Z-42-Z-42-CD Wood Burning Fireplace

kozy heat Z-42-Z-42-CD Wood Burning Fireplace Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the kozy heat Z-42-Z-42-CD Wood Burning Fireplace Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Please leave these reference guides at the installaon locaon unl the installaon is nished. See owners manual for full installaon and nishing
instrucons before making nal decisions as informaon is subject to change.
Specicaons (all measurements are in inches)
Wall Enclosure Rough Opening
Clearances to Combusbles
Z42/Z42CD Wood Burning Fireplace
ELECTRICAL ACCESS: LEFT SIDE
E F G H I J
12 48 16 12 8 81
8/20
Combuson Air Pipe
Model BTU
*Peak
Height Front Width Back Width Depth Glass Viewing
Area
Actual Framing Actual Framing Actual Framing Actual Framing
Z42/Z42CD 12,850
36,231/*49,133 38 381/4 42 421/2 42 421/2 2515/16 261/4 25 x 151/2
A B C
381/4 421/2 261/4
Placement Clearance Requirements
Combusble Mantel
Dimension ALB
K 651/4
L 921/4
M 20
N 54
O 261/4
Combuson Air Pipe
Combuson Air Pipe
Must allow 6”
for Combuson
Air Pipe
K
L
M
N
O
N
N
O
12” from nishing
edge to side wall
A
B
C
Hearth Extension
T
U
Finishing Dimensions
Combuson Air Intake Requirements / Conguraons
V W X
513/8 12 16 D x 48 W
P Q R S T
53 393/8 343/4 57 351/2
U
103/4
Each square represents
1” of mantel projecon
NonCombusble
Finishing Material Only
Combusble Finishing
Material Allowed
R
S
Q
P
Combusble Finishing Material Allowed
NonCombusble Finishing Material Only
T
U
45o
8”
11”
Combusble Mantel Clearances
V
W
X
Metal Sealing Strips
SandCement Grout
Floor
Finishing Edge
14”
1 2
3 4
Metal sealing strip centered under
replace and hearth extension for
the full width of the replace
Air Trap
Terminaon needs
to be above air
intake collar
8”
12”
An oponal Air Trap can be used in
venng conguraons 1 through 3.
An Air Trap is REQUIRED on venng
conguraon 4 when the combuson
air intake is above the air intake collar
on the replace
8/20
Chimney Locaon and Consideraons
Chimney Installaon
SLANTED ROOFS
FLAT ROOFS
Chimney must extend
3 feet above roof 36”
Chimney must extend 2 feet above
any poron of the roof or adjacent
structures within 10 feet of chimney
Chimney must extend 2 feet above
any poron of the roof or adjacent
structures within 10 feet of chimney
Chimney must extend
3 feet above roof 36”
10 Ft.
2” Clearance 2” Clearance
2” Clearance 2” Clearance
Min 2” Clearance
16”
Ac Insulaon shield
Firestop
Firestop
Firestop
A Firestop must be installed
where chimney passes
through each oor level
An Ac Insulaon Shield is
required for protecon where
chimney passes into ac space
Aer the Anchor Plate, connect the rst
chimney secon per chimney manufacturer’s
installaon instrucons
Anchor Plate
8/20
/