Fig. 7: Always cross-lay the second layer of insulation panels.
The final layer of insulation must be cross-layed to the
SpeedUp heat panels.
Fig. 8: Enclose pipe section with panels (max. width 30 cm
according to BEB/ZDB Information leaflet), fix and fill up with
bonded compound up to level of insulation.
Fig. 9: Pipe sections with insulated pipes and width from 20 cm
must be covered with a 1 mm aluminium plate and with 5 cm
overlap. ²
Fig. 10: Protect insulation from frequent pedestrian traffic to
avoid damage.
¹ Additional insulation ≥ 5 cm is laid without perimeter insulation. Position the perimeter insulation afterwards on the additional insulation.
² For light floor constructions (e.g. when laying laminate/parquet directly on the heat panel and all strongboard constructions) pipe channels -
in the additional insulation - with a width of more than 10cm must be covered with a metal plate (min. 1 mm). If the pipe channels have a
width of more than 15 cm a special loadbaring plate (min. 18 mm OSB or similar) must be used.
Installation Guide Additional Wood Fibre Insulation for SpeedUp Eco
VICSE302 Produced by Danfoss Heating Solutions © 11/2010
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.