Application & Device Safety Considerations
 Reading these Instructions
Before operating a device or application, read these instructions carefully and understand their safety implications. In some
situations, improper use may result in damage or injury. Keep this manual in a convenient location for future reference. Note
that these instructions may not cover all details or variations in equipment or cover every possible situation regarding
installation, operation, or maintenance. Should problems arise that are not covered sufficiently in the text, immediately contact
Customer Support for further information.
 Protecting Operating Processes
The failure of a device or application – for whatever reason – may leave an operating process without appropriate protection and
could result in possible damage to property or injury to persons. To protect against this, review the need for additional backup
equipment or provide alternate means of protection (such as alarm devices, output limiting, fail-safe valves, relief valves,
emergency shutoffs, emergency switches, etc.). Contact Energy and Transportation Automation Solutions for additional
information.
 Using Qualified Personnel
Installation, configuration, and any subsequent modifications to a device or application should only be performed by qualified,
suitably trained personnel information.
 System Training
A well-trained workforce is critical to the success of your operation. Knowing how to correctly install, configure, program,
calibrate, and trouble-shoot your Emerson equipment provides your engineers and technicians with the skills and confidence to
optimize your investment. Energy and Transportation Solutions offers a variety of ways for your personnel to acquire essential
system expertise. Our full-time professional instructors can conduct classroom training at several of our corporate offices, at
your site, or even at your regional Emerson office. You can also receive the same quality training via our live, interactive Emerson
Virtual Classroom and save on travel costs. For our complete schedule and further information, contact the Energy and
Transportation Solutions Training Department at 800-338-8158 or email us at education@emerson.com.
 Grounding Equipment
Refer to Emerson Machine Automation Solutions product documentation for further information.
 Protecting from Electrostatic Discharge (ESD)
Refer to Emerson Machine Automation Solutions product documentation for further information.
 Ethernet Connectivity
This automation device is intended to be used in an Ethernet network which does not have public access. The inclusion of this
device in a publicly accessible Ethernet-based network is not recommended.
 Returning Equipment
If you need to return any equipment to Energy and Transportation Solutions (ETS), it is your responsibility to ensure that the
equipment has been cleaned to safe levels, as defined and/or determined by applicable federal, state and/or local law
regulations or codes. You also agree to indemnify ETS and hold ETS harmless from any liability or damage which ETS may incur or
suffer due to your failure to ensure device cleanliness.
Emerson FBxEdge User Guide
D301913X012
October 2023
Contents iii
Contents
Chapter 1. Introduction 1
Chapter 2. Installing the FBxEdge Device 3
2.1 Unpacking and Inspecting ................................................................................................................... 3
2.1.1 Package Contents ..................................................................................................................... 3
2.2 Power Requirements ............................................................................................................................ 4
2.3 Ports ........................................................................................................................................................ 4
2.3.1 DP Display Port ......................................................................................................................... 4
2.3.2 USB3.2 Gen1 and USB2 Ports ................................................................................................. 5
2.3.3 Ethernet Ports ........................................................................................................................... 5
2.3.3.1 Ethernet Port LEDs ..................................................................................................... 5
2.3.4 Serial Ports ................................................................................................................................ 6
2.3.5 Audio Jacks ................................................................................................................................ 7
2.4 Coin Cell Battery .................................................................................................................................... 7
2.5 Mounting the RXi2 LP Edge Device .................................................................................................... 8
Chapter 3. Configuring the Edge Device 9
3.1 Acquiring an IP Address ....................................................................................................................... 9
3.1.1 IP Address Assigned by DHCP Server .................................................................................... 9
3.1.2 IP Address Assigned Manually ............................................................................................. 10
3.1.2.1 Setting the Static IP Address ................................................................................... 13
3.2 Accessing FBxEdge ............................................................................................................................. 17
3.2.1 Useful Links ............................................................................................................................. 19
3.2.2 Setting the Timezone ............................................................................................................. 21
3.3 Adding a ROC Device .......................................................................................................................... 23
3.4 Adding Tags ......................................................................................................................................... 27
3.4.1 Adding a Tag ........................................................................................................................... 28
3.4.2 Adding a Group of Tags ......................................................................................................... 32
3.4.2.1 Creating the CSV File ................................................................................................ 32
3.4.2.2 Uploading the CSV File ............................................................................................. 32
3.4.2.3 Browse the Available Tags ...................................................................................... 34
3.5 Defining the Status Register ............................................................................................................. 35
3.6 Setting Up Flows Manager ................................................................................................................ 37
3.6.1 Subscribing to the Datahub .................................................................................................. 38
3.6.2 Configuring a Flow ................................................................................................................. 41
3.7 Adding an MQTT Connector .............................................................................................................. 42
3.7.1 Adding an MQTT Connector ................................................................................................. 42
3.7.2 Adding an MQTT Connector (for Sparkplug.B Messages) ............................................... 47
3.8 Mapping Tags to an MQTT Connector ............................................................................................. 48
3.8.1 Using Wildcards ...................................................................................................................... 49
Emerson FBxEdge User Guide
D301913X012
October 2023
iv Contents
Chapter 4. System Reference 51
4.1 Info ....................................................................................................................................................... 53
4.2 Certificates ........................................................................................................................................... 55
4.3 Network ............................................................................................................................................... 56
4.4 Wi-Fi ...................................................................................................................................................... 57
4.5 Remote Access .................................................................................................................................... 57
4.6 Device Management .......................................................................................................................... 57
4.7 LDAP/AD Authorization ..................................................................................................................... 58
4.8 Users..................................................................................................................................................... 58
4.9 Tokens .................................................................................................................................................. 58
4.10 Services ................................................................................................................................................ 58
4.10.1 FTP ............................................................................................................................................ 58
4.10.2 Secure Socket Shell (SSH) ..................................................................................................... 60
4.10.3 Remote Access ....................................................................................................................... 60
4.11 External Storage ................................................................................................................................. 61
4.12 Policy Management ........................................................................................................................... 61
4.13 License ................................................................................................................................................. 62
4.14 Events ................................................................................................................................................... 63
4.15 Support ................................................................................................................................................ 64
4.16 Backup/Restore .................................................................................................................................. 64
4.16.1 Backup/Restore Tab .............................................................................................................. 64
4.16.1.1 What Is Backed Up ................................................................................................... 64
4.16.1.2 Before Beginning ..................................................................................................... 65
4.16.1.3 Best Practices ............................................................................................................ 65
4.16.1.4 Successful Backup .................................................................................................... 65
4.16.2 Template Tab .......................................................................................................................... 66
Appendix A. Installing the RXi2-BP Gateway A-1
A.1 Unpacking and Inspecting ............................................................................................................... A-1
A.1.1 Package Contents ................................................................................................................. A-1
A.2 Power Requirements ........................................................................................................................ A-2
A.3 LEDs ..................................................................................................................................................... A-2
A.4 Ports .................................................................................................................................................... A-3
A.4.1 Ethernet Ports ....................................................................................................................... A-3
A.4.1.1 Ethernet Port LEDs ................................................................................................. A-4
A.4.2 Display Port ........................................................................................................................... A-4
A.4.3 USB3.2 Gen1 and USB2 Ports.............................................................................................. A-5
A.4.4 Serial Ports ............................................................................................................................. A-6
A.4.5 microSD Slot .......................................................................................................................... A-7
A.5 Mounting the Gateway ..................................................................................................................... A-8
A.5.1 Required Clearances ............................................................................................................ A-8
A.5.2 DIN Rail Mounting ................................................................................................................ A-9
A.5.3 Panel Mounting................................................................................................................... A-10
Emerson FBxEdge User Guide
D301913X012
October 2023
Contents v
Emerson FBxEdge User Guide
D301913X012
October 2023
1
Chapter 1. Introduction
This guide provides a quick introduction to the Emerson FBxEdgeâ„¢ solution, which
consists of an edge device (either the Emerson RXi2 – LP Industrial PC or the Emerson
RXi2 – BP Industrial PC) connecting to one or more Emerson FB3000 RTUs, Emerson
FB1000 or FB2000 series flow computers, or Emerson ROC800 RTUs. This guide covers the
installation of the physical edge device and details the process you use to link field
devices to that FBxEdge device.
Note
Using FBxEdge, you can create a network of field devices linked into a single edge device.
You can then use the FBxEdge Managerâ„¢ web-based software to connect multiple
FBxEdge devices into larger network. For more information on FBxEdge Manager, refer to
the Emerson FBxEdge Manager User Guide (part D301916X012).
Figure 1-1. The FBxEdge Environment
Emerson FBxEdge User Guide
D301913X012
October 2023
2
FBxEdge is a keystone component in an integrated combination of controllers, software,
and IIoT solutions.
You can connect an unlimited number of devices and map an unlimited number of tags to
an individual FBxEdge device. The edge device provides drivers for a multitude of devices
and protocols, including DNP3 and ROC Plus.
Emerson FBxEdge User Guide
D301913X012
October 2023
3
Chapter 2. Installing the FBxEdge Device
Important
Emerson offers two edge devices as part of the FBxEdge solution: the default RXi2-LP and
the optional RXi2-BP. Consult with your Emerson Impact Partner to determine which edge
device best meets your organization’s needs. This section discusses the installation of the
RXi2-LP edge device. Refer to Appendix A for installation processes for the RXi2-BP edge
device.
The RXi2-LP uses an AMD® G-Series Quad Core 1.2GHz processor, with 4Gb of RAM and
65Gb of storage. For further specifications, refer to the FBxEdge Platform product data
sheet (D301940X012). When delivered from the factory, the FBxEdge software is pre-
installed on the RXi2-LP edge device. You are responsible for installing the edge device in
a suitable location.
Figure 2-1. RXi2-LP Industrial PC (Rear View)
2.1 Unpacking and Inspecting
WARNING
If the RXi2-LP edge device operates in an area of high ambient temperature up to 65 °C
(149 F°), the surface of the enclosure, especially the heat sink, can reach a temperature
of 80 °C (176 °F) and above. Be careful and do not touch the RXi2-LP with bare fingers.
2.1.1 Package Contents
Verify that the delivered package contains the following contents:
Item Quantity Description
RXi2-LP IPC 1 RXi2-LP Industrial PC
Serial Connector Plug 2 Serial Connector Plug
24V Power-in Connector Plug 1 Power Connector Ring
Emerson FBxEdge User Guide 1 User manual for device (part
D301913X012)
Emerson FBxEdge User Guide
D301913X012
October 2023
4
2.2 Power Requirements
The RXi2-LP requires a DC power supply with 24V (± 20%) that delivers at least 1.8A. The
corresponding plug is a Phoenix Contact 1748367. Use the same connector type or its
equivalent.
Note
Once you have connected power, use the power button (on the left side of the device) to
power up the edge device. The LED status indicator is solid amber as the unit starts up
and switches to solid green during normal operation.
Figure 2-2. Power Connector
Signal Name Pin (left to right)
FGND 2
Power – (24V DC)
2
Power + (24V DC) 1
2.3 Ports
The RXi2-LP provides several ports you can use to connect devices.
Figure 2-3. Connection Ports on RXi2 LP
2.3.1 DP Display Port
The RXi2-LP provides one digital display interface (located between the power connector
and two USB ports). It transmits audio and video simultaneously. Use the port to directly
connect a monitor with a DP input or use standard off-the-shelf adapters to convert the
DP signals to HDMI or VGA.
Figure 2-4. DP Display Port
Emerson FBxEdge User Guide
D301913X012
October 2023
5
2.3.2 USB3.2 Gen1 and USB2 Ports
The RXi2-LP provides four USB ports, all using Type A connectors. Two (which support
USB 3.2 Gen1) are located between the DP port and a pair of Ethernet ports. Two
additional USB ports (which support USB2) are located to the left of a second pair of
Ethernet ports. Each USB port is protected with an electrical fuse rated up to 1A. For
normal operation, do not exceed 900mA for USB 3.2 Gen1 or 500mA for USB2. Limit cable
length to no more than 3m.
Figure 2-5. USB Ports (3.2 and 2)
2.3.3 Ethernet Ports
The RXi2-LP provides four Ethernet ports: two to the left of the serial connections and two
to the right of the pair of USB 2x ports. All ports support 10/100/1000 Base-T. For a proper
100/1000 Mbit connection, Emerson recommends using a CAT5 cable.
Figure 2-6. Ethernet Ports
2.3.3.1 Ethernet Port LEDs
All Ethernet ports use the same LED configuration.
Figure 2-7. Ethernet LEDs
Emerson FBxEdge User Guide
D301913X012
October 2023
6
Pin LED Color LED Status Indicator
13/14 Green
Yellow
Off
LINK1000 (steady on)
LINK100 (steady on)
LINK19
12 Green ACT/LINK
Blink with activity
Steady on with no activity at 10/100/100
2.3.4 Serial Ports
Note
The FBxEdge software does not currently support serial-based communications.
The RXi2-LP provides two serial interfaces, one (1) configured to RS-232 and one (2)
configurable to RS-422 or RS-485 (2W/4W). The connector is a Phoenix Contact 1953745 or
equivalent and mates with a Phoenix Contact 1952296. Two mating plugs are shipped
with the unit. The RS-232 cable can be no longer than 15m. The RX-4xx cable can be more
than 30m, depending on capacitive cable load.
Figure 2-8. Serial Ports
Signal Name RS-232 Pin
TXD 1
RXD 2
RTS 3
CTS 4
GND 5
Signal Name RS-485 Pin
TX+ 6
TX– 7
RX+ 8
RX– 9
GND 10
For RS–422 and RS–485-4-wire modes, connect the corresponding RX+/– signals with the
TX+/– signals and vice versa on the remote device. For RS–485 2-wire mode, connect RX+
Emerson FBxEdge User Guide
D301913X012
October 2023
8
2.5 Mounting the RXi2 LP Edge Device
CAUTION
Install the RXi2-LP edge device only in restricted access locations.
Important
The RXi2-LP edge device is designed only to be mounted horizontally. Mounting it
vertically prevents the housing’s heatsink fins from appropriately cooling the device.
All units ship with a wall mount bracket attached to the base of the CPU. The figure below
shows the attachment specifications for the wall mount bracket.
Figure 2-11. Minimum Clearances for RXi2 LP
Emerson FBxEdge User Guide
D301913X012
October 2023
9
Chapter 3. Configuring the Edge Device
Each FBxEdge device requires an IP address for communications and configuration.
3.1 Acquiring an IP Address
By default configuration, an FBxEdge device acquires an IP address dynamically from its
DHCP server. However, if the device is connected to a network which does not have a
DHCP server, you must manually assign a static IP address to the device.
3.1.1 IP Address Assigned by DHCP Server
Before configuring an FBxEdge device, you first need the IP address the DHCP server
dynamically assigns to that device:
1. Attach a keyboard (using the USB port) and a monitor (using the DP port) to the edge
device.
2. Connect the edge device to your network with an Ethernet cable.
3. Connect the edge device to power.
4. Press the power button (located at the left rear of the RXi2 LP) and wait for the edge
device to boot.
Emerson FBxEdge User Guide
D301913X012
October 2023
10
Figure 3-1. Edge Device Welcome Screen
5. Review the screen and record the server-assigned IP value (here,
https://10.211.223.133).
Once you have the IP address for the edge device, proceed to Section 3.2, Accessing
FBxEdge.
3.1.2 IP Address Assigned Manually
To assign a static IP address to an FBxEdge device:
1. Attach a keyboard (using the USB port) and a monitor (using the DP port) to the edge
device.
Note
The device’s user interface does not support a mouse. You must use the keyboard to
navigate. Use the Tab key to move from one field to the next. Use the arrow keys
() to select list items, and use the Enter key to select an option or move to the
next display in the workflow.
The user interface logs you out if no activity occurs within a few minutes. You must
then press F2 to log back in.
2. Connect the edge device to your network with an Ethernet cable.
Emerson FBxEdge User Guide
D301913X012
October 2023
11
3. Connect the edge device to power.
4. Press the power button (located at the left rear of the RXi2 LP) to boot the edge
device. When the system startup is complete, the device’s welcome screen displays.
5. Press F2 to enter the setup.
6. For the initial login, you must select a keyboard layout. Use the up and down arrows
() on your keyboard to select a keyboard layout. The us keyboard is sufficient for
most English keyboards.
Figure 3-2. Edge Device Keyboard Layout Screen
7. Press Enter to select that layout. The login screen displays:
Figure 3-3. Edge Device Login Screen
For the initial login, the credentials are admin and edge.
8. Enter the initial credentials (use the Tab key to move from one field to the next).
9. Tab to Log In and press Enter.
For the initial login when using a static IP address, the License Agreement screen
displays:
Emerson FBxEdge User Guide
D301913X012
October 2023
12
Figure 3-4. License Agreement Screen
10. Use the down arrow key to scroll through the license agreement.
11. Press Enter to accept the license. The Change Password screen displays:
Figure 3-5. Change Password Screen
12. Press Enter to accept the license. The Change Password screen displays:
13. Enter the old password (edge). Tab to the New field and enter a new password (based
on the password recommendations).
14. Tab to the Confirm field and re-enter the new password.
15. Tab to select Change and press Enter. The System Settings screen (Figure 3-6)
displays.
Emerson FBxEdge User Guide
D301913X012
October 2023
13
3.1.2.1 Setting the Static IP Address
The user interface for the FBxEdge device duplicates many of the configuration options
available through the web interface. To set a static IP address, select the Configure
Interfaces option.
Figure 3-6. System Settings Screen
1. Tab to the Configure Interfaces option and press Enter. The Select interface screen
displays.
Figure 3-7. Interface Configuration Screen
2. Enter the name of an interface (here, eth0), tab to Next, and press Enter. The
Interface screen displays for the selected interface:
Emerson FBxEdge User Guide
D301913X012
October 2023
14
Figure 3-8. Interface Screen
3. Use the Tab key to select the desired option (here, IPv4 or IPv6) and then tab over the
fields (Type, None, Auto, etc.) to select Static. Tab down to Apply and press Enter.
The screen adds CIDR and Gateway fields:
Figure 3-9. Interface Screen
4. Complete the fields as necessary:
• CIDR: Classless Inter-Domain Routing notation defines a block of IP addresses
(similar to network subnetting). This example notation (192.168.0.251/24) means
that the first 24 bits of the IP address are used for network routing.
• Gateway: Defines the default gateway address on a network, which can be
locating using the ipconfig command.
5. Tab to Apply and press Enter. The System Settings screen displays.
Emerson FBxEdge User Guide
D301913X012
October 2023
15
Figure 3-10. System Setting Screen
6. Tab to Reboot and press Enter. The Reboot screen displays.
Emerson FBxEdge User Guide
D301913X012
October 2023
16
Figure 3-11. Reboot Screen
7. Press Enter to confirm the reboot. Once the reboot completes, the Welcome to
FBxEdge screen displays, showing the static IP address (here, 192.168.1.251).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

Remote Automation Solutions FBxEdge User guide

Category
Networking
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI