American Standard T440507.295 Installation guide

Category
Sanitary ware
Type
Installation guide
BOTTOM OF TUB
4-13/16" REF.
(121mm) REF.
1/2" COPPER
9-3/16"
(233mm)
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' (1651mm)
AND 80'' (1880mm)
TOP OF TUB RIM
Certified to comply with ANSI A112.18.1
Recommended Tools
Flat Blade Screwdriver
Plumbers' Putty or CaulkingPhillips Screwdriver
ROUGHING-IN DIMENSIONS
Installation for Bath/Shower, Shower only, or
Valve only Trim.
Dimensions are for reference.
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
INSTALLATION
INSTRUCTIONS
T440.507
T440.508
QUENTIN™
BATH/SHOWER TRIM KITS
M965429
C
H
1-5/8" TO 3"
(41mm TO 76mm)
FINISHED WALL
4" (102 mm)
74" FOR HEAD
CLEARANCE
(188 cm)
18" OPTIONAL
(457mm)
1/2" NPT
(12,7 mm) NPT
216mm
(8-1/2")
REF.
125mm
(4-7/8")
REF.
1-1/2" REF.
(38mm) REF.
INLETS 1/2" NPT
OUTLETS
1/2" NPT
3-3/8"
(98mm)
3-3/8"
(98mm)
THREADED INLETS (STOPS)
INLETS
1/2" NPT
OUTLETS 1/2" NPT
3-3/8" (98mm)
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
4-1/16"
(103mm)
4-1/16"
(103mm)
5-7/8"
(149mm)
5-7/8"
(149mm)
INLETS
4-1/16"
(103mm)
INLETS
1/2" NOM.
COPPER
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
(51mm)
SWEAT
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
"SEE ILLUSTRATION "
Adjustable Wrench
Channel Locks
Teflon
Tape
PIPE
CAP
1
PIPE PLUG
TUB FILLER
NIPPLE
1-1/2" REF.
Remove pipe cap and plug from shower and tub
rough piping.
Slip TUB SPOUT (1) onto tub nipple and tighten with
4mm Hex Wrench.
Apply Teflon Tape to both ends of SHOWER ARM (2).
Install SHOWER ARM (2) with FLANGE (3) into shower pipe and tighten.
Thread SHOWER HEAD (4) onto ARM (2) and tighten.
Push SHOWER ARM FLANGE (3) to wall and tighten SET SCREW (5)
with 5/64” hex wrench.
2
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
4MM HEX
WRENCH
SHR.
ELBOW
INSTALL VALVE TRIM
1
5
4
6
(4) ALIGNMENT
HOLES FOR
DIAL PLATE
1
2
3
When finished tiling the wall, remove PLASTER GUARD (1)
and turn off water supply.
Push CAP (2) over VALVE CARTRIDGE (3).
Mount ESCUTCHEON (4) to valve body with SCREWS (5).
Push DIAL PLATE (6) over CAP (2) and into the four alignment
holes in ESCUTCHEON (4).
M965429
C
H
C
5
2
3
HEX
WRENCH
TEFLON TAPE
SERVICE
5
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
If faucet drips, operate handle several times from "off"
to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
5
4
3
2
1
6
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
1
2.5MM HEX
WRENCH
4
HANDLE INSTALLATION
3
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2)
and tightening SET SCREW (3) from below with 2.5mm
Hex Wrench supplied.
2
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
M965429
C
MODEL NUMBER
M950267-YYY0A
DIVERTER SPOUT (SLIP-ON)
M909623-YYY560A
DIAL PLATE
M962255-YYY0A
ESCUTCHEON AND SCREWS
M907050-YYY0A
CARTRIDGE CAP
078016-YYY0A
ESCUTCHEON SCREWS
M964158-YYY0A
LEVER HANDLE KIT
BATH/SHOWER
TRIM KITS
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2012
HOT LINE FOR HELP
C
H
T440.507
T440.508
QUENTIN™
Replace the "YYY" with
appropriate finish code
CHROME
OIL RUBBED BRONZE
SATIN NICKEL
002
224
295
M965429
1660113-YYY0A
SHOWER HEAD
060351-YYY0A
SHOWER ARM AND FLANGE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Standard T440507.295 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI