ACTi R11C-30 Quick Installation guide

Type
Installation guide
Readers & Controllers
Quick Installation Guide
R11C-30
2020/03/23
www.acti.com
Quick Installation Guide
2
Table of Contents
Part 1: Installation and Wiring ............................... 3
Installation ................................................................................................ 3
Cabling Instructions ................................................................................. 4
Connectors Diagram ............................................................................. 4
Wiring Instructions ................................................................................ 6
Part 2: Basic Settings ............................................. 8
Step 1: Go to SETTINGS .......................................................................... 8
Step 2: Set the Language ........................................................................ 9
Step 3: Change Password ...................................................................... 11
Part 3: Other Configurations ................................ 12
Configure IP Address ............................................................................. 12
Configure RELAY ................................................................................... 16
Restore to Default Factory Settings ..................................................... 18
www.acti.com
Quick Installation Guide
3
Thank you for using ACTi Reader. This documentation contains basic settings of
your device. If you wish to add users, it is recommended to add users through the
Access Control Standard Server (ACSS). For more information, please refer to
the ACSS manual.
Part 1: Installation and Wiring
Installation
Attach the waterproof strip to the mounting plate.
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the
mounting plate.
Assemble the covers with the bundled Allen key and scres.
Turn on the power, the LED will light and a beep will sound, you will see
Ready” on the LCD screen.
www.acti.com
Quick Installation Guide
4
Cabling Instructions
Connectors Diagram
Cable: CN4 (Main cable)
Wire Application
Wire
Color
Description
Lock Relay
1
Blue - White
Normal On (N.O.)
2
Purple White
Normal Close (N.C.)
Lock Relay COM
3
White
COM
Door Contact
4
Orange
Negative Trigger Input
Exit Switch
5
Purple
Negative Trigger Input
Alarm Relay
6
Gray
DC24V1Amp
Power
7
Red
DC 12V
8
Black
DC 0V
www.acti.com
Quick Installation Guide
5
Cable: CN5 (Wiegand DI/DO Wiring)
Wire Application
Wire
Color
Description
Beeper
1
Pink
Beeper Output 5V/100mA,
Low
LED
2
Yellow
Red LED Output 5V/20mA,
Max
3
Brown
Green LED Output 5V/20mA,
Max
Door Output
4
Blue White
Transistor Output Max.
12V/100mA
(Open collector Active Low)
Wiegand
5
Green
Wiegand DAT: 0 Input
6
Blue
Wiegand DATA: 1 Input
WG Door
Contact
7
Orange
Negative Trigger Input
WG Door Switch
8
Purple
Negative Trigger Input
Cable: CN7 (Network Wiring)
Wire Application
Wire
Color
Description
1
---
---
2
---
---
TCP/IP Output
3
Orange-White
Net - TX+
4
Orange
Net - TX-
5
Green - White
Net - RX+
6
Green
Net - RX-
7
---
---
www.acti.com
Quick Installation Guide
6
Wiring Instructions
A. Connecting the Reader / Controller and Exit Switch
+
EXIT
GND
N.O.
+
-
E
-
+
Exit PB
0V
12V
DC 12V
DC 0V
Electric Lock
CN4
1
2
3
4
5
6
7
8
N.O.
COM
12V
0V (GND) )
PB
R11C-30
DC 12V
DC 0V
-
www.acti.com
Quick Installation Guide
7
B. Controlling Entry / Exit of Two or More Readers / Controllers
1
2
3
4
5
6
7
8
N.O.
COM
12V
0V(GND)
PB
+
-
E
-
+
Exit PB
0V
12V
DC 12V
DC 0V
Electric Lock
CN4
1
2
3
4
5
6
7
8
N.O.
COM
12V
0V (GND)
PB
R11C-30
DC 12V
DC 0V
-
+
-
+
DC 12V
DC 0V
R11C-30
www.acti.com
Quick Installation Guide
8
Part 2: Basic Settings
Step 1: Go to SETTINGS
Press “*123456# to enter the device SETTINGS.
Use the F1 , F2 keys to scroll up or down.
Use the * key to select an item and # key to enter menu.
Press
*
to select item.
Pressor #
Press F1 and F2 keys to
scroll up or down
Press # to enter.
www.acti.com
Quick Installation Guide
9
Step 2: Set the Language
1. In SETTINGS, select “5. Tools“ then press # to enter the menu.
2. Select “1. Language”.
3. Enter the corresponding number of the preferred language. A confirmation
message will appear. Press * to exit the menu.
www.acti.com
Quick Installation Guide
10
4. Select “Quit” to exit SETTINGS and return to the Standby screen.
www.acti.com
Quick Installation Guide
11
Step 3: Change Password
1. Go to SETTINGS and select “5. Tools”.
2. Select “ 2. Master Code”.
3. Enter the new password and then press # to confirm.
www.acti.com
Quick Installation Guide
12
Part 3: Other Configurations
Configure IP Address
1. Go to SETTINGS, select “3. Parameters (1)”.
2. Select 1. Node ID”.
www.acti.com
Quick Installation Guide
13
3. Retain the preset value (default value is 1), press # to confirm.
4. Retain the preset value of the Main Door Controller (default value is 1),
press # to confirm.
5. Retain the preset value of Weigand 1 WG1 (default value is 1), press # to
confirm.
6. The LCD display shows a confirmation message, set to “1” to enable
www.acti.com
Quick Installation Guide
14
weigand, then press # to confirm.
7. Set the device IP.
To Enable DHCP
To enable DHCP, select “1. Enable. When done, the device will
automatically restart and apply the setting.
To Disable DHCP
a. If DHCP will not be used, enter a static IP address, then press # to
confirm.
www.acti.com
Quick Installation Guide
15
b. Enter the Subnet Mask, press # to confirm.
c. Enter the Gateway, then press # to confirm.
When done, the device will automatically restart and apply the setting.
www.acti.com
Quick Installation Guide
16
Configure RELAY
You can set the relay interval when a door opens and closes on the device.
1. Go to SETTINGS, select “3. Parameters (1)”.
2. Select “3. Door Relay Tm”.
3. Set the time interval, then press # to confirm.
www.acti.com
Quick Installation Guide
17
4. If using a Wiegand control electric lock, you need to set the relay of the
Wiegand. Press # to confirm.
www.acti.com
Quick Installation Guide
18
Restore to Default Factory Settings
If necessary, you can restore the device default factory settings.
1. Go to SETTINGS, select “4. Parameters (2)”.
2. Select “9. Factory Reset”.
3. Select the corresponding number of the item to reset. You can reset either
the System settings or User settings or both. The device will automatically
restart after confirmation.
Copyright © 2020, ACTi Corporation All Rights Reserved
7F, No. 1, Alley 20, Lane 407, Sec. 2, Ti-Ding Blvd., Neihu District, Taipei, Taiwan 114, R.O.C.
TEL : +886-2-2656-2588 FAX : +886-2-2656-2599
Email: sales@acti.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

ACTi R11C-30 Quick Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI