ENGLISH RAISmanualforRaisRina&RaisViva
1
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISRINA&RAISVIVA
IMPORTANTINFORMATION
Onfirstlightingthestove youmustbecarefulnottotouchthepainted
surfacesanditisMOSTIMPORTANTthat thedooriskeptslightly‘ajarin
orderforthedoorseal andsealanttocure.
Thiswillpreventthedoorsealstickingtothe paintedbodyandbecoming
damaged.
ENGLISH RAISmanualforRaisRina&RaisViva
2
ENGLISH RAISmanualforRaisRina&RaisViva
3
Revision:
Date :2011
INTRODUCTION ………………………………………………………….. 4
WARRANTY …………………………………………………….………….. 4
SPECIFICATIONS………………………………………………………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY…………………………………………………….…………. 89
HEARTH………………………………………………………………… 9
INSTALLATION………………………………………………..……... 11
COMMISSIONINGANDHANDOVER……………………………… 11
MANUFACTURERSPLATE………………………………………………. 1213
CHANGINGTHECHIMNEYCONNECTION…………………………….. 14
INSTALLATIONDISTANCETOCOMBUSTIBLEWALL…………....... 1520
INSTALLATIONDISTANCETONONCOMBUSTIBLEWALL……… 21
FORTHEINSTALLER……………………………………………………… 21
OPERATINGINSTRUCTIONS…………………………………………….. 26
FUEL…………………………………………………………………………... 26
DRYINGANDSTORAGE…………………………………………………… 27
REGULATIONOFCOMBUSTIONAIR…………………………………… 27
ROOMVENTILATIONANDSTOVES…………………………………….. 27
USINGTHEWOODBURNINGSTOVE…………………………………… 28
FIRSTUSAGE………………………………………………………………… 29
LIGHTINGANDFUELLING………………………………………………… 3031
CLEANINGANDCARE…………………………………………………….. 32
CLEANINGOFTHEFLUEWAYS………………………………………… 33
PROBLEMSOLVING……………………………………………………….. 34
ACCESSORIESANDSPAREPARTS……………………………………. 35
SPAREPARTDIAGRAM…….………..……………………………………. 3645
CERTIFICATEOFCONFORMITY..………………………………………… 46
ENGLISH RAISmanualforRaisRina&RaisViva
4
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyou
careaboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwood
burningstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedatthebackofthestoveatthebottom.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbySCA/HETASas
intermittentoperatingappliancesforburningwoodl ogsonly.
TheseapplianceshavebeenapprovedforuseinSmokelessZones
ENGLISH RAISmanualforRaisRina&RaisViva
5
Rina90
Nominaloutput(kW): 4.6
Heatingarea(m
2
): Ca.3090
Size,widt h/depth/height(mm): 461/410/900
Combustionchamberwidth/depth/height(mm). 295/225/393
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.2
Min.uptake/Min.draught(Pascal): 12
Weight(kg): (SteelDoo r/GlassDoor) 105
Efficiency(%) 79
ParticlesafterNS3058/3059(g/kg) 1.39
DustmeasuredaccordingtoDin+(mg/Nm
3
) 11
Smokegasmassflow(g/s): 4
Smokegastemperature(°C): 271
Intermittentoperation: Fuellingshould
beundertaken
within3hours
Viva98
Viva98G
4.6
Ca.3090
Ø440/980
295/225/393
320/225/393
1.2
12
98
79
1.39
11
4
271
Fuellingshould
beundertaken
within3hours
Viva120
Viva120G
4.6
Ca.3090
Ø440/1200
295/225/393
320/225/393
1.2
12
104
79
1.39
11
4
271
Fuellingshould
beundertaken
within3hours
Specifications
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3mstraightflue.
ENGLISH RAISmanualforRaisRina&RaisViva
6
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedin
atthebaseofthestoveand upthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature which
meansyoucouldalmostdoawaywithgloves.Beaware,however,thatallexterior
surfacesbecomehotduringuse  sotakeextremecare.
ENGLISH RAISmanualforRaisRina&RaisViva
7
PleasenotethatitisalegalrequirementunderEnglandandWalesBuilding
RegulationsthattheinstallationofthestoveiseithercarriedoutunderLocal
AuthorityBuildingControlapprovalorisinstalledbyaCompetentPerson
registeredwithaGovernmentapprovedCompetentPersonsScheme.HETASLtd
operatesuchaSchemeandalistingoftheirRegisteredCompetentPersonsca n
befoundontheirwebsiteatwww.hetas.co.uk.
COAlarms:
Buildingregulationsrequirethatwheneveraneworreplacementfixedsolidfuel
orwood/biomassapplianceisinstalledinadwellingacarbonmonoxidealarm
mustbefittedinthesameroomastheappliance.Furtherguidanceonthe
installationofthecarbonmonoxidealarmisavailableinBSEN50292:2002and
fromthealarmmanufacturer’sinstructions.
Provisionofanalarmmustnotbeconsideredasubstituteforeitherinstallingthe
appliancecorrectlyorensuringregularservicingandmaintenanceoftheappli
anceandchimneysystem.
HEALTHANDSAFETYPRECAUTIONS
Specialcaremustbetakenwheninstallingthestovesuchthattherequirementsofthe
HealthandSafetyatWorkActaremet.
Handling
Adequatefacilitiesmustbeavailableforloading,unloadingandsitehandling.
FireCement
Sometypesoffirecementarecausticandshould notbeallowedtocomeintocontact
withtheskin.Incaseofcontactwashimmediatelywithplentyofwater.
Asbestos
Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbinganyasbestosin
thecourseofinstallationthenpleaseseek specialistguidanceanduseappropriate
protectiveequipment.
MetalParts
Wheninstallingorservicingthisstovecareshouldbetakentoavoidthepossibilityof
personalinjury.
Theseinstructions togetherwiththoseintheinstructionbookletcover
thebasicprinciplestoensurethesatisfactoryinstallationofthestove,
althoughdetailmayneedslightmodificationtosuitparticularlocalsite
conditions.
InallcasestheinstallationmustcomplywithcurrentBuildingRegulations,
LocalAuthorityByelawsandotherspecificationsorregulationsastheyaffect
theinstallationofthestove.
ItshouldbenotedthattheBuildingRegulationsrequirementsmaybemetby
adoptingtherelevantrecommendationsgiveninBritishStandardsBS8303,
BSEN152871:2007asanalternativemeanstoachieveanequivalentlevelof
performancetothatobtainedfollowingtheguidancegiveninApproved
DocumentJ.
ENGLISH RAISmanualforRaisRina&RaisViva
8
STOVEPERFORMANCE
IntheUKthestovehasbeenapprovedbyHETASLtdasanintermittentoperating
applianceforburningwoodlogsonly.
Itshouldbenotedthatitisanoffencetoburnwoodlogsinthisstoveifitisinstalledwithin
aSmokeControlAreaintheUK,unlessithasbeenaccreditedasaSm okeControl
Exemptappliance(Checkwithyoursupplier/installer).
PREPARATORYWORKANDSAFETYCHECKS
IMPORTANTWARNING
Thisstovemustnotbeinstalledintoachimneythatservesanyotherheatingappliance.
Theremustnotbeanextractorfanfittedinthesameroomasthestoveasthiscancause
thestovetoemitfumesintotheroom.
Chimney
Inorderforthestovetoperformsatisfactorilythechimneyheightmustbesufficientto
ensureanadequatedraughtofapproximately15Pasoastocleartheproductsof
combustionandpreventsmokeproblemsintotheroom.
NOTE:Achimneyheightofnotlessthan4.5metresmeasuredverticallyfromtheoutletof
thestovetothetopofthechimneyshouldbesatisfactory.Alternativelythecalculation
proceduregiveninEN133841maybeusedasthebasisfordecidingwhetheraparticular
chimneydesignwillprovidesufficientdraught.
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3m
straightflue.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsofBuildingRegulationsApprovedDocumentJ.
Ifinstallationisintoanexistingchimneythenitmustbesoundandhavenocracksorother
faultswhichmightallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230mmx230mm.
Remedialactionshouldbetaken,ifrequired,seekingexpertadvice,ifnecessary.Ifitis
foundnecessarytolinethechimneythenafluelinersuitableforsolidfuelmustbeusedin
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandhavebeenswe ptcleanimmediately
beforeinstallationofthestove.Ifthestoveisfittedinplaceofanopenfirethenthe
chimneyshouldbesweptonemonthafterinstallationtoclearanysootfallswhichmay
haveoccurredduetothedifferenceincombustionbetweenthestoveandtheopenfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimneyinaccordance
withBuildingRegulationsApprovedDocumentJoratwi nwall edinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandBuildingRegulations.
ENGLISH RAISmanualforRaisRina&RaisViva
9
Asinglewallmetalfluepipeissuitableforconnectingthestovetothec himneybutisnot
suitableforusingforthecompletechimney.Thechimneyandconnectingfluepipemust
haveaminimumdiameterof150mmanditsdimensionshouldbenotlessthanthesizeof
theoutletsocketofthestove.
Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°bendsshould
notbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthewallsof
fireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthepresenceof
combustiblematerialsdueaccountmustbetakenoftheguidanceontheseparationof
combustiblematerialgiveninBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
Ifitisfoundthatthereisexcessivedraughti nthechimneythenadraughtstabilisershould
befitted.Fittingofadraughtstabiliserwillaffecttherequirementforthepermanentair
supplyintotheroominwhichthestoveisfittedinaccordancewithApprovedDocumentJ
(seealsocombustionairsupply).
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovidedfor
sweepingthechimneyandconnectingfluepipewhereitisnotintendedforthechimneyto
besweptthroughtheappliance,alsotopermitvisualchecksontheintegrityoftheflue
whentheapplianceisserviced.
Hearth
Thehearthshouldbeabletoaccommodatetheweightofthestoveanditschimneyifthe
chimneyisnotindependentlysupported.Theweightofthestoveisindicatedinthe
brochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasi zeand
constructionthatisinaccordancewiththeprovisionsofthecurrentBuildingRegulations
ApprovedDocumentJ.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
If the stove is to be installed on a combustible floor surface, it must be covered with a
noncombustible material at l east 12mm thick, in accordance with Buildi ng Regulations
ApprovedDocumentJ,toadistanceof30cminfrontofthestoveand15cmtoeachside
measuringfromthedoorofthecombustionchamber.
ENGLISH RAISmanualforRaisRina&RaisViva
10
Combustionairsupply
Inorderforthestovetoperformefficientlyandsafelythereshouldbeanadequateair
supplyintotheroominwhichthestoveisinstalledtoprovidecombustionair.Thisis
particularlynecessaryiftheroomisdoubleglazedorafluedraughtstabiliseris
operatinginthesameroomastheappliance.Itmaybenecessarytoincreasetheair
ventsizeinpropertywithlowairpermeability(<5.0m
3
/(h.m
2
).
Theprovisionofairsupplytothestovemustbei naccordancewithcurrentBuilding
RegulationsApprovedDocumentJ.Anopeni ngwindowisnotappropriateforthis
purpose.
IMPORTANTNOTE:Ifapplicableandtheapplianceisbeingfittedwithinanexisting
fireplacerecess,specialistadviceshouldbesoughtbeforefittingany permanent
ventilationwithinthisarea.
Connectiontochimney
Stovesmayhaveachoiceofeitherarearortopfl uegasconnectorthatallows
connectiontoeitheramasonrychimneyoraprefabricatedfactorymadeinsulatedmetal
chimneyinaccordancewiththeirinstructions.Insomecasesitmaybenecessarytofit
anadaptortoincreasethediameterofthefluetotheminimumrequired150mmsection
ofthechimneyorliner.
ElectricalServices
Theinstallationofanyelectricalservicesduringtheinstallationofthisappliancemustbe
carriedoutbyaregisteredcompetentelectricianandinaccordancewiththe
requirementsofthelatestissueofBS7671
CarbonMonoxideAlarm
AcarbonmonoxidealarmcomplyingwithBSEN50292mustbefittedinthesameroom
astheappliance.Itshouldbepositionedontheceilingatleast300mmfromanywallor,
ifitislocatedonawall,ashighupaspossible(aboveanydoorsandwindows)butnot
within150mmoftheceiling.Thealarmshouldalsobebetween1mand3mhorizontally
fromtheappliance.
ENGLISH RAISmanualforRaisRina&RaisViva
11
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,i n
ordertoensurepropercombustion.Notethatanymechanicalexhaustventilation
e.g.anextractionhoodmayreducethea irsupply.Anyairgrillesmustbeplaced
insuchamanner,thattheairsupplyisnotblocked.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionai rofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,as
wellastheweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,yo ushould
considertheheatdistributiontotheotherrooms.Thiswillenableyoutogetthebest
useoutofyourstove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
Commissioningandhandover
Ensureloosepartsarefittedinaccordancewitht heinstructionsgiveninthe
instructionbooklet.
Oncompletionoftheinstallationallowasuitableperiodoftimeforanyfirecement
andmortartodryout,whenasmallfiremaybelitandcheckedtoensurethe
smokeandfumesaretakenfromthestoveupt hechimneyandemittedsafelyto
atmosphere.Donotrunatfulloutputforatleast24hours.
Oncompletionoftheinstallationandcommissioningensurethattheoperating
instructionsforthestoveareleftwiththecustomer.Ens uretoadvisethecustomer
onthecorrectuseoftheappliancewithth efuelslikelytobeusedonthestoveand
warnthemtouseonlytherecommendedfuelsforthestove.
Advisetheuserwhattodoshouldsmokeorfumesbeemittedfromthestove.The
customershouldbewarnedtouseafireguardtoBS8423:2002(ReplacesBS
6539)inthepresenceofchildren,agedand/orinfirmpersons.
ENGLISH RAISmanualforRaisRina&RaisViva
12
ENGLISH RAISmanualforRaisRina&RaisViva
13
ENGLISH RAISmanualforRaisRina&RaisViva
14
Removethecasingknockout.
Removetheprotectivecover/sealandplaceoverthe
holeinthetopmakesurethatthesealispositioned
properly.TightentheassemblyusingthethreeM6 nuts.
Theflueoutletspigot,whichcanbefoundinthestoveina
bag,andtheholderfortheupperfluediverterare
assembledwith3M6x20nutsandbolts.
Theupperfluediverter,baffleplateandtopplateare
assembledinreverseorder.
Changingthechimneyconnection
ENGLISH RAISmanualforRaisRina&RaisViva
15
Installationdistancetocombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledis
flammable,youshouldcontactyourbuildingcontractororthelocalbuilding
authorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimney
mustbeindependentlysupportedbywallbracketsoraceilingsupportplate.The
weightofthestoveisindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasi zeand
constructionthatisinaccordancewiththeprovisionsofthecurrentUKBuilding
RegulationsApprovedDocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanon
combustiblematerialatleast12mmthick,inaccordancewithUKBuilding
RegulationsApprovedDocumentJ,toadistanc eof300mminfrontofthestove
and150mmtoeachsidemeasuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthe
hearthandwallsadjacenttothehearthshouldcomplywiththeguidanceonthe
separationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDocumentJand
alsointhesestoveinstructions.
Informtheuserthattheappliancehasbeencommissi onedandreadytouseand
give
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandt heusershouldbeinstructedto
keeptheminasafeplace.
ENGLISH RAISmanualforRaisRina&RaisViva
16
Normalsetupcornersetting
RINA
A. Distancetofurniture 700mm
Distancetoflammablematerials:
B. infront(floor) 300mm
C. totheside(floor) 150mm
D. totherear(floor) 150mm
E. tothesideofthewall 350mm
ENGLISH RAISmanualforRaisRina&RaisViva
17
Normalsetupcornersetting
VIVA VIVAG
A. Distancetofurniture 700mm 650mm
Distancetoflammablematerials:
B. infront(floor) 300mm 300mm
C. totheside(floor) 150mm 150mm
D. totherear(floor) 100mm 150mm
E. tothesideofthewall 350mm 400mm
ENGLISH RAISmanualforRaisRina&RaisViva
18
Cornersetting45°fixedsocket
RINA
A. Distancetofurniture 700mm
Distancetoflammablematerials:
B. infront(floor) 300mm
C. totheside(floor) 150mm
D. totherear(wall) 150mm
E. tothesideofthewall 350mm
ENGLISH RAISmanualforRaisRina&RaisViva
19
Cornersetting45°fixedsocket
VIVAVIVAG
Distancetofurniture700mm 650mm
Distancetoflammablematerials:
B. infront(floor) 300mm 300mm
C. totheside(floor) 150mm 150mm
D. totherear(wall) 100mm 200mm
E. tothesideofthewall 350mm 400mm
ENGLISH RAISmanualforRaisRina&RaisViva
20
360°SwivelBase
VIVAVIVAG
Distancetofurniture700mm 650mm
Distancetoflammablematerials:
C. totheside(floor) 300mm 300mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

RAIS VIVA Instructions For Installation, Use And Maintenance Manual