GE JVW5361SJSS Pyramid Wall Chimney Vent Hood is designed to be a powerful ventilation solution for your kitchen. With its sleek design and stainless steel finish, it not only enhances the aesthetics of your space but also offers a range of features to ensure efficient odor and smoke removal. The 3-speed fan control allows you to adjust the ventilation level based on your cooking needs, while the dishwasher-safe aluminum filters make cleaning a breeze.

GE JVW5361SJSS Pyramid Wall Chimney Vent Hood is designed to be a powerful ventilation solution for your kitchen. With its sleek design and stainless steel finish, it not only enhances the aesthetics of your space but also offers a range of features to ensure efficient odor and smoke removal. The 3-speed fan control allows you to adjust the ventilation level based on your cooking needs, while the dishwasher-safe aluminum filters make cleaning a breeze.

Pyramid Wall
Chimney Vent Hoods
Installation
Instructions
BEFORE YOU BEGIN
Read these instructions carefully and completely.
■ IMPORTANTSavetheseinstructionsfor
localinspector’suse.
■ IMPORTANTObserveallgoverningcodes
andordinances.
■ Note to Installer – Besuretoleavetheseinstructions
withConsumer.
■ Note to Consumer – Keeptheseinstructionsfor
futurereference.
■ Skill level –Installationofthisappliancerequiresa
qualiedinstallerorelectrician.
■ Completion time –Approximately1to3hours
■ Properinstallationistheresponsibilityoftheinstaller.
■ Productfailureduetoimproperinstallationisnot
coveredunderWarranty.
FOR YOUR SAFETY:
WARNING
Beforebeginningtheinstallation,
switchpoweroffattheservicepanelandlockthe
servicedisconnectingmeanstopreventpowerfrom
beingswitchedonaccidentally.Whentheservice
disconnectingmeanscannotbelocked,securely
fastenaprominentwarningdevice,suchasatag,to
theservicepanel.
WARNING
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A.Installationworkandelectricalwiringmustbe
donebyqualiedperson(s)inaccordancewithall
applicablecodesandstandards,includingre-rated
construction.
B.Sufcientairisneededforpropercombustionand
exhaustingofgasesthroughtheue(chimney)of
fuelburningequipmenttopreventbackdrafting.
Followtheheatingequipmentmanufacturer’s
guidelinesandsafetystandardssuchasthose
publishedbytheNationalFireProtection
Association(NFPA),theAmericanSocietyfor
Heating,RefrigerationandAirConditioning
Engineers(ASHRAE)andthelocalcode
authorities.
C.Whencuttingordrillingintowallorceiling,donot
damageelectricalwiringandotherhiddenutilities.
D.Ductedfansmustalwaysbeventedtothe
outdoors.
E.Turnoffbreakertoadjacentroomswhileworking.
WARNING
TO REDUCE THE RISK OF FIRE,
USE ONLY METAL DUCT WORK.
CAUTION
Duetotheweightandsizeof
theseventhoodsandtoreducetheriskofpersonal
injuryordamagetotheproduct,TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737)
or visit our website at: GEAppliances.com
JVW5301, JVW5361
(991.0480.581)31-10983-502-17GEA
2 31-10983-5
Installation Instructions
INSTALLATION CLEARANCES
Theseventhoodsaredesignedtobeinstalledontoa
wallwithnoabovecabinets.
Theventhoodmustbeinstalledbetweenthe24”
requiredminimumand38”recommendedmaximum
abovethecookingsurface.Thehoodinstallation
heightabovethecookingsurfacedependsupon
ceilingheightandductcoverlimitations.The
telescopicductcoverconcealstheductworkrunning
fromthetopofthehoodtotheceiling.Forsupplied
ductcoverceilingheights,seetableonpage5.
NOTE: Installationheightshouldbemeasuredfrom
thecookingsurfacetothelowestpartofthehood.
Thishoodmustbeinstalledontoawall.Itcanbe
ventedtotheoutdoors,oritcanbeinstalledfor
recirculatingoperation.Forrecirculationoperation,see
Recirculation Install Planning.
PRODUCT DIMENSIONS
8-1/4”
13”
30”to36”
1-3/8”
9-7/8”
17-3/8”Min.
24-7/16"Max.
18-1/2”
3-5/16”
7-1/16”
13”
5”
2”
4-1/4”
24”RequiredMin.
38”RecommendedMax.
31-10983-5 3
Installation Instructions
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
FORPERSONALSAFETY,THISAPPLIANCEMUST
BEPROPERLYGROUNDED.
Removehousefuseoropencircuitbreakerbefore
beginninginstallation.
Donotuseanextensioncordoradapterplugwith
thisappliance.FollowNationalElectricalCodesor
prevailinglocalcodesandordinances.
Electrical supply
Theseventhoodsmustbesuppliedwith120V,60Hz,
andconnectedtoanindividual,properlygrounded
branchcircuit,andprotectedbya15or20ampcircuit
breakerortimedelayfuse.
•Wiringmustbe2wirewithground.
•Iftheelectricalsupplydoesnotmeettheabove
requirements,callalicensedelectricianbefore
proceeding.
•Routehousewiringasclosetotheinstallation
locationaspossibleintheceilingorwall.
•Connectthewiringtothehousewiringinaccordance
withlocalcodes.
Grounding instructions
Thegroundingconductormustbeconnectedto
agroundmetal,permanentwiringsystem,oran
equipment-groundingterminalorleadonthehood.
WARNING
Theimproperconnectionofthe
equipment-groundingconductorcanresultinarisk
ofelectricshock.Checkwithaqualiedelectricianor
servicerepresentativeifyouareindoubtwhetherthe
applianceisproperlygrounded.
ADVANCE PLANNING
Duct Install Planning
• Thishoodisdesignedtobeventedvertically
throughtheceiling.Usea6"roundduct.Uselocally
suppliedelbowstoventhorizontallythroughtherear
wall.
• Usemetalductworkonly.
• Determinetheexactlocationoftheventhood.
• Plantherouteforventingexhausttotheoutdoors.
Tomaximizetheventilationperformanceofthevent
system:
1.Minimizetheductrunlengthandnumberof
transitionsandelbows.
2.Maintainaconstantductsize.
3.Sealalljointswithducttapetopreventanyleaks.
4.Donotuseanytypeofexibleducting.
• Installawallcaporroofcapwithdamperatthe
exterioropening.Purchasethewallorroofcapand
anytransitionandlengthofductneededinadvance.
• Whenapplicable,installanymakeup(replacement)
airsysteminaccordancewithlocalbuildingcode
requirements.VisitGEAppliances.comforavailable
makeupairsolutions.
Recirculation Install Planning
Arecirculationduct(included)andtwocharcoal
lters(notincluded)arenecessaryforrecirculation
installation.
Power Supply Planning
Thelocationofthepowersupplyconnectioniscalled
outinthePrepare the Wallsectiononpage6.
4 31-10983-5
Installation Instructions
TOOLS AND MATERIALS
REQUIRED (NOTSUPPLIED)
PLAN THE INSTALLATION
CAUTION
Toreduceriskofreandto
properlyexhaustair,besuretoducttheairoutside
–Donotventexhaustairintospaceswithinwallsor
ceilingsorintoattics,crawlspaces,orgarages.
PARTS SUPPLIED FOR INSTALLATION
•1HardwarePackage
•1LiteraturePackage
PARTS NEEDED FOR INSTALLATION
•1StrainRelief
•PowerSupplyCable
•1WallorRoofCap(forductedventingonly)
•AllMetalDuctwork(forductedventingonly)
•RecirculationDuct(forrecirculationinstallonly)
WARNING
PERSONAL INJURY HAZARD
Becauseoftheweightandsizeoftherangehood
canopy.Itisrecommendedthat2peopleareused
toinstalltherangehood.Failuretoproperlylift
rangehoodcouldresultindamagetotheproductor
personalinjury.
NOTE: Thisrangehoodcanbeinstalledaseither
ductedorrecirculation.Inaductedapplication,this
rangehoodcanbeventedthroughthewallorceiling.
Wheninstalledforrecirculation,therangehoodvents
outthesidesoftheductcover.
NOTE: Beforemakinganycutsorholesfor
installation,determinewhichventingmethodwillbe
usedandcarefullycalculateallmeasurements.
REMOVE THE PACKAGING
CAUTION
Wearglovestoprotectagainst
sharpedges.
•Removetheductcovers.
•Removethehardwarebag,literaturepackageand
otherboxedparts.
•Removeandproperlydiscardtheprotectiveplastic
wrappingandotherpackagingmaterials.
Wirecutter/stripper
Level
Aluminized
Ducttape
Safetyglasses
Strainrelieffor
junctionbox
Strain Relief I
Electricdrillwith#2Phillips,
athead,and9/32"drillbit
ULlistedwirenuts
Wire Nuts
Pencilandtapemeasure
31-10983-5 5
Installation Instructions
RANGE HOOD COMPONENTS
HARDWARE COMPONENTS
INSTALLATION DIMENSIONS
ThePyramidChimneysareadjustableanddesigned
tomeetvaryingceilingheights.Theductcoverscan
beadjustedforceilingsbetween7’31/4”and9’
dependingonthedistancebetweenthebottomofthe
hoodandthecooktop(distanceX).
A. CanopySection
B. LowerDuctCover
C. UpperDuctCover
D. MountingScrews
E. DuctCover
MountingBrackets
F. DuctCoverScrews
G. Damper
H. CanopyMounting
Anchors
K. DuctCoverAnchors
A
D
B
F
F
D
D
D
E
C
G
I
I
I
H
D F H I
RANGE HOOD RECIRCULATION
COMPONENT
RecirculationDuct
RequiredMin&Recommended
MaxCeilingHeightExamples
x=24" x=38"
Min Min
7'3-1/4" 8'5-1/4"
Max Max
7'10-5/16" 9’
4-3/8”min
11-7/16”max
13”
9-7/8”
36”
X
18-1/2”
X=DistanceFromHoodToCooktop
(Variesdependingoninstallation)
RequiredMin-24”,
RecommendedMax-38”
alsoconsultcooktop
manufacturer’srecommendation
Forhigher
ceiling
installationsup
to10’,usethe
HighCeiling
DuctCover
Kitforyour
model.Use
JXDC72SSfor
StainlessSteel,
orJXDC72ES
forSlate.
Toreacha10’
ceilingwith
theJXDC72
accessory,the
bottomofthe
hoodmustbe
aminimumof
36”fromthe
cooktop.
UpperDuctCover
LowerDuctCover
Canopy
19-3/4”
6 31-10983-5
Installation Instructions
PREPARE THE WALL
Hood Body
1. Putaprotectivecoveringoverthesurfacebelow
thelocationofthehoodtoprotectfromdirtand/or
damage.
2. Determineandmarkthecenterlineonthewall(draw
lineuptotheceiling)wheretherangehoodwillbe
installed.Basedontheceilingheight,determinethe
distance24”requiredmin,38”recommendedmax
(X)neededbetweenthecookingsurface(B)andthe
bottomofthehood.Tothisdistance,add7”anddraw
ahorizontalline(A)about24”longcenteredonthe
verticalcenterline(C).
3. Mark2pointsoneachsideofthehorizontalline(A),
5-1/2”fromtheverticalcenterline(C).Drillthecanopy
mountinganchorsintothewallatthemarkings.Install
the2mountingscrewsintotheanchors,leavinga
1/4”gapbetweenthewallandthebackofthescrew
head.(Youwillplacethehoodbodyontothesescrew
heads.)
4. Drawasecondhorizontalline(D)thatis1-1/4”added
fromtheXdistance.Drawathirdhorizontalline(E)
thatis4-5/16”addedfromtheXdistance.
5. Mark2pointsoneachsideofthehorizontalline(D),
7-7/8”fromtheverticalcenterline(C).Drillthe2holes
forinstallationwitha9/32”drillbit,andinserttheduct
coveranchors.
6. Determineandmarkwheretheholewillbedrilledfor
thepowersupplycabletoberunthroughthewall.
Markapointontheleftsideofthehorizontalline(E),
6-1/4”fromtheverticalcenterline(C).Drilla1-1/4”
holeatthismark.
Duct Covers and Power Supply
1. Placeoneoftheductcoverbracketsagainstthe
wallsothatitstopedgeis1/16”fromtheceilingand
level.Alignthecenternotchesofthebracketandthe
centerline(C)andmarkthecentersofthebracket
holes.Removethebrackettodrillthe2holesfor
installationwitha9/32”drillbit,andinserttheduct
coveranchors.Placethebracketbackonthewall
andinstallthe2mountingscrewsintotheanchors.
Tightenscrews.
2. Placetheotherductcoverbracketonthewallso
thatitstopedgeis10-1/2”fromtheceilingandlevel.
Alignthecenternotchesofthebracketandthe
centerline(C)andmarkthecentersofthebracket
holes.Removethebrackettodrillthe2holesfor
installationwitha9/32”drillbit,andinserttheduct
coveranchors.Placethebracketbackonthewall
andinstallthe2mountingscrewsintotheanchors.
Tightenscrews.
1-1/4
"
4-5/16"
6-1/4"
7"
X
5-1/2" 5-1/2"
A
E
D
C
B
7-7/8" 7-7/8"
C
1/16"
Ceiling
10-1/2
"
31-10983-5 7
Installation Instructions
PREPARE HOOD FOR
INSTALLATION
1.Removethegreaseltersfromtheunitandset
aside.Thegreaseltersare
removedbypressingthe
handleinfrontofthelter.
Whenreplacing,makesure
thattheltersareproperly
positionedwiththehandlesin
frontandvisible.
2.Removeandproperlydiscardtheprotectiveplastic
wrappingfromthehoodandgreaselters.
3.Removejunctionboxcover.
Vented Installations
1.Securelypressdamperontopoftheexhaust
opening.Checkthatthedamperopensfreely.
2.GotoMount the Range Hoodinthissection.
Non-vented (recirculation) Installations
NOTE: Recirculationduct(included)andcharcoal
ltersJXCF72(notincluded)arerequired.The damper
is not installed on the unit with recirculation instal-
lations.
1. Installthenon-vented(ductless)recirculationduct(A)
suppliedwiththeventhood.
B
A
Non-vented (recirculation) Installations
2. Checkthattherecirculationductisinthecorrectori-
entationwiththeholetowardsthefrontofthehood.
Fittherecirculationductovertheventexhaustoutlet
(B)andpushdowntoseatontheoutlet.
3. GotoMounttheRangeHoodinthissection.
NOTE: Hole
mustbefacing
towardfrontof
hood.
MOUNT THE PYRAMID RANGE
HOOD
1. Installtherangehoodbodybyplacingthehoodkey
holesoverthemountingscrews.Feedthepower
supplycablethroughtheelectricalknockout.Tighten
themountingscrews.
2. Insert2mountingscrewsintothe2ductcover
anchors(installedonlineDinPreparingtheWall
section)locatedintheslotsonthebacksurfaceof
thehood.Securetightly.
3. Connectthehouseductingtothedamperonthe
hoodbodyifductedinstall.Sealallconnectionswith
ducttape.NOTE: Ifrecirculationinstallation,skipto
Step4andproceed.
4. Installtheupperductcover.
Slightlyspreadthesidesof
thecoverapartandhookthem
behindtheductcovermounting
brackets.Attachthecoverto
thebracketswith4ductcover
screws.
A
Mounting
ScrewSlots
8 31-10983-5
Installation Instructions
FINISH THE INSTALLATION
(Continued)
3.Usingaatheadscrewdriver,liftupthetabsonthe
topofthecanopy.
4.Toinstallthelowerductcover:
●Useaatheadscrewdrivertopushthetwotabs
forwardonthelowerductcover.
●Angletheductcovertoslidethetabsunder
theledgeofthehoodbody.Seatthebackof
theductcoveronthetopoftherangehood
betweentheedgesandtabs.
5.Turnthepowersupplyon.Turnonblowerand
light.Iftherangehooddoesnotoperate,check
thatthecircuitbreakerisnottrippedorthehouse
fuseblown.Iftheunitstilldoesnotoperate,
disconnectthepowersupplyandcheckthatthe
wiringconnectionshavebeenmadeproperly.
ELECTRICAL CONNECTION
1.ConnectthePowerSupplyCabletotherange
hood.Attachthewhiteleadofthepowersupplyto
thewhiteleadoftherangehood(A)withawirenut
(C).Attachtheblackleadofthepowersupplyto
theblackleadoftherangehood(B)withawirenut
(C).Connectthegreen(D)groundwireunderthe
greengroundingscrew.
2.Replacethejunctionboxcover.
FINISH THE INSTALLATION
1.Forrecirculationinstallationonly:Attachthe
CHARCOALFILTERS(notincluded)tobothsides
oftheblower.Todothis,placethesideofthe
charcoallterwiththetabsagainstthesideofthe
blower.Alignthedoublelinesonthecharcoallter
withthe“unlocked”symbolontheblower.Push
andtwistdownwarduntilthedoublelinesalignwith
the“locked”symbolontheblower.Repeatonother
sidewithsecondlter.
For recirculation and ducted installation:
2.Replacethegreaselters.
B
D
C
A
Tabs
Campanas de Ventilación de
Chimeneas de Pared Pirámide
Instrucciones
de instalación
ANTES DE COMENZAR
Lea estas instrucciones por completo y con detenimiento.
■ IMPORTANTE Guardeestasinstrucciones
paraelusodeinspectoreslocales.
■ IMPORTANTECumplacontodosloscódigos
yordenanzasvigentes.
■ Nota al instalador – Asegúresededejarestas
instruccionesconelConsumidor.
■ Nota al consumidor – Conserveestasinstruccionespara
referenciafutura.
■ Nivel de capacidad – Lainstalacióndeestacampanade
ventilaciónrequierecapacidadesmecánicasyeléctricas
básicas..
■ Tiempo de nalización – Aproximadamente
de1a3horas.
■ Elinstaladortienelaresponsabilidaddeefectuaruna
instalaciónadecuada.
■ LaGarantíanocubrelasfallasdelproductodebidoauna
instalaciónincorrecta.
PARA SU SEGURIDAD:
ADVERTENCIA
Antesdecomenzarlainstalación,
desconectelaenergíadelpaneldeservicioybloqueelos
mediosdedesconexiónparaevitarelaccionamientode
laenergíademaneraaccidental.Cuandolosmediosde
desconexióndeservicionopuedenbloquearse,coloque
sobreelpaneldeservicioundispositivodeadvertenciabien
visible,comounaetiqueta.
ADVERTENCIA
PARA REDUCIR EL RIESGO DE
INCENDIO, DESCARGA ELÉCTRICA
O LESIONES A PERSONAS, CUMPLA CON LOS
SIGUIENTES PUNTOS:
A.Eltrabajodeinstalaciónyelcableadoeléctricodebenser
realizadosporunapersona(s)calicadadeacuerdocon
todosloscódigosyestándaresaplicables,incluyendo
construccionesresistentesalfuego.
B.Esnecesariocontarconsucientecantidaddeaire
paraunacombustiónysalidadegasesadecuadasa
travésdelconducto(chimenea)delequipodeconsumo
decombustible,andeevitarráfagasdeaire.Sigalas
pautasdelfabricantedelequipodecalefacciónylos
estándaresdeseguridad,talescomoaquellospublicados
porlaAsociaciónNacionaldeProteccióncontra
Incendios(NationalFireProtectionAssociation,NFPA),la
SociedadEstadounidenseparalaCalefacción(American
SocietyforHeating),losIngenierosdeRefrigeración
yAcondicionadoresdeAire(RefrigerationandAir
ConditioningEngineers,ASHRAE)ylasautoridadesde
loscódigoslocales.
C.Alcortaroperforarunaparedouncielorraso,nodañeel
cableadoeléctricoydeotrosserviciosocultos.
D.Losventiladoresconconductosiempredebencontarcon
ventilaciónhaciaelexterior.
E.Desconecteeldisyuntordehabitacionesadyacentes
mientrasestétrabajando.
ADVERTENCIA
A FIN DE REDUCIR EL RIESGO
DE INCENDIOS, USE SÓLO CONDUCTOS DE METAL.
PRECAUCIÓN
Debidoalpesoytamañode
estascampanasdeventilaciónyparareducirelriesgode
lesionespersonalesodañosalproducto,SE NECESITAN
DOS PERSONAS PARA REALIZAR UNA INSTALACIÓN
CORRECTA.
JVW5301, JVW5361
(991.0480.581)31-10983-502-17GEA
Ante cualquier duda, llame a GE Appliances al 800.GE.CARES (800.432.2737)
o visite nuestro sitio Web en: GEAppliances.com
2 31-10983-5
Preparación para la instalación
ESPACIO DE INSTALACIÓN
Estascampanasdeventilaciónestándiseñadasparaser
instaladasenunaparedsingabinetessuperiores.
Lacampanadeventilacióndebeserinstaladaentreel
mínimorequeridode24”yelmáximorecomendadode38”
sobrelasuperciedecocción.Laalturadeinstalaciónde
lacampanasobrelasuperciedecoccióndependedela
alturadelcielorrasoylaslimitacionesdelacubiertadel
conducto.Lacubiertaplegableocultalosconductosquevan
desdelapartesuperiordelacampanahastaelcielorraso.
Paralasalturasdecielorrasodelascubiertasdeconductos,
consultelatabladelapágina5.
NOTA: Laalturadeinstalacióndebemedirsedesde
lasuperciedecocciónhastalapartemásbajadela
campana.Puedecontarconventilaciónhaciaelexterior,
opuedeserinstaladaparaunfuncionamientocon
recirculación.Paraunfuncionamientoconrecirculación,
consultelaPlanicación para la Instalación con
Recirculación.
DIMENSIONES DEL PRODUCTO
8-1/4”
13”
30”to36”
1-3/8”
9-7/8”
17-3/8”Min.
24-7/16"Max.
18-1/2”
3-5/16”
7-1/16”
13”
5”
2”
4-1/4”
24”Mín.Requerido
38”Máx.Requerido
31-10983-5 3
Preparación para la instalación
SUMINISTRO DE ENERGÍA
IMPORTANTE – (Tenga a bien leer cuidadosamente)
ADVERTENCIA
PARASEGURIDADPERSONAL,ESTEAPARATODEBE
CONECTARSEATIERRADEMANERAADECUADA.
Quiteelfusibleoabraelinterruptordecircuitosantesde
comenzarlainstalación.
Noutiliceuncabledeextensiónounenchufeadaptador
conesteartefacto.SigalosCódigosEléctricosNacionaleso
códigosyordenanzaslocalesvigentes.
Suministro eléctrico
Estascampanasdeventilacióndebencontarconun
suministrode120V,60Hz,debenestarconectadasaun
circuitoderivadoindividualconunaadecuadaconexióna
tierraydebencontarconlaproteccióndeuninterruptorde
circuitosounfusibleconretrasode15o20amperios.
●Elcableadodebeserde2hilosconconexiónatierra.
●Sielsuministroeléctriconocumpleconlosrequisitos
anteriores,llameaunelectricistaconlicenciaantesde
continuar.
●Dirijaelcableadodomésticolomáscercaposiblea
laubicacióndelainstalación,enelcielorrasoopared
trasera.Verpágina14paramásdetalles.
●Conecteelcableadoalcableadodomésticoen
cumplimientoconloscódigoslocales.
Instrucciones de conexión a tierra
Elconductoratierradebeconectarseaunmetalcon
conexiónatierra,unsistemadecableadopermanenteouna
terminaloconductordeconexiónatierradelequipamiento
enlacampana.
ADVERTENCIA
Unaconexióninadecuadadel
conductordeconexiónatierradelequipamientopuede
provocarunriesgodedescargaeléctrica.Consulteaun
electricistacalicadoorepresentantedeserviciotécnicosi
tienedudassobrelacorrectaconexiónatierradelartefacto.
PLANIFICACIÓN PREVIA
Planicación para la Instalación con Conducto
●Estacampanaestádiseñadaparaventilarse
enformaverticalatravésdelcielorraso.Useunconducto
circularde6”.Utilicecodossuministradosenformalocal
paraventilaciónhorizontalatravésdelaparedtrasera.
●Determinelaubicaciónexactadelacampana
deventilación.
●Planiqueelrecorridodelasalidadeventilaciónhacia
elexterior.Andemaximizarelrendimientodela
ventilacióndelsistemadeventilación:
1.Minimicelalongituddelconductoyelnúmerode
transicionesycodos.
2.Mantengauntamañodeconductoconstante.
3.Selletodaslasjuntasconcintaparaconductosande
evitarpérdidas.
4.Noutiliceconductosexiblesdeningúntipo.
●Instaleunacubiertadeparedocasquete
detechoconunreguladordetiroenlaaberturaexterior.
Soliciteporadelantadolacubiertadeparedoelcasquete
detechoycualquiertransiciónolongituddeconducto
necesarios.
●Cuandocorresponda,instaleunsistemadereposición
(reemplazo)deairedeacuerdoconlosrequisitosdel
códigolocaldeconstrucción.Paraaccederasoluciones
deairedisponibles,visiteGEAppliances.com.
Planicación de Instalación con Recirculación
Unconductoderecirculación(incluido)yunltrode
carbón(noincluido)sonnecesariosparalainstalacióncon
recirculación.
Planicación del Suministro de Corriente
Laubicacióndelaconexióndelsuministrodecorrientees
indicadaenlaseccióndePreparacióndelaParedenla
página6.
4 31-10983-5
Preparación para la instalación
HERRAMIENTAS Y MATERIALES
REQUERIDOS (NOSUMINISTRADOS)
PLAN DE INSTALACIÓN
PRECAUCIÓN
Andereducirriesgosde
incendiosyparaqueelairesalgadeformaapropiada,
asegúresedequeelaireseaconducidohaciafuera-No
ventileelairedelasalidahaciaespaciosdentrodeparedes
ocielorrasosoáticos,espaciosmuybajosogarajes.
PIEZAS PROVISTAS PARA LA INSTALACIÓN
●1PaquetedeHerramientas
●1PaqueteEscrito
PIEZAS NECESARIAS PARA LA INSTALACIÓN
1AmortiguadordeRefuerzo
CabledeSuministrodeCorriente
UnaTapadeParedoTecho(paraventilacióncon
conductoúnicamente)
TodalaTuberíaMetálica(paraventilaciónconconducto
únicamente)
ConductodeRecirculación(parainstalacióncon
recirculaciónúnicamente)
ADVERTENCIA
! RIESGO DE LESIONES PERSONALES
Debidoalpesoytamañodelabasedelacampana
extractora.Esrecomendablequelacampanaextractorasea
instaladapor2personas.Silacampananoeselevadade
formacorrecta,sepodránproducirdañossobreelproducto
olesionespersonales.
NOTA: Estacampanapuedeserinstaladaconconducto
oconrecirculación.Enunaaplicaciónconconducto,esta
campanapuedeserventiladaatravésdelaparedodel
cielorraso.Alserinstaladaporrecirculación,lacampana
ventilahaciaafueraloscostadosdelacubiertadel
conducto.
NOTA: Antesderealizarcualquiercorteoagujeroparala
instalación,determinequémétododeventilaciónseráusado
yconcuidadocalculetodaslasmedidas.
QUITE EL ENVOLTORIO
PRECAUCIÓN
Seguantesparaprotegersede
losbordesalados.
●Quitelascubiertasdelosconductos.
●Quitelabolsadepiezas,elpaquetedeinstruccionesy
otraspiezasencajas.
●Quiteydescarteadecuadamenteelenvoltorioplásticode
protecciónyotrosmaterialesdeempaque.
Alicatepelacables
Nivel
Cintaaislante
dealuminio
Gafasdeseguridad
Aliviodetensiónpara
lacajadeconexiones
Strain Relief I
BrocaeléctricaconPhillipsNº2de
cabezaplanaybrocade9/32”
Taponesdealambre
aprobadosporUL
Wire Nuts
Lápizycintamétrica
31-10983-5 5
Preparación para la instalación
COMPONENTES DE LA CAMPANA
EXTRACTORA
A. SeccióndelaBase
B. CubiertadelConducto
Inferior
C. CubiertadelConducto
Superior
D. TornillosdeMontaje
E. SoportesdeMontajedela
CubiertadelConducto
F. TornillosdelaCubierta
delConducto
G. Regulador
H. SoportesdeMontajedela
BasedelaCampana
I. SoportesdelaCubierta
delConducto
COMPONENTES DE RECIRCULACIÓN
COMPONENTES DE LAS
HERRAMIENTAS
DIMENSIONES DE INSTALACIÓN
LasChimeneasdePirámidesonajustablesyestán
diseñadasparaadaptarseadiferentesalturasde
cielorraso.Lascubiertasdelosconductospuedenser
ajustadasparacielorrasosdeentre7’31/4”and9’,
dependiendodeladistanciaentrelaparteinferiorde
lacampanaylasuperciedecocción(distanciaX).
A
D
B
F
F
D
D
D
E
C
G
I
I
I
H
13”
9-7/8”
36”
X
18-1/2”
Para
instalacionesen
cielorasosmás
altosdehasta
10’,useelKit
delCobertorde
Tuberíaspara
CieloRasos
acordeasu
modelo.Useel
JXDC72SSpara
AceroInoxidable,
oelJXDC72ES
paraLosa.
Parallegaraun
cielorasode10’
conelaccesorio
JXDC72,la
parteinferior
delacampana
deberáestara
unmínimode
36”desdela
superciede
cocción.
CubiertadelConductoSuperior
CubiertadelConductoInferior
Dosel
19-3/4”
X=DistanciaDesdelaCampanaHastala
SuperciedeCocción
(Varíadependiendodelainstalación)
MínimoRequerido–24”,
MáximoRequerido–38”;
tambiénconsultelarecomendacióndel
fabricantedecocinas
Ejemplos de Altura Mínima Requerida y
Altura Máxima Recomendada de Cielorraso
x = 24" x = 38"
Mín. Mín
7'3-1/4" 8'5-1/4"
Máx. Máx.
7'10-5/16" 9’
Mín.de4-3/8”
Máx.de11-7/16”
D F H I
ConductodeRecirculación
6 31-10983-5
Preparación para la instalación
PREPARE LA PARED
Cuerpo de la Campana y Suministro de Corriente
1. Coloqueunacubiertaprotectorasobrelasuperciedebajo
delaubicacióndelacampana,andeprotegerdela
suciedady/odaños.
2. Determineymarquelalíneacentralsobrelapared
(dibujelalíneahaciaarribahastaelcielorraso)dondela
campanaextractoraseráinstalada.Enbasealaalturadel
cielorraso,determineladistanciamínimarequeridade24”
yladistanciamáximarecomendadade38”(X),necesarias
entrelasuperciedecocción(B)ylaparteinferiorde
lacampana.Aestadistancia,agregue7”ydibujeuna
líneahorizontal(A)deaproximadamente24”delongitud
centradasobrelalíneacentralvertical(C).
3. Marque2puntosacadaladodelalíneahorizontal(A),a
5½”desdelalíneacentralvertical.Agujereelossostenes
demontajedelapartesuperiordelapared,dondese
encuentranlasmarcas.Instalelos2tornillosdemontaje
enlossostenes,dejandounespaciode¼”entrelapared
ylapartetraseradelacabezadeltornillo.(Debecolocarel
cuerpodelacampanaenlascabezasdeestostornillos).
4. Marqueunasegundalíneahorizontal(D)de1¼”,
agregadadesdeladistanciaX.Marqueunaterceralínea
horizontal(D)de45/16”,agregadadesdeladistanciaX.
5. Marque2puntosacadaladodelalíneahorizontal(D),a
77/8”desdelalíneacentralvertical(C).Haga2agujeros
paralainstalaciónconunabrocade9/32”,einsertelos
sostenesdelacubiertadelconducto.
6. Determineymarqueellugardondeelagujeroserá
perforadoparaqueelcabledesuministrodecorriente
puedapasaratravésdelapared.Marqueunpuntodel
ladoizquierdodelalíneahorizontal(E),a6½”desdela
líneacentralvertical(C).Hagaunagujerode1¼”enesta
marca.
Cubiertas de Conductos
1. Coloqueunodelossoportesdelacubiertadelconducto
contralapared,demodoquesuextremosuperioresté
a1/16”delcielorrasoyquequedenivelado.Alineelas
ranurascentralesdelsoporteconlalíneacentral(C)y
marqueloscentrosdelosagujerosdelsoporte.Retireel
soporteparaperforar2agujerosparalainstalacióncon
unabrocade9/32”,einsertelossostenesdelacubierta
delconducto.Vuelvaacolocarelsoporteenlaparede
instalelos2tornillosdemontajeenlossostenes.Ajustelos
tornillos.
2. Coloqueelotrosoportedelacubiertadelconductocontra
lapared,demodoquesuextremosuperiorestéa10-1/2”
delcielorrasoyquequedenivelado.Alineelasranuras
centralesdelsoporteconlalíneacentral(C)ymarquelos
centrosdelosagujerosdelsoporte.Retireelsoportepara
perforar2agujerosparalainstalaciónconunabrocade
9/32”,einsertelossostenesdelacubiertadelconducto.
Vuelvaacolocarelsoporteenlaparedeinstalelos2
tornillosdemontajeenlossostenes.Ajustelostornillos.
1-1/4
"
4-5/16"
6-1/4"
7"
X
5-1/2" 5-1/2"
A
E
D
C
B
7-7/8" 7-7/8"
C
1/16"
Ceiling
10-1/2
"
Cielorraso
31-10983-5 7
Preparación para la instalación
PREPARE LA CAMPANA PARA SU
INSTALACIÓN
1. Retirelosltrosdegrasadelaunidadydejelosmismos
aunlado.Losltrosdegrasasonretiradospresionando
lamanijaqueseencuentrafrente
alltro.Alrealizarelreemplazo,
asegúresedequelosltrosestén
correctamenteposicionadoscon
lasmanijasenelfrenteyvisibles.
2. Retireydescartedeforma
adecuadaelenvoltorioprotector
deplásticodelacampanaydelos
ltrosdegrasa.
3. Retirelatapadelacajadeempalmes.
Instalaciones Ventiladas
1. Deformasegura,presioneelreguladorqueseencuentra
sobrelaaberturadelescape.Controlequeelregulador
sepuedaabrirlibremente.
2. ConsultesobreelMontajedelaCampanaenesta
sección.
Instalaciones sin ventilación (recirculación)
NOTA: Serequiereelconductoderecirculación(incluido)y
losltrosdecarbónJXCF72(noincluidos).El regulador no
está instalado en la unidad con instalaciones de recircu-
lación.
1. Instaleelconductoderecirculación(A)(sinconducto)
suministradoconlacampanadeventilación.
B
A
Instalaciones sin ventilación (recirculación)
(continúa)
2. Controlequeelconductoderecirculaciónseencuentre
enlaorientacióncorrectaconelagujerohaciaelfrentede
lacampana.Inserteelconductoderecirculaciónsobrela
salidadelescapedeventilación(B)yempujehaciaabajo
paraquecoincidaconlasalida.
3. ConsultesobreelMontajedelaCampanaenestasec-
ción.
NOTA:Elagu-
jerodebeestar
enfrentadohacia
elfrentedela
campana.
MONTE LA CAMPANA DE LA
COCINA PIRÁMIDE
1. Instaleelcuerpodelacampanadelacocina,colocando
losagujerosdelacampanasobrelostornillosdel
montaje.Conecteelcabledesuministrodecorrientea
travésdeltableroeléctrico.Ajustelostornillosdemontaje.
2. Inserte2tornillosdemontajeenlos2sostenesdela
cubiertadelconducto(instaladosenlalíneaDenla
seccióndePreparación de la Pared),ubicadosenlas
ranurasdelasupercietraseradelacampana.Ajustede
manerarme.
3. Conecteelconductohogareñoalreguladordelcuerpode
lacampanasiserealizóunainstalaciónconunconducto.
Selletodaslasconexionesconcintaparaconducto.
NOTA:Sisetratadeunainstalaciónconrecirculación,
vayaalPaso4yproceda.
4. Instalelacubiertadelconducto
superior.Lentamenteseparelos
costadosdelacubiertayenganche
ambosdetrásdelossoportesde
montajedelacubiertadelconducto.
Adhieralatapaalossoportescon4
tornillosdelacubiertadelconducto.
A
Ranurasde
losTornillosde
Montaje
8 31-10983-5
Preparación para la instalación
FINALICE LA INSTALACIÓN
(continúa)
3. Conundestornilladordepuntaplana,levantelas
lengüetassobreelextremodelapartesuperior.
4. Parainstalarlacubiertadelconductoinferior:
● Useundestornilladordecabezaplanaparaempujar
lasdoslengüetashaciadelantesobrelatapadel
conductoinferior.
● Doblelacubiertadelconductoparadeslizarlas
lengüetasdebajodelestantedelcuerpodela
campana.Apoyelapartetraseradelatapadel
conductosobrelapartesuperiordelacampanadela
cocina,entrelosextremosylaslengüetas.
5. Enciendaelsuministrodecorriente.Enciendael
calefactorylaluz.Silacampanadelacocinano
funciona,controlequeeldisyuntornosehayaactivado
oqueelfusiblehogareñoestéquemado.Silaunidad
aúnnofunciona,desconecteelsuministrodecorriente
ycontrolequelasconexionesdelcableadohayansido
realizadasdeformacorrecta.
CONEXIÓN ELÉCTRICA
1. ConecteelCabledeSuministrodeCorrienteala
campanaextractora.Conecteelconductorblanco
delsuministrodecorrientealconductorblancodela
campanaextractora(A)conunatuercaparacable(C).
Conecteelconductornegrodelsuministrodecorriente
alconductornegrodelacampanaextractora(B)conuna
tuercaparacable(C).Conecteelcableatierraverde(D)
debajodeltornillodeconexiónatierraverde.
2. Reemplacelatapadelacajadeempalmes.
B
D
C
A
FINALICE LA INSTALACIÓN
1. Sóloparainstalacionesderecirculación:AdhieralosFIL-
TROSDECARBÓN(noincluidos)sobreambosladosdel
calefactor.Parahaceresto,coloqueellateraldelltrode
carbónconlaslengüetascontraelcostadodelcalefactor.
Alineelaslíneasdoblesdelltrodecarbónconelsímbolo
“desbloqueado”enelcalefactor.Presioneydoblehacia
abajohastaquelaslíneasdoblessealineenconelsím-
bolo“bloqueado”enelcalefactor.Repitaesteprocesodel
otroladoconelsegundoltro.
Para instalaciones de recirculación y con conducto:
2. Reemplacelosltrosdegrasa.
Tabs
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

GE JVW5361SJSS Installation guide

Category
Cooker hoods
Type
Installation guide
This manual is also suitable for

GE JVW5361SJSS Pyramid Wall Chimney Vent Hood is designed to be a powerful ventilation solution for your kitchen. With its sleek design and stainless steel finish, it not only enhances the aesthetics of your space but also offers a range of features to ensure efficient odor and smoke removal. The 3-speed fan control allows you to adjust the ventilation level based on your cooking needs, while the dishwasher-safe aluminum filters make cleaning a breeze.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages