  • Hello! I am an AI chatbot trained to assist you with the 3M ScaleGard™ HP Reverse Osmosis System Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
3M
Water Filtration Products
Reverse Osmosis Cartridge Change-out Instructions
FOR ScaleGard
TM
HP Reverse Osmosis System
WARNING
To reduce the risk associated with the ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
To reduce the risk associated with choking:
• Do notallowchildrenunder3yearsofagetohaveaccesstosmallpartsduringtheinstallationofthisproduct.
To reduce the risk of physical injury:
• Depressurizesystemasshowninmanualpriortocartridgeremoval.
To reduce the risk of injury associated with household bleach:
• Read and followmanufacturer’sdirectionsandcautions.
• Keep out of the reach of children.
• DO NOTintermixwithotherchemicals.
To reduce the risk associated with ingestion of water contaminated with sanitizer:
•Afterinstallation,sanitizersmustbeushedfromthesystembeforerstuseasdirectedwithintheinstallationinstructions
(dilutebleachsolution).
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Protect from freezing,removeltercartridgewhentemperaturesareexpectedtodropbelow40°F(4.4°C).
• Do notinstallsystemsinareaswhereambienttemperaturesmaygoabove110°F(43.3°C).
• TheROcartridgeMUSTbereplacedeverytwentyfour(24)months,orsoonerifanoticeableincreaseinTDSoccurs.
• ThedisposableltercartridgesMUSTbereplacedeverysix(6)months,attheratedcapacityorsoonerifanoticeablereductioninowrate
occurs.
IMPORTANT NOTE:
TheROcartridgeshavegreenlabelsandwillonlytintotheheadontherightsideofthemanifold(headhasagreen3Mlabel).
Shut-Off procedure:
HFRO500Cartridgeswillneedtobechangedatleasteverytwentyfour(24)months.HF90-CL-ROcartridgewillneedtobechangedeverysix(6)months.
1. Unplugsystemfromthewalloutlet,whichwillshutofffeedwatertoROsystem.
2. OpenPre-ltersamplevalveuntilowstopsandpressuregaugereaches0psitorelievepressure.
HF90-CL-RO Cartridge (blue label) Replacement:
1. Pushandholdyellowtabtoreleasecartridgelockingmechanismwhilesimultaneouslyrotatingcartridgetotheleft.
2. Usingbothhandsandholdingthecartridgefromthebottom,rotatethecartridgeaquarterturntotheleftandgentlypulldown.
NOTE:Asmallamountofwaterwilldrainfrommanifoldascartridgeisremoved.
3. Removesanitarycapfromnewcartridge.Installwithaquarterturntotherightuntilcartridgecometoacompletestop.
NOTE:Cartridgesarekeyedtotinproperlocationonly.
HFRO 500 Cartridge (green label) Replacement:
1. Takeoutrejecttubingbypushinginthecolletandpullingoutthetubing.(Seegureonreverse).
2. Pushandholdyellowtabtoreleasecartridgelockingmechanismwhilesimultaneouslyrotatingcartridgetotheleft.
3. Usingbothhandsandholdingthecartridgefromthebottom,rotatethecartridgeaquarterturntotheleftandgentlypulldown.
NOTE:Asmallamountofwaterwilldrainfrommanifoldascartridgeisremoved.
4. Removesanitarycapfromnewcartridge.Installwithaquarterturntotherightuntilcartridgecomestoacompletestop.
NOTE:Cartridgesarekeyedtotinproperlocationonly.
5. Placenewowcontrolinrejecttubing(suppliedwithcartridge).
6. Connectrejecttubingtocartridge.
System Start Up
1. TurnONthefeedwatersupplybypluggingsystemintoelectricaloutlet.
2. Pressresetbuttonontopofelectricalenclosure(seeFigure5).
3. OpenPre-ltervalvesamplevalvetoventairfromsystemandushforve(5)minutes.
4. Closesamplevalve.
5. Sanitize the Storage Tank and Filtration System as per instructions below
Sanitizingthestoragetankgenerallyrequires:
• Commonhouseholdbleach(5.25%non-scented)orsanitizingagent
• Eyedropperorplasticoralsyringe
a.) Disconnectthe1/2”linefrommarked”TankOutlet”topressuretank.
b.) Insert1tablespoonofbleachorsanitizingagentinto1/2”linetopressuretank.
c.) Reconnectthe1/2”linetopressuretank.
d.) TurnONthefeedwatersupplybypluggingsystemintoelectricaloutlet.
e.) Wait4-5hours.
f.) Openpressuretanksamplevalveandemptytanktodrain.
3Misatrademarkof3MCompany.
ScaleGardisatrademarkof3MCompany.
©20123MCompany.Allrightsreserved.
Pleaserecycle.PrintedinU.S.A.
INSTR44011012
3M Purification Inc.
400ResearchParkway
Meriden,CT06450,U.S.A.
Tel (866)990-9785
(203)237-5541
Fax (203)238-8977
www.cunofoodservice.com
www.3Mpurication.com
Limited Warranty
3MPuricationInc.warrantsthisdisposableltercartridgeormembraneiswarrantedfromdefectsinmaterialandmanufactureforaperiodofone(1)yearfromthedate
ofpurchase.Thiswarrantydoesnotcoverfailuresresultingfromabuse,misuse,alterationordamagenotcausedby3MPuricationInc.orfailuretofollowinstallation
anduseinstructions.Nowarrantyisgivenastotheservicelifeofanyltercartridgeormembraneasitwillvarywithlocalwaterconditionsandwaterconsumption.
3M PURIFICATION INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY
OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF
DEALING, CUSTOMER OR USAGE OF TRADE.IftheProductfailstosatisfythisLimitedWarrantyduringthewarrantyperiod,3MPuricationInc.willreplacetheProductor
refundyourProductpurchaseprice.Thiswarrantydoesnotcoverlabor.TheremedystatedinthisparagraphisCustomer’ssoleremedyand3M’sexclusiveobligation.
Thiswarrantygivesyouspeciclegalrights,andyoumayhaveotherrightswhichmayvaryfromstatetostate,orcountrytocountry.Foranywarrantyquestions,pleasecall(866)
990-9785ormailyourrequestto:WarrantyClaims,3MPuricationInc.,400ResearchParkway,Meriden,CT06450.Proofofpurchase(originalsalesreceipt)mustaccompany
thewarrantyclaim,alongwithacompletedescriptionoftheProduct,modelnumberandallegeddefect.
Limitation of Liability
3MPuricationInc.willnotbeliableforanylossordamagearisingfromtheuseoftheProduct(s),whetherdirect,indirect,special,incidental,orconsequential,regardlessofthe
legaltheoryasserted,includingwarranty,contract,negligenceorstrictliability.Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sothe
abovelimitationmaynotapplytoyou.
Figure 1 (Reset Button)
Reset
Button
To Attach Tubing
To Release Tubing
Push tubing straight in as far as it
will go
Tubing is secured in. Push in collet to release tubing. Pull tubing straight out.
Thisproductisoutttedwithauserfriendly‘PushIn’connectorattheventvalve.Properuseoftheconnectorsisshowninthegurebelow.Itismost
importantthatthetubingselectedforusewiththeseconnectorsbeofhighquality,exactsizeandroundness,andwithnosurfacenicksorscratches.
Ifitisnecessarytocutthetubing,useaplastictubingcutterorsharprazorknife.Makeacleansquarecut.Shouldaleakoccurata“Push-In”
connector,thecauseisusuallyaproblemwiththetubing.
To Fix:
1.Relievepressure 2.Releasetubing 3.Cutoffatleast1/4”fromend
4.Reattachtubing 5.Conrmconnectionisleakfree
Figure 6 (How to Use “Push-in” Connectors)
g.) Sanitizingisnowcomplete.
h) Ifthereisanyresidualchlorine/bleachtasteinthenexttank
full,draintankcompletelyasecondtime.
6. Allowtanktollagain.
Systemisnowreadyforuse.
/