1 TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1.1 Explanation for the lists
1 TROUBLESHOOTING FOR SERVO AMPLIFIER
(DRIVE UNIT)
• As soon as an alarm occurs, turn SON (Servo-on) off and interrupt the power.
• [AL. 37 Parameter error] and warnings (except [AL. F0 Tough drive warning]) are not recorded in the alarm
history.
• [AL. 8D.1 CC-Link IE communication error 1] and [AL. 8D.2 CC-Link IE communication error 2] are not
recorded in the alarm history. For MR-J4-_GF_(-RJ), these alarms are recorded by setting [Pr. PN06] to "_ _
_ 1".
When an error occurs during operation, the corresponding alarm or warning is displayed.
When an alarm occurs, ALM will turn off. Refer to the following and take the appropriate action.
Page 28 Remedies for alarms
When an warning is displayed, refer to the following and take the appropriate action.
Page 101 Remedies for warnings
1.1 Explanation for the lists
No./Name/Detail No./Detail name
Indicates each No./Name/Detail No./Detail name of alarms or warnings.
Stop method
For the alarms and warnings in which "SD" is written in the stop method column, the servo motor stops with the dynamic
brake after forced stop deceleration. For the alarms and warnings in which "DB" or "EDB" is written in the stop method
column, the servo motor stops with the dynamic brake without forced stop deceleration.
Alarm deactivation
After its cause has been removed, the alarm can be deactivated in any of the methods marked in the alarm deactivation
column. Warnings are automatically canceled after the cause of occurrence is removed. Alarms are deactivated with alarm
reset, CPU reset, or cycling the power.
■MR-J4-_A_(-RJ)/MR-J4-DU_A_(-RJ)
■MR-J4-_B_(-RJ010)/MR-J4W_-_B/MR-J4-DU_B_(-RJ)/MR-J4-_GF_(-RJ)
Processing system (only for MR-J4W_-_B_)
Processing system of alarms is as follows.
Each axis: Alarm is detected for each axis.
Common: Alarm is detected as the whole servo amplifier.
Alarm deactivation Explanation
Alarm reset 1. Turning on RES (Reset) with input device
2. Pushing the "SET" button while the display of the servo amplifier is the current alarm display status
3. Click "Occurring Alarm Reset" in the "Alarm Display" window of MR Configurator2
Cycling the power Turning the power off and then turning it on again.
Alarm deactivation Explanation
Alarm reset 1. Reset command from controller
2. Click "Occurring Alarm Reset" in the "Alarm Display" window of MR Configurator2
CPU reset Resetting the controller itself
Cycling the power Turning the power off and then turning it on again.