Chaska 29

kozy heat Chaska 29 Operating instructions

  • Hello! I'm your chat assistant. I have reviewed the provided document for the Chaska CSK-29 direct vent insert. This document outlines crucial installation details, including gas and electrical access, mantel clearances, and venting requirements. I am ready to answer your questions about this product and its installation.
  • Where is the gas line opening located?
    Where is the electrical access located?
    What is the minimum vertical venting requirement?
Please leave these reference guides at the installaon locaon unl the installaon is nished. See owners manual for full installaon and nishing
instrucons before making nal decisions as informaon is subject to change.
Specicaons (all measurements are in inches)
Exisng Fireplace Requirements
Dimension CSK29
A191/4
B291/2
C15
D187/8
Shroud Sizes*
Dimension #CK292538 #CK2927542
K25 271/2
L38 42
#CK293044
30
44
Venng Requirements
Chaska29Direct Vent Insert
Consult manual for
approved venng
manufacturers
GAS LINE OPENING: RIGHT SIDE ELECTRICAL ACCESS: LEFT SIDE
ModelBTUFrontHeightFrontWidthBackWidthDepthGlassViewingArea
CSK29 30,500 (NG) 191/4 291/2 187/8 141/2 257/8 x 125/8
BackHeight
141/8
Mantel Clearances
Requirement CSK29
(NG/LP) Vercal Min 10 .
(NG/LP) Vercal Max 50 .
K
L
Shroud Part Number
A
B
C
D
V
*Custom Sizes also available
V = Vercal
MIN
MAX
V
10 . min
E
F
45o
9”
6”
GH
I
J
Combusble Mantel
Combusble Mantel
Low Mantel Kit must be installed
(part #CK29LMK)
45o
Ceiling
ALL screen front
installaons
Clearances outlined in this drawing are
for installaons with screen fronts
#CK29RSF & #CK29PSF ONLY
All other screen front installaons must
follow the clearances outlined here
Dimension CSK29
E11
F14
Dimension CSK29
G55
H16
Dimension
I
J
CSK29
351/4
371/4
9”
11”
8/19
/