Arlec 62999 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Arlec 62999 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
COMPACT
Bell & Chime Transformer
Please read these instructions carefully
before installing the Arlec Bell & Chime
Transformer.
Important Notes
1. This transformer is designed for operation
on 8V or 12V output. Do not connect loads
simultaneously to both outputs.
2. The marked output of 1A is not the continuous
current rating. This rating is based on short
duty cycles of operation, as is normal for a bell
chime. The transformer is capable of delivering
a continuous current of 200mA, plus the short
duration peaks of 1A. More than one bell or
chime may be connected provided that the
ratings are not exceeded. Failure to observe the
above may result in permanent damage to the
transformer.
SPECIFICATION
Input: 240V 50Hz 3VA
Output Voltage: 12 or 8 Vac
Output Current: 200mA max continuous,
plus 1A peaks.
Max duty cycle 1 minute on
5 minutes off.
All wiring should be carried out by a licensed
electrical contractor.
Site the transformer in an accessible position as
close as practicable to the bell chime, the push
button door switch and a mains supply.
Four 25mm No.4 self tapping screws are supplied
with the transformer to fix it into position.
1. Remove the cover from the 240V mains
connections by depressing the locking tabs with
a small screwdriver.
2. A knockout is provided on the side of the mains
cover to enable wires to be connected to the
transformer.
3. Switch off the power at the meter box. Connect
the Neutral wire of the mains electricity supply
to the transformer terminals marked N - 240V
50Hz. Connect the active wire through a circuit
breaker or switch (with air gap separation) to the
transformer terminal marked A - 240V 50Hz.
4. According to the voltage of the bell or chime
to be operated, connect the circuit wires to
the appropriate terminals as indicated on the
diagram.
5. Replace the mains connection cover by sliding it
into place over the locking tabs.
6. Switch on the power and check the operation of
your bell/chime.
CPIN368/2
A
N
Block Diagram
Transformer
AC Main
Supply
Push Button
Bell or
Chime
Circuit Breaker
CPIN00368I2.indd 1 5/09/11 4:48 PM
Arlec Warranty*
Arlec guarantees this product against defects of materials
and workmanship for a period of 12 months from the date
of purchase provided the product is used for its proper
purpose, in accordance with Arlec’s recommendations
and within such voltage and current limits as are
specified by Arlec in relation to the product. Arlec will
at its own option and cost make good, or replace this
product with the same or similar product and return it to
you, or provide a credit for any product manufactured or
supplied by it, which proves to be defective within the
limits set out above provided that no repairs, alterations
or modifications to the product have been undertaken or
attempted by anyone, other than Arlec or its authorized
agents. Should you wish to make a claim under this
guarantee, the product and proof of purchase must be
returned pre-paid by you to the place of purchase.
This guarantee is in addition to and does not take away
from any other rights and remedies you may have under
any relevant law.
Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled
to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure.
*Excludes Batteries
Please retain your proof of purchase for all warranty
claims.
For all Sales & Warranty enquiries
Arlec Australia Pty Ltd. (A.C.N. 009 322 105)
Building 3, 31-41 Joseph Street,
Blackburn North, Victoria, 3130
P.O. Box 1065, Blackburn North LPO
Blackburn North, 3130
Phone (03) 9982 5111
Fax 1300 360 650
CPIN368/2
240 V 50Hz INPUT
OUTPUT 1A MAX.
N A
APPROVAL No. V94055/E141-26
Knock out for side entry mains wiring
Four screw
holes for
mounting
F
12V AC
8V AC
8V AC
Bell & Chime
Transformer
12V AC
CPIN00368I2.indd 2 5/09/11 4:48 PM
/