APsystems 25A AC Connector User guide

  • Hello, I'm your assistant. I've reviewed the provided installation guide for the APsystems 25A AC Male and Female Connectors. The document outlines the steps for proper installation, including wire stripping, wiring the connectors, and tightening specifications. I'm ready to answer any questions you have about the guide or the installation process for these connectors.
  • What tools are needed for installation?
    What wire gauge should be used?
    What is the specified cable outer diameter (OD)?
    Is there a difference in stripping length for different wires?
2018/1/16 Rev1.0
1
25A AC Connector (EN,5-wire) Field Wiring
Installation Guide
(For Canada)
Tools: Cross screwdriver, wire striper, solid wrench or monkey wrench.
Step 1. Verify the AC connector: Type is 25A AC Male Connector (EN,5-wire) or 25A
AC Female Connector (EN,5-wire).
Step 2. Wire Stripping
Wire gauge5x2.5mm²(14AWG) or 4x2.5mm² (14AWG~12AWG)
Cable OD10mm~13mm
Wire stripping size (mm ):Earth wire is supposed to be longer than Live wire and Neutral wire.
Step 3. Wiring cables to the AC connectors.
a. Set the parts on the cable according to the order of 1234.
25A AC Male Connector(EN,5-wire)
25A AC Female Connector(EN,5-wire)
4 Body
3 Seal body
1Nut
2Claw
2018/1/16 Rev1.0
2
b. Crimp wires: the plastic core of connector is printed, please wire according to the print, ( If
the 4-wire cable can be empty),screw twisting torque
mN 1.0/8.0
.
c. Push Housing into Body until hear the the click sound.
d. Insert Seal and Clamp Finger into Body, then tighten the nut, torque
e. Installation of cable end female connector is the same as male connector.
25A AC Male Connector
Installation completed
Plastic Core
click
mN 5.0/0.4
/