Marco MIX 1 Button Font, MIX 3 Button Font, MIX font – 3 Button, Una Font – 1 Button Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Marco MIX 1 Button Font Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
Instruction Manual
Machine P/N: 1000878# , 1000879# & 1000879FB
2
100mm
/ 4”
32mm
/ 1 ¼”
82.5mm
Scale 1:1
For drip tray only
100mm
NOTE: Check scale of template before cutting. Scale should be 1:1
Contents
1. Font Box Contents................................................................................................2
2. Counter Cut-Out.................................................................................................2
3. Installation..........................................................................................................4
No Drip Tray...............................................................................................4
Drip Tray...................................................................................................5
Connecting Hoses......................................................................................6
4. Operating Font...................................................................................................7
5. Cleaning & Maintenance......................................................................................7
Font Box Contents
3 & 4 Button Models
• MIX Font
• Vent Hosing
• Hot Water Hose
• Cold Water Hose
• Instruction Manual
•Button Identifier Tag
•Button Identifier Clip
Counter Cut Out
• The 105mm /4” cut out is only required for the font with drip tray.
• The font without drip tray require the 32mm / 1 ¼” cut out only.
• Use a 32mm/ 1 ¼” & a 105mm /4” circular hole saw piece to make the holes.
Single Button Model
• MIX Font
• Vent Hosing
• Hot Water Hose
• Instruction Manual
• SP9 Adaptor Kit
3
100mm
/ 4”
32mm
/ 1 ¼”
82.5mm
Scale 1:1
For drip tray only
100mm
NOTE: Check scale of template before cutting. Scale should be 1:1
Counter Cut Out
4
Installation
32mm / 1 ¼”
1. No Drip Tray
130 - 500mm
130 - 500mm
50mm
Hosing should be trimmed to ensure
continuous drop from font to boiler
5
Installation
The drain outlet on the drip
tray should be plumbed to
waste.
32mm/ 1 ¼”
100mm/ 4”
2. Drip Tray (sold seperately p/n. 2300268)
130 - 500mm
130 - 500mm
50mm
Hosing should be trimmed to ensure
continuous drop from font to boiler
6
Hot Water
Vent
Power
Cold Water
Hot Water
Vent
Power
Connecting Hoses
Vent
Hot Water
SP9 Boiler
3 & 4 Button Font Connections Single Button Font Connections
SP9 Boiler Connection
7
Operating Font
Cleaning & Maintenance
RISK OF SCALDING
Turn off the boiler before cleaning to
prevent accidental triggering of a
dispense.
Beware of accidentally operating the font –
especially when cleaning around the push
buttons.
The exterior of this font may be cleaned
with a damp cloth and a light detergent.
Do not use abrasive cloths or creams, as
this will spoil the finish of the font.
1. Push & Hold
2. Push & Release
Quantity
85°
100
Marco Beverage Systems Limited.
63d Heather Road,
Sandyford Industrial Estate,
Dublin 18
t: +353 (0)1 295 2674
f: +353 (0)1 295 3715
e: sales@marco.ie
www.marcobeveragesystems.com
NSF/ANSI 4