  • Hello! I am an AI chatbot trained to assist you with the Comtech EF Data CDM-750 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
CDM-750
Advanced High-Speed Trunking Modem
Installation and Operation Manual
For Firmware Version 1.6.1 or higher
Part Number MN-CDM750
Revision 2
IMPORTANT NOTE: The information contained in this document supersedes all previously published
information regarding this product. Product specifications are subject to change without prior notice.
Copyright © 2012 Comtech EF Data. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161
iii
TABLE OF CONTENTS
TABLE OF CONTENTS .............................................................................................................. III
TABLES ..................................................................................................................................... XII
FIGURES .................................................................................................................................. XIII
PREFACE .................................................................................................................................. XV
AboutthisMa
nual..............................................................................................................................xv
ReportingCommentsorSuggestionsConcern ingthisManual.............................................................................xv
ConventionsandReferences...............................................................................................................xv
PatentsandTrademarks...........................................................................................................................................xv
Warnings,Cautions,andNotes................................................................................................................................xv
ExamplesofMultiHazardNotices..........................................................................................................................xvi
RecommendedStandardDesignations..................................................................................................................xvi
MetricConversion....................................................................................................................................................xvi
Safetyan
dCompliance.......................................................................................................................xvi
ElectricalSafety andCompliance.............................................................................................................................xvi
ElectricalInstallation................................................................................................................................................xvii
OperatingEnvironment...........................................................................................................................................xvii
European Union RadioEqui pme ntandTelecommunicationsTerminalEquipment(R&TTE)
Directive(1999/5/EC )andEN 3014891.......................................................................................................xvii
European Union Electromagn etic Compatibility(EMC )Directive(2004/ 108/EC) .......................xvii
EuropeanUnionLowVoltageDirective(LVD)(2006/9
5/EC)............................................................xviii
EuropeanUnionRoHSDirective(2002/95/EC).................................................................................xviii
EuropeanUnionTelecommunicationsTerminalEquipmentDirective(91/263/EEC)........................xix
CEMark...............................................................................................................................................xix
WarrantyPolicy.................................................................................................................................xix
LimitationsofWarranty...........................................................................................................................................xix
ExclusiveRemedies....................................................................................................................................................xx
GettingHelp......................................................................................................................................xxi
ContactingComtechEFData...................................................................................................................................xxi
Retur
ningaProductforUpgradeorRepair...........................................................................................................xxii
CHAPTER 1. INTRODUCTION ............................................................................................. 1–1
1.1 Overview..............................................................................................................................1–1
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
iv
1.2 CDM750FunctionalDescription...........................................................................................1–1
1.3 CDM750Features................................................................................................................1–5
1.3.1 PhysicalDescription..............................................................................................................................1–6
1.3.2 DimensionalEnvelope..........................................................................................................................1–7
1.3.3 CDM750ExternalPhysicalFeat ures...................................................................................................1–8
1.3.3.1FrontPanel........................................................................................................................1–8
1.3.3.2RearPanel.........................................................................................................................1–9
1.3.3.2.1 RearPanelStandardFeatures.....................................................................................1–9
1.3.3.2.2 RearPanelOptionalFe
atures...................................................................................1–10
1.4 CDM750Specifications...................................................................................................... 1–11
1.4.1 SystemSpecifications.........................................................................................................................1–11
1.4.2 EnvironmentalandPhysical...............................................................................................................1–11
1.4.3 BaseUnitConnectors.........................................................................................................................1–12
1.4.4 TestFunctions.....................................................................................................................................1–12
1.4.5 Modulator(DualIF).............................................................................................................................1–12
1.4.6 Demodulator(DualIF)........................................................................................................................1–13
1.4.7 AdaptiveCodingandModulation(ACM)..........................................................................................1–14
1.4.8 DoubleTalk
TM
CarrierinCarrier
®
(CnC)..............................................................................................1–15
1.4.9 RegulatoryCompliance......................................................................................................................1–15
1.4.10 StandardAssemblies..........................................................................................................................1–15
1.4.11 OptionalAssemblies...........................................................................................................................1–16
CHAPTER 2. INSTALLATION .............................................................................................. 2–1
2.1 UnpackingandInspectingtheShipment...............................................................................2–1
2.2 InstallingintoaRackEnclosure.............................................................................................2–2
2.2.1 InstallingtheOptionalRearMountingSupportBracketsKit............................................................2–4
2.2.2 InstallingtheOptionalBeari
nglessRackSlideSet..............................................................................2–6
CHAPTER 3. REAR PANEL CONNECTIONS ...................................................................... 3–1
3.1 CablingConnectionTypes.....................................................................................................3–1
3.1.1 CoaxialCableConnections...................................................................................................................3–1
3.1.1.1Type‘BNC’.........................................................................................................................3–2
3.1.1.2Type‘TNC’.........................................................................................................................3–2
3.1.1.3Type‘N’.............................................................................................................................3–2
3.1.1.4Type‘F’..............................................................................................................................3–3
3.1.1.5Type‘SMA’(SubminiatureVersion‘A’).............................................................................3–3
3.1.2 DSubmi
niatureCableConnections....................................................................................................3–3
3.1.3 CircularCableConnections..................................................................................................................3–4
3.1.4 RJ45,RJ48CableConnections...........................................................................................................3–4
3.2 CDM750CablingConnections..............................................................................................3–5
3.2.1 IFConnectorGroup..............................................................................................................................3–7
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
v
3.2.1.1RxConnectors...................................................................................................................3–7
3.2.1.2TxConnectors...................................................................................................................3–7
3.2.1.3J10|TXMONConnector,Type‘SMA’..............................................................................3–7
3.2.2 UtilityConnectorGroup.......................................................................................................................3–8
3.2.2.1J1|ALARMConnector,DB15M.......................................................................................3–8
3.2.2.2J2|REDUNDANCYConnector,DB9F...............................................................................3–9
3.2.2.3J3|REMOTEConnector,DB9M.......................................................................................3–9
3.2.2.4J4|MGM
TConnector,RJ45F........................................................................................3–10
3.2.2.5J8|EXTREFConnector, BNC..........................................................................................3–10
3.2.3 TerrestrialDataConnectorGroup.....................................................................................................3–11
3.2.3.1J5|DATA,J6|DATAConnections,RJ45F.....................................................................3–11
3.2.3.2J7|OPTICALConnection,1000BaseSXCage.................................................................3–12
3.2.3.2.1 OptionalOpt
icalGigabitEthernetInterface(CEFDP/NIC0000058)........................3–12
3.2.3.3PIICDataInterfaceSlots..................................................................................................3–13
3.3 CDM750GroundandPowerConnections..........................................................................3–14
3.3.1 ChassisGroundInterface...................................................................................................................3–14
3.3.2 115V/230VAlternatingCurrent(AC)PowerInterface(Standard)..................................................3–15
3.3.2.1ACOperationApplyingPower......................................................................................3–15
3.3.2.2ACOperationRepla
cingFuses.....................................................................................3–16
3.3.3 48VDirectCurrent(DC)PowerInterface(Optional)(FUTURE).......................................................3–17
3.3.3.1DCOperationApplyingPower.....................................................................................3–18
3.3.3.2DCOperationReplacingFuses.....................................................................................3–19
CHAPTER 4. UPDATING FIRMWARE ................................................................................. 4–1
4.1 UpdatingFirmwareviatheInternet......................................................................................4–1
4.2 GettingStarted:PreparingfortheFi
rmwareDownload........................................................4–2
4.3 DownloadingandExtractingtheFirmwareUpdate...............................................................4–6
4.4 PerformingtheEthernetFTPUploadProcedure....................................................................4–8
CHAPTER 5. FRONT PANEL OPERATION ......................................................................... 5–1
5.1 Introduction.........................................................................................................................5–1
5.1.1 LEDIndicators........................................................................................................................................5–2
5.1.2 Keypad...................................................................................................................................................5–3
5.1.3 VacuumFluorescentDisplay(VFD).....................................................................................................5–4
5.1.3.1OpeningScreen.................................................................................................................5–4
5.1.3.2ScreenSaver......................................................................................................................5–4
5.2 CDM750Fr
ontPanelMenus................................................................................................5–5
5.2.1 SELECT:(Main)Menu...........................................................................................................................5–6
5.2.2 SELECT:Configuration..........................................................................................................................5–6
5.2.2.1CONFIG:Intf(ConfigureInterface)....................................................................................5–7
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
vi
5.2.2.1.1 SingleStreamModevs.MultiStreamModeOperation.............................................5–8
5.2.2.1.2 (CONFIG)INTF:PIICX=G703....................................................................................5–10
5.2.2.1.3 (CONFIG)INTF:PIICX=OC3......................................................................................5–14
5.2.2.1.4 (CONFIG)INTF:GBEIX...............................................................................................5–17
5.2.2.1.5 (CONFIG)INTF:Optical..............................................................................................5–20
5.2.2.2CONFIG:Tx......................................................................................................................5–20
5.2.2.2.1 (CONFIG)Tx:IF..........................................................................................................5–20
5.2.2.2.2 (CONFIG)Tx:Freq(Freq
uency).................................................................................5–20
5.2.2.2.3 (CONFIG)Tx:Power..................................................................................................5–21
5.2.2.2.4 (CONFIG)Tx:Frame..................................................................................................5–21
5.2.2.2.5 (CONFIG)Tx:Mod(Modulation)...............................................................................5–22
5.2.2.2.6 (CONFIG)Tx:Data.....................................................................................................5–22
5.2.2.2.7 (CONFIG)Tx:Pilot.....................................................................................................5–24
5.2.2.3CONFIG:Rx......................................................................................................................5–26
5.2.2.3.1 (CONFIG)Rx:IF..........................................................................................................5–26
5.2.2.3.2 (CONFIG)Rx:Freq(Freq
uency).................................................................................5–26
5.2.2.3.3 (CONFIG)Rx:Frame..................................................................................................5–26
5.2.2.3.4 (CONFIG)Rx:Mod(Modulation)...............................................................................5–27
5.2.2.3.5 (CONFIG)Rx:Data.....................................................................................................5–27
5.2.2.3.6 (CONFIG)Rx:Pilot.....................................................................................................5–27
5.2.2.3.7 (CONFIG)Rx:EsNo....................................................................................................5–28
5.2.2.4CONFIG:Clocks................................................................................................................5–29
5.2.2.4.1 (CONFIG)Clocking:FreqRef.....................................................................................5–29
5.2.2.4.2 (CONFIG)Clocking:IntRefAdjust............................................................................5–29
5.2.2.5CONFIG:AC
M(AdaptiveCodingandModulation).........................................................5–30
5.2.2.5.1 (CONFIG)ACMConfig:Min/MaxModCod...............................................................5–30
5.2.2.5.2 (CONFIG)ACMConfig:UnlockAction......................................................................5–30
5.2.2.5.3 (CONFIG)ACMConfig:TargetEs/NoMargin...........................................................5–31
5.2.2.5.4 (CONFIG)ACMConfig:Degradation.........................................................................5–31
5.2.2.6CONFIG:CnC....................................................................................................................5–33
5.2.2.6.1 (CONFI
G)CarrierinCarrier:Mode...........................................................................5–33
5.2.2.6.2 (CONFIG)CarrierinCarrier:SearchDelay................................................................5–33
5.2.2.7CONFIG:Mask.................................................................................................................5–34
5.2.2.8CONFIG:Remote(RemoteControl)................................................................................5–35
5.2.2.8.1 (CONFIG)RemoteControl:SerialorSer+Ethernet...................................................5–35
5.2.2.8.2 (CONFIG)RemoteControl:Inband...........................................................................5–36
5.2.2.9CONFIG:IP.......................................................................................................................5–37
5.2.2.9.1 (CONFIG)IPConfig:Addresses..................................................................................5–37
5.2.2.9.2 (CONFI
G)IPConfig:SNMP........................................................................................5–38
5.2.2.10 CONFIG:Comp............................................................................................................5–40
5.2.3 SELECT:Test.........................................................................................................................................5–41
5.2.3.1TEST:Mode.....................................................................................................................5–41
5.2.3.2TEST:BERT.......................................................................................................................5–43
5.2.3.2.1 TEST:BERTÆConfig................................................................................................5–43
5.2.3.2.2 TEST:BERTÆMonitor.............................................................................................5–43
5.2.3.3TEST:Comp.....................................................................................................................5–44
5.2.4 SELECT:Mo
nitor..................................................................................................................................5–45
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
vii
5.2.4.1Monitor:LiveAlarms......................................................................................................5–45
5.2.4.2Monitor:StoredEvents...................................................................................................5–46
5.2.4.3Monitor:ACM.................................................................................................................5–46
5.2.4.4Monitor:RxParams(RxParameters).............................................................................5–46
5.2.4.5Monitor:CnC(CarrierinCarrierParameters)................................................................5–47
5.2.4.6Monitor:Stats(Statistics)................................................................................................5–47
5.2.4.6.1 Monitor:StatsÆIP..................................................................................................5–48
5.2.4.6.2 Monitor:StatsÆBasebandFraming.......................................................................5–49
5.2.4.6.3 Mo
nitor:StatsÆCompression................................................................................5–50
5.2.4.7Monitor:Buffer...............................................................................................................5–51
5.2.5 SELECT:Info(Information).................................................................................................................5–52
5.2.5.1Info:ID.............................................................................................................................5–52
5.2.5.2Info:Intf..........................................................................................................................5–52
5.2.5.3Info:Tx............................................................................................................................5–53
5.2.5.4Info:Rx............................................................................................................................5–53
5.2.5.5Info:Clocks......................................................................................................................5–54
5.2.5.6Info:ACM........................................................................................................................5–54
5.2.5.7Info:CnC..........................................................................................................................5–54
5.2.5.8Info:Mis
c.........................................................................................................................5–54
5.2.5.9Info:Remote...................................................................................................................5–55
5.2.5.10 Info:Comp...................................................................................................................5–55
5.2.6 SELECT:St ore/Ld(Store/Load)...........................................................................................................5–56
5.2.7 SELECT:Utility......................................................................................................................................5–57
5.2.7.1Utility:SetRTC................................................................................................................5–57
5.2.7.2Utility:DisplayBrightness...............................................................................................5–57
5.2.7.3Utility:LED.......................................................................................................................5–57
5.2.7.4Utility:1:1........................................................................................................................5–58
5.2.7.5Utili
ty:1:N.......................................................................................................................5–58
5.2.7.6Utility:CircuitID..............................................................................................................5–59
5.2.7.7Utility:Firmware.............................................................................................................5–59
5.2.7.7.1 (UTILITY)FirmwareImages:Info...............................................................................5–59
5.2.7.7.2 (UTILITY)FirmwareImages:Select...........................................................................5–60
5.2.8 SELECT:ODU(OutdoorUnit).............................................................................................................5–60
5.2.8.1ODU:LNB:PwrSupply+Ref...............................................................................................5–60
5.2.8.1.1 (ODU)LNB:PwrSupply+Ref:PSUand10MHz...........................................................5–60
5.2.8.1.2 (ODU
)LNB:PwrSupply+Ref:PSUmonitor..................................................................5–61
5.2.9 SELECT:FAST.......................................................................................................................................5–62
5.2.9.1FAST:Options..................................................................................................................5–62
5.2.9.1.1 (FAST)FASTOptions:Set..........................................................................................5–63
5.2.9.1.2 (FAST)FASTOptions:View........................................................................................5–63
5.2.9.2FAST:DemoMode..........................................................................................................5–63
5.2.9.3FAST:CnC........................................................................................................................5–64
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
viii
CHAPTER 6. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT ......................... 6–1
6.1 Introduction.........................................................................................................................6–1
6.2 EthernetManagementInterfaceProtocols...........................................................................6–2
6.3 SNMPInterface....................................................................................................................6–2
6.3.1 ManagementInformationBase(MIB)Files........................................................................................6–3
6.3.2 SNMPCommunityStrings....................................................................................................................6–3
6.3.3 SNMPTraps...........................................................................................................................................6–4
6.4 TelnetInterface....................................................................................................................6–5
6.4.1 TelnetOperationviaHyperTerminal...................................................................................................6–5
6.5 WebServer(H
TTP)Interface.................................................................................................6–7
6.5.1 UserLogin..............................................................................................................................................6–7
6.5.2 WebServerInterfaceOperationalFeatures....................................................................................6–8
6.5.2.1Navigation.........................................................................................................................6–8
6.5.2.2PageSections....................................................................................................................6–8
6.5.2.3ActionButtons..................................................................................................................6–8
6.5.2.4DropdownLists................................................................................................................6–8
6.5.2.5TextorDataEntry.............................................................................................................6–9
6.5.3 WebServerInterfaceMen
uTree.....................................................................................................6–9
6.5.4 WebServerInterfacePageDescriptions...........................................................................................6–10
6.5.4.1Homepages....................................................................................................................6–10
6.5.4.1.1 Home|Home...........................................................................................................6–10
6.5.4.1.2 Home|ContactandHome|Support......................................................................6–11
6.5.4.2Admin(Administration)pages........................................................................................6–12
6.5.4.2.1 Admin|Access.........................................................................................................6–12
6.5.4.2.2 Admin|SNMP..........................................................................................................6–14
6.5.4.3Configurationpages........................................................................................................6–15
6.5.4.3.1 Configuration|Mo
dem............................................................................................6–15
6.5.4.3.2 Configuration|Utilities............................................................................................6–16
6.5.4.3.3 Configuration|Test..................................................................................................6–17
6.5.4.3.4 Configuration:LNB(LowNoiseBlockDownConverter)...........................................6–18
6.5.4.4Statuspages....................................................................................................................6–19
6.5.4.4.1 Status|Status...........................................................................................................6–19
6.5.4.4.2 Status|Logs.............................................................................................................6–20
6.5.4.4.3 Status|In
fo..............................................................................................................6–21
6.5.4.4.4 Status|Firmware.....................................................................................................6–22
6.5.4.4.5 Status|ACM.............................................................................................................6–23
6.5.4.4.6 Status|IPStatistics..................................................................................................6–24
6.5.4.4.7 Status|BBStatistics.................................................................................................6–25
6.5.4.5Interfacespages..............................................................................................................6–26
6.5.4.5.1 Interfaces|Ethernet................................................................................................6–27
6.5.4.5.2 Interfaces|PIIC(PlugInIn
terfaceCard)..................................................................6–28
6.5.4.6TxGraphpages(Minutes/Hours/Days)........................................................................6–30
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
ix
6.5.4.7RxGraphpages(Minutes/Hours/Days)........................................................................6–33
CHAPTER 7. SERIAL-BASED REMOTE PRODUCT MANAGEMENT ................................ 7–1
7.1 Introduction.........................................................................................................................7–1
7.2 EIA485.................................................................................................................................7–2
7.3 EIA232.................................................................................................................................7–3
7.4 RemoteCommandsandQueriesOverview........................................................................... 7–3
7.4.1 BasicProtocol........................................................................................................................................7–3
7.4.2 PacketStructure....................................................................................................................................7–3
7.4.2.1StartofPacket...................................................................................................................7–4
7.4.2.2TargetA
ddress..................................................................................................................7–4
7.4.2.3AddressDelimiter..............................................................................................................7–5
7.4.2.4InstructionCode................................................................................................................7–5
7.4.2.5InstructionCodeQualifier.................................................................................................7–5
7.4.2.6OptionalMessageArguments...........................................................................................7–6
7.4.2.7EndofPacket....................................................................................................................7–6
7.5 RemoteCommandsandQueries...........................................................................................7–7
7.5.1 TableIndexes.........................................................................................................................................7–7
7.5.2 TxParameters.....................................................................................................................................7–10
7.5.3 RxParameters.....................................................................................................................................7–13
7.5.4 IPPacketParameters..........................................................................................................................7–16
7.5.5 UnitParameters..................................................................................................................................7–18
7.5.6 ACMParameters.................................................................................................................................7–26
7.5.7 PIICInterfa
ceParameters...................................................................................................................7–27
7.5.8 BulkConfigurationStrings..................................................................................................................7–30
7.5.9 ODUParameters.................................................................................................................................7–32
7.5.10 ModemInformation...........................................................................................................................7–33
7.5.11 ModemPerformanceIndication.......................................................................................................7–37
7.5.12 Redu
ndancyCont rol ...........................................................................................................................7–42
APPENDIX A. FAST OPTIONS AND ACTIVATION PROCEDURE .................................... A–1
A.1 FASTSystemOverview.........................................................................................................A–1
A.2 FASTActivationProcedure....................................................................................................A–2
APPENDIX B. PIIC (PLUG-IN INTERFACE CARD) MODULES ......................................... B–1
B.1 Introduction.........................................................................................................................B–1
B.1.1 TypicalPIICModuleInstallation...........................................................................................................B–2
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
x
B.2 OptionalPIICModules..........................................................................................................B–4
B.2.1 G.703E3/T3/STS1PIICModule(CEFDP/NPL0000795).................................................................B–4
B.2.1.1 G.703E3/T3/STS1PIICModuleSummaryofSpecifications............................................B–5
B.2.1.1.1 GeneralSpecifications................................................................................................B–5
B.2.1.1.2 InterfaceSpecifications..............................................................................................B–5
B.2.2 STM1CopperPIICModuleKit(CEFDP/NKT0000255) ...................................................................B–6
B.2.2.1 STM1Coppe
rPIICModuleSummaryofSpecifi cations...................................................B–7
B.2.3 OC3Single/MultiModePIICModuleKits(CEFDP/NKT000025X).................................................B–8
B.2.3.1 OC3Single/MultiModePIICModuleSummaryofSpecifications...................................B–9
APPENDIX C. ADAPTIVE CODING AND MODULATION (ACM) OPTION ........................ C–1
C.1 Introduction.........................................................................................................................C–1
C.2 Background..........................................................................................................................C–2
C.2.1 ACMOp erationalLinkExample...........................................................................................................C–4
C.3 ACMSyst
emDescription.......................................................................................................C–6
C.4 CDM750ACMScheme.........................................................................................................C–8
C.4.1 TargetEs/NoMargin.............................................................................................................................C–8
C.4.2 DistortionAdaptation/ModulationTypeImpairment.....................................................................C–9
C.4.3 Pilots.....................................................................................................................................................C–10
C.4.4 LongandShortFrames.......................................................................................................................C–10
C.4.5 MonotonicOperation.........................................................................................................................C–10
C.4.6 ModCodSel
ection...............................................................................................................................C–12
C.5 ConfiguringACMintheCDM750....................................................................................... C–14
C.5.1 ACMConfigurationviatheFrontPanel.............................................................................................C–16
C.5.2 ACMConfigurationviatheCDM750WebServerInterface...........................................................C–17
C.6 MonitoringACMPerformanceandStatistics.......................................................................C–18
C.6.1 ACMCongestionControl....................................................................................................................C–19
C.6.2 NotesandRecommendations...........................................................................................................C–20
C.6.3 ACMSu
mmaryofSpecifications.....................................................................................................C–21
APPENDIX D. DOUBLETALK CARRIER-IN-CARRIER (CNC) OPTION ............................ D–1
D.1 Introduction.........................................................................................................................D–1
D.1.1 WhatisDoubleTalkCarrierinCarrier?...............................................................................................D–1
D.2 ApplicationRequirements....................................................................................................D–2
D.3 OperationalDetails...............................................................................................................D–4
D.4 SystemFunctionalityandOperationalConsiderations..........................................................D–5
D.4.1 DoubleTalkCarrierinCarrierCancellationProc ess ...........................................................................D–8
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
xi
D.4.2 MarginRequirements...........................................................................................................................D–9
D.4.3 CarrierinCarrierLatency.....................................................................................................................D–9
D.4.4 CarrierinCarrierandAdaptiveCodingandModulation(ACM ).....................................................D–10
D.4.5 CarrierinCarrierLinkDesign.............................................................................................................D–10
D.4.6 SymmetricDataRateLink..................................................................................................................D–11
D.4.6.1 AsymmetricDataRateLink.............................................................................................D–13
D.4.6.2 PowerLimitedLinks........................................................................................................D–14
D.4.7 CommissioningandDeployingCarrierinC
arrier.............................................................................D–16
D.5 OperationalReferences......................................................................................................D–17
D.5.1 CalculatingaCarrierinCarrierLinkBudget......................................................................................D–17
D.5.2 Estimating/CalculatingCnCRatio.....................................................................................................D–18
D.5.2.1 EstimatingCnCRatiofromLST/EIRP.............................................................................D–18
D.5.2.2 CalculatingCnCRatiofromCarriertoNoiseRatio(C/N)onaSpe
ctrumAnalyzer.........D–19
D.5.3 CalculatingCnCRatioandPSDRatiofromSatmast er......................................................................D–20
D.6 DoubleTalkCarrierinCarrierSpecifications........................................................................D–20
D.7 CarrierinCarrierSummary.................................................................................................D–20
D.8 Glossary..............................................................................................................................D–21
APPENDIX E. ES/NO MEASUREMENT .............................................................................. E–1
APPENDIX F. ETHERNET NETWORK CONFIGURATION .................................................. F–1
F.1 Introduction..........................................................................................................................F–1
F.2 EthernetRoutersandSwitches..............................................................................................F–1
F.3 Eth
ernetConfigurationExamples...........................................................................................F–2
F.3.1 EthernetNetworkOverview.................................................................................................................F–2
F.4 CDM750EthernetOverview.................................................................................................F–3
F.4.1 EthernetInterfaces................................................................................................................................F–3
F.4.2 EthernetOverhead................................................................................................................................F–4
APPENDIX G. ETHERNET STATISTICS AND STATUS REPORTING .............................. G–1
G.1 Introduction.........................................................................................................................G–1
G.2 DataFlowDiagram...............................................................................................................G–1
G.3 StatisticsItems.....................................................................................................................G–3
G.3.1 EthernetDataStatistics........................................................................................................................G–3
G.3.2 FramingandB
asebandStatistic s.........................................................................................................G–3
G.3.3 StatusItems...........................................................................................................................................G–4
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
xii
G.3.4 BERTesting............................................................................................................................................G–4
G.3.5 ACMModulatorStatus.........................................................................................................................G–4
G.3.6 ACMDemodulatorStatus....................................................................................................................G–4
G.3.7 CnCStatus..............................................................................................................................................G–4
APPENDIX H. FEC (FORWARD ERROR CORRECTION) .................................................. H–1
H.1 Introduction.........................................................................................................................H–1
H.2 DVBS2:LDPCandBCH..........................................................................................................H–1
H.2.1 RangeofDataRates..............................................................................................................................H–2
H.2.2 BER,QEF,Eb/No,Es/NoSpectralEfficiency,andO
ccupiedBandwidth...........................................H–2
TABLES
Table11.FASTandFASTaccessibleHardwareOptions..........................................................................1–4
Table31.CDM750RearPanelConnectors.............................................................................................3–6
Table51.CDM750FrontPanelMenuMatrix.........................................................................................5–5
Table52.SymbolRate/DataRateRangeforStandardFECFrame(DVBS2StandardFECFrame=64,800
bits).................................................................................................................................................5–25
TableC1.AC
MExampleforStandardFECFrame(64,800bits)...............................................................C–2
TableC2.ModCodComparison:ACMvs.CCM........................................................................................C–3
TableC3.TurningMarginintoAdditionalCapacity.................................................................................C–5
TableC4.ModulationTypeImpairment................................................................................................C–10
TableC5.SpectralEfficiencyandIdealEs/NobyMo
dCod....................................................................C–11
TableC6.DataRatebyOptionSymbolRate..........................................................................................C–15
TableD1.SpectralEfficiencyusingDoubleTalkCarrierinCarrier..........................................................D–7
TableE1.CDM750Co+No/NotoC/N(Es/No)andEb/No(dB)forDVBS2QPSKand8PSK..................E–3
TableE2.CDM750Co+No/NotoC/N(Es/No)andEb/No(dB
)forDVBS216APSKand32APSK..........E–4
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
xiii
FIGURES
Figure11.CDM750AdvancedHighSpeedTrunkingModem................................................................1–1
Figure12.CDM750DimensionalEnvelope............................................................................................1–7
Figure13.CDM750FrontPanelView.....................................................................................................1–8
Figure14.CDM750RearPanelView......................................................................................................1–9
Figure15.70/140MHzInputLevelvs.SymbolRate.............................................................................1–13
Figure16.LBandInp
utLevelvs.SymbolRate......................................................................................1–14
Figure21.UnpackingandInspectingtheShipment................................................................................2–1
Figure22.InstallingintoaRackEnclosure..............................................................................................2–3
Figure23.InstallingtheOptionalRearMountingSupportBracketsKit.................................................2–4
Figure24.InstallingtheOp
tionalBearinglessRackSlideSet..................................................................2–6
Figure31.CoaxialConnectorExamples...................................................................................................3–1
Figure32.DSubminiatureConnectorExamples.....................................................................................3–3
Figure33.CDM750CablingConnections...............................................................................................3–5
Figure34.TypicalSFPModuleInstallation............................................................................................3–12
Figure35.TypicalPIICModuleInstallation...........................................................................................3–13
Figure36.CD
M750ChassisGroundInterface......................................................................................3–14
Figure37.CDM750ACPowerInterface...............................................................................................3–15
Figure38.ApplyingACPowertotheCDM750.....................................................................................3–15
Figure39.ReplacingCDM750ACFuses...............................................................................................3–16
Figure310.CDM750DCPowerInterfa
ce.............................................................................................3–17
Figure311.ApplyingDCPowertotheCDM750...................................................................................3–18
Figure312.ReplacingCDM750DCFuses.............................................................................................3–19
Figure51.CDM750FrontPanelView.....................................................................................................5–1
Figure52.MACLearningOperations.....................................................................................................5–19
Figure53.LoopbackTestModes...........................................................................................................5–42
Figure61.CD
M750Homepage............................................................................................................6–10
Figure62.Home|ContactandHome|Supportpages........................................................................6–11
Figure63.Admin|Accesspage.............................................................................................................6–12
Figure64.Admin|SNMPpage.............................................................................................................6–14
Figure65.Configuration|Modempage...............................................................................................6–15
Figure66.C
onfiguration|Utilitiespage...............................................................................................6–16
Figure67.Configuration|Testpag e.....................................................................................................6–17
Figure68.Configuration|LNBpage.....................................................................................................6–18
Figure69.Status|Statuspage..............................................................................................................6–19
Figure610.Status|Logspage...............................................................................................................6–20
Figure611.Status|Infopage...............................................................................................................6–21
Figure612.St
atus|FirmwareInfopage...............................................................................................6–22
Figure613.Status|ACMStatuspage...................................................................................................6–23
Figure614.Status|IPStatisticspage...................................................................................................6–24
Figure615.Status|BBStatisticspage..................................................................................................6–25
Figure616.Interfaces|Ethernetpage..................................................................................................6–27
Figure617.In
terfacespage...................................................................................................................6–28
Figure618.TxGraphpages(TxHourspageshown)...............................................................................6–30
Figure619.RxGraphpages(RxHourspageshown)...............................................................................6–33
CDM-750 Advanced High-Speed Trunking Modem Revision 2
Table of Contents MN-CDM750
xiv
FigureB1.TypicalPIICModuleInstallation.............................................................................................B–2
FigureB2.G.703E3/T3/STS1PIICModule.............................................................................................B–4
FigureB3.G.703E3/T3/STS1PIICModuleBlockDiagram.....................................................................B–4
FigureB4.G.703E3/T3/STS1PIICModulePanelConnectors................................................................B–4
FigureB5.STM1CopperPIICModuleKit(CEFDP/NKT0000255)........................................................B–6
FigureB6.STM1CopperPIICModul
eSFPInstallation........................................................................B–6
FigureB7.OC3SingleModeorMultiModePIICModuleKit(CEFDP/NKT000025X)..........................B–8
FigureB8.OC3SingleModeorMultiModePIICModuleSFPInstallation..........................................B–8
FigureC1.D
ownlinkMarginvs.AverageLinkAvailability.......................................................................C–4
FigureC2.UserThroughputvs.TimeandFades.....................................................................................C–5
FigureC3.ACMoverSatelliteGenericExample..................................................................................C–7
FigureC4.SingleHopLatency..................................................................................................................C–9
FigureC5.SpectralEffici
encyvs.IdealEs/No@QEF............................................................................C–12
FigureC6.SpectralEfficiencyvs.ModemEs/No@QEF(PrunedModCods)........................................C–13
FigureC7.CDM750WebServerInterfaceConfiguration|Modempage........................................C–17
FigureC8.CDM750ACMCongestionControl...................................................................................C–19
FigureD1.Co
nceptualBlockDiagram.....................................................................................................D–3
FigureD2.ConventionalFDMALink........................................................................................................D–5
FigureD3.SameLinkUsingCDM750andDoubleTalk
CarrierinCarrier...............................................D–6
FigureD4.DuplexLinkOptimization.......................................................................................................D–6
FigureD5.DoubleTalkCarrierinCarrierSignals.....................................................................................D–8
FigureD6.CarrierinCarrierSignalProcessingBlockDiagram...............................................................D–9
FigureF1.NetworkingLoopwithSwitches.............................................................................................F–2
FigureF2.CDM750EthernetArchitectureDesign.................................................................................F–3
FigureF3.Im
properUseofExternalSwitchwithCDM750....................................................................F–4
FigureG1.CDM750DataFlowDiagram................................................................................................G–2
FigureH1.DVBS2QPSKPacketErrorRateversusEs/No.......................................................................H–3
FigureH2.DVBS28PSKPacketErrorRateversusEs/No........................................................................H–4
FigureH3.DV
BS216APSKPacketErrorRateversusEs/No....................................................................H–5
FigureH4.DVBS232APSKPacketErrorRateversusEs/No....................................................................H–6
xv
PREFACE
About this Manual
ThismanualprovidesinstallationandoperationinformationfortheComtechEFDataCDM750
Advanced HighSpeed Trunking Modem. This is an informational document intended for the
personsresponsiblefortheoperationandmaintenanceoftheCDM750.
Reporting Comments or Suggestions Concerning this Manual
ComtechEFDatawelcomescommentsandsuggestionsregardingthecontentanddesignofthis
manual.ContacttheComtechEFDataTechnicalPublicationsDepartment:
Conventions and References
Patents and Trademarks
SeeallofComtechEFData'sPatentsandPatentsPendingathttp://patents.comtechefdata.com.
ComtechEFDataacknowledgesthatalltrademarksarethepropertyofthetrademarkowners.
DoubleTalk
®
islicensedfrom"RaytheonAppliedSignalTechnology".
DoubleTalk
®
isaregisteredtrademarkof"RaytheonAppliedSignalTechnology".
CarrierinCarrier
®
isaregisteredtrademarkofComtechEFData.
Warnings, Cautions, and Notes
A WARNING
gives information about a possible hazard that MAY CAUSE DEATH
or SERIOUS INJURY.
A CAUTION
gives information about a possible hazard that MAY CAUSE INJURY
or PROPERTY DAMAGE.
CDM-750 Advanced Higuh-Speed Trunking Modem Revision 2
Preface MN-CDM750
xvi
A NOTE
gives important information about a task or the equipment.
A REFERENCE
directs the user to additional information about a task or the
equipment.
Examples of Multi-Hazard Notices
Recommended Standard Designations
Recommended Standard (RS) Designations are superseded by the new designation of the
Electronic I ndustries Association (EIA). References to the old designations may be shown when
depictingactualtext(e.g.,RS232)displayedontheWebServerpages,serialremoteinterface,or
unitrearpanel.Allother referencesinthemanualrefertoEI
Adesignations.
Metric Conversion
Metric conversion information is providedat the insidebackcover of this manual toassist the
operatorincrossreferencingnonMetrictoMetricconversions.

The user should carefully review the following information:
Safety and Compliance
Electrical Safety and Compliance
TheunitcomplieswiththeEN60950SafetyofInformationTechnologyEquipment(Including
ElectricalBusinessMachines)safetystandard.
IFTHEUNITISOPERATEDINAVEHICLEORMOVABLEINSTALLATION,MAKESURE
THEUNITISSTABLE.OTHERWISE,EN60950SAFETYISNOTGUARANTEED.
CDM-750 Advanced Higuh-Speed Trunking Modem Revision 2
Preface MN-CDM750
xvii
Electrical Installation
CONNECTTHEUNITTOAPOWERSYSTEM THATHASSEPARATEGROUND,LINEAND
NEUTRAL CONDUCTORS. DO NOT CONNECT THE UNIT WITHOUT A DIRECT
CONNECTIONTOGROUND.
Sect3.3CDM750GroundandPowerConnections
Operating Environment
DONOTOPERATETHEUNITINANYOFTHESEEXTREMEOPERATINGCONDITIONS:
AMBIENT TEMPERATURES LESS THAN C (32° F) OR MORE THAN 50° C
(122°F).
PRECIPITATION, CONDENSATION, OR HUMID ATMOSPHERES OF MORE
THAN95%RELATIVEHUMIDITY.
UNPRESSURIZEDALTITUDESOFMORETHAN2000METRES(6561.7FEET).
EXCESSIVEDUST.
FLAMMABLEGASES.
CORROSIVEOREXPLOSIVEATMOSPHERES.
European Union Radio Equipment and Telecommunications Terminal
Equipment (R&TTE) Directive (1999/5/EC) and EN 301 489-1
IndependenttestingverifiesthattheunitcomplieswiththeEuropeanUnionR&TTEDirective,its
reference to EN 301 4891 (Electromagnetic compatibility and Radio spectrum Matters [ERM];
ElectroMagnetic Compatibility [EMC] standard for radio equipment and services, Part 1:
Common technical requirements), and the Declarations of Conformity for the applicable
directives,standards,andpracti
cesthatfollow:
European Union Electromagnetic Compatibility (EMC) Directive
(2004/108/EC)
Emissions: EN 55022 Class B Limits and Methods of Measurement of Radio
InterferenceCharacteristicsofInformationTe chnologyEquipment.
Immunity: EN 55024 Information Technology Equipment: Immunity Characteristics,
Limits,andMethodsofMeasurement.
EN6100032HarmonicCurrentsEmission
CDM-750 Advanced Higuh-Speed Trunking Modem Revision 2
Preface MN-CDM750
xviii
EN6100033VoltageFluctuationsandFlicker.
FederalCommunicationsCommissionFederalCodeofRegulationFCCPart15,SubpartB.
TOENSURETHATTHEUNITCOMPLIESWITHTHESESTANDARDS,OBEYTHESE
INSTRUCTIONS:
Use coaxial cable that is of good quality for connections to the LBand Type ‘N’ Rx
(receive)femaleconnector.
UseType'D'connectorsthathavebackshellswithcontinuousmetallicshielding.
Type‘D’cablingmusthaveaconti
nuousoutershield(eitherfoilorbraid,orboth).The
shieldmustbebondedtothebackshell.
Operatetheunitwithitscoveronatalltimes.
European Union Low Voltage Directive (LVD) (2006/95/EC)
Symbol Description
<HAR> TypeofpowercordrequiredforuseintheEuropeanCommunity.
CAUTION:Doublepole/NeutralFusing
ACHTUNG: Zweipoligebzw.NeutralleiterSicherung

InternationalSymbols
Symbol Definition Symbol Definition
AlternatingCurrent ProtectiveEarth
Fuse
ChassisGround
Foradditionalsymbols,refertoWarnings,CautionsandNoteslistedearlierinthis
Preface.
European Union RoHS Directive (2002/95/EC)
Thisunitsatisfies(withexemptions)therequirem entsspecifiedintheEuropeanUnionDirective
on the Restriction of Hazardous Substances in Electrical and Electronic Equipment (EU RoHS,
Directive2002/95/EC).
!
CDM-750 Advanced Higuh-Speed Trunking Modem Revision 2
Preface MN-CDM750
xix
European Union Telecommunications Terminal Equipment Directive
(91/263/EEC)
In accordance with the European Union Telecommunications Terminal Equipment Directive
91/263/EEC, the unit should not be directly connected to the Public Telecommunications
Network.
CE Mark
ComtechEFDatadeclaresthattheunitmeetsthenecessaryrequirementsfortheCEMark.
Warranty Policy
ComtechEFDataproductsarewarrantedagainstdefectsinmaterialandworkmanship
for a specific period from the date of shipment, and this period varies by product.In
mostcases, the warrantyperiodis two years. Duringthewarrantyperiod, ComtechEF
Datawill,atitsoption,repairorreplaceproductsthatprovetobedefective.Repairsare
warranted for the remainder of the original warranty or a 90 day extended warranty,
whichever is longer. Contact Comtech EF Data for the warranty period specific to the
productpurchased.
Forequipmentunder warranty,the ownerisresponsible fo rfreight toComtechEF Data
andallrelatedcustoms,taxes,tariffs,insurance,etc.ComtechEFDataisresponsiblefor
the freight charges only for return of the equipment from the factory to the owner.
Comtech EF Data will return the equipment by the same method (i.e., Air, Express,
Surface)asthe equipmentwassenttoComt echEFData.
AllequipmentreturnedforwarrantyrepairmusthaveavalidRMAnumberissuedprior
to return and be marked clearly on the return packaging.Comtech EF Data strongly
recommendsallequipmentbereturnedinitsoriginalpackaging.
ComtechEFData Corporation’s obligationsunderthiswarrantyarelimitedtorepairor
replacement of failed parts, and the return shipment to the buyer of the repaired or
replacedparts.
Limitations of Warranty
The warranty does not applyto any part of a product that has beeninstalled, altered,
repaired, or misused in any way that, in the opinion of Comtech EF Data Corporation,
wouldaffectthereliabilityordetractsfromtheperformance ofanypartofthe product,
or is damaged as the result of use in a way or with equipment that had not been
previouslyapprovedbyComtechEFDataCorporation.
CDM-750 Advanced Higuh-Speed Trunking Modem Revision 2
Preface MN-CDM750
xx
Thewarrantydoesnotapplytoanyproductorpartsth ereof wheretheserialnumberor th e
serialnumberofan yofitspartshasbeenal tered,defaced,orremoved.
Thewarrantydoesnotcoverdamageorlossincurredintransportationoftheproduct.The
warrantydoesnotcoverreplacementorrepairnecessitatedbylossordamagefromany
cause beyond the control of Comtech EF Data Corporation, such as lightning or other
naturalandweatherrelatedeventsorwartimeenvironments.
Thewarrantydoesnot coverany laborinvolved in the removalandor reinstallation of
warrantedequipment orparts on site,or anylabor requiredto diagnosethe necessity
forrepairorreplacement.
ThewarrantyexcludesanyresponsibilitybyComtechEFDataCorporationforincidentalor
consequential damages arising from the use of the equipment or products, or for any
inabilitytousethemeitherseparatefromorincombinationwithanyotherequipmentor
products.
Afixedchargeestablishedforeachproductwillbeimposedforallequipment returned
forwarrantyrepairwhereComtechEFDataCorporationcannotidentifythecauseofthe
reportedfailure.
Exclusive Remedies
Comtech EF Data Corporation’s warr anty , as stated is in lieu of all othe r warranties,
expressed, implied, or sta tut ory, including those of merchantability and fitness for a
particularpur pose .Thebuyershallpassontoanypurchaser,lessee ,orother userof
Comtech EF Data Corporation’s products, the aforementioned warran ty, and shall
indemnifyandhold harmle ssComtechEFDataCorporationfromanyclaimsorliability
ofsuchpurchaser,lessee ,oruserbaseduponallegationsthatthebuyer,itsagents,or
employees have made additional warranties or representations as to product
preferenceoruse.
Theremediesprovidedhereinarethebuyer’ssoleandexclusiveremedies.ComtechEF
Data shall not be liable for any direct, indirect, special, incidental, or consequential
damages,whetherbasedoncontract,tort,oranyotherlegaltheory.
/