M968628

American Standard M968628 User manual

  • Hello! I am an AI chatbot trained to assist you with the American Standard M968628 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
Teflon Tape
Certified to comply with ANSI A112.18.1
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
PRESSURE BALANCING
BATH AND SHOWER
TRIM KITS
M968628 REV.1.3
THREADED INLETS (STOPS)
INLETS
1/2" NPT
5-7/8"
INLETS 1/2" NPT
OUTLETS
1/2" NPT
OUTLETS
1/2" NPT
3-3/8"
3-3/8"
3-3/8"
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
4-1/16"
5-7/8"
INLETS
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
SWEAT
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
T590.50X
Installation
Instructions
1-5/8" TO 3-1/4"
BOTTOM OF
TUB
74" FOR
HEAD
CLEARANCE
1/2" NPT
FINISHED WALL
OPTIONAL TO
FINISHED FLOOR
USUALLY
BETWEEN
80'' AND 86'
4"
4-3/4"
1/2" COPPER
18"
OPTIONAL
"SEE ILLUSTRATION"
TOP OF
TUB RIM
TUB
SHR
8-1/4"
2-3/8"
STUDIO
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
6-11/16"
1" MIN.
4-1/2"REF.
7-1/2" REF.
2-3/8"
4-7/8" REF.
8-1/2" REF.
M968628 REV.1.3
3
4
5
6
Figure 3.
1
5
7
1
INSTALL VALVE TRIM
1
Figure 1.
Figure 2.
2
1
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Make sure O-RING (8) is secure within
ESCUTCHEON HOLDER (3). Push ESCUTCHEON HOLDER
(3) onto CAP (1) and attach with LONG SCREWS (4).
Mount ESCUTCHEON SUPPORT (5) to ESCUTCHEON
HOLDER (3) with 4 SHORT SCREWS (6).
Figure 3. Install ESCUTCHEON (7) onto CAP (1) and push
flush against finished wall. Escutcheon (7) will snap fit onto
ESCUTCHEON SUPPORT (5).
PLSTER
GUARD
Remove pipe cap and plug from shower and tub
rough piping.
Install TUB SPOUT (1) onto tub nipple.
CAUTION: Protect finish on TUB SPOUT when
installing.
Install SHOWER ESCUTCHEON (2) onto SHOWER
ARM (3). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (3) and thread longer
leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
PIPE
PLUG
2
INSTALL DIVERTER KNOB, TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
Install HANDLE (5) onto CARTRIDGE STEM (6). Tighten
SET SCREW (7) with HEX WRENCH (8) supplied.
PIPE
CAP
SHR.
ELBOW
1
5
7
8
6
TUB FILLER
NIPPLE
3
4
1" MIN.
2
8
M968628 REV.1.3
CARTRIDGE
INLETS
2
3
5
1
4
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust
the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B"
to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
SERVICE
4
Remove HANDLE (1), CAP (2) and CARTRIDGE (4).
Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from "off" to "on". Do
not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on"
hot or cold. To clean inlets, first turn off water supply, then:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
/