreenletsyouaccessthefollowingscreens:Emergency,
Settings(includingtheInstaller Toolbox),andSupport.
Home Screen
Atanytime,presstheHomebuttononthetouchscreentoreturntotheHomescreen.
System Setup: System Setup Outline and Summary
- 11 -
System Setup
System Setup Outline and Summary
Thefollowingoutlineprovidesahigh-levelsummaryofallthetasksthatcomprisethesetupofaVivintSmartHub
panelandsystem.
1. Unpack the box.
UnpacktheSmartHubpanelboxandidentifythecontents.Thepackageshouldcontainthecontrolpanel,
powersupply,quicksetupcard,(NOTE:Youcanunpacktheotherdevices,suchassensorsand
cameras,atthistimebutdonotinstallthemyet.)
2. Locate an unswitched outlet for the power supply.
Identifyanunswitchedwalloutletwhereyoucanpluginthepowersupplyforthecontrolpanel.
3. Plug the power supply into the wall outlet.
Plugthepowersupplyintothepreviouslyidentifiedunswitchedwalloutlet.
4. Connect the power supply to the control panel.
Connectthepowersupplycabletotheportonthebacksideofthepanel,andthentuckthecablesnugly
intotheslot.
5. Wait for the panel to start up.
Waitforthepaneltoloadthefirmwareandforthetouchscreeninterfacetoappear.Donotinstallorplace
theperipheraldevicesyet(sensors,cameras,etc.),astheinitialpartofthesystemsetupisdescribedon
thepanelitselfviaonscreeninstructions.Pleasewaitforthepaneltobootupfirst,andforthatinitialsetup
screentoappear.Thisprocessmaytakeafewminutes.
6. Follow the onscreen instructions to add and configure devices.
Oncethepanelisfinishedbooting,followtheonscreeninstructionsthatwillguideyouthroughaddingand
configuringdevices,andfinishingthepanelsetup.
(Formoredetails,seetheseparatedocumententitled"SkyHubPanelDIYOnscreenSetupInstructions")
Smart Hub Setup Guide
- 12 -
Configure System Settings
System Settings Configuration Outline
IMPORTANT:ThecompletesetofInstaller ToolboxscreensisaccessibleonlytoaVivintSmart
HomeProstechnicianwhoenterstherequiredInstallerPINcode.Thissectiondescribesthecomplete
setofsystemsettings(whichmaynotbeavailabletothecustomerviatheUserSettingsinterface).
AstheVivinttechnician,youconfiguresystemsettingsatthecontrolpanelviatheInstaller Toolboxscreens.
Everysystemyouinstallrequiresthatyouconfiguresettingsforcertaininstalledmodulesinthepanel,security
sensorsandotherperipheraldevices,inadditiontospecificsystemfeaturesservices.
Thissectiondescribeshowtoconfigurethesesystemsettings,andprovidesdetailedinformationabouteachof
thesettingsincludingdefaultvalues,functionality,andcompliancerequirementsfortheAmerican National
Standards Institute / Security Industry Association,ANSI/SIA CP-01-2014standard,hereafterreferredtoin
itsabbreviatedformasSIA CP-01-2014.
Somesystemsettingsarecommonacrossallinstallations(forexample,allcontrolpanelsreporttothesame
CentralStation).Othersettings,suchasaccountnumberandsensoranddeviceconfiguration,areuniquetoeach
installation.Followtheprocedurebelowtoguideyouthroughthesystemsettingsconfiguration.
To configure system settings
1. AtthepanelHomescreen,presstheMenubutton>andthenpressSettings.
2. EntertheInstallerPINcode(thedefaultcodeis2203).
3. PressInstaller Toolbox.
4. Tobeginconfiguringthesystem,pressZones, Key Fobs, Keypads,andthenpressWireless Zonesto
addandthenconfigurethewirelesssecuritysensorsthatareincludedinthisinstallation.
Formoreinformation,see"WirelessZonesConfiguration"onpage17.
5. Ifyou'reinstallinganywiredsensors,pressWired Zonestoaddandthenconfigurethosesensors.
Formoreinformation,see"WiredZonesConfiguration"onpage24.
6. Ifthesystemincludeskeyfobsand/orkeypads,addandthenconfigurethosedevices.
Formoreinformation,see"KeyFobsConfiguration"onpage28,and"KeypadsConfiguration"onpage33.
7. IMPORTANT:Keepinmindthateveryinstallationisunique—basedonthelocalnetwork,numberand
typeofsensorsandperipheraldevicesbeinginstalled,environmentalfactors,theresultingoptimalsystem
designandconfiguration,andotherconsiderations.Refertothecompletelistofsettingsbelowfor
informationabouthowtoconfigureeachcomponentandfeatureavailablefortheentiresystem.
Formoreinformation,see"SystemSettingsCompleteList"onthefacingpage.
8. Afterconfiguringallofthesettingsrequiredforthisinstallation,presstheHomebuttontoreturntothe
Homescreen.(NOTE:Allsettingschangesareautomaticallysavedinsystemmemoryinrealtimewhen
thechangeismade.)
Configure System Settings: System Settings Complete List
- 13 -
System Settings Complete List
Usethelistbelowasaquickreferencetodetailedinformationaboutallofthesystemsettings.
Toaccessthesecuritysensorandremotecontroldevicesettingsfromthecontrolpanel,goto:
Menu > Settings > Installer Toolbox > Zones, Key Fobs, Keypads
Andthenselectfromthefollowing:
l "WirelessZonesConfiguration"onpage17
l "WiredZonesConfiguration"onpage24
l "KeyFobsConfiguration"onpage28
l "KeypadsConfiguration"onpage33
Formoreinformationaboutconfiguringsensors,see"SecuritySensorNumbersandTypes"onthenextpage.
Toaccessallothersystemsettings,goto:
Menu > Settings > Installer Toolbox
Andthenselectfromthefollowing:
l "EntryandExitSettings"onpage36
l "InstallerSettings"onpage39
l "KeyFobBehaviorSettings"onpage42
l "CentralStationSettings"onpage43
l "ReportingandTroublesSettings"onpage45
l "EmergencyButtonsSettings"onpage55
l "SystemOptionsSettings"onpage56
l "SystemRegistrationSettings"onpage59
l "Z-WaveSettings"onpage60
l "NetworkingSettings"onpage63
l "CamerasSettings"onpage65
l "SystemTestingSettings"onpage68
l "CellularSettings"onpage71
l "SensorBypassSettings"onpage72
l "BellCutoffSettings"onpage73
l "UpdateSettings"onpage74
Smart Hub Setup Guide
- 14 -
Security Sensor Numbers and Types
Eachsecuritysensorinstalledaspartofthesystemwhetherwirelessorwired—isconfiguredtocorrespondto
aspecificsensor numberandsensor type (i.e., zone).
Sensor Numbers
Thesensor numberidentifiesthespecificsensor,andisusedwhenthesensoris:
l displayedonthecontrolpanel
l recordedintheeventlog
l reportedtotheCentralStation
Thisprovidespreciseinformationabouteverysecuritysensorinthesystem.
Sensor Types
Thesensor type(sometimesreferredtoasasensorzone)determineshowandwhenthecontrolpanelresponds
tosignalsfromthesensor.Somesensorsarearmedallthetime,othersarearmedonlyincertainarminglevels,
andsomesensorscauseCentralStationreportsanytimetheyareactivated.Thesensortype,alongwithother
configurationoptions,determinethisbehavior.
Thefollowinglistdescribeseachofthesensortypes/zones.
(00) Unused
Thisisthesettingforunusedsensornumbersthatdonothaveasensorconfiguredintothem.Nosystemaction
occursatanytimefromthissensortype.
(01) Exi t/Entry 1
Thissensortypeisreservedfordoorsthatareusedforexitandentry.WhenthesystemisarmedintheAway
ModeorStayMode,theExitDelaytimerstarts.ThereisanExitDelayregardlessofwhetherthesystemisarmed
inStayModeorAwayMode.WhentheExitDelaytimerexpires,thesystemisfullyarmed.
Withthesystemfullyarmed,whenthistypeofsensoristriggered,theEntryDelay#1timerstarts.Thesystem
mustbedisarmedbeforetheEntryDelay#1timeexpires,oranalarmwilloccur.
IftheEntryDelayisturnedoffbydisablingEntryDelayfromtheArmingscreenwhenarmingthesystem,theexit/
entrydelaysensorswillinstantlytriggeranalarmaftertheendofExitDelay(whenthesensoristriggered).
(02) Exi t/Entry 2
ThissensortypeoperatesthesameastheExit/Entry1sensortypeexceptitwillstarttheEntryDelay#2timer.
ThisprovidesamethodofhavingalongerEntryDelayoncertainopenings,suchasagaragedoor,toprovidethe
usermoretimetodisarmthesystem.
(03) Per imeter
Thissensortypeisforsensorsthatprotecttheperimeterofthepremises,suchasawindowsensor.Perimeter
sensorsinstantlytriggeranalarmwhenopenedwhilethesystemisarmedawayorstay.
Configure System Settings: Security Sensor Numbers and Types
- 15 -
(04) Interior Fol l ower
Thissensortypeisforinteriorsensorssuchasmotiondetector,interiordoors,andothersensorsthatdetect
humanpresenceinsidetheprotectedarea.Thistypeofsensoriscalleda"follower"duetoitsactionwhenthe
systemisarmedintheAwayMode.AftertheExitDelayexpiresandthesystemisarmed,ifaninteriorfollower
sensoristriggered,aninstantalarmwilloccur.
InteriorfollowersensorsarealwaysbypassedandnotactivewhenthesystemisarmedinStayMode.This
allowstheprotectedareatobeoccupiedwhilestillprotectingtheperimeter.
(05) Day Zone
Thissensortypeisthesameasaperimeterzone,exceptwhenthesystemisdisarmed,openingthesensor
displaysatroublealertonthecontrolpaneldisplay.Commonusesforthissensortypeareprotectionofsensitive
areasthatrequirenotificationandpossiblyaCentralStationtroublereport,butnotanalarmwhenthesystemis
disarmed.
(06) 24-hour Sil ent Al arm
Thissensortypeisactiveindependentofthesystemarmingstatus.Thecodeforsilentpanicissenttothe
CentralStation,butforsafety,therearenovisualoraudibleindicationslocallythatthissensortypehasbeen
triggered.
(07) 24-hour Audi ble Alarm
Thissensortypeiscontinuouslyarmed24-hoursaday.Asensorconfiguredtothistypewilltriggeralocalalarm
andtheexternalsirenregardlessofthemodethesystemisin.Typicaluseofthissensortypewouldbeanaudible
panicalarm.
(08) 24-hour Auxi liary Alarm
Thissensortypeiscontinuouslyarmed24-hoursaday.Asensorconfiguredtothistypewilltriggeranalarm
regardlessofthemodethesystemisin.Theexternalsirenwillnotactivate,butthelocalsounderwillcontinue
untilit’sacknowledgedatthecontrolpanel.Typicalusewouldbeforamonitoringdevicesuchasafloodor
temperaturesensor.Thereisnotimeoutfortheinternalsounder,itwillcontinueuntilauserPINcodeisentered.
(09) 24-hour Fir e **
Thissensortypeiscontinuouslyarmed24-hoursaday.Asensorconfiguredtothistypewilltriggerthelocalalarm
firesounderandtheexternalsirenregardlessofthemodethesystemisin.Typicalusewouldbeforwireless
smokedetectors.Thissensortypeisalwaysactiveandcannotbebypassed.
(10) Interior wi th Delay
ThissensortypeoperatesasadelayedsensorwhenthesystemisarmedintheAwayMode,andwhentriggered,
willstarttheEntryDelay#1timer.IfthesystemisarmedinAwayModewithnoEntryDelay(armedinstant),this
sensortypewilltriggeraninstantalarm.
IfthesystemisarmedinStayMode(orStayModewithnoEntryDelay),thissensortypewillbebypassed.
(14) 24-hour Carbon Monoxi de **
Thissensortypeiscontinuouslyarmed24-hoursaday.Asensorconfiguredtothistypewilltriggerthelocalalarm
pulsesounderandtheexternalsirenregardlessofthemodethesystemisin.Typicalusewouldbeforwireless
carbonmonoxidedetectors.Thissensortypeisalwaysactiveandcannotbebypassed.
Smart Hub Setup Guide
- 16 -
(16) 24-hour Fir e with Veri f ication **
Thissensortypeiscontinuouslyarmed24-hoursaday.Asensorconfiguredtothistypecantriggerthelocalalarm
firesounderandtheexternalsirenregardlessofthemodethesystemisin.Typicalusewouldbeforwireless
smokedetectors.Thissensortypeisalwaysactiveandcannotbebypassed.
Forverification,thissensortypemustbeviolatedtwiceintwominutes,orremainviolatedfor30seconds.Ifany
otherfiresensor(verifiedsensortypeornot)violateswithintwominutes,bothsensorswillcauseafirealarm.
(23) No Response Type
ThissensortypeisaspecialzonethatcanbemonitoredforactivityorinactivitybytheCentralStation.Itdoesnot
affectsecuritysystemstatus.
(24) Sil ent Burglary
Thissensortypeisforsilenttriggeringtheburglaryalarmwithperimeterdoorsandwindowsthatwillnotbeused
toenterorexittheprotectedareawhilethesystemisarmed.Thecontrolpanel’salarmsounderandtheexternal
sirenwillnotactivate.
AninstantsilentalarmwilloccurwhenthistypeofsensoristriggeredwiththesystemarmedineithertheStay
ModeorAwayMode.
(25) Repeater
ThissensortypeisforrepeatermodulesthatconsistofbothanRFreceiverandtransmitterandthatareusedto
extendtherangeofwirelessdevicesintheeventtheyarelosingpanelsupervision.
**Indicatessensortypesthatarenotallowedtobeusedwiththehardwireloops.
Configure System Settings: Wireless Zones Configuration
- 17 -
Wireless Zones Configuration
Thissectioncontainsdescriptions,defaultvalues,andnotesabouttheWirelessZonessettings.
Toaccessthesesettingsfromthecontrolpanel,goto:
Menu > Settings > Installer Toolbox > Zones, Key Fobs, Keypads > Wireless Zones
List of Settings
Theoptionsthatcanbesetforeachwirelesssensorincludethefollowing(seebelowthislistfordetailed
descriptions):
l Equipment Code: Sensormodel(door/windowsensor,PIRmotionsensor,smokedetector,etc.).
l Other Equipment Code: Enterspecialequipmentcode(onlyshownforsensorssetas"Other").
l Sensor Type: Exit/entry,perimeter,interior,etc.
l Equipment Type: Certainsensortypeswillaskforequipmenttype(seethelistbelow).
l TXID: TXIDnumberlabeledonthesensor(manuallyenterorlearnin).
l Loop: Built-incontactsorexternalcontactsondoor/windowsensor.
l Voice Descriptor: Selectthewordsthepanelvoiceusestodescribethesensor.
l Name: Nameassignedtothesensorthatisusedforvoiceannunciationandinuserinterfaces.
l Chime: Enableanddisablethechimeoptionforthesensor.
l Chime Tone:Selectfromtheavailabletonesforthechime.
l Voice:Enableanddisablethevoiceoptionforthesensor.
l Dialer Delay: Delayedorinstantcommunicatorreportsforthesensor(delaytimeissetbydialerabort
window.)
l Reports: Communicatorreportsornocommunicatorreportsforthesensor.
l Supervised: Panelchecksforstatusreportsfromthesensor,ordoesnotcheckforstatusreports.
l Equipment Age: Identifiesthesensoraseitheranewdevice(i.e.,addedduringtheinitialinstallation)or
anexistingdevicethatwaspreviouslyinstalledinthesystem.
l Zone Number: Selectanumberfrom01to100.
l Secure Mode: Indicateswhetherthesensorhasbeenconfiguredwithanti-theftsecurityencryption.
l 32 Bit ID: Automaticallyassignedidentificationnumberforsensorsthatareencryptedwithanti-theft
security.
l Battery Life: Indicatesthepercentageofpowerremaininginthesensor'sbattery.
l Battery Level: Showsthelevelofvoltageremaininginthesensor'sbattery.
l Last Battery Measurement Time: Showsthedateandtimeofthemostrecentsignalfromthesensorthat
providedinformationaboutthestatusofthesensor'sbattery.
Smart Hub Setup Guide
- 18 -
l Battery Threshold: Whenthesensor'sbatterylevelfallsbelowthisvalue,alowbatterysignalwillbe
sentfromthesensortothepanel.
l Cold Climate: Enableanddisablethecoldclimateoptionforthesensor'sbatterythataccountsfora
colderenvironmentandpreventsfalse(i.e.,inaccurate)reportsofalowbatterysignalsentbythesensorto
thepanel.Forexample,ifyouinstallthesensorinacoldclimate,oranywhereinthehomewhereitis
typicallycolderthannormal,thesensormighttransmitsignalsindicatingthebatterylevelislowerthanit
actuallyis.Thisoptionletsyoupreventthosefalsereportsbyenablingadifferentformulaformeasuring
thebatterylevel.
l Cold Climate Season (in days): Letsyoucustomizethedurationofthecoldclimateseasonby
specifyingthenumberofdays.
l Single RF Quiet Chatter: Eliminatessignalchattercreatedwhenbothanindividualsensorandarepeater
devicesendredundantsignalstothepanel.
Wireless Sensor Equipment Code
Theequipmentcodeisa4-digitcodethatisassignedtothemodelofsensorbeingused.Thecontrolpanel
displaysalistofsensormodelsandtheirassociated4-digitequipmentcode.
1. Selectthemodelofwirelesssensorbeingconfiguredforthissensornumberbyselectingtheequipment
codefromthelistorbyenteringtheequipmentcodenumberdirectlyonthekeypad.
NOTE:Whenyouselectthesensor'sequipmentcode,defaultvaluesforsomeofthesensor'sother
optionsareautomaticallyset.Makesuretoconfirmthatthedefaultsettingsmatchthedesired
configuration.
2. Ifthesensormodelisnotinthelist,select(0000) Other.Theequipmentcodeforthissensorcanbe
enteredusingtheresultingsub-option,calledtheOther equipment code.
Wireless Sensor Equipment Codes
(0000)Other (2081)RPTR1-345VivintRepeater
(1251)DW11Door/Window(NGP device) (1144)RE220T2GIGRepeater
(1252)DW21RRecessedDoorContact(NGP device) (0655)ExistingDoor/WindowContact
(1249)PIR2MotionDetector(NGP device) (0609)ExistingMotionDetector
(1248)GB2GlassBreakDetector(NGP device) (0475)ExistingGlassBreakDetector
(1253)PANIC2PanicPendant(NGP device) (0616)ExistingSmokeDetector
(1058)SMTK3SmokeDetector (0708)ExistingHeatSensor
(1026)2GIGCODetector (0692)ExistingCODetector
(1061)GARAGE01RPTiltSensor (0556)ExistingFlood/TempSensor
(1063)DBELL12GIGDoorbell (0862)DW10ThinDoor/Window
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Vivint V-SH1 Setup Manual

Category
Security access control systems
Type
Setup Manual

Ask a question and I''ll find the answer in the document