aoyue 9070 User manual

Type
User manual

Aoyue 9070 is an advanced high power ultrasonic cleaning system which incorporates the latest technologies to allow efficient and effective cleaning in the shortest amount of time.

Its large square stainless steel tank is specially suitable for cleaning oversized items such as PCBs, metal plates, boards and other objects with large surface area.

It has several advanced features such as temperature control, timer adjustment, sweep frequency, auto-load following, and power control.

Temperature control enables the system to quickly heat up to 50 degrees to the optimum cleaning temperature before engaging the ultrasonic cleaning process.

Aoyue 9070 is an advanced high power ultrasonic cleaning system which incorporates the latest technologies to allow efficient and effective cleaning in the shortest amount of time.

Its large square stainless steel tank is specially suitable for cleaning oversized items such as PCBs, metal plates, boards and other objects with large surface area.

It has several advanced features such as temperature control, timer adjustment, sweep frequency, auto-load following, and power control.

Temperature control enables the system to quickly heat up to 50 degrees to the optimum cleaning temperature before engaging the ultrasonic cleaning process.

CARE and MAINTENANCE
Clean the tank:
The stainless steel tank, rubber tubing and valves may be damaged by corro-
sive cleaning liquids. Always clean the tank with plain water after usage. Do
not allow cleaning liquids to stagnate in the rubber tubing and tank.
Replace water seal and rubber tubing:
The rubber tubing inside the tank should be checked for leaks or damages..
The water seal rubber at the drain filter and the rubber tubing inside the ma-
chine should be replaced every 3 years or when damage to the tube or seal is
suspected.
Allow system to rest:
Do not continually use the system at high power mode for prolonged periods.
Allow system to take 10 to 15 minutes breaks between high intensity cleaning
procedure. If system is working at high power mode for more than an hour.
Allow 15 minutes of rest for each hour.
The system may detect an overheat and cut off power to the ultrasonic sys-
tem. If an over heat is detected, cut off power to the system and let system
cool to room temperature before reactivating system for use.
Heating Elements:
Heating elements have a limited working cycle. Replacement of heating ele-
ments are needed if heating efficiency has deteriorated.
Manufacturer:
AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY
Jishui Industrial Zone, Nantou, Zhongshan City,
Guangdong Province, P.R.China
http://www.aoyue.com
INSTRUCTION MANUAL
INSTRUCTION MANUALINSTRUCTION MANUAL
INSTRUCTION MANUAL
Thank you for purchasing the Aoyue 9070 Ultrasonic Cleaner.
It is important to read the manual before using the equipment.
Please keep manual in accessible place for future reference.
9070
9070
ULTRASONIC CLEANER
AOYUE
®
2
22
2
TABLE OF CONTENTS
Product Description ……………………………………………… 3
Specifications …………………………………………………… 4
Functions and Features …………………………………… 4
Safety Precautions …………………………………………… 5—6
Control Panel Guide ………………………………………… 7
Operating Guidelines ………………………………………… 8—15
Care and Maintenance …………………………………… ……… 16
This manual is designed to familiarize and instruct the op-
erator with the proper usage and maintenance of the
equipment. The “Care and Safety Precautions” section
explains the hazards of using any type of soldering or re-
working device. Please read carefully and observe the
guidelines in order to maximize usage and minimize the
risk of injury or accidents .
15
1515
15
OPERATING GUIDELINES
Press the switch button to program segment “C”.
We set the power level of segment “C” to 000 (no ultrasonic
action) by pressing the down button of the multifunction
adjustment button until the power display shows 000. We set the
duration of segment “C” to 00:30 by pressing the timer
adjustment buttons.
Press the switch button to proceed to programming segment “d”.
We set the power level of segment “d” to 100 by pressing the
multifunction adjustment buttons. We set the duration of
segment “d” to 01:00 by pressing the timer adjustment buttons.
Press the switch button again to program segment “E”.
Set the power level of segment “E” to 60 and the duration of
segment “E” to 01:00.
Press the switch button again to program segment “F”.
Set the power level of segment “F” to 000 and the duration of
segment “F” to 00:30.
Press the switch button again to switch to save profile view. The
display should show the word “SAVE”. Press the start button to
save the newly programmed cleaning profile. The display will
switch to showing segment “A” if save is successful.
To start the cleaning process repeatedly press the switch button
until we revert back to the temperature display view. Press the
start button to start cleaning function.
The system will start to heat up the cleaning liquid to 50 degrees
and then commence our programmed cleaning profile.
IMPORTANT: The system has a built in overheat protection feature
that will activate if over heat is detected. The display will show the
words “OVER HEAT” and all functions will be disabled. IF this
happens turn off system , allow system to cool to room temperature
before re-activating system for use.
14
1414
14
OPERATING GUIDELINES
Default profile of Mode 8:
Segment A b C d E F
Power Level 060 100 060 100 060 100
Duration 00:30 00:30 00:30 00:30 00:30 00:30
3. Sample profile creation: For example we want a cleaning profile
that would clean in high intensity for 1 minute, then at low intensity for
another minute and then pause for thirty seconds. The process should
repeat for a duration of 15 minutes at a cleaning liquid temperature of
50 degrees. The cleaning profile should look like this.
Sample:
Segment A b C d E F
Power Level 100 060 000 100 060 000
Duration 01:00 01:00 00:30 01:00 01:00 00:30
Place items to be cleaned into the tank with the cleaning liquid.
Repeatedly press the mode selection button to reach the desired
working mode 6,7 or 8 .
We set the temperature to 50 by pressing the multifunction
adjustment buttons. Set the overall time to 15:00 by pressing the
timer adjustment buttons.
Press the switch button to access segment “A power level
adjustment.
We set the power level of segment “A” to 100(maximum) by
pressing the multifunction adjustment buttons. We set the duration
of segment “A” by pressing the timer adjustment buttons until
timer displays 01:00.
Next press the switch button to proceed to programming segment
“b”.
We set the power level of segment “b” to 60 (minimum) by
pressing the multifunction adjustment buttons. We set the duration
of segment “b” to 01:00 by pressing the timer adjustment buttons.
3
33
3
The Aoyue 9070 is an advanced high power ultrasonic cleaning
system which incorporates the latest technologies to allow efficient and
effective cleaning in the shortest amount of time.
The square stainless steel tanks is specially suitable for cleaning
oversized items such as PCBs, Metal plates, boards and other objects
with large surface area.
It has several advanced features such as temperature control, timer
adjustment, sweep frequency, auto-load following, and power control.
Temperature control enables the system to quickly heat up to
optimum cleaning temperature before engaging the ultrasonic cleaning
process.
Timer adjustment allows accurate control of the cleaning duration
allowing repetitive batch processing and results.
Sweep frequency feature, eliminates damages to sensitive
components by continuously varying the operating frequency.
Auto-load following feature, allows the system to automatically
adjust the cleaning power depending on load conditions.
Power control feature, adjust cleaning power from 60 to 100
percent to cater to various cleaning requirements.
There are three available automated function that allow the
programming of a 5 stage cleaning profile for automated and consistent
cleaning. The programmable automated function allows custom cleaning
processes such as pulsed cleaning, variable power cleaning, or any other
combination of cleaning power, duration, and repetition.
Finally, the unique, innovative design with digital control panel and
display provides precision control and ease of use to match various
cleaning requirements.
PRODUCT DESCRIPTION
FUNCTION and FEATURES
Microprocessor-controlled equipment.
Oversized stainless steel tank.
1200W heating power.
Advance auto load following technology
Sweep frequency cleaning function.
Power control cleaning function.
3 customizable cleaning profile.
Adjustable timer.
LED display and tactile touch type control.
4
44
4
Power Input : available in 110V / 220V
Station Dimensions: 350(w) x 265(h) x325(d) mm
Weight: 8.8Kg
Cleaning Power: 200W
Temperature Range: Up to 70°C
Heating Element: PTC Heater
Heating Element Power: 1200W (peak)
Cleaning Frequency: 28Khz
Tank Capacity: 5 Liters
Tank Internal Dimension: 300 x 290 x 70 mm
SPECIFICATION
Specifications and functions are subject to change without prior notice.
13
1313
13
OPERATING GUIDELINES
To save the programmed cleaning profile, repeatedly press the
switch button until the display shows the word “SAVE”. Press the
start button to save the newly programmed profile into memory.
The display will jump to displaying segment “A” if save is
successful.
To set the heat up temperature repeatedly press the switch
button until the display shows the temperature view. Set the
temperature by pressing the multifunction adjustment buttons.
Temperature setting is adjustable from 25 to 70 degrees Celsius.
To set the overall cleaning time, ensure that the temperature is
shown on the display. Set the time by pressing the timer
adjustment buttons.
Start the cleaning process by pressing the Start button (“8”).
(Important! the system will not start unless the display is
reverted back to the temperature view)
If the heating function is enabled the system would start heating
up and engage the ultrasonic cleaning when the set temperature
has been reach. If the heating function is disabled the system
would immediately start the cleaning process. The system would
clean using the user programmed cleaning profile.
Default profile of Mode 6:
Segment A b C d E F
Power Level 100 000 100 000 100 000
Duration 15 10 15 10 15 10
Default profile of Mode 7:
Segment A b C d E F
Power Level 100 000 060 000 100 000
Duration 30 15 30 15 30 15
12
1212
12
OPERATING GUIDELINES
Place items to be cleaned into the tank with the cleaning liquid.
Repeatedly press the mode selection button to reach the desired
working mode. In this case mode “5”.
Set the temperature by pressing the multifunction adjustment
buttons. Temperature setting is adjustable from 25 to 70 degrees
Celsius.
Set the time by pressing the timer adjustment buttons.
Start the heat up by pressing the Start button (“8”).
If the heating function is enabled the system would start heating
up and commence the countdown timer when the set temperature
has been reach. If the heating function is disabled the system
would immediately start the countdown timer.
3. Mode 6 to 8: Programmable automated mode. These modes allows
the user program a 6 rotating segment cleaning profile.
Place items to be cleaned into the tank with the cleaning liquid.
Repeatedly press the mode selection button to reach the desired
working mode. In this case modes “6 to 8”.
Set the temperature by pressing the multifunction adjustment
buttons. Temperature setting is adjustable from 25 to 70 degrees
Celsius.
Press the switch button to access segment “A power level
adjustment.
Set the power level of segment “A” by pressing the multifunction
adjustment buttons. Power is adjustable from 0 to 100 levels. (100
highest, and 0 means no ultrasonic activity). To program a pause in
the ultrasonic cleaning simply press the down button until the
display shows “000” meaning no ultrasonic activity.
Set the duration of segment “A” by pressing the timer adjustment
buttons.
Press the switch button to proceed to programming the power and
time of the rest of the 6 segments.
5
55
5
SAFETY PRECAUTIONS
CAUTION:
Improper usage can cause serious injury to personnel
and/or damage to equipment. For your own safety, please observe
the ff. precautions.
Check each component after opening the package to make sure
everything is in good condition. If there are any suspected damage,
do not use the item and report the issue to your vendor.
Turn OFF the main power switch, unplug the device and drain tank
when moving the device from one location to another.
Do not strike or subject the main unit to physical shock. Use
carefully to avoid injury and damage to any part.
- Never drop or sharply jolt the unit.
- Contains delicate parts that may break if the unit is dropped.
Make sure the equipment is always grounded. Always connect
power to a grounded receptacle.
Do not use this equipment where there is a risk of causing a fire or
an explosion.
Do not allow liquids to come in contact with the control panel,
power receptacles, and internal circuitry. Ensure that these areas
are dry and free from moisture before utilizing the equipment.
Never operate cleaner if there is no liquid present in the tank.
temperature of liquid may reach as high as 100°C .
Use of acidic solvent or highly reactive liquids in the tank may
damage and perforate the tank causing damage to the internal
circuitry. Always drain and clean the tank after usage. This will
minimize chemical solvents from damaging the tank.
WARNING: The warnings, cautions, and instructions discussed in
this instruction manual cannot cover all possible scenarios and/or
conditions that could occur. It must be understood by the operator that
usage of any electrical equipment should be guided by common sense and
caution, these factors are beyond the scope of the machine.
6
66
6
SAFETY PRECAUTIONS
Never leave equipment running unattended.
Never use volatile/highly reactive solvents, including flammable
liquids and penetrating oils, to clean objects in the ultrasonic
cleaner.
Do not overload the tank. Overloading can cause inadequate
cleaning and may risk liquid spilling into electrical circuitry.
Ultrasonic transducers produce audible high pitched sound. Wear
proper protection gear to minimize effect of high pitched sound to
the operator.
Disconnect the plug from the power source if the unit will not be
used for a long period.
Use only genuine replacement parts.
- Turn off power and let the unit cool before replacing parts.
Do not alter the unit, specifically the internal circuitry, in any
manner.
Damage to ultrasonic cleaning machines due to acidic solvents or
highly reactive chemicals is NOT covered by the manufacturer’s
warranty.
Notice: The system uses ultrasonic transducers to generate the
cleaning action. Ultrasonic transducers produce highly audible noise.
The system’s auto load following feature varies the power given to
the ultrasonic transducers depending on load conditions. It is
normal for the noise generated to vary in frequency and intensity as
the system operates.
11
1111
11
OPERATING GUIDELINES
Start the cleaning process by pressing the Start button (“8”).
If the heating function is enabled the system would start heating
up and engage the ultrasonic cleaning when the set temperature
has been reach. If the heating function is disabled the system
would immediately start the cleaning process.
3. Mode 4: Power selection operating mode. This mode allows the user
to specify the power level.
Place items to be cleaned into the tank with the cleaning liquid.
Repeatedly press the mode selection button to reach the desired
working mode. In this case mode “4”.
Set the temperature by pressing the multifunction adjustment
buttons. Temperature setting is adjustable from 25 to 70
degrees Celsius.
Press the switch button to access power level adjustment. Set
the power level by pressing the multifunction adjustment
buttons. Power is adjustable from 60 to 100 levels. (100 highest)
Set the time by pressing the timer adjustment buttons.
Press the switch button again to revert back to the temperature
display/adjustment view. Start the cleaning process by pressing
the Start button (“8”). (Important! the system will not start
unless the display is reverted back to the temperature view)
If the heating function is enabled the system would start heating
up and engage the ultrasonic cleaning when the set temperature
has been reach. If the heating function is disabled the system
would immediately start the cleaning process. The system would
clean using the user specified power level.
4. Mode 5: Heater mode. This mode only engages the temperature
heat up. This mode is for pre-heating the cleaning liquid without
engaging the ultrasonic cleaning process. Useful for pre-soaking item
at a set temperature for a definite time without the use of the
ultrasonic cleaning.
10
1010
10
OPERATING GUIDELINES
E. MODE FUNCTIONS
1. Modes 1 and 2: High/Low power operating modes. Mode 1 allows
temperature heat up with continuous high power cleaning. While mode
2 allows temperature heat up with continuous low power cleaning.
Place items to be cleaned into the tank with the cleaning liquid.
Set the temperature by pressing the multifunction adjustment
buttons. Temperature setting is adjustable from 25 to 70 degrees
Celsius.
Repeatedly press the mode selection button to reach the desired
working mode. In this case mode “1 or 2”.
Set the time by pressing the timer adjustment buttons.
Start the cleaning process by pressing the Start button (“8”).
If the heating function is enabled the system would start heating
up and engage the ultrasonic cleaning when the set temperature
has been reach. If the heating function is disabled the system
would immediately start the cleaning process. If mode 1 is selected
the highest cleaning power will be used. If mode 2 is selected the
lowest cleaning power will be used.
Ultrasonic cleaning and heating will automatically stop when the
timer expires.
2. Mode 3: Sweep frequency mode. This mode allows temperature heat
up and continuous variation of the operating frequency.
Place items to be cleaned into the tank with the cleaning liquid.
Set the temperature by pressing the multifunction adjustment
buttons. Temperature setting is adjustable from 25 to 70 degrees
Celsius.
Repeatedly press the mode selection button to reach the desired
working mode. In this case mode “3”.
Set the time by pressing the timer adjustment buttons.
7
77
7
CONTROL PANEL GUIDE
LEGEND:
1 — Temperature / Power display
2 — Timer display
3 — Mode display
4 — Switch button. Switch between adjusting temperature or power.
5 — Multifunction adjustment button.
Increase or decrease the power or temperature settings.
6 — Mode selection button.
7 — Timer adjustment buttons. Pres + or - to increase or decrease time.
8 — Ultrasonic cleaning start button.
9 — Water drain pipe and valve.
1
2
3
4
6
7
8
5
9
AC power Plug
Main Power Switch
Back View
Front View
8
88
8
IMPORTANT REMINDERS:
1. Make sure the equipment is placed on a flat stable surface .
2. Ensure all function switches are OFF prior to reworking.
3.
Ensure all terminal connections are properly secured.
IMPORTANT: Please refer to the CONTROL PANEL GUIDE
page for buttons and display panel directory.
OPERATING GUIDELINES
A. INITIAL PROCEDURES
1. Ensure that the water drain valve is shut off before pouring any
cleaning liquid into the tank.
2. Attach a water drain tube to the water drain pipe.
3. Pour in the cleaning liquid. Do not over fill tank. Items to be cleaned
will displace liquid causing it to overflow.
4. Plug the device to the main power source using the power cord
provided in the package
5. With all function switches deactivated and all terminal connections
properly secured, switch ON the device by activating the main power
switch .
B. SETTING TEMPERATURE
1. Follow the initial procedures above, “A. INITIAL PROCEDURES”.
2. Place items to be cleaned into the tank with the cleaning liquid.
3. With the display showing the temperature. Indicated by the suffic
“C” (###C). The temperature can be set by pressing the multifunction
adjustment buttons. Temperature setting is adjustable from 25 to 70
degrees Celsius.
4. To disable the heating function simple press the down arrow button of
the multifunction adjustment button until the temperature display
shows the word “OFF” this indicates that the heating function is turned
off.
9
99
9
OPERATING GUIDELINES
5. To start the heating process simply press the Start button (button
“8”).
6. The system would start heating up and engage the ultrasonic
cleaning when the set temperature has been reach.
C. SETTING TIMER
1. Follow the initial procedures above, “A. INITIAL PROCEDURES”.
2. Place items to be cleaned into the tank with the cleaning liquid.
3. The cleaning time can be set by pressing the timer adjustment
buttons. Timer setting is adjustable from 10 seconds to 99 minutes.
4. To start the cleaning process simply press the Start button (button
“8”).
5. If the heating function is enabled the system would start heating up
and engage the ultrasonic cleaning when the set temperature has
been reach. If the heating function is disabled the system would
immediately start the cleaning process.
D. SETTING POWER
1. Follow the initial procedures above, “A. INITIAL PROCEDURES”.
2. Place items to be cleaned into the tank with the cleaning liquid.
3. The power setting function can be accessed when using the system
in mode 5 .(see Mode 5 function for details)
5. Press the Power/Temperature switch button (button “4”), to switch
from displaying the temperature to power. The display would switch
to showing a number with a suffix “P”. This indicate that the power
setting is begin displayed and can be adjusted.
6. Set the power by pressing the multifunction adjustment buttons.
Power setting is adjustable from 60 to 100 level.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

aoyue 9070 User manual

Type
User manual

Aoyue 9070 is an advanced high power ultrasonic cleaning system which incorporates the latest technologies to allow efficient and effective cleaning in the shortest amount of time.

Its large square stainless steel tank is specially suitable for cleaning oversized items such as PCBs, metal plates, boards and other objects with large surface area.

It has several advanced features such as temperature control, timer adjustment, sweep frequency, auto-load following, and power control.

Temperature control enables the system to quickly heat up to 50 degrees to the optimum cleaning temperature before engaging the ultrasonic cleaning process.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI