APsystems 25A AC Connector Installation guide

Type
Installation guide

This manual is also suitable for

2018/1/15 Rev1.1
1
APsystems
8701 N. Mopac Expy, Ste 160, Austin, TX 78759
Tel : 844-666-7035
apsystems.com
25A AC Connector (EN,5-wire) Field Wiring
Installation Guide
(For USA)
Tools: Cross screwdriver, wire striper, solid wrench or monkey wrench.
Step 1. Verify the AC connector: Type is 25A AC Male Connector (EN,5-wire) or 25A
AC Female Connector (EN,5-wire).
Step 2. Wire Stripping
Wire gauge5x2.5mm²(14AWG) or 4x2.5mm² (14AWG~12AWG)
Cable OD10mm~13mm
Wire stripping size (mm ):Earth wire is supposed to be longer than Live wire and Neutral wire.
Step 3. Wiring cables to the AC connectors.
a. Set the parts on the cable according to the order of 1234.
25A AC Male Connector(EN,5-wire)
25A AC Female Connector(EN,5-wire)
4 Body
3 Seal body
1Nut
2Claw
2018/1/15 Rev1.1
2
APsystems
8701 N. Mopac Expy, Ste 160, Austin, TX 78759
Tel : 844-666-7035
apsystems.com
b. Crimp wires: the plastic core of connector is printed, please wire according to the print, ( If
the 4-wire cable can be empty),screw twisting torque
mN 1.0/8.0
.
c. Push Housing into Body until hear the the click sound.
d. Insert Seal and Clamp Finger into Body, then tighten the nut, torque
e. Installation of cable end female connector is the same as male connector.
25A AC Female Connector
Installation completed
Plastic Core
click
mN 5.0/0.4
  • Page 1 1
  • Page 2 2

APsystems 25A AC Connector Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI