Commissioning
The module is strted for the
first time
Light emitting diode (LED) 1 flshes t
intervls of 1 second s the module
scns for network.
LEDs 2 nd 3 re turned off.
The module hs found
coordintor nd is connected
to this
LED 1 flshes every third second
indicting tht the module is in
”identify mode”. In this mode, the
module communictes ctively with
the network.
15 minutes fter connecting the
module to the coordintor
LEDs are turned off.
Pulse inputs
The module hs two pulse inputs which
cn be used for totliztion of pulses
from wter nd gs meters. Pulse
resolutions nd units re utomticlly
configured on the bsis of MULTICAL®.
Terminl 65 Pulse input A/In-A (+)
Terminl 66 Pulse input A/In-A (-)
Terminl 67 Pulse input B/In-B (+)
Terminl 68 Pulse input B/In-B (-)
Ordering
The module cn be mounted in the
following meters:
MULTICAL® 66
MULTICAL® 61
MULTICAL® 601
MULTICAL® 602
Single module:
670060000000.E
Module in MULTICAL® 61/601/602:
670060000000.0
Light
emitting
diodes
1-3
Pulse
inputs
The
module’s
MAC
ddress
Push
button
Light
emitting
diode 3
Light
emitting
diode 2
Link
sttus
Optiml
> Norml
Norml
< Norml