Danfoss Insulation EPS and XPS for SpeedUp Installation guide

Type
Installation guide
1 Installation of Additional Insulation EPS/XPS for SpeedUp
Fig. 1: The substrate must be dry, level and load bearing
(roughness tolerance max. 3 mm/m).
Fig. 2: Attach SpeedUp perimeter insulation on the wall. Avoid
overlapping the ends. ¹
Fig. 3: Lightly score corners of perimeter insulation 3 cm from
below, inside corners from the wall and outside corners from
room side.
Fig. 4: Remove lap joints from the first insulation panels to
achieve full coverage up to wall.
Fig. 5: Lay insulation panels in a staggered pattern and cross-
laid to the eventual direction of the SpeedUp heat panels.
Fig. 6: When cutting to fit the next panel ensure that the lap
joints always. Only use whole panels through thresholds.
Installation Guide
Additional Insulation EPS/XPS for SpeedUp
Danfoss Heating Solutions VICSB302
1
Fig. 7: Lighter constructions require the insulation to be glued
at the perimeter, under SpeedUp header panels and through
thresholds.
Fig. 8: Second or third layers of insulation must always be
cross-laid to the ones below. The last layer must be cross-laid
to SpeedUp heat panels above.
Fig. 9: Enclose pipe section (maximum width 30 cm according
to BEB/ZDB Information leaflet) and fill up with bonded
compound level with insulation. Pipe sections with insulated
pipes and above 20 cm must be covered with a 1 mm metal
sheet. ²
Fig. 10: Protect insulation from frequent pedestrian traffic to
avoid damage.
¹ Additional insulation ≥ 5 cm is laid without perimeter insulation but position the perimeter insulation afterwards on the additional insulation.
² For light floor constructions (e.g. when laying laminate/parquet directly on the heat panel and all strongboard constructions) pipe channels -
in the additional insulation - with a width of more than 10 cm must be covered with a metal plate (min. 1 mm). If the pipe channels have a
width of more than 15 cm a special loadbaring plate (min. 18 mm) must be used.
Installation Guide Additional Insulation EPS/XPS for SpeedUp
VICSB302 Produced by Danfoss Heating Solutions © 11/2010
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
  • Page 1 1
  • Page 2 2

Danfoss Insulation EPS and XPS for SpeedUp Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI