ENGLISH RAISmanualforRaisRina&RaisViva
8
STOVEPERFORMANCE
IntheUKthestovehasbeenapprovedbyHETASLtdasanintermittentoperating
applianceforburningwoodlogsonly.
Itshouldbenotedthatitisanoffencetoburnwoodlogsinthisstoveifitisinstalledwithin
aSmokeControlAreaintheUK,unlessithasbeenaccreditedasaSm okeControl
Exemptappliance(Checkwithyoursupplier/installer).
PREPARATORYWORKANDSAFETYCHECKS
IMPORTANTWARNING
Thisstovemustnotbeinstalledintoachimneythatservesanyotherheatingappliance.
Theremustnotbeanextractorfanfittedinthesameroomasthestoveasthiscancause
thestovetoemitfumesintotheroom.
Chimney
Inorderforthestovetoperformsatisfactorilythechimneyheightmustbesufficientto
ensureanadequatedraughtofapproximately15Pasoastocleartheproductsof
combustionandpreventsmokeproblemsintotheroom.
NOTE:Achimneyheightofnotlessthan4.5metresmeasuredverticallyfromtheoutletof
thestovetothetopofthechimneyshouldbesatisfactory.Alternativelythecalculation
proceduregiveninEN133841maybeusedasthebasisfordecidingwhetheraparticular
chimneydesignwillprovidesufficientdraught.
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3m
straightflue.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsofBuildingRegulationsApprovedDocumentJ.
Ifinstallationisintoanexistingchimneythenitmustbesoundandhavenocracksorother
faultswhichmightallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230mmx230mm.
Remedialactionshouldbetaken,ifrequired,seekingexpertadvice,ifnecessary.Ifitis
foundnecessarytolinethechimneythenafluelinersuitableforsolidfuelmustbeusedin
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandhavebeenswe ptcleanimmediately
beforeinstallationofthestove.Ifthestoveisfittedinplaceofanopenfirethenthe
chimneyshouldbesweptonemonthafterinstallationtoclearanysootfallswhichmay
haveoccurredduetothedifferenceincombustionbetweenthestoveandtheopenfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimneyinaccordance
withBuildingRegulationsApprovedDocumentJoratwi nwall edinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandBuildingRegulations.