Equinox Systems Stage Haze 1500 User manual

  • Hello! I am an AI chatbot trained to assist you with the Equinox Systems Stage Haze 1500 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Order code: EQLED357
Stage Haze 1500
User Manual
www.prolight.co.uk Stage Haze 1500 User Manual
2
Safety advice
WARNING - FOR YOUR OWN SAFETY, PLEASE READ THIS USER
MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
Beforellingtheunitdisconnectthemains.Neverllwithhotliquids.
Onlyusehighquality,waterbasedsmokeuidrecommendedbythemanufacturer.
Othersmokeuidsmaycausecloggingandvoidtheguarantee.
Alwaysmakesurethereissufcientsmokeuidinthetank.Operatingthissmokemachine
withoutsmokeuidwillcausedamagetothepumpaswellasoverheatingoftheheater.
Operatetheunitonlyafteryouhavefamiliarisedyourselfwithitsfunctions.Donotpermitoperation
bypersonsnotqualiedforoperatingtheunitandalwaysdrainthetankandusetheoriginalpackaging
iftheunitistobetransported.
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithothercables.
Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotswitchtheequipmentonandoffinshortintervals,asthis
willreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandlethe
power-cablebytheplug.Neverpullouttheplugbypullingthe
power-cable.
• Makesurethattheavailablemainssupplyvoltage
is240VAC,50Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthemains
powersupplyimmediatelyandhaveaqualiedengineerinspect
theequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreachedroom
temperature.
• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.
Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLightdealer
forservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINSNO
USERSERVICEABLEPARTS.
• Thisxtureisforprofessionaluseonly-itisnotdesignedforor
suitableforhouseholduse.Theproductmustbeinstalledbya
qualiedtechnicianinaccordancewithlocalterritoryregulations.
Thesafetyoftheinstallationistheresponsibilityoftheinstaller.
Thexturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• WARRANTY:Oneyearfromdateofpurchase.
www.prolight.co.uk Stage Haze 1500 User Manual
3
Product overview & technical specications
Aprofessional1500Wstagehazemachine
housedinaightcase.Fastwarm-uptime
andamassive6litreuidtankallowforlong
durationusebetweenrellsmakingitideal
forproductionandevents.EasytouseLCD
functiondisplaymenuforcontrolovertimer,
continuoushazeandmanualhazeoptions.
•1500Wheater
•Output:approx.30,000cu.ftperminute(fullon)
•Warm-uptime:approx.3minutes
•Tankcapacity:6litres
•DMXchannels:2
•Timer,manualandDMXmodes
•6pushbuttonmenuwithLCDdisplay
•PowerCONinput
•3-PinXLRinput/output
•5-PinXLRinput/output
Stage Haze 1500
265mm
575mm 423mm
POWER INPUT: 240V~50Hz
FUSE:
F8A 250V
HAZE OUTLET. EXTREMELY HOT. DO NOT TOUCH.
DO NOT COVER THE OUTPUT SLOT. KEEP AT LEAST 1m DISTANCE.
3-PIN DMX
INPUT
3-PIN DMX
OUTPUT
5-PIN DMX
INPUT
5-PIN DMX
OUTPUT
01 02
070604
03 08
09
05
01-Fluidtank
02-Functionbuttons
03-LCDdisplay
04-3-PinXLRinput/output
05-PowerCONinput
06-5-PinXLRinput/output
07-FuseF8A250V
08-Hazeaperture
09-Airintake
Inthebox:1 x xture,
1 x powerCON cable &
1 x user manual
Specications
Powerconsumption 1600W(max.)
Powersupply 220~240V,50/60Hz
Fuse F8A250V
Dimensions 265x575x423mm
Weight 19kg
Ordercode EQLED357
Housedinightcase
www.prolight.co.uk Stage Haze 1500 User Manual
4
Operation:
Placetheunitonalevelsurface.
Alwaysdisconnectitfromthemainssupplybeforellingasuidcouldbespilled.
Fluid replenishment:
Alwaysllthetankawayfromtheunittopreventuidgettinginsidethemainhousing.
Ifuidshouldgetinsidethemainhousing,disconnecttheunitfromthemainsimmediately
andconsultatechnician.
Releasepipefromtopofbottlebypushingthemetalcollartowardstheuidtank.Thenremovevelcro
strapsecuringtankandremovetank.Onceoutandawayfromunit,standthetankuprightsothecap
ispointingtowardstheceiling.Turncapcounter-clockwisetoremove,thenlltankwithuidand
replacecapturningclockwiseuntiltight.Slidebottlebackintotheunitandsecurewithvelcrostrap.
Thenreattachtheuidpipebypushingitintothemetalcollarontheuidcap,makingsureitclicks
securelyintoposition.
Installation:
Installtheunitinawell-ventilatedarea.Useinaninsufcientlyventilatedroomcanleadtothe
condensationofthehazeuid.Theresultingslipperysurfacecancauseaccidents.Keepaminimum
distanceof1maroundtheunit.
Furthermoredonotorientatetheoutputaperturedirectlyinthedirectionoftheaudience’seyes.
Inordertocreatethebesteffect,thereshouldbeadistancebetweentheunitandtheaudience
ofatleast3m.
Onlyinstallthehazemachineonreresistant,scratchresistantandwaterresistantsurfaces.
Operating instructionsOperating instructions
DANGER OF FIRE!
When installing the unit, make sure there is no highly ammable
material (decoration articles etc) within a minimum distance of 1m
DANGER TO LIFE!
Disconnect from the mains before starting maintenance
Only use quality haze uids recommended by your dealer. You must
not use substances which are classied as ‘DANGEROUS WORKING
MATERIALS’ or ‘FLAMMABLE FLUIDS’.
www.prolight.co.uk Stage Haze 1500 User Manual
5
OnstartuptheLCDdisplaywillshowtheheatingpercentageuptocompletion‘heating 0%’to‘heating
100%’whilsttheunitisheatingupandperformingitsstartupcleancycle(approx.3minutes).
Oncetheheatingupisnisheditwillthendisplay‘Machine ready’,whichmeanstheunit
isreadyforuse.
Timer mode:
Pressthe“FUNCTION”buttonontheunittodisplay‘Wait Time Set Mode:’,youcannowadjustthe
intervaltimefrom1sto600sbyusingtheandbuttons.
Pressthe“FUNCTION”buttontodisplay‘Start Time Set Mode:’,youcannowadjustthehazeoutputtime
from1sto600sbyusingtheandbuttons.
Pressthe“FUNCTION”buttontodisplay‘Timer Smoke Volume Out:’,youcannowadjusttheoutput
volumefrom0%to100%byusingtheandbuttons.
Pressthe“FUNCTION”buttontodisplay‘Fan Adjusting Volume:’,youcannowadjustthefanvolume
from0%to100%byusingtheandbuttons.
Oncesetyoucanthenusethetimerbuttontoenablethismode.
Thedisplaywillshow
‘Haze wait: ___S
Haze start: ___S’
withthesettingsalreadyapplied.
Pressthe buttononcetostophazeoutput.
Manual mode:
Pressthebuttontostartmanualhaze.
Thedisplaywillshowthecurrentsettingseg‘*Haze 50% Fan 100%’.
Youwillnoticean*willappearnexttotheword*Haze,youcannowadjustthesettingaccordinglyusing
theandbuttons.IfyouwanttoadjusttheFan,simplypresstheFUNCTIONbuttonandthe*will
appearnexttotheword*Fanyoucannowadjustthesettingaccordinglyusingtheandbuttons.
Pressthe buttononcetostophazeoutput.
Please note: This mode is for continuous haze.
button:
PressthebuttonuntiltheLCDdisplayshows‘Do not off in clean 300S’.Theunitwillnowperform
itscleaningcycle.OncetheLCDdisplayshows‘To turn off the POWER!!!’,youcanthendisconnectthe
unitfromthemainspowersupply.
Operating instructionsOperating instructions
VOLUME
PUMP/FAN
www.prolight.co.uk Stage Haze 1500 User Manual
6
Operating instructions
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomes
tocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitof
thextureandeachxtureindependently.
Pressthe“FUNCTION”buttontodisplay‘The DMX device address set:’,youcannowadjusttheDMX
addressfrom1to511byusingtheandbuttons.
YoucanthenconnecttheDMXcontroller,thedisplaywillshow
‘DMX-512 Add.:’
‘PMP: F:’.
ThePMP(hazeoutput)andF(fanspeed)canbeadjustedviatheDMXcontroller.
DMX channel mode:
Electronic Fluid-level-sensor:
Iftheuidrunsoutwhilsttheunitisinoperationtheunitwillcontinuetooperateforapprox.2minutes,
afterthistimetheElectronicFluid-level-sensorwillstoptheunitworkingtoprotectit.Whenthishappens
theLCDdisplaywillashandshow‘Beware: No Liquid!’,thismeansthemachinehasrunoutofuid,
pleaserell.
Whenthishappenspleasedothefollowing:
Powerofftheunitanddisconnectfrommainspowersupply.
Relltheuidtank.(Seepage4forinstructionsonuidreplenishment)
Reconnectthemainspowersupply.
Theunitcannowbeoperatedagain.
Troubleshooting:
WhentheLCDdisplayashesandshows‘Machine Temperature is too HIGH’.
Thiscouldindicatetheairlteronthesideoftheunitneedsmaintaining,pleaseseepage7forfurther
instructions.AlternativelythiscouldindicatethatthePCBisfaulty.Iftheproblempersists,please
contactyourdealer.
WhentheLCDdisplayashesandshows‘Temperature sensor error’.
Thiscouldindicatethattheheaterisfaultyandisnotheatinguportheheaterisn’tgettinguptothe
righttemperature.Pleasepowertheunitoffandthenbackon.Iftheproblempersists,pleasecontact
yourdealer.
Channel Value LCD display will show Function
CH1 000-255 PMP(0-100%) Hazeoutputvolume(0-100%)
CH2 000-255 F(0-100%) Fanspeed(slow-fast)
www.prolight.co.uk Stage Haze 1500 User Manual
7
Operating instructions
Cleaning and maintenance:
Werecommendafrequentcleaningoftheunit.Pleaseuseasoftlint-freeandmoistenedcloth.
Neverusealcoholorsolvents!Cleantheoutputnozzlefrequentlyfromhazeuidresidues.Theuidswe
recommendarenon-hazardoustotheenvironmentandcanbedisposedofviathesewagesystem.
Therearenoserviceablepartsinsidethisunitexceptforthefuse.
Maintenanceandserviceoperationsareonlytobecarriedoutbyauthoriseddealers.
PressthebuttonuntiltheLCDdisplayshows‘Do not off in clean 300S’.Theunitwillnowperform
itscleaningcycle.OncetheLCDdisplayshows‘To turn off the POWER!!!’,youcanthendisconnectthe
unitfromthemainspowersupply.
Air lter maintenance:
Withprolongedusetheairlteronthesideoftheightcasecanaccumulatedustanddirt.Youwill
periodicallyhavetoremovethesidecoveroftheightcaseandremovetheairltertocleanit.After
cleaning,pleasemakesuretodrytheairlterthoroughlybeforeinstallingitbackintotheunitand
replacingthesidecover.
Aperture sponge maintenance:
Withprolongedusethespongeinsidetheoutputaperturemayaccumulateresidue,pleaseperiodically
cleanthesponge,orreplacewithanewoneifneeded.
Replacing the fuse:
Onlyreplacethefusewithafuseofsametypeandrating.
Beforereplacingthefuse,disconnectfromthemains,seethefollowingforprocedure:
Step 1: Open the fuse holder on the rear panel with a suitable screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
(Replacementfusesshouldbeofthesamevalueasoriginallysupplied)
Step 4: Replace the fuse holder in the housing.
Shouldyouneedanyspareparts,onlyusegenuineparts.
Ifdefective,pleasedisposeoftheunusableunitinaccordancewiththecurrentlegalregulations.
Shouldyouhaveanyfurtherquestions,pleasecontactyourdealer.
www.prolight.co.uk Stage Haze 1500 User Manual
8
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
www.prolight.co.uk Stage Haze 1500 User Manual
9
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
www.prolight.co.uk Stage Haze 1500 User Manual
10
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
www.prolight.co.uk Stage Haze 1500 User Manual
11
www.prolight.co.uk Stage Haze 1500 User Manual
12
/