luminii Kendo S Recessed Installation guide

Type
Installation guide

This manual is also suitable for

Kendo RS, RM, RL & RXL - Installation Instructions
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. WALL MOUNT ONLY
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Page 1 of 3
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.6 03052019
Models KRS-XX, KRM-XX, KRL-XX, & KRXL-XX
NOTE: The fixtures can be installed in various mounting materials. As long as the recessed depth is considered as shown below. These
light fixtures can be installed in a up or down position. Reference specific model for accurate dimensions.
1
0.36”
1.01”
0.69”
0.46”
0.36” 0.44”
0.88”
1.01”
0.69”
1.40”
0.55” 0.63”
1.04”
1.01”
0.69”
0.55”
0.63”
Kendo RS
hard surface mounting
bracket, such as wood,
stone, tile
1.40”
1.1
Kendo RS
soft surface mounting
bracket,such as drywall,
plaster
6. SUITABLE FOR INSTALLATION WITHIN THE
CLOSET STORAGE SPACE
7. TYPE IC (CEILING & WALL)
8. SUITABLE FOR GROUND MOUNTED-RECESSED,
ACCESS ABOVE CEILING REQUIRED
0.36”
1.21”
0.83”
0.46”
0.36” 0.44”
0.88”
0.83”
1.40”
1.1
1.21”
0.55” 0.63”
1.04”
1.40”
0.55” 0.63”
0.83”
1.21”
Kendo RM
hard surface mounting
bracket, such as wood,
stone, tile
Kendo RM
soft surface mounting
bracket,such as drywall,
plaster
Kendo RL
hard surface mounting
bracket, such as wood,
stone, tile
Kendo RL
soft surface mounting
bracket,such as drywall,
plaster
Kendo RXL
hard surface mounting
bracket, such as wood,
stone, tile
Kendo RXL
soft surface mounting
bracket,such as drywall,
plaster
0.81”
0.81”
1.01”
0.69”
0.81” 0.81”
0.96”
0.96”
0.96”
0.83”
1.21”
0.96”
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Page 2 of 3
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. WALL MOUNT ONLY
6. SUITABLE FOR INSTALLATION WITHIN THE
CLOSET STORAGE SPACE
7. TYPE IC (CEILING & WALL)
8. SUITABLE FOR GROUND MOUNTED-RECESSED,
ACCESS ABOVE CEILING REQUIRED
2.1 Route slots onto the surface with the proper width and depth to
accommodate aluminum extrusion. Use drawing above as
reference.
router
surface
2
2.1
33.1 Prior to installing the fixture, For mounting bracket options only:
slide the mounting brackets on the back of the fixture. To evenly
distribute the weight of the fixture.
soft surface mounting bracket,
such as drywall, plaster
hard surface mounting bracket,
such as wood, stone, tile
4”
every 48”
4”
every 48”
bracket
bracket
TOP
VIEW
FRONT
VIEW
Kendo RS, RM, RL & RXL - Installation Instructions
Models KRS-XX, KRM-XX, KRL-XX, & KRXL-XX
REV0.6 03052019
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Page 3 of 3
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
4
HS mounting:
Hard surface
mounting bracket
NB mounting
No bracket
mounting
GS mounting
Gypsum surface
mounting bracket
4.1 Align the mounting brackets to the cutout slot, then carefully push the fixture completely inside to the slot to secure.For hard surface mounting bracket option:
NOTE: Fixture wires must be considered, prior to installing. Reference wiring diagram for additional information on step 5.
NOTE: Follow one of the three mounting options, to properly install fixture.
4.2 Bend the adjustable springs to a straight position, followed by pushing the fixture completely inside the cutout For soft surface mounting bracket option:
slot. Then release the springs to secure.
fixture
mounting bracket
slot slot
4.1 4.1
fixture
mounting bracket
slot
4.3 Apply construction adhesive to the bottom of the cutout slot, then place fixture onto adhesive to secure.For no mounting bracket option:
fixture
construction adhesive
4.2 4.2
4.3 4.3
5
line voltage wires low voltage wires
class II power
supply
fixture wires
5.3
5.1 Ensure the correct (wattage & voltage) power supply is used to power
the fixture. Then proceed to connect the fixture wires from fixture to the
power supply. For more information please refer to power supply wiring
instructions.
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. WALL MOUNT ONLY
6. SUITABLE FOR INSTALLATION WITHIN THE
CLOSET STORAGE SPACE
7. TYPE IC (CEILING & WALL)
8. SUITABLE FOR GROUND MOUNTED-RECESSED,
ACCESS ABOVE CEILING REQUIRED
Kendo RS, RM, RL & RXL - Installation Instructions
Models KRS-XX, KRM-XX, KRL-XX, & KRXL-XX
REV0.6 03052019
  • Page 1 1
  • Page 2 2
  • Page 3 3

luminii Kendo S Recessed Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI