Equinox Systems Avalanche EQLED358 User manual

Category
Floodlights
Type
User manual

Equinox Systems Avalanche EQLED358

The Equinox Systems Avalanche EQLED358 is a snow machine designed for large events. It utilizes a large, high output fan to project snow flakes up to 10 meters into the air. The output volume is adjustable and can be controlled from either the supplied wired remote control or via DMX. The unit comes complete with a custom designed flight case for protection during transportation. The robust steel chassis with built in tilt mechanism allows the user to direct the output as required.

With an output volume of 150m3 per minute at full power, the Avalanche EQLED358 is capable of creating a impressive snowfall effect. The fluid consumption is approximately 540ml/min at 100% output. The unit can be controlled manually using the wired remote control or via DMX, making it suitable for a variety of applications.

Equinox Systems Avalanche EQLED358

The Equinox Systems Avalanche EQLED358 is a snow machine designed for large events. It utilizes a large, high output fan to project snow flakes up to 10 meters into the air. The output volume is adjustable and can be controlled from either the supplied wired remote control or via DMX. The unit comes complete with a custom designed flight case for protection during transportation. The robust steel chassis with built in tilt mechanism allows the user to direct the output as required.

With an output volume of 150m3 per minute at full power, the Avalanche EQLED358 is capable of creating a impressive snowfall effect. The fluid consumption is approximately 540ml/min at 100% output. The unit can be controlled manually using the wired remote control or via DMX, making it suitable for a variety of applications.

Order code: EQLED358
Avalanche
Snow Machine
User Manual
www.prolight.co.uk Avalanche Snow Machine User Manual
2
Safety advice
WARNING:
FOR YOUR OWN SAFETY, PLEASE READ THIS USER
MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
240VAC,50Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Thisunitisnotintendedforxedinstallation.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProlight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thisxtureisforprofessionaluseonly-itisnotdesigned
fororsuitableforhouseholduse.Theproductmustbe
installedbyaqualiedtechnicianinaccordancewithlocal
territoryregulations.Thesafetyoftheinstallationisthe
responsibilityoftheinstaller.Thexturepresentsrisksof
severeinjuryordeathduetorehazards,electricshock
andfalls.
• WARRANTY:Oneyearfromdateofpurchase.
• Beforeyourinitialstart-up,pleasemakesurethat
thereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealer
anddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingcondition
andtoensuresafeoperation,itisnecessaryfortheuser
tofollowthesafetyinstructionsandwarningnoteswritten
inthismanual.
• Pleasenotethatdamagescausedbyusermodications
tothisequipmentarenotsubjecttowarranty.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthe
warrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
Beforellingtheunitdisconnectthemains.Neverllwithhotliquids.
Onlyusehighquality,waterbasedsnowuidrecommendedbythemanufacturer.
Othersnowuidsmaycausecloggingandvoidtheguarantee.
Alwaysmakesurethereissufcientsnowuidinthetank.Operatingthissnowmachinewithoutsnowuidwill
causedamagetothepump.
Operatetheunitonlyafteryouhavefamiliarisedyourselfwithitsfunctions.Donotpermitoperationbypersonsnotqualied
foroperatingtheunitandalwaysdrainthetankandusetheoriginalpackagingiftheunitistobetransported.
IMPORTANT: The manufacturer will not accept liability for any resulting damages caused
by the non-observance of this manual or any unauthorised modication to the equipment.
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
www.prolight.co.uk Avalanche Snow Machine User Manual
3
Product overview & technical specications
Designedforlargeevents,theAvalanchefromEquinoxutilisesalarge,
highoutputfantoprojectthesnowakesupto10metresintotheair.
Adjustableoutput,controllablefromeitherthesuppliedwiredremote
controloronboardDMX.Suppliedcompletewithcustomdesigned
ightcaseforprotectionduringtransportation.Therobuststeel
chassiswithbuiltintiltmechanismallowstheusertodirect
theoutputasrequired.
•Outputvolume:150m
3
perminute(fullon)
•Fluidconsumption:540ml/minat100%(approx.)
•Control:WiredremotecontrolandDMX
Avalanche Snow Machine
Specications
Powerconsumption 1500W(max.)
Powersupply 240V,50Hz
Unitdimensions 830x470x820mm
Unitweight 28.8kg
Flightcasedimensions
withwheels
1010x880x520mm
Flightcasedimensions
withoutwheels
890x880x520mm
Flightcaseweight 30kg
Totalweight 58.8kg
Ordercode EQLED358
820mm470mm
830mm
Handheld
RemoteControl
included
Flightcaseincluded
www.prolight.co.uk Avalanche Snow Machine User Manual
4
Technical specications
01-Fluidpipeand
intakeunit
02-Bracket
adjustment
knobs
03-Bracket
04-Powerswitch
05-3-PinXLRoutput
06-3-PinXLRinput
07-Remotecontrol
socket
08-Dipswitches
09-Resettablefuse
15A250V
10-PowerCON
input
Inthebox:
1 x xture, 1 x remote
control, 1 x ightcase
with wheels,
1 x powerCON cable
& 1 x user manual
POWER INPUT:
240V~50Hz
RESETTABLE
FUSE
DMX OUTPUTOFF
REMOTE CONTROL
DIPSWITCHES
ON
DMX INPUT
POWER INPUT:
240V~50Hz
RESETTABLE
FUSE
DMX OUTPUTOFF
REMOTE CONTROL
DIPSWITCHES
ON
DMX INPUT
POWER INPUT:
240V~50Hz
RESETTABLE
FUSE
DMX OUTPUTOFF
REMOTE CONTROL
DIPSWITCHES
ON
DMX INPUT
01
02
03
07 08
10
04 05 06 09
www.prolight.co.uk Avalanche Snow Machine User Manual
5
Operating instructions
Operation:
Placetheunitonalevelsurface.
Alwaysdisconnectitfromthemainssupplybeforellingasuidcouldbespilled.
Alwaysllthetankawayfromtheunittopreventuidgettinginsidethemainhousing.
Ifuidshouldgetinsidethemainhousing,disconnecttheunitfromthemainsimmediately
andconsultatechnician.
Installation:
Installtheunitinawell-ventilatedarea.Useinaninsufcientlyventilatedroomcanleadtothe
condensationofthesnowuid.Theresultingslipperysurfacecancauseaccidents.Keepaminimum
distanceof1maroundtheunit.
Furthermoredonotorientatetheoutputaperturedirectlyinthedirectionoftheaudience’seyes.
Inordertocreatethebesteffect,thereshouldbeadistancebetweentheunitandtheaudience
ofatleast5m.
Onlyinstallthesnowmachineonreresistant,scratchresistantandwaterresistantsurfaces.
Thisunitisconstructedforafreestandinginstallationonly.Theunitcanbeusedwhilstinthebaseof
theightcasewiththelidremoved.Makesureallbrakesareappliedtotheightcaseandtheunit.
Theoperatormustalwaysmakesurethatthesafety-relatingandmachine-technicalinstallationsare
approvedbyanexpertbeforeoperationforthersttimeandafteranyfurtherchangesaremade.
Theoperatorhastomakesurethatthesafety-relatingandmachine-technicalinstallations
areapprovedbyaqualiedpersononceayear.
Important:
Pleasemakesureyouconnectasubstantialuidsourceas5litresofuidwillonlyproduceamaximum
of10minutesfullonsnowoutput.Donotallowtheuidsourcetorundry.
Topreventtheunitfromoverheatingitisadvisedafter20minutesoncontinuousoperationyoustopthe
unitoutputtingsnowforapprox.10minutessotheunitcancooldown.
At the end of each operation water must be run through the pump to prevent seizure.
DANGER OF FIRE!
When installing the unit, make sure there is no highly ammable
material (decoration articles etc) within a minimum distance of 1m
DANGER TO LIFE!
Disconnect from the mains before starting maintenance
Only use quality snow uids recommended by your dealer. You must
not use substances which are classied as ‘DANGEROUS WORKING
MATERIALS’ or ‘FLAMMABLE FLUIDS’.
www.prolight.co.uk Avalanche Snow Machine User Manual
6
Cleaning and maintenance:
Werecommendafrequentcleaningoftheunit.Pleaseuseasoftlint-freeandmoistenedcloth.
Neverusealcoholorsolvents!
Theuidswerecommendarenon-hazardoustotheenvironmentandcanbedisposedofviathe
sewagesystem.
Therearenoserviceablepartsinsidethisunit.
Maintenanceandserviceoperationsareonlytobecarriedoutbyauthoriseddealers.
Breaker reset:
Intheeventofapowerfailure,pleaseresetthe15AbreakerlocatedbelowthePowerCONinput.Ifthe
breakertripsafterithasbeenreset,thisusuallyindicatesacomponentfault.Disconnecttheunitfrom
themainspowersupplyandcontactyourlocaldealerformoreinformation.
Shouldyouneedanyspareparts,onlyusegenuineparts.
Ifdefective,pleasedisposeoftheunusableunitinaccordancewiththecurrentlegalregulations.
Shouldyouhaveanyfurtherquestions,pleasecontactyourdealer.
Operating instructions
www.prolight.co.uk Avalanche Snow Machine User Manual
7
Operating instructions
Operation:
ConnecttheunittoamainspowersupplyviaapowerCONcable.ThenturnthepowerswitchtoON,
theredindicationlightonthepowerswitchwillilluminate.
Formanualcontrolsimplyconnecttheremotecontrolprovidedandfollowtheremotecontrol
operationinstructionsbelow.
Remote control operation:
Ensuretheremotecontrolswitchisoffandtheoutput
volumerotaryknobisturnedcounter-clockwiseuntilit
stops.
Connectthehandheldremotecontroltothemainunitvia
theremotecontrolsocket.Oncetheremoteisconnected
theredpowerindicatorwillilluminate.
PresstheswitchonthehandheldremotecontroltoON,the
greeninuseindicatorwillilluminate.
Whenyouarereadytodispersesnow,turntheoutput
volumerotaryknobclockwisetothedesiredoutput.Tostop
thedispersionofsnowturntheoutputvolumerotaryknob
counter-clockwiseuntilitstops.
Careshouldbetakentoensuretheuidlevelismaintained
andtheunitisnotallowedtorundryofuid.Isolatefrom
themainssupplybeforedisconnectingorreconnectingthe
uidsource.
01-Outputvolume
02-Inuseindicator
03-Powerindicator
04-ON/OFFswitch
01
02
03
04
www.prolight.co.uk Avalanche Snow Machine User Manual
8
Operating instructions
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomesto
customising,controllingorcreatingashow.DMXaddressingisfacilitatedviathedipswitchesonthetop
oftheunit.
Addressing
Eachdeviceoccupies1channel.Toensurethatthecontrolsignalsareproperlydirectedtoeachdevice
thexturerequiresaddressing.Thisneedstobechangedforeveryxturebychangingthedipswitches
assetoutinthetablebelow.Thestartingaddressisdenedastherstchannelfromwhichthe
devicewillrespondtothecontroller.Pleasemakesurethatyoudonothaveanyoverlappingchannels
inordertocontroleachxturecorrectlyandindependentlyfromanyotherxtureontheDMXdatalink.
Iftwo,three,ormoredevicesareaddressedsimilarly,theywillworksimilarly.
Controlling
Afterhavingaddressedall
devices,youmaynowstart
operatingtheseviayour
controller.
Dipswitchnumber 1 2 3 4 5 6 7 8 9
DMXstartingaddress 1 2 4 8 16 32 64 128 256
Occupation of the dipswitches:
Fixture1-Channel1
ON
OFF
Fixture4-Channel4
ON
OFF
Fixture5-Channel5
ON
OFF
Fixture2-Channel2
ON
OFF
Fixture3-Channel3
ON
OFF
Channel Value Function
CH1 000-255 Snowoutput
(0-100%)
1 channel mode
www.prolight.co.uk Avalanche Snow Machine User Manual
9
Operating instructions
DMX dipswitch quick reference chart
DMX DIPSWITCH SET
0 = OFF
1 = ON
#9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
#8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
#7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
#6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
#1 #2 #3 #4 #5
0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480
1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481
0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482
1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483
0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484
1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485
0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486
1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487
0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488
1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489
0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490
1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491
0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492
1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493
0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494
1 1 1 1 0 15 47 79 111 143
175 207 239 271 303 335 367 399 431 463 495
0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496
1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497
0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498
1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499
0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500
1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501
0 1 1 0 1 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502
1 1 1 0 1 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503
0 0 0 1 1 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504
1 0 0 1 1 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505
0 1 0 1 1 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506
1 1 0 1 1 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507
0 0 1 1 1 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508
1 0 1 1 1 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509
0 1 1 1 1 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510
1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511
www.prolight.co.uk Avalanche Snow Machine User Manual
10
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
www.prolight.co.uk Avalanche Snow Machine User Manual
11
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
www.prolight.co.uk Avalanche Snow Machine User Manual
12
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Equinox Systems Avalanche EQLED358 User manual

Category
Floodlights
Type
User manual

Equinox Systems Avalanche EQLED358

The Equinox Systems Avalanche EQLED358 is a snow machine designed for large events. It utilizes a large, high output fan to project snow flakes up to 10 meters into the air. The output volume is adjustable and can be controlled from either the supplied wired remote control or via DMX. The unit comes complete with a custom designed flight case for protection during transportation. The robust steel chassis with built in tilt mechanism allows the user to direct the output as required.

With an output volume of 150m3 per minute at full power, the Avalanche EQLED358 is capable of creating a impressive snowfall effect. The fluid consumption is approximately 540ml/min at 100% output. The unit can be controlled manually using the wired remote control or via DMX, making it suitable for a variety of applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI