Remote Automation Solutions V-Cone Metering Program (For ROC800) Owner's manual

Type
Owner's manual
Remote Automation Solutions
Form A6149
Part Number D301193X012
June 2016
V-Cone
®
Metering Program User Manual
(for ROC800-Series)
V-Cone Metering Program User Manual (for ROC800-Series)
ii Revised June-2016
Revision Tracking Sheet
June 2016
This manual may be revised periodically to incorporate new or updated information. The revision date
of each page appears at the bottom of the page opposite the page number. A change in revision date to
any page also changes the date of the manual that appears on the front cover. Listed below is the
revision date of each page (if applicable):
Page
Revision
All Pages
June-2016
All Pages
October-2013
All Pages
May-2012
All Pages
October-2011
ii, 1, 5, 6
April-2004
Initial Issue
September-2003
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 iii
Contents
Chapter 1 Introduction 1
1.1 Scope and Organization ................................................................................................................ 1
1.2 Product Overview .......................................................................................................................... 1
1.3 Program Requirements ................................................................................................................. 2
1.3.1 License Keys .................................................................................................................... 3
Chapter 2 Installation 5
2.1 Installing the License Key.............................................................................................................. 5
2.1.1 Verifying the License Key Installation .............................................................................. 6
2.2 Downloading the V-Cone Program ............................................................................................... 7
2.3 MPU Loading Threshold .............................................................................................................. 10
Chapter 3 Configuration 13
3.1 V-Cone Configuration Screen ..................................................................................................... 14
3.2 Station Setup ............................................................................................................................... 16
3.3 Orifice Meter Setup ..................................................................................................................... 16
3.4 Orifice Values .............................................................................................................................. 18
3.5 Saving the Configuration ............................................................................................................. 19
Chapter 4 Reference 21
4.1 Point Type 61/71: V-Cone Metering Configuration ..................................................................... 22
V-Cone Metering Program User Manual (for ROC800-Series)
iv Revised June-2016
[This page is intentionally left blank.]
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 1
Chapter 1 Introduction
This chapter describes the structure of this manual and presents an
overview of the V-Cone
®
Metering program for the ROC800-Series
Remote Operations Controller (ROC800).
1.1 Scope and Organization
This document serves as the user manual for the V-Cone Metering user
program, which is intended for use in ROC800. This manual describes
how to download and configure the V-Cone Metering user program
(referred to as the “V-Cone program” or “the program” throughout the rest
of this manual). You access and configure the program using ROCLINK
800 Configuration Software (version 2.00 or greater) loaded on a personal
computer (PC) running Microsoft
®
Windows
®
2000 (with Service Pack 2),
Microsoft Windows XP, Microsoft Windows Vista™, or Microsoft
Windows 7 (32-bit or 64-bit).
The sections in this manual provide information in a sequence appropriate
for first-time users. Once you become familiar with the procedures and the
software running in a ROC800, the manual becomes a reference tool.
This manual has the following major sections:
Section 1 – Introduction
Section 2 – Installation
Section 3 – Configuration
Section 4 – Reference
This manual assumes that you are familiar with the ROC800 units and
their configuration. For more information, refer to the following manuals:
ROC800-Series Remote Operations Controller Instruction Manual
(part D301217X012).
ROCLINK 800 Configuration Software User Manual (for ROC800-
Series) (part D301250X012).
1.2 Product Overview
The V-Cone program allows a ROC800 to calculate a corrected
volumetric flow rate at a specified base pressure and temperature for a
McCrometer V-Cone or Wafer-Cone flowmeter. The V-Cone or Wafer-
Cone flowmeter is very similar to an orifice plate calculation, uses many
of the same configuration parameters, and produces many of the same
calculated values. For this reason, the user program makes use of existing
orifice meter run points already provided by the ROC800 firmware. In
addition to the standard orifice point parameters, the ROC800 also
calculates an actual volumetric flow rate, a fluid velocity, a thermal
expansion factor, and the percent pressure loss in accordance with the
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 2
McCrometer specification McCrometer Flow Calculations for the V-Cone
Flowmeter, October 2002.
As part of the V-Cone program point configuration, you assign the V-
Cone or the Wafer-Cone calculation to an orifice meter point. When the
calculation is assigned, the standard AGA3 calculation is bypassed and the
McCrometer calculation is performed instead. All standard orifice
parameters, as well as the additional V-Cone program parameters, are
available for assignment to Modbus registers, PID control loops, historical
archiving, and FST and DS800 database functions.
1.3 Program Requirements
The V-Cone program version 1.11 is compatible with ROC800-Series 2
firmware version 3.30 (or greater), ROC800-Series 1 firmware version
2.16 (or greater), ROC800L firmware version 1.20 (or greater), and with
version 2.00 (or greater) of ROCLINK 800 configuration software. The
program requires you to install an AGA 3/7/8 hardware-based license key
to enable the calculations, and a V-Cone license key to enable the user
program.
Notes:
Two versions of the program are included. Installation and operation
are identical between the two programs, but they use different point
type locations, different display numbers. V-Cone.61.tar uses point
types 61 and uses display 61. V-Cone.71.tar uses point types 71 and
uses display 71. Install the program version that avoids point type
conflicts with currently installed programs.
The installation process and functionality is the same for all versions
of the V-Cone program.
Program specifics include:
File Name
Target
Unit/
Version
User Defined
Point (UDP)
Flash Used
(in bytes)
SRAM Used
(in bytes)
DRAM
Used (in
bytes)
ROCLINK
800
Version
Display
Number
V-Cone.61.tar
ROC800-
Series 2
v. 3.30
61 16151 408 73728 2.00 61
ROC800-
Series 1
v. 2.16
V-Cone.71.tar
ROC800-
Series 2
v. 3.30
71 16151 408 73728 2.00 71
ROC800-
Series 1
v. 2.16
For information on viewing the memory allocation of user programs, refer
to Section 7.7 of the ROCLINK 800 Configuration Software User Manual
(for ROC800-Series) (part D301250X012).
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 3
1.3.1 License Keys
License keys, when matched with valid license codes, grant access to
applications such as the V-Cone program. An AGA3/7/8 license key must
be present to provide the required number of meter runs, and a separate
license key is also required to enable the V-Cone user program.
The term “license key” refers to the physical piece of hardware that can
contain up to seven different licenses (refer to Figure 1–1). Each ROC800
can have none, one, or two license keys installed. If you remove a license
key after enabling an application, the firmware disables the task from
running. This prevents unauthorized execution of protected applications in
a ROC800.
Figure 1-1. License Key
DOC0422A
J1
U1
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 4
[This page is intentionally left blank.]
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 5
Chapter 2 Installation
This section provides instructions for installing the V-Cone program into
the ROC800. Read Section 1.3 of this manual for program requirements.
Notes:
The computer running ROCLINK 800 must be connected to the Local
Operator Interface (LOI) port before you begin the download.
The program and license key can be installed in any order. The manual
shows the installation of the license key first.
The installation process and functionality is the same for all versions
of the V-Cone program.
2.1 Installing the License Key
If you order the V-Cone program for a new ROC800, your ROC800 is
delivered with the license key installed. Go to Section 2.2. If you order the
program for an existing ROC800, you must install the license key
yourself.
Caution
Failure to exercise proper electrostatic discharge precautions, such as
wearing a grounded wrist strap may reset the processor or damage
electronic components, resulting in interrupted operations.
When working on units located in a hazardous area (where explosive
gases may be present), make sure the area is in a non-hazardous state
before performing these procedures. Performing these procedures in a
hazardous area could result in personal injury or property damage.
To install a license key:
1. Remove power from the ROC800.
2. Remove the wire channel cover.
3. Unscrew the screws from the Central Processing Unit (CPU) faceplate.
4. Remove the CPU faceplate.
5. Place the license key in the appropriate terminal slot (P4 or P6) in the
CPU.
Figure 2-1. License Key Installation
Note: When using a single license key, install it in slot P4.
DOC0423A
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 6
6. Press the license key into the terminal until it is firmly seated (refer to
Figure 2–1).
7. Replace the CPU faceplate.
8. Replace the screws on the CPU faceplate.
9. Replace the wire channel cover.
10. Restore power to the ROC800.
2.1.1 Verifying the License Key Installation
After you install the license key, you can verify whether the ROC800
recognizes the key. From the ROCLINK 800 screen, select Utilities >
License Key Administrator. The License Key Administrator screen
displays:
Figure 2-2. License Key Administrator
V-Cone appears in the Application Name column. For further information
on the License Key Administrator screen, refer to Section 2.4 of the
ROCLINK 800 Configuration Software User Manual (for ROC800-Series)
(part D301250X012).
After you verify that the license key is correctly installed and recognized,
proceed to Section 2.2 to download the user programs.
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 7
2.2 Downloading the V-Cone Program
This section provides instructions for installing the V-Cone program into
the Flash memory on the ROC800.
Note: Connect a PC to the ROC’s LOI port before starting the download.
To download the user program:
1. Select any empty program number (in this case, number 1) into which
to download the program:
Figure 2-3. User Program Administrator
2. Click Browse in the Download User Program File frame. The Select
User Program File screen displays (see Figure 2–4).
3. Select the path and user program file to download from the CD-ROM.
(Program files are typically located in the Program Files folder on the
CD-ROM.) As Figure 2–4 shows, the screen lists all valid user
program files with the .TAR extension:
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 8
Figure 2-4. Select User Program File
11. Click Open to select the program file. The User Program
Administrator screen displays. As shown in Figure 2–5, note that the
Download User Program File frame identifies the selected program
and that the Download & Start button is active:
Figure 2-5. User Program Administrator
12. Click Download & Start to begin loading the selected program. The
following message displays:
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 9
Figure 2-6. Confirm Download
13. Click Yes to begin the download. The following message displays
when the download completes:
Figure 2-7. ROCLINK 800 Download Confirmation
14. Click OK. The User Program Administrator screen displays (see
Figure 2-8). Note that:
The Device User Program Environment frame reflects the use of
system memory.
The User Programs Installed in Device frame identifies the
installed program(s).
The Status field indicates the program is loaded and running.
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 10
Figure 2-8. User Program Administrator
15. Proceed to Section 3 to configure the programs.
2.3 MPU Loading Threshold
To maximize the performance of your ROC800 device, always verify the
performance of specific application combinations before using them in the
field to ensure the MPU load typically remains below 85% with peak
MPU loading levels below 95%.
To check the current MPU load at any time, select ROC > Information >
Other Information and review the value in the MPU loading field.
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 11
Figure 2-9. MPU Loading
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 12
[This page is intentionally left blank.]
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 13
Chapter 3 Configuration
After you have loaded the V-Cone program, you configure it using
ROCLINK 800 software. Most of the configuration for the V-Cone meter
is done through the standard orifice meter setup screen and the station
setup screen for the station to which the orifice meter belongs. For more
information, refer to ROCLINK 800 Configuration Software User Manual
(for ROC800-Series) (part D301250X012).
To do this, you use one program-specific screen (V-Cone Configuration)
and two standard ROCLINK 800 screens (Orifice Meter Setup and Station
Setup):
Use the V-Cone Configuration screen to enable, select the
McCrometer type along with the corresponding flow coefficient, and
assign the V-Cone calculation for a specific meter run.
Use the Station Setup screen to configure parameters common to
multiple meter runs.
Use the Orifice Meter Setup screen to configure parameters for a
single meter run for use with the V-Cone program.
Use the Orifice Values screen to view values calculated by the V-Cone
program.
Figure 3-1. ROCLINK 800 screen
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 14
3.1 V-Cone Configuration Screen
Use the V-Cone configuration screen to assign the V-Cone meter to an
existing orifice meter run and to enter the flow coefficient. You can also
view the actual volumetric flow rate per second, the thermal expansion
coefficient, the fluid velocity, and the percent pressure loss.
To access this screen:
1. From the Directory Tree, select User Program > Program #1,
V-Cone.
2. Select Display #61/71, V-Cone Configuration.
3. Double-click #1. The V-Cone Configuration screen displays:
Figure 3-2. V-Cone Configuration Screen
4. Review the values in the following fields:
Field
Description
Point Number
Indicates the iteration of the program you want to
define. You can assign each iteration of the
program (up to 12) to individual meter runs. Click
▼ to display additional iterations.
V-Cone Tag
This read-only field shows the meter tag for the
selected meter. The meter tag is defined in
Meter>Setup.
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 15
Field
Description
End Element
Type
Specifies the end element type of the selected
meter. Valid Selections are V-Cone and Wafer-
Cone.
Associated
Orifice Run
Sets the orifice meter used in V-Cone
calculations for the selected point number. Either
the Orifice Meter Run Configuration or Orifice
Meter Run Values point type can be selected and
any valid logical or parameter number.
Note: The selected orifice meter point is
automatically assigned a “User Defined
Device” meter type and the user program
will be in control of calculating all values
except compressibility and density.
Flow Coefficient
Sets a user-defined value for calculations. This
value is obtained from the V-Cone sizing and
calibration report.
Units
This read-only field displays the units of
measurement for this V-Cone point. Valid values
are US or Metric.
Note: The Units selection is made under
Meter>Setup>Station for the station to
which the associated orifice meter run
belongs.
Fluid Velocity
This read-only field displays the velocity of the
fluid through the V-Cone. Values are in
feet/second or meters/second.
Actual Volume
Flow Rate
This read-only field displays the volumetric flow
rate at the flowing temperature and pressure.
Values are in ft3/second or m3/second.
Percent
Pressure Loss
This read-only field displays the permanent
pressure loss at the V-Cone expressed as a
percentage of the differential pressure.
Thermal
Expansion
Factor
This read-only field displays the correction for
the expansion of the cone and pipe materials,
due to differences between operating
temperature and calibration temperature.
5. Click Apply to save any changes you have made to this screen.
6. Proceed to Section 3.2 to configure the Orifice/Station configuration.
V-Cone Metering Program User Manual (for ROC800-Series)
Revised June-2016 Configuration 16
3.2 Station Setup
The Station Setup screen is accessed via Meter > Setup > Station. This
screen allows for configuration of attributes that are common to multiple
meter runs. General items such as the base pressure, base temperature, unit
selection and gas quality data are configured here. On the general tab,
several station values are displayed which represent the summation of all
the meter runs in the station. For more information, refer to ROCLINK 800
Configuration Software User Manual (for ROC800-Series) (part
D301250X012).
Figure 3-3. Station Setup – Advanced Tab
Review the configuration on this screen, and click Apply to save any
changes you have made. Proceed to Section 3.3 to configure the Meter
Setup screen.
3.3 Orifice Meter Setup
The Orifice Meter Setup screen is accessed via Meter > Setup > Orifice
Meter. This screen allows for configuration of attributes of a single orifice
meter. The Meter Type selection on the Orifice Meter Setup screen is
automatically set to “User Defined Device” by the V-Cone user program
when the orifice meter point for the selected meter run is selected as the
associated meter run in the V-Cone program. This has the effect of
bypassing the standard AGA3 calculation and allows the V-Cone program
to write the results of the V-Cone or Wafer-Cone calculation to the orifice
meter point type.
The following parameters have different meanings for the V-Cone
metering user program.
Orifice Diameter Represents the diameter of the V-Cone or
Wafer-Cone Values are in inches or mm.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Remote Automation Solutions V-Cone Metering Program (For ROC800) Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI