Ingersoll-Rand SSR M11 Operation and Maintenance Manual

Type
Operation and Maintenance Manual

This manual is also suitable for

SSR M4 M5,5
M7,5 M11
OPERATION AND MAINTENANCE MANUAL
This manual contains
important safety information
and must be made available to
personnel who operate and
maintain this machine.
2161200M11 –>
2141800M7,5 –>
2121300M5,5 –>
2101200M4 –>SERIAL No :
SERIAL No :
SERIAL No :
SERIAL No :
C.C.N. : 89270334 GB
DATE : NOVEMBER 2002
04/02
Machine models represented in this manual may be used in various locations world–wide. Machines sold and
shipped into European Union Territories require that the machine display the EC Mark and conform to various
directives. In such cases, the design specification of this machine has been certified as complying with EC directives.
Any modification to any part is absolutely prohibited and would result in the CE Certification and marking being
rendered invalid. A declaration of that conformity follows:
EC DECLARATION OF CONFORMITY WITH EC DIRECTIVES
98/37/EC, 93/68/EEC, 89/336/EEC
WE,
INGERSOLLRAND COMPANY LIMITED
SWAN LANE
HINDLEY GREEN
WIGAN WN2 4EZ
UNITED KINGDOM
DECLARE THAT, UNDER OUR SOLE RESPONSIBILITY FOR MANUFACTURE AND SUPPLY,
THE PRODUCT(S)
M4 M5,5 M7,5 M11
TO WHICH THIS DECLARATION RELATES, IS (ARE) IN CONFORMITY WITH THE PROVISIONS
OF THE ABOVE DIRECTIVES USING THE FOLLOWING PRINCIPAL STANDARDS.
EN29001, EN292, EN602041, EN1012, EN50081, EN50082
ISSUED AT HINDLEY GREEN ON 01/01/2002 BY H.SEDDON, QUALITY ASSURANCE
MANAGER.
H. SEDDON
EC Pressure Equipment Directive and Related Regulations
We declare that this product has been assessed according to the Pressure Equipment Directive
(97/23/EC) and, in accordance with the terms of this Directive, has been excluded from the scope
of this Directive.
It may carry ”CE” marking in compliance with other applicable EC Directives.
CONTENTS & ABBREVIATIONS
1
M4 M5,5 M7,5 M11
CONTENTS
1 CONTENTS
2 FOREWORD
3 ISO SYMBOLS
8 SAFETY
10 GENERAL INFORMATION
15 INSTALLATION / HANDLING
18 OPERATING INSTRUCTIONS
19 AIRCARE WARRANTY
20 MAINTENANCE
25 FAULT FINDING
26 OPTIONS
ABBREVIATIONS & SYMBOLS
#### Contact IngersollRand for serial number
>#### Up to Serial No.
####> From Serial No.
* Not illustrated
Option
NR Not required
AR As required
SM Sitemaster/Sitepack
HA High ambient machine
WC Watercooled machine
AC Aircooled machine
ERS Energy recovery system
T.E.F.C. Totally enclosed fan cooled motor (IP54)
O.D.P. Open drip proof (motor)
ppm parts per million
BR Brazil
CN China
DE Germany
DK Denmark
ES Spain
FI Finland
FR France
GB Great Britain (English)
IT Italy
NL Holland
NO Norway
PT Portugal
SE Sweden
US United States
FOREWORD
2
M4 M5,5 M7,5 M11
The contents of this manual are considered to be proprietary and
confidential to IngersollRand and should not be reproduced without
the prior written permission of IngersollRand.
Nothing contained in this document is intended to extend any
promise, warranty or representation, expressed or implied, regarding
the IngersollRand products described herein. Any such warranties or
other terms and conditions of sale of products shall be in accordance
with the standard terms and conditions of sale for such products, which
are available upon request.
This manual contains instructions and technical data to cover all
routine operation and scheduled maintenance tasks by operation and
maintenance staff. Major overhauls are outside the scope of this
manual and should be referred to an authorised IngersollRand service
department.
The design specification of this machine has been certified as
complying with E.C. directives. Any modification to any part is
absolutely prohibited and would result in the CE certification and
marking being rendered invalid.
All components, accessories, pipes and connectors added to the
compressed air system should be:
. of good quality, procured from a reputable manufacturer and,
wherever possible, be of a type approved by IngersollRand.
. clearly rated for a pressure at least equal to the machine maximum
allowable working pressure.
. compatible with the compressor lubricant/coolant.
. accompanied with instructions for safe installation, operation and
maintenance.
Details of approved equipment are available from Ingersoll–Rand
Service departments.
The use of repair parts other than those included within the
IngersollRand approved parts list may create hazardous conditions
over which IngersollRand has no control. Therefore IngersollRand
cannot be held responsible for equipment in which nonapproved
repair parts are installed.
IngersollRand reserves the right to make changes and
improvements to products without notice and without incurring any
obligation to make such changes or add such improvements to
products sold previously.
The intended uses of this machine are outlined below and examples
of unapproved usage are also given, however IngersollRand cannot
anticipate every application or work situation that may arise.
IF IN DOUBT CONSULT SUPERVISION.
This machine has been designed and supplied for use only in the
following specified conditions and applications:
. Compression of normal ambient air containing no known or
detectable additional gases, vapours. or particles
. Operation within the ambient temperature range specified in the
GENERAL INFORMATION section of this manual.
The use of the machine in any of the situation types listed in
table 1:
a) Is not approved by IngersollRand,
b) May impair the safety of users and other persons, and
c) May prejudice any claims made against IngersollRand.
TABLE 1
Use of the machine to produce compressed air for:
a) direct human consumption
b) indirect human consumption, without suitable filtration and purity
checks.
Use of the machine outside the ambient temperature range
specified in the GENERAL INFORMATION SECTION of this manual.
Use of the machine where there is any actual or foreseeable risk of
hazardous levels of flammable gases or vapours.
Use of the machine fitted with non Ingersoll–Rand approved
components.
Use of the machine with safety or control components missing or
disabled.
The company accepts no responsibility for errors in translation of
this manual from the original English version.
SSR ULTRA COOLANT is a registered trademark of
Ingersoll–Rand Company USA.
COPYRIGHT 2002
INGERSOLLRAND COMPANY
ISO SYMBOLS 3
M4 M5,5 M7,5 M11
GRAPHIC FORM AND MEANING OF ISO SYMBOLS
Prohibition / Mandatory Information / Instructions Warning
WARNING: Electrical shock risk. WARNING Pressurised vessel. WARNING Hot surface.
WARNING Pressure control. WARNING Corrosion risk. WARNING Air/gas flow or Air discharge.
X,XBAR
WARNING Pressurised component or
system.
WARNING Hot and harmful exhaust gas.
WARNING Maintain correct tyre pressure.
(Refer to the GENERAL INFORMATION
section of this manual).
0_C
WARNING Flammable liquid.
WARNING Before connecting the tow bar
or commencing to tow consult the
operation and maintenance manual.
WARNING For operating temperature
below 0_C, consult the operation and
maintenance manual.
ISO SYMBOLS4
M4 M5,5 M7,5 M11
WARNING Do not undertake any
maintenance on this machine until the
electrical supply is disconnected and the air
pressure is totally relieved.
WARNING Consult the operation and
maintenance manual before commencing
any maintenance.
Do not breathe the compressed air from this
machine.
Do not remove the Operating and Maintenance
manual and manual holder from this machine.
Do not stack.
Do not operate the machine without the guard
being fitted.
Do not stand on any service valve or other
parts of the pressure system.
Do not operate with the doors or enclosure
open.
Do not use fork lift truck from this side.
XX
km/h
Do not exceed the trailer speed limit. No naked lights.
Do not open the service valve before the
airhose is attached.
Use fork lift truck from this side only. Emergency stop. Tie down point
ISO SYMBOLS 5
M4 M5,5 M7,5 M11
Lifting point. On (power). Off (power).
a
Read the Operation and Maintenance manual
before operation or maintenance of this
machine is undertaken.
When parking use prop stand, handrake and
wheel chocks.
Contains asbestos.
SET SEQUENCER STATUS LOAD
SEQUENCER (AUTOMATIC CONTROL) COMPRESSOR OFF LOAD (UNLOADED)
RESET COMPRESSOR STATUS MODULATE
MALFUNCTION POWER SOILED FILTER
POWER INLET ELECTRIC MOTOR HOURS
ISO SYMBOLS6
M4 M5,5 M7,5 M11
COOLANT SEPARATOR PRESSURE AIR DISCHARGE
PRESSURISED TANK ON / OFF CYCLE COOLANT FILTER
AIR FILTER ON / OFF PUSH BUTTON COOLANT PRESSURE
AIR PRESSURE STAR DELTA IEC 6177 AUTOMATIC RESTART
HEAT EXCHANGER MAINTENANCE MAINTENANCE PROHIBITED
COOLANT DRAIN CONDENSATE DRAIN PRESSURE CONTROL
MANUAL (SELECT) TEMPERATURE HIGH TEMPERATURE
ISO SYMBOLS 7
M4 M5,5 M7,5 M11
BELT TENSION FILTER MOTOR LUBRICATION
FRAGILE KEEP DRY THIS WAY UP
USE NO HOOKS NO SIDE CLAMPS ROTATION
POWER INLET (AC) WATER IN WATER OUT
SAFETY
8
M4 M5,5 M7,5 M11
WARNINGS
Warnings call attention to instructions which must be followed
precisely to avoid injury or death.
CAUTIONS
Cautions call attention to instructions which must be followed
precisely to avoid damaging the product, process or its surroundings.
NOTES
Notes are used for supplementary information.
General Information
Ensure that the operator reads and understands the decals and
consults the manuals before maintenance or operation.
Ensure that the Operation and Maintenance manual, and the
manual holder, are not removed permanently from the machine.
Ensure that maintenance personnel are adequately trained,
competent and have read the Maintenance Manuals.
Compressed air and electricity can be dangerous. Before
undertaking any work on the compressor, ensure that the electrical
supply has been isolated and the compressor has been relieved of all
pressure.
Make sure that all protective covers are in place and that the
canopy/doors are closed during operation.
Installation of this compressor must be in accordance with
recognised electrical codes and any local Health and Safety Codes.
The use of plastic bowls on line filters without metal guards can be
hazardous. Their safety can be affected by either synthetic lubricants,
or the additives used in mineral oils. Metal bowls should be used on a
pressurised system.
Compressed air can be dangerous if incorrectly handled. Before
doing any work on the unit, ensure that all pressure is vented from the
system and that the machine cannot be started accidentally.
Compressed air
Ensure that the machine is operating at the rated pressure and that
the rated pressure is known to all relevant personnel.
All air pressure equipment installed in or connected to the machine
must have safe working pressure ratings of at least the machine rated
pressure.
If more than one compressor is connected to one common
downstream plant, effective check valves and isolation valves must be
fitted and controlled by work procedures, so that one machine cannot
accidently be pressurised / over pressurised by another.
Compressed air must not be used for a direct feed to any form of
breathing apparatus or mask.
The discharged air contains a very small percentage of compressor
lubricating oil and care should be taken to ensure that downstream
equipment is compatible.
If the discharged air is to be ultimately released into a confined
space, adequate ventilation must be provided.
When using compressed air always use appropriate personal
protective equipment.
All pressure containing parts, especially flexible hoses and their
couplings, must be regularly inspected, be free from defects and be
replaced according to the Manual instructions.
Compressed air can be dangerous if incorrectly handled. Before
doing any work on the unit, ensure that all pressure is vented from the
system and that the machine cannot be started accidentally.
Avoid bodily contact with compressed air.
The safety valve located in the separator tank must be checked
periodically for correct operation.
Materials
The following substances are used in the manufacture of this
machine and may be hazardous to health if used incorrectly:
. preservative grease
. rust preventative
. compressor coolant
AVOID INGESTION, SKIN CONTACT AND INHALATION OF
FUMES
For further information, consult Material Data Sheets ACGP 011/96
(ULTRA COOLANT) and IRACA145 (food grade coolant).
Should compressor lubricant come into contact with the eyes, then
irrigate with water for at least 5 minutes.
Should compressor lubricant come into contact with the skin, then
wash off immediately.
Consult a physician if large amounts of compressor lubricant are
ingested.
Consult a physician if compressor lubricant is inhaled.
Never give fluids or induce vomiting if the patient is unconscious or
having convulsions.
Transport
When loading or transporting machines ensure that the specified
lifting and tie down points are used.
Electrical
Keep all parts of the body and any handheld tools or other
conductive objects, away from exposed live parts of the compressor
electrical system. Maintain dry footing, stand on insulating surfaces
and do not contact any other portion of the compressor when making
adjustments or repairs to exposed live parts of the compressor
electrical system.
Close and lock all access doors when the compressor is left
unattended.
Do not use extinguishers intended for Class A or Class B fires on
electrical fires. Use only extinguishers suitable for class BC or class
ABC fires.
Attempt repairs only in clean, dry, well lighted and ventilated areas.
Connect the compressor only to electrical systems that are
compatible with its electrical characteristics and that are within its rated
capacity.
SAFETY
9
M4 M5,5 M7,5 M11
Condensate disposal
Condensate cannot be discharged into fresh/surface water drains.
In some regions compressor condensate containing ULTRA
COOLANT can be fed directly into a drainage system that has
downstream sewerage treatment.
As waste water regulations vary by country and region it is the
responsibility of the user to establish the limitations and regulations in
their particular area. IngersollRand and its associated distributors are
happy to advise and assist in these matters.
Coolant disposal
Steps to be taken in the case of spillage: Soak up with a suitable
absorbent material, then sweep into a plastic bag for disposal.
Burn in an approved incinerator, or according to local area or
country regulations.
For further information, consult Material Data Sheets ACGP 011/96
(ULTRA COOLANT) and IRACA145 (food grade coolant).
GENERAL INFORMATION
10
M4 M5,5 M7,5 M11
Revision 00
11/97
KEY
1 Filter, air
2 Regulator
3 Valve, solenoid
4 Airend assembly
5 Motor
6 Tank, separator
Coarse
7 Tank, separator
Fine
8 Valve, minimum pressure
9 Aftercooler
10 Gauge, pressure
11 Switch
Discharge pressure
12 Switch, temperature
13 Filter, coolant
14 Thermostat
15 Cooler
16 Relay, overload
Motor
17 Valve, safety
18 Valve, drain
19 Screen, scavenge
KEY
Condensate
Air/Coolant
Air
Water
Regulation
Coolant
GENERAL OPERATION
The compressor is an electric motor driven, single stage screw
compressor, complete with accessories piped, wired and baseplate or
receiver mounted. It is a totally self contained air compressor package.
The standard compressor is designed to operate in an ambient
range of 1,7_C to 46_C. The standard maximum temperature of 46_C
is applicable up to an elevation of 1000m (3280ft) above sea level.
Above this altitude significant reductions in ambient temperature are
required if a standard motor is to be used.
Compression in the screw type air compressor is created by the
meshing of two (male & female) helical rotors.
The air/coolant mixture discharges from the compressor into the
separation system. This system removes all but a few PPM of the
coolant from the discharge air. The coolant is returned to the cooling
system and the air passes through the aftercooler and out of the
compressor.
Air is pulled through the coolers by the cooling fans and discharged
on the underside of the machine.
GENERAL INFORMATION
11
M4 M5,5 M7,5 M11
The power transmission from the drive motor to the airend male
rotor is by pulley and Vbelts. The constant auto tensioning system,
using motor mass and torque, ensures that the belts are always under
the correct tension, eliminating the need for adjustment and maximising
the life of the belts.
By cooling the discharge air, much of the water vapour naturally
contained in the air is condensed and may be drained from the
downstream piping and equipment.
The coolant system consists of a sump, cooler, thermostatic valve
and a filter. When the unit is operating, the coolant is pressurised and
forced to the compressor bearings.
The compressor load control system is automatic OnOff line. The
compressor will operate to maintain a set discharge line pressure and
is provided with an autorestart system for use in plants where the air
demand varies widely.
Safety of operation is provided for as the compressor will shut down
if excessive temperatures or electrical overload conditions should
occur.
M4 M5,5 M7,5 M11
COMPRESSOR
Maximum operating
pressure
7,5
bar
8,5
bar
10,0
bar
13,0
bar
7,5
bar
8,5
bar
10,0
bar
13,0
bar
7,5
bar
8,5
bar
10,0
bar
13,0
bar
7,5
bar
8,5
bar
10,0
bar
13,0
bar
Normal operating pressure 7,0
bar
8,0
bar
9,5
bar
12,5
bar
7,0
bar
8,0
bar
9,5
bar
12,5
bar
7,0
bar
8,0
bar
9,5
bar
12,5
bar
7,0
bar
8,0
bar
9,5
bar
12,5
bar
Maximum Pressure ratio 8,5
:1
9,5
:1
11,0
:1
14,0
:1
8,5
:1
9,5
:1
11,0
:1
14,0
:1
8,5
:1
9,5
:1
11,0
:1
14,0
:1
8,5
:1
9,5
:1
11,0
:1
14,0
:1
Maximum airend discharge
temperature
109 _C 109 _C 109 _C 109 _C
Ambient operating
temperature
+2_C +46_C +2_C +46_C +2_C +46_C +2_C +46_C
MOTOR
Nominal power 4,0 kW 5,5 kW 7,5 kW 11,0 kW
Speed 2880 RPM 2880 RPM 2880 RPM 2880 RPM
IP rating 55 IP 55 IP 55 IP 55 IP
Frame B3 B3 B3 B3
Insulation class F F F F
COOLING SYSTEM
Air cooled
Cooling air flow 660 m
3
/H 1320 m
3
/H 1320 m
3
/H 1980 m
3
/H
Maximum P in air ducts 3 Pa/mm WG 3 Pa/mm WG 3 Pa/mm WG 3 Pa/mm WG
Compressed air outlet T 8_C 8_C 8_C 8_C
GENERAL DATA
Residual coolant content 23 mg/m
3
23 mg/m
3
23 mg/m
3
23 mg/m
3
Separator vessel capacity 8 l 8 l 8 l 8 l
Coolant capacity 7 l 7 l 7 l 7 l
Sound pressure level to
CAGIPNEUPROP
73 dB (A) 73 dB (A) 73 dB (A) 73 dB (A)
Weight 212kg
398kg (500l)
303kg (272l)
212kg
398kg (500l)
303kg (272l)
212kg
398kg (500l)
303kg (272l)
212kg
398kg (500l)
303kg (272l)
Discharge connection G
3
/
4
G
3
/
4
G
3
/
4
G
3
/
4
Dimensions (L x W x H) 935mm x 732mm x 755mm
2080mm x 732mm x
1436mm (500l)
1406mm x 732mm x
1415mm (272l)
935mm x 732mm x 755mm
2080mm x 732mm x
1436mm (500l)
1406mm x 732mm x
1415mm (272l)
935mm x 732mm x 755mm
2080mm x 732mm x
1436mm (500l)
1406mm x 732mm x
1415mm (272l)
935mm x 732mm x 755mm
2080mm x 732mm x
1436mm (500l)
1406mm x 732mm x
1415mm (272l)
GENERAL INFORMATION
12
M4 M5,5 M7,5 M11
M4 M5,5 M7,5 M11
ELECTRICAL DATA
Standard voltage 3 ~ 400V 3 ~ 400V 3 ~ 400V 3 ~ 400V
Drive motor
Power 4,0 kW 5,5 kW 7,5 kW 11,0 kW
Full load current
(maximum)
8,1 A 11,3 A 15,3 A 23,0 A
Starting current (approx.) 28,3 A 39,5 A 53,5 A 80,5 A
Starting time 6 S 6 S 6 S 6 S
Starts per hour 20 IP23/54 20 IP23/54 20 IP23/54 10 IP23/54
Fan motor
Power 80 W 160 W 160 W 240 kW
Control voltage
Control 110 VAC 110 VAC 110 VAC 110 VAC
Mains supply cable (cross
section)
1
PVC/PVC
4 mm
2
Cu 4 mm
2
Cu 4 mm
2
Cu 6 mm
2
Cu
Fuse rating
2
16 A 16 A 20 A 32 A
1
Local Regulations apply if stricter than above.
The voltage drop must not exceed 5% of the nominal voltage.
It may be necessary to use cables with a larger section than those
stated to comply with this requirement.
2
gG
NOTE
All data applies to standard product only.
GENERAL INFORMATION
13
M4 M5,5 M7,5 M11
GENERAL INFORMATION
14
M4 M5,5 M7,5 M11
KEY
CABLE
PE Supply earth
L1L3 Mains terminals
B Earth point, Subbase
KM1 Main contactor
KM2 Delta contactor
KM3 Star contactor
MM Main motor
F1 Fuse, fan motor
FM Fan motor
CB15Circuit breaker
T1 Transformer, control supply
T2 Transformer, dryer supply
MAXT Temperature switch
MOL Motor overload
ES Switch, emergency stop
1SV Load solenoid
P Pressure switch
TM Star Delta Timer
TM1 Runon Timer
HR Hourmeter
R1R2Relay, control
Terminal, control
Option
S1 Pushbutton, start
S2 Pushbutton, dryer on
S3 Pushbutton, dryer off
DR1 Supply to dryer (supply has neutral) (Option)
DR2 Supply to dryer (supply has no neutral) (Option)
INSTALLATION / HANDLING
15
M4 M5,5 M7,5 M11
Revision 00
10/97
892100741
NOTE
All dimensions are in millimetres unless otherwise stated.
LOCATION IN PLANT
The compressor can be installed on any level floor capable of
supporting it. A dry, well ventilated area where the atmosphere is as
clean as possible is recommended. A minimum of 0,5m should be left
around all sides of the machine for adequate service access and
ventilation.
Ensure that the correct fork lift truck slots or marked lifting / tie down
points are used whenever the machine is lifted or transported.
CAUTION
Screw type compressors [1] should not be installed in air systems
with reciprocating compressors without means of isolation such as a
common receiver tank. It is recommended that both types of
compressor be piped to a common receiver using individual air lines.
INSTALLATION / HANDLING
16
M4 M5,5 M7,5 M11
Revision 00
10/97
892100742
CAUTION
The use of plastic bowls on line filters and other plastic air line
components without metal guards can be hazardous. Their safety can
be affected by either synthetic coolants or the additives used in mineral
oils. From a safety standpoint, metal bowls should be used on any
pressurised system.
INSTALLATION / HANDLING
17
M4 M5,5 M7,5 M11
Revision 00
02/98
892100743
DISCHARGE PIPING
Discharge piping should be at least as large as the discharge
connection of the compressor. All piping and fittings should be suitably
rated for the discharge pressure.
It is essential when installing a new compressor [1], to review the
total air system. This is to ensure a safe and effective total system. One
item which should be considered is liquid carryover. Installation of air
dryers [3] is always good practice since properly selected and installed
they can reduce any liquid carryover to zero.
It is good practice to locate an isolation valve close to the
compressor and to install line filters [4].
NOTE
The machine is shipped with the automatic belt tension system
locked. remove the bolt which clamps the pivoted table to the main
chassis before running the compressor.
ELECTRICAL DATA
An independent electrical isolator should be installed adjacent to the
compressor.
CAUTION: Do not remove the motor table transit bolt until the electrical
connection and correct rotation have been completed.
Feeder cables should be sized by the customer/electrical
contractor to ensure that the circuit is balanced and not overloaded by
other electrical equipment. The length of wiring from a suitable
electrical feed point is critical as voltage drops may impair the
performance of the compressor. Cable sizes may vary considerably
so the mains terminals will accept up to 16mm
2
cable.
Feeder cable connections to studs L1L2L3 on isolator should be
tight and clean.
The applied voltage must be compatible with the motor and
compressor data plate ratings.
The control circuit transformer has different voltage tappings.
Ensure that these are set for the specific applied voltage prior to
starting.
OPERATING INSTRUCTIONS
18
M4 M5,5 M7,5 M11
PRIOR TO STARTING
1. Check coolant level. Add if necessary.
The reservoir is designed to prevent overfill. With warm unit stopped
in the normal way, the sight tube level should be within 15mm of the top
of the green strip. The level should not drop beyond the bottom of the
sight tube when running with a steady load.
2. Make sure main discharge valve is open.
3. Turn on electrical isolator. The Power On (5) L.E.D. will light,
indicating that line and control voltages are available.
WARNING
Make sure that all protective covers are in place.
STARTING
Press Start (4). The compressor will start and then load
automatically.
NORMAL/EMERGENCY STOPPING
1. Press Emergency stop/Stop button (3) and the compressor will
stop.
2. Turn off electrical isolator.
CAUTION
After shutdown never allow unit to stand idle with pressure in
receiver/separator system.
KEY
1: PRESSURE GAUGE
Indicates the pressure immediately after the aftercooler. DO NOT
operate the compressor at discharge pressures over the rated
pressure.
2: HOURMETER
Records the total running time of the compressor.
3: EMERGENCY STOP/STOP
When depressed will stop the compressor immediately. The Power
on L.E.D. will remain illuminated. The emergency stop button must be
released before the compressor can be restarted.
4: START
When depressed will cause the unit to start and run in a loaded
condition if there is a demand for air. If there is no demand, the machine
will run unloaded.
5: POWER ON (Green)
Indicates the presence of control voltage at the controller.
6: AUTO RESTART (Amber)
Will illuminate when the machine has shut-down due to low air
demand. The machine will restart and load automatically as soon as the
demand for air returns.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36