Eaton E75 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Eaton E75 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Electric current! Danger to life!
Only skilled or instructed persons may
carry out the following operations.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate.
只允许专业人员和受过专业训练的人员进行
下列工作。
Электрический ток! Опасно для жизни!
Только специалисты или проинструктированные
лица могут выполнять следующие операции.
تتــــــــ!!ــــررــــ!!ــــ!!
ﺐـــــﻴﻛﺮﺘﻟا و ﺔﻧﺎﻴـــــﺼﻟا لﺎـــــﻤﻋا ﻢـــــﺘﺗ ﻻ
ﻦﻴﺑرﺪــــﻤﻟا ﻦﻴﻠﻣﺎــــﻌﻟا ﻞــــﺒﻗ ﻦــــﻣ ﻻا !
en
de
fr
es
it
zh
ru
ar
03/22 IL05305007Z (P51998)
Instruction Leaflet
Montageanweisung
Notice d’installation
Instrucciones de montaje
Istruzioni per il montaggio
Инструкция по монтажу
تتــــــــــااررــــــــــ
1/2
Instruction Leaflet IL05305007Z (P51998) Effective March 2022
Supersedes May 2018 E75 Series
IntelliView Optical Sensors with
adjustable Backround rejection
E75…
Dimensions
aOutput LED
bStability LED
cRange Adjustment Dial
27 mm
(1.06")
① ②
No. 2 4.6 mm
No. 2 (0.18")
12 mm
(0.47")
40 mm (1.57")
5 mm
(0.2")
5 mm
(0.2")
50 mm (1.97")
40 mm (1.57")5 mm
(0.2")
5 mm
(0.2")
50 mm (1.97")
7mm
(0.28")
15 mm
(0.59")
M12
18 mm
(0.71")
2 mm
(0.08")
18 mm x 45º
(0.71" x 45º)
0.75 mm
(0.03")
11 mm
(0.43")
14 mm
(0.55")
6 mm
(0.24")
42 mm (1.65")
50 mm (1.97") 1.1 mm
(0.04")
42 mm (1.65") 4.7 mm
(0.19")
50 mm (1.97")
M12
16 mm
(0.63") 15.5mm
(0.61")
18.2 mm
(0.72")
15 mm
(0.59")
18 mm
(0.71")
10.7 mm
(0.42")
18.4 mm
(0.72")
6.18 mm
(0.24")
11 mm
(0.43")
03/22 IL05305007Z (P51998)
USA:
Eaton.com/eatoncare
+1 877-386-2273
Eaton.com/sensors
+1 800-426-9184
Eaton.com/contacts
Eaton.com/aftersales
Eaton.com/documentation
USA: Eaton Corporation, W126 N7250 Flint Drive, Menomonee Falls, WI 53051, USA Publication No.
IL05305007Z (P51998) March 2022
EU: Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany
UK: Eaton Electric Ltd., P.O. Box 554, Abbey Park, Southampton Road, Titchfield, PO14 4QA, UK
Eaton.com/recycling
2/2 © 2012 Eaton Corporation
Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.
Wiring diagrams
Controls and adjustment
Initial Setup
→ EN 60947-5-2
Red LED Indicates output status
Green LED Indicates strong signal (greater than 30 % detection margin)
Range adjustment dial This control can be used to adjust the foreground and/or background suppression distance.
E75-PPA010P-M12…
Position the sensor aimed at the background.
Move the sensor closer to the background until the red output LED turns off (move away if the output LED is on).
The sensor is now ready to detect any object inside the operating range (output LED turns on).
E75-PPA025P-M12, E75-PPA050P-M12…, E75-PP1MP-M12
Position the sensor aimed at the background.
Turn the range adjustment dial counter-clockwise until the red/yellow LED turns off and the green stability LED turns on.
During this phase, it is important to not move the background and/or the sensor.
Place the object in the detection area and verify the green stability LED turns on and the switching has occurred.
E75-PPA110P-M12…
Place the target opposite the sensor.
Turn the range adjustment dial counter-clockwise, until the red output LED turns off and the green stability LED turns on.
Turn the range adjustment dial clockwise until the red output LED and green stability LED turns on.
The red output LED has to turn off when target is moved closer to the sensor (foreground suppression area).
24
1
3
BN
WH BK
BU
0 V 0 V
+V +V
DK. OP. LT. OP.
Load Load
→ DIN IEC 304, DIN IEC 757
BK 0
BN 1
BU 6
WH 9
/