Eaton E71 Operating instructions

Type
Operating instructions
Electric current! Danger to life!
Only skilled or instructed persons may
carry out the following operations.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate.
只允许专业人员和受过专业训练的人员进行
下列工作。
Электрический ток! Опасно для жизни!
Только специалисты или проинструктированные
лица могут выполнять следующие операции.
تتــــــــ!!ــــررــــ!!ــــ!!
ﺐـــــﻴﻛﺮﺘﻟا و ﺔﻧﺎﻴـــــﺼﻟا لﺎـــــﻤﻋا ﻢـــــﺘﺗ ﻻ
ﻦﻴﺑرﺪــــﻤﻟا ﻦﻴﻠﻣﺎــــﻌﻟا ﻞــــﺒﻗ ﻦــــﻣ ﻻا !
en
de
fr
es
it
zh
ru
ar
03/22 IL05305006Z (P52080)
Instruction Leaflet
Montageanweisung
Notice d’installation
Instrucciones de montaje
Istruzioni per il montaggio
Инструкция по монтажу
تتــــــــــااررــــــــــ
1/2
Instruction Leaflet IL05305006Z (P52080) Effective March 2022
Supersedes May 2018 E71 Series
NanoView Optical Sensors
E71…
Dimensions
aSensitivity Dial
bStability LED
cPower On LED
dOutput LED
E71-P/S/C
4.2 mm
(0.17")
4 mm
(0.16")
24 mm
(0.94")
32 mm
(1.26")
5 mm
(0.20")
2.6 mm
(0.10")
3.2 mm
(0.13")
10.7 mm
(0.42")
20 mm
(0.79")
② ③
3.7 mm
(0.15")
12 mm
(0.47")
E71-P/S/C
4.2 mm
(0.17")
4 mm
(0.16")
24 mm
(0.94")
32 mm
(1.26")
3.8 mm
(0.15")
2.6 mm
(0.10")
3.2 mm
(0.13")
10.7 mm
(0.42")
20 mm
(0.79")
② ③
M8
12 mm
(0.47")
03/22 IL05305006Z (P52080)
USA:
Eaton.com/eatoncare
+1 877-386-2273
Eaton.com/sensors
+1 800-426-9184
Eaton.com/contacts
Eaton.com/aftersales
Eaton.com/documentation
USA: Eaton Corporation, W126 N7250 Flint Drive, Menomonee Falls, WI 53051, USA Publication No.
IL05305006Z (P52080) March 2022
EU: Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany
UK: Eaton Electric Ltd., P.O. Box 554, Abbey Park, Southampton Road, Titchfield, PO14 4QA, UK
Eaton.com/recycling
2/2 © 2012 Eaton Corporation
Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.
Wiring diagrams
Initial Setup
NPN PNP
1) Light Output is on BK wire/Pin 4 for Diffuse sensors and on WH wire/Pin 2 for Retroreflective and thru-beam sensors.
For E71-P/C (polarized retroreflective and clear object) models…
Position sensor and reflector on opposite sides.
Turn the sensitivity dial to maximum.
Find the point at which the output LED (yellow) is switched on, then find the point where the output LED (yellow)
is switched off, then aim the sensor in the center between these two points.
To further improve alignment, repeat this process while progressively reducing the sensitivity.
At the conclusion of the process, return the sensitivity to maximum.
Optimum sensing reliability is obtained when the green LED is on (for polarized refl ex models).
For Clear Object detection of transparent or very small targets, reduce the sensitivity dial position until the sensor
successfully detects the target material.
For E71-T/N (thru-beam source and receiver) models…
Position the source and receiver sensor on opposite sides.
Find the point at which the output LED (yellow) is switched on, then find the point where the output LED (yellow)
is switched off, then aim the sensor in the center between these two points.
Optimum sensing reliability is obtained when the green LED is on.
For E71-S (diffuse refl ective) models…
Position the sensor and turn the sensitivity dial to minimum.
The green LED should be on, the yellow LED should be off.
Place the target opposite the sensor.
Turn the sensitivity dial clockwise until the yellow LED turns on (target detected state).
Remove the target and the yellow LED should turn off.
Turn the sensitivity dial clockwise until the yellow LED turns on (background detected state).
Turn the sensitivity dial to an intermediate position between target detected state and background detected state.
The green LED must be on.
For E71-F (fixed focus) models…
The operating distance of these sensors is factory set at 11 cm ± 10 %
To improve detection, move the target closer or further away from the sensor, or move the target perpendicular
to the sensor body (as pictured).
2
4
1
3
0 V
+V
0 V
+V
DK. OP.1)
LT. OP.1) Load Load 2
4
1
3
0 V
+V
0 V
+V
DK. OP.1)
LT. OP.1) Load Load
DIN IEC 304, DIN IEC 757
BK 0
BN 1
BU 6
WH 9
BN
WH
BK
BU 0 V
+V
DK. OP.1)
LT. OP.1)
Load
Load
BN
WH
BK
BU 0 V
+V
DK. OP.1)
LT. OP.1)
Load
Load
  • Page 1 1
  • Page 2 2

Eaton E71 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI