Peerless Vellum Single Pendant Installation guide

Type
Installation guide
Toreducetheriskofdeath,personalinjuryorpropertydamagefromfire,electricshock,fallingparts,cuts/abrasions,and
otherhazardspleasereadallwarningsandinstructionsincludedwithandonthefixtureboxandallfixturelabels.
Beforeinstalling,servicing,orperformingroutinemaintenanceuponthisequipment,followthesegeneralprecautions.
Installationandserviceofluminairesshouldbeperformedbyaqualifiedlicensedelectrician.
Maintenanceoftheluminairesshouldbeperformedbyperson(s)familiarwiththeluminaires’constructionandoperation
andanyhazardsinvolved.Regularfixturemaintenanceprogramsarerecommended.
Donotuseoutdoors.
Donotmountneargasorelectricheaters.
Equipmentshouldbemountedinlocationsandatheightswhereitwillnotbesubjectedtotamperingbyunauthorized
personnel.
Theuseofaccessoryequipmentnotrecommendedbythemanufacturermaycauseanunsafecondition.
Donotusethisequipmentforotherthanitsintendeduse.
Itwilloccasionallybenecessarytocleantheoutsideoftherefractor/lens.Frequencyofcleaningwilldependonambientdirt
levelandminimumlightoutputwhichisacceptabletouser.Refractor/lensshouldbewashedinasolutionofwarmwater
andanymild,nonabrasivehouseholddetergent,rinsedwithcleanwaterandwipeddry.Shouldopticalassemblybecome
dirtyontheinside,wiperefractor/lensandcleaninabovemanner,replacingdamagedgaskets asnecessary.
DONOTINSTALLDAMAGEDPRODUCT!Thisluminairehasbeenproperlypackedsothatnopartsshouldhavebeen
damagedduringtransit.Inspecttoconfirm.Anypartdamagedorbrokenduringorafterassemblyshouldbereplaced.
Recycle:ForinformationonhowtorecycleLEDelectronicproducts,pleasevisitwww.epa.gov.
Theseinstructionsdonotpurporttocoveralldetailsorvariationsinequipmentnortoprovideeverypossiblecontingencyto
meetinconnectionwithinstallation,operation,ormaintenance.Shouldfurtherinformationbedesired,orshouldparticular
problems arisewhicharenotcoveredsufficientlyforthepurchaser’sorowner’spurposes,thismattershouldbereferredto
AcuityBrandsLighting,Inc.
IMPORTANTSAFETYINSTRUCTIONS
VMMSPandVMMQP
IMPORTANT SAFEGUARDS
Whenusingelectricalequipment,basicsafetyprecautionsshouldalwaysbefollowedincludingthefollowing:
Disconnectorturnoffpowerbeforeinstallationor
servicing.
Verifythatsupplyvoltageiscorrectbycomparingitwith
theequipmentlabelinformation.
Makeallelectricalandgroundedconnectionsin
accordancewiththeNationalElectricalCode(NEC)andany
applicablelocalcoderequirements.
AllwiringconnectionsshouldbecappedwithULapproved
recognizedwireconnectors.
WARNING
RISKOFELECTRICSHOCK
Allowlamp/fixturetocoolbeforehandling.Donottouch
hotlens,lamp,guard,orenclosure.
Donotexceedmaximumwattagemarkedonluminaire
label.
Followalllampmanufacturer’swarnings,
recommendationsandrestrictionsonlampoperation
includingbutnotlimitedto: ballasttype,burning
position,replacement,andrecycling.
WARNING
RISKOFBURN
Wearglovesandsafetyglassesatalltimes whenremoving
equipmentfromcarton,installing,servicingorperforming
maintenance.
Avoiddirecteyeexposuretothelightsourcewhileitison.
CAUTION
RISKOFINJURY
Keepcombustibleandothermaterialsthatcanburnaway
fromlamp/lens.
Donotoperateincloseproximityto persons,
combustiblematerialsorsubstancesaffectedbyheator
drying.
CAUTION
RISKOFFIRE
READANDFOLLOWALLSAFETYINSTRUCTIONS!
© 2023 Acuity Brands Lighting, Inc. All Rights Reserved.. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx 1
ModulusluminairesshouldonlyreceivelowvoltageDCpowerprovidedfromanadequately
ratedModulusheadunit.DONOTCONNECTLINEVOLTAGETOMODULUSLUMINAIRES.
Neverconnectcomponentsunderload.
Donotmountorsupportthesefixturesinamannerthatcancuttheouterjacketordamage
wireinsulation.
Unlessindividualproductspecificationsdeemotherwise:NeverconnectanLEDproduct
directlytoadimmerpacks,occupancysensors,timingdevices,orotherrelatedcontrol
devices.LEDfixturesmustbepowereddirectlyoffaswitchedcircuit.
Unlessindividualproductspecificationsdeemotherwise:Donotrestrictfixtureventilation.
Allowforsomevolumeofairspacearoundfixture.AvoidcoveringLEDfixtureswithinsulation,
foam,orothermaterialthatwillpreventconvectionorconductioncooling.
Unlessindividualproductspecificationsdeemotherwise:Donotexceedfixturesmaximum
ambienttemperature.
Onlyusefixtureinitsintendedlocation.
LEDproductsarePolaritySensitive.EnsureproperPolaritybeforeinstallation.
ElectrostaticDischarge(ESD):ESDcandamageLEDfixtures.Personalgroundingequipment
mustbewornduringallinstallationorservicingoftheunit.
DonottouchindividualelectricalcomponentsasthiscancauseESD,shortenlamplife,oralter
performance.
Somecomponentsinsidethefixturemaynotbeserviceable.Intheunlikelyeventyourunit
mayrequireservice,stopusingtheunitimmediatelyandcontactanABLrepresentativefor
assistance.
Alwaysreadthefixturescompleteinstallationinstructionspriortoinstallationforany
additionalfixturespecificwarnings.
CAUTION
RISKOFPRODUCTDAMAGE
PleaseseeproductspecificinstallationinstructionsforadditionalwarningsoranyapplicableFCCorotherregulatory
statements.
Failuretofollowanyoftheseinstructionscouldvoidproductwarranties.ForacompletelistingofproductTermsand
Conditions,pleasevisitwww.acuitybrands.com.
AcuityBrandsLighting,Inc.assumesnoresponsibilityforclaimsarisingoutofimproperorcareless
installationorhandlingofitsproducts.
ABLLEDGeneralWarnings,FormNo.503.203
©2023AcuityBrandsLighting,Inc.Allrightsreserved.
SAVETHESEINSTRUCTIONSANDDELIVERTOOWNERAFTER
INSTALLATION
© 2023 Acuity Brands Lighting, Inc. All Rights Reserved.. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
IMPORTANTSAFETYINSTRUCTIONS
VMMSPandVMMQP
2
VellumSingle&QuadPendant
INSTALLATIONINSTRUCTIONS
These installationinstructions are used for installing the following luminairesandkits:
05/2023ECO#155386
A.IdentificationofVMMSP/VMMQPLuminaire
IMPORTANT: Wear cotton glovesAND lift and handle the luminairefrom the ends to avoid damaging orsoiling the lens surface. Should thelens
surface become smudged orotherwise blemished, clean usingonly a soft, microfiber cotton cloth
PIN006500REV.B
© 2023 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this
document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies.
Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
3
Mounting KitDriver KitLuminaire
VMMQPFKVMMQPDKVMMQP
VMMSPFKVMMSPDKVMMSP
WARNING: Please read the “important safety instructions” prior to installation of this product. Mounting
frame must be installed before drywall installed. The mounting instructions can be found inside the
mounting kits or downloaded from PeerlessLighting.com.
A) Identification of VMMSP / VMMQP Luminaire…………………….……………………………………………………………..Page 3
B) Vellum quad (VMMQP) Installation ……………………………………………………………………………………………….Page 3-4
C) Control and system networking options. …...………...…….………..….………………………………………………..…..….Page 5
D) Vellum single (VMMSP) Installation ………………………………...…………………………………………………….………Page 5-6
E) Luminaire maintenance / cleaning.. ………………………………...………………………………………………….…………Page 6
B.VellumQuad(VMMQP)TbarInstallation
Cut ceiling opening 8.875 inch
diameter and position driver
mounting frame through
opening in ceiling
Assemble the channel bars to each
side of the mounting frame with the
included hardware. Leave the
hardware loose to adjust the position
of the frame in the ceiling. Adjust
channel bars to the correct spacing
between T-bar.
Secure channel bars to T-bar by means
of fastener (wire ties, screws, etc.) Re-
tighten both vertical adjustment nuts.
Re-tighten both
channel bar
clamping screws.
05/2023ECO#0155386
PIN006500REV.B
© 2023 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this
document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies.
Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
4
Slide mounting plate through the ceiling
and rest on mounting frame.
Locate aircraft cable kit.. Insert cable
gripper on the die cast end and
adjustable cable gripper on opposite end.
Install cable gripper onto luminaire on (4)
hangers.
Slide canopy, lock plate through aircraft
cable. Insert low voltage DC cable
coming from luminaire into ceiling
passing through canopy and lock plate.
Rotate mounting plate to make sure,
luminaire is aligned to desired position.
Secure luminaire position by fastening
lock plate against ceiling using (2X) #8
screws provided.
Secure canopy to the lock plate with
magnets provided on the lock plate.
Remove cover from low voltage box.
Connect run of wires from luminaire to
wires inside low voltage box making sure
colors match using terminal blocks
provided Tuck wires into low voltage box.
Secure cover using spring clip.
Insert conduit fitting to j-box shown
above. Make necessary electrical
connections on driver enclosure side.
Wire to requirements following local and
national electrical codes.
Luminaire is fully installed. Use
compressed air over entire lens to clean
up loose debris.
NonaccessibleCeilingInstallation(e.g. plaster,drywall,etc)
Mount to ceiling structure with flanges on
channel bars resting against the bottom
faces of the joists. Drive included nail into
joist to secure. Move vertical adjustment to
lowest point.
C.Controlandsystemnetworkingoptions.
05/2023ECO#0155386
PIN006500REV.B
© 2023 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this
document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies.
Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
5
Luminaire specified with sensor functionality
will ship with sensor, Cat5 cable and splitter.
Connect Cat5 cable to sensor and other end
to the nLight module power pack passing
through canopy and ceiling.
Connect Cat5 cable to the embedded nLight
module as shown above. This completes
daylight dimming and/or dual technology
occupancy detection.
D.Vellumsingle(VMMSP)Installation
IMPORTANT: Wear cotton glovesAND lift and handle the luminairefrom the ends to avoid damaging orsoiling the lens surface. Should thelens
surface become smudged orotherwise blemished, clean usingonly a soft, microfiber cotton cloth
Cut ceiling opening 5.125 inch diameter
and position driver mounting frame
through opening in ceiling.
Assemble the channel bars to each
side of the mounting frame with the
included hardware. Leave the
hardware loose to adjust the position
of the frame in the ceiling. Adjust
channel bars to the correct spacing
between T-bar.
Secure channel bars to T-bar by means
of fastener (wire ties, screws, etc.) Re-
tighten both vertical adjustment nuts.
Re-tighten both
channel bar
clamping screws.
Insert wires (red and black) coming out
of luminaire into stem Secure stem to
coupler on luminaire. Use tool to tighten
if needed.
Insert canopy and rest on luminaire.
Fasten 1/8 IP nut provided. Insert
hanger bracket and secure with other
1/8 IP nut provided. Make sure flange of
hanger is parallel with luminaire housing
side.
Insert luminaire into ceiling opening.
Avoid touching lens. Adjust luminaire to
desired position.
05/2023ECO#0155386
PIN006500REV.B
© 2023 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this
document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies.
Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
6
Secure luminaire position by fastening
lock plate against ceiling using (2X) #8
screws provided.
Secure canopy to the lock plate with
magnets provided on the lock plate.
Position in desired location.
Remove cover from low voltage box.
Bring wires from luminaire to inside of
the low voltage box and make sure
colors match using terminal blocks
provided for connection. Tuck wires into
low voltage box. Secure cover using
spring clip.
Dust and loose contaminants must be cleaned using compressed air. Hold the can 8” to 10“ away from lens and use short bursts.
DO NOT use cleaning products on optic lens.
Luminaire is fully installed. Use
compressed air over entire lens to clean
up loose debris.
NonaccessibleCeilingInstallation(e.g. plaster,drywall,etc)
Mount to ceiling structure with flanges on
channel bars resting against the bottom faces
of the joists. Drive included nail into joist to
secure. Move vertical adjustment to lowest
point.
Secure channel bars to Hatch Channel by
means of a fastener (wire ties, screws, etc).
E.Luminairemaintenance/cleaning
Insert conduit fitting to j-box. Make
necessary electrical connections on
driver enclosure side. Wire to
requirements following local and national
electrical codes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Peerless Vellum Single Pendant Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI