FläktGroup F800 Operating instructions

Category
Above ground pool accessories
Type
Operating instructions
F800
OPERATION MANUAL
Table of Contents F800
2FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
1 Safety and User Instructions ......................................................... 3
1.1 Availability of the operation manual ................................................ 3
1.2 Scope of the operation manual ...................................................... 3
1.3 Symbols used ................................................................................. 3
1.4 Identification of safety instructions ................................................. 4
1.5 Safety-conscious work procedures ................................................. 5
1.6 Proper use ...................................................................................... 5
1.7 Modifications and changes ............................................................. 6
1.8 Spare parts ..................................................................................... 6
1.9 Disposal .......................................................................................... 6
1.10 Selection and qualification of personnel ....................................... 6
2 Technical Description ..................................................................... 7
2.1 Unit overview F800 ......................................................................... 7
2.2 F800 unit types: .............................................................................. 7
2.3 Accessories and Special Equipment .............................................. 8
2.4 Functional principle of the F800 ................................................... 10
2.5 Air ventilation operation, no dehumidification requirement ........... 11
2.6 Dehumidification Operation .......................................................... 11
2.7 Technical Specifications ............................................................... 12
3 Shipping and Storage ................................................................... 14
3.1 Delivery ........................................................................................ 14
3.2 Transport ...................................................................................... 14
3.3 Storage ......................................................................................... 15
4 Erect, Assemble and Connect ..................................................... 16
4.1 Positioning the unit ....................................................................... 16
4.2 Connect unit water-side ................................................................ 24
4.3 Electrical installation ..................................................................... 27
4.4 Assemble remote control (optionally) ........................................... 30
5 Commissioning and operation .................................................... 31
5.1 Requirements ............................................................................... 31
5.2 Commissioning ............................................................................. 31
5.3 F800 operation ............................................................................. 33
6 Maintenance, Cleaning and Troubleshooting ............................ 34
6.1 Maintenance ................................................................................. 34
6.2 Cleaning ....................................................................................... 34
6.3 Troubleshooting ............................................................................ 36
7 Disassembly and Disposal ........................................................... 37
7.1 Dismantling ................................................................................... 37
7.2 Disposal ........................................................................................ 37
8 EG Declaration of Conformity ...................................................... 38
F800 Safety and User Instructions
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications3
1 Safety and User Instructions
The F800 units are constructed using the state-of-the-art technology and according to
recognized safety regulations.
Use the unit when it is in a technically sound condition for the intended purpose observ-
ing current operation manual, taking safety aspects and potential hazards into account!
Otherwise failure to follow these instructions may result in death or injury to the user,
third persons or damage to the unit, connected units or other equipment! Have all faults
repaired by an authorized specialist without delay!
Consider the safety instructions provided by the manufacturers of individual compo-
nents!
1.1 Availability of the operation manual
This operation manual contains important instructions regarding safe and correct oper-
ation of the unit.
This operation manual applies to installation companies, operators, building techni-
cians, technical personnel or instructed persons as well as electricians.
This operation manual must be available at the location of the unit at all times. When
working on the equipment, observe all instructions and precautions in the current oper-
ation manual, in particular the chapter on safety.
1.2 Scope of the operation manual
This operation manual provides information about the following:
Shipping and storage
– Mounting
Installation and Electrical Connection
Commissioning and Maintenance
Disassembly and Disposal
1.3 Symbols used
The following symbols are used to highlight particular text sections in this operation
manual:
This symbol is used to indicate normal lists.
This symbol indicates handling instructions.
9This symbol indicates the result of an action.
NOTICE!
This symbol denotes additional instructions on using the unit.
RECYCLING!
This symbol is used to highlight instructions for the recycling of packaging material
and disused unit components, which must be separated depending on the material
type.
PROPER BOOTS REQUIRED!
This symbol points out that you must wear proper protective boots.
WEAR GLOVES!
This symbol points out that you must wear proper gloves.
Safety and User Instructions F800
4FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
1.4 Identification of safety instructions
To designate the safety instructions the following symbols and notices are provided in
appropriate places throughout this document:
DANGER OF ELECTRICAL CURRENT!
This symbol indicates a risk of electric shock when working on the equipment.
PERSONAL INJURY!
This section specifies procedures and precautions for the prevention of personal
injury.
WARNING: RISK OF ROTATING COMPONENTS!
This section specifies procedures and precautions for preventing personal injury as
a result of rotating unit parts.
DANGER DUE TO OVERHEAD LOADS!
This section specifies procedures and precautions for the prevention of personal
injury and damage to units through falling components.
DANGER OF HOT SURFACES!
This section specifies procedures and precautions for preventing personal injury due
to hot surfaces.
DANGER OF SCALDING!
This section specifies procedures and precautions for the prevention of personal
injury resulting from scalding by steam.
DANGER OF INFLAMMABLE MATERIALS!
This section specifies procedures and precautions for the prevention of personal
injury resulting from fire risk.
DANGER – SHARP CUTTING EDGES!
This section specifies procedures and precautions for preventing personal injury due
to cutting on thin metal fins.
ENVIRONMENTAL DAMAGE!
This section specifies procedures and precautions for preventing environmental
damage with reference to the valid national regulations on environmental protection.
DAMAGE TO THE UNIT!
This section specifies procedures and precautions regarding the prevention of
equipment damage.
F800 Safety and User Instructions
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications5
1.5 Safety-conscious work procedures
Observe the following instructions when carrying out installation, adjustment or repair
jobs:
When working within range of mains voltage:
For all kinds of work on open unit in operation:
Jobs on the unit can only be carried out if
all poles for the power supply are disconnected
the unit is secured to prevent inadvertent energising (also refer to "Electrical haz-
ard")
the heat exchanger has cooled down to reach ambient temperature
Upon completion of jobs on the unit ensure that
all protective devices are operating properly.
1.6 Proper use
The purpose of F800 units is to dehumidify, ventilate and heat air in indoor swim-
ming pools and wet areas as well as to heat and filter water for pools.
Proper use also includes observance of the operation manual and the inspection and
maintenance conditions stipulated by FläktGroup.
Improper use Any other (than the above-mentioned) application or use that goes beyond that
described as proper use is deemed as improper use. The manufacturer/supplier is not
liable for any damages arising from improper use. The user alone bears the risk.
Operating conditions:
Room temperature min. approx. 22 °C/max. 36 °C
Room air humidity min. 36 %/max. 60 % r.h.
Water quality Corrosion protection of installed unit components on the air side is ensured if the limit
values for chemicals in pool water as specified in VDI 2089 Sheet 2 "Water treatment
in swimming baths" and VDI 19643 are not exceeded.
Only indoor installation of units is allowed.
Recirculating air mode is possible
Mixed-air operation with outside-air rate (only in connection with an auxiliary PWW
coil and outgoing-air fan)
Direct installation, inderect installation
DANGER OF ELECTRICAL CURRENT!
Disconnect all electric power of the unit and ensure the power cannot be inadvert-
ently switched on, earth, short-circuit and block off all neighboring live parts. Non-
compliance can lead to death or serious injury.
DANGER – SHARP CUTTING EDGES!
No matter what kind of jobs are performed on the unit, there is always a risk of cuts
inflicted by thin sheet metal and heat exchanger fins. In particular, this aspect applies
when carrying out maintenance and cleaning work on the coil surfaces.
PERSONAL INJURY AND EQUIPMENT DAMAGE!
It is not allowed to operate the unit:
In areas subject to explosion risk,
in environment with conductive dust,
in environment with strong electromagnetic fields,
in environment with aggressive atmosphere that may attack plastics or cause cor-
rosion (especially in atmospheres where zinc is particularly susceptible to corro-
sion) or under conditions violating the requirements of the VDI 2089.
Safety and User Instructions F800
6FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
1.7 Modifications and changes
You are not allowed to change, add to or modify the unit in any way. Tampering with
the FläktGroup unit, its misapplication or modifications will invalidate the CE conformity
and void warranty.
1.8 Spare parts
Only original FläktGroup spare parts are allowed, since FläktGroup is not liable if third-
party spare parts are used.
1.9 Disposal
Dispose of main and operating supply materials as well as other components and fil-
ters according to their material type in a safe and environmentally-friendly manner, also
refer to chapter "Disassembly and Disposal" on page 37.
1.10 Selection and qualification of personnel
Ensure that every person working on the unit has read and understood entire operation
manual.
All jobs must only be carried out by qualified licensed staff or other individuals with
proper professional training and experience in the following areas:
Occupational health and safety regulations
Accident prevention regulations
Directives and recognized codes of practice
All skilled staff must be able to assess the entrusted work and must be able to recog-
nize and avoid all associated dangers.
F800 Technical Description
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications7
2 Technical Description
2.1 Unit overview F800
The closed cooling cycle of a F800 consists of a scroll compressor, water-cooled con-
denser (accessory), air-cooled condenser, expansion valve with injection-capillary
tubes and air cooler. The cooling cycle is filled with environmentally-friendly R407C
(see also Fig. 2-2: Refrigeration circuit).
Fig. 2-1: F800
2.2 F800 unit types:
Base type 1 (F8SG) Basic unit with white casing for placement and assembly in an indoor swimming
pool:
Dehumidification in recirculating air mode
Cooling cycle with completely hermetically sealed scroll compressor, completely
piped and filled with environmentally-friendly refrigerant
Completely wired internal electronics with all functions, including the safety chain to
protect installation components and generate protective extra-low voltage for the
humidity controller (accessory F8ZRG – see "Remote control" on page 8)
All materials in corrosion-resistant configuration for the atmosphere and water qual-
ity customary in swimming pools
Base type 2 F8BG
Like base type 1 with additional pool water condenser
A part of the recovered energy is returned to the pool water here, again increasing
the efficiency
Base type 3 F8PG
Like base type 1 with additional additional PWW heating register
The thermal output is increased by the additional PWW heating register. This is
absolutely necessary for the operation of the dehumidifier with outside-air rate
Base type 4 F8KG
Like base type 1 with additional pool water condenser and additional PWW heating
register
Unit types
without casing F8S, F8B, F8P, F8K
All base types can also be delivered without casing, e.g. for rear wall mounting
the G is omitted for the respective type designation
Technical Description F800
8FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
2.3 Accessories and special equipment
Remote control F8ZRG
Humidity controller as remote control with operation and malfunction indicator,
operating switch and setpoint setting
Operation with protective extra-low voltage from the basic unit
– Control/regulation
Additional switch box
(parallel operation) F8ZRK
For the parallel circuit from two F800s with own protective extra-low voltage supply
operated with a common humidity controller (see F8ZRG)
Tandem connection possible (2 and more)
Pool water pump F8ZBP
–self-priming
Corrosion-resistant version
230 V ~, 50 HZ
Power consumption 0.18 kW
Pump output 700 l/h – 20 kPa
Type designation: PY-2071.0741
Pool water
immersion thermostat F8ZBT
With V4A stainless steel immersion sensor to limit the pool water temperature
F800 Technical Description
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications9
Duct connector-piece
with flexible connection F8ZST
For the supply air for rear wall mounting
Unit rear wall painted F8ZHA
Painted in the color shade of the casing
Suitable for visible rear wall – e.g. for placement in front of a window
Adapter for extract-air
connection (air intake) F8ZAD2
For rear wall mounting on the basic unit
Air routing from the swimming pool to the adapter over on-site air ducts or air hoses
with round 180 mm connection
Extract fan
(built into the wall) F8ZAV
For units with outside-air connection and for placement in rooms which cannot be
supplied with outside air from windows or doors, or where offensive odours can be
expected
230 V ~, 2 stages
–Plastic
Self-acting sealing cap
Wall sleeve 160 mm long
Air flow rate 220 / 260 m3/h
2-stage speed control and voltage supply directly from the basic unit
Protection class IP 45
Max.operating temperature +40 °C
Outside air
connection fittings F8ZAA
Diameter 150 mm
For the operation of the basic unit with share fraction of fresh air
Use only with extract fan (F8ZAV) and additional PWW heating register
Technical Description F800
10 FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
Painted refrigeration
pipework F8ZKL
Improved corrosion protection with painted refrigeration circuit
Special paint finish
casing (RAL colors) F8ZSL
Spare filter set F8ZEF
2.4 Functional principle of the F800
The figure shows the refrigeration circuit with pool water condenser essentially consist-
ing of: scroll compressor (1), air-cooled condenser (4) and pool water condenser
(Option)(3), expansion valve (8) and evaporator or air- cooler (9). Refrigeration circuit
filled with refrigerant.
1: compressor
3: pool water
condenser (accessory)
4: air-cooled condenser
5: high-pressure monitor
6: schrader valve
7: dryer/collector
8: expansion valve
9: evaporator (air cooler)
10: anti-icing
protection
thermostat
11: low-pressure limiter
12: venting valve
13 pool water
connection R 1/2"
Fig. 2-2: Refrigeration circuit
The hall air is evacuated by the centrifugal fan and cooled over the air cooler.
Depending on the humidity, the temperature can drop below the dew point; the water
steam in the hall air condenses on the fins of the air cooler and collects in the conden-
sate tray. The water condensate drained off through a pipe.
The dehumidified and cooled air is then re-warmed and supplied to the indoor swim-
ming pool hall.
If connected to the pool water condenser, about 65% of the thermal output is returned
to the pool water and about 35% to the hall air.
12
4
6
3
3
11
9
10
8
7
13
F800 Technical Description
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications11
2.5 Air ventilation operation, no dehumidification requirement
As long as no dehumidification requirement is needed with the humidity switch in the
remote control, the F800 operates at low fan speed in ventilating/air circulation mode
in order to largely avoid wet corners and clouding of the windows.
2.6 Dehumidification operation
The dehumidification is switched on with the humidity switch in the remote control
whenever the inside air humidity rises above the preset setpoint. The high fan speed
and the compressor are then automatically taken into operation.
After the inside air humidity drops by about 5% rel. hum. below the preset setpoint, the
compressor is switched off (observe minimum standing and running period) and the
fan switched back to the low fan speed.
Technical Description F800
12 FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
2.7 Technical specifications
Technical data F800
Application range Private indoor pool Pool water surface up to 50 m2
Room air states (operating limits) min. approx. 22 °C / 40% rel. hum.
(h = 35 kJ/kg)
max. 36 °C / 60% rel. hum. (h = 94 kJ/
kg)
Capacity
Pool water condenser (PWC) = accessory 1) with PWC without PWC
Dehumidification capacity in recirculating air mode 2) 3.9 kg/h 3.4 kg/h
Heat capacity (surplus energy) 2)
(not to be taken into account for the computation of heat
requirements)
4.4 kW
(2.9 on the water)
4.6 kW
Fans
Air flow rate 1st speed/2. Speed 400/800 m3/h
External pressure drop 20 PA
Sound power level 61 dB(A)
Performance/current consumption of the fan motor 0.16/0.72 kW/A
Refrigeration circuit with PWC without PWC
Power/current consumption 1.55/7.3 kW/A 1.73/8.0
Compressor motor 2) maximum starting current 47 A
Connection data
Unit connected load/operating current 3) 2.8/13.7 kW/A
Operating voltage 230/1/50 V/Ph/Hz
On-site protection 16 A (slow blow)
Control/regulating voltage (SELV) 24 V (DC)
Unit protection type IP.X5
Hygrostat protection type IP.30
Air reheater (accessory)
Heating capacity at PWW 80/60 °C 4) 3.1/4.0 kW
Waterside resistance to flow 1.7 k/Pa
Dimensions/weight
Dimensions: length/height/depth 1660/795/290 mm
Weight (with maximum accessory furnishings) about 122 kg
Pool water pump (accessory) (type designation: PY-2071.0741)
Operating voltage 230 V/1~Ph 50 Hz
Pump output 700 l/h/20 kPa
Power consumption 0.18 kW
Connections (pressure and suction side) 1/2"
Geodetic delivery head (suction side) 2 m
Suction line length max 5 m
1) Volume flow of the pool water condenser max. 0.7 m3/h, water resistance of the pool water condenser 8.0 kPa
2) Pool water temperature 28 °C, room air state 30 °C/ 60 % rel.h.
F800 Technical Description
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications13
2.7.1 Unit dimensions with casing
1: installation opening
2: outside air connector
(accessory)
3: electrical connection
4: connection pool water
condenser R 1/2"
(accessory)
5: water condensate drain-
age
R 1/2" a
6: air discharge grille
7: air intake grille
8: discharge forwards
(e.g. for niche installation)
Fig. 2-3: Unit dimensions with casing
2.7.2 Unit dimensions without casing
Fig. 2-4: Unit dimensions without casing / For heat exchanger connections see Page 22
3) Max. power consumption including external components from the accessories program
4) Recirculating air inlet temperature 30°C and fan speed 1/2
Technical data F800
1658
1272190
110
150
2,75 190
2,75
13756
130
798,5
20
1002
768,5
400
150
34,5
289
30
180
429
71,5
89
6
7 21
6
8
3
4
8
5
45
1365,5
85
45
43,5
429
180
26
751
161,51268
270
744,5
229,5
264
67,5
67,5
98
4
Shipping and Storage F800
14 FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
3 Shipping and Storage
3.1 Delivery
The units are delivered standing in cardboard packaging on pallets.
When the unit is delivered, check that the shipment is correct according to the
despatch note, and also check for completeness.
What steps should you
should take in the event of
shipping damage?
The exterior of the packaging is damaged
1 Unpack the equipment in the presence of the lorry driver and have him confirm the
damage on the shipping order.
2 Inform the FläktGroup Sales Company immediately.
Exterior packaging is O.K., contents are damaged.
1 Once you have established the extent of the damage, report the damage to the
FläktGroup Sales Company in writing.
2 Take photographs of the damaged parts.
3 Possible shipping damage must be reported no later than 4 days after delivery.
It will not be possible to process claims if the above-mentioned points are not fulfilled.
In both cases, consult the FläktGroup Sales Company installing the units.
3.2 Transport
For safety reasons, wear gloves and safety footwear when lifting or transporting the
unit.
NOTICE!
Consider instructions relating to the procedures in case of shipping damage provided
on the unit packaging or in despatch documents!
NOTICE!
Transport the unit only in its original packing.
Only remove the original packaging just before installation.
PERSONAL INJURY!
Conduct the transportation with at least three persons in order to avoid injuries or
damages.
The weight with maximum accessories can be about 122 kg!
DAMAGE TO THE UNIT!
The unit may be not tipped more than 45° when being transported to its installa-
tion site.
The unit may not be transported in a lying position.
F800 Shipping and Storage
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications15
At the installation site: Remove outer packaging.
Lift the unit only on the pallet. Do not lift the unit by the
rounded lateral casing. (Fig. 3-1)
When using lifting and transport vehicles, employ only tech-
nical aids with sufficient loading capacity > 135 kg.
For proper transportation of the unit, remove the trim panels and
grille of the unit (see “Erect, assemble and connect” on page
16).
Only lift the unit on the base frame.
9Lift the unit with at least 3 persons. The weight is consider-
ably greater on the side with the switch box (refrigeration
system with compressor)!
3.3 Storage
Permissible storage conditions for non-installed units
Air temperature -10 °C to 50 °C
Air humidity 50 to 85 % r.h., no condensation
DAMAGE TO THE UNIT!
Never lift the unit completely off the pallet. Only grip the unit by the base frame,
not by the lateral casing or the grille. There is risk of damage.
Fig. 3-1
Fig. 3-2
NOTICE!
F800 may only be stored in weather-protected rooms
Observe the permissible storage conditions.
Remove the original packaging only just before installation.
If the unit is stored for a period of time before installation or commissioning, pro-
tect it from damage through elements, build-up of dust and dirt!
Prior to commissioning, take appropriate measures to protect units without pack-
aging against build-up of dust and dirt. Ensure conditions when condensate can
not form below packaging supplied by others (consider relevant clearance
between the packaging and casing).
The unit may not be stored lying on its side.
Erect, assemble and connect F800
16 FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
4 Erect, assemble and connect
4.1 Positioning the unit
The F800 can be installed to dehumidify indoor swimming pools or other damp areas,
directly in the swimming pool hall or damp room or in ancillary rooms (rear-wall instal-
lation).
When setting up the unit, the good air circulation should provide
a homogenous temperature and humidity profile.
Fig. 4-1: Setting up in swimming pool/damp rooms
For installation with pool wa-
ter pump: Only set up the pool water pump in dry and frost-proof surroundings.
Ensure sufficient fresh-air supply to avoid inadmissible warming of the drive motor.
The pump can only be installed horizontally.
Improper installation or opening the pump will result in loss of warranty service.
To install the unit, proceed as follows:
If necessary, remove outer packaging.
Grip into the air intake grille, shove it upwards, tip down and remove.
Fig. 4-2
Unscrew both plastic screws at the lower sheet.
Fig. 4-3
Here you will find information on how to assemble and install the unit.
Mount and install exclusively by qualified staff. Qualified licensed staff or other per-
sons with proper professional training must be experienced in the relevant accident
prevention regulations, as well as other generally recognized safety and occupa-
tional health codes.
NOTICE!
Observe the minimum distances between unit and
pool edge according to VDE without fail.
F800 Erect, assemble and connect
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications17
Tilt the support sheet (for the grille) forwards and push it out.
Fig. 4-4
Push the lateral casing forwards and remove.
Fig. 4-5
Take the unit off the pallet and set it up at the installation site.
Only grip the unit on the base frame! The weight is considerably greater on the
switch box side (refrigeration system with compressor)!
Fig. 4-6
Set the F800 only on a level and fortified surface.
For additional sound insulation on the building-side, please
observe: underlay base frame on the whole surface, max.
pressing 1 mm.
4.1.1 Move the air discharge forwards (alternatively)
The F800 is standardly delivered with the air discharge upwards.
In order not to hamper the air outlet e.g. by installing a unit in a niche, the air discharge
can be moved forwards.
Fig. 4-7: Foundation
Rubber mat (building-side)
NOTICE!
To reduce noise, set the unit without fail on a
sound-absorbing surface.
This reduces the structure-borne noise transmis-
sion to the rest of the building.
Erect, assemble and connect F800
18 FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
For this modification, proceed as follows:
Unscrew both plastic screws on the lower sheet as de-
scribed in the Fig. 4-3 on page 16.
Push the lateral casing forwards and remove.
Fig. 4-8
Unscrew both screws (1) of the upper cover.
Tilt the cover forwards and remove.
Remove air discharge grille (2)
Remove front sheet material cover (3)
Fig. 4-9
Remove the plastic caps of the screws.
Unscrew screws of the internal covering.
Fig. 4-10
Unscrew upper sheet metal cover.
Lay internal covering upwards above the previous air dis-
charge and assemble with the screws.
Set the plastic cap on the screws.
Fig. 4-11
2
1
3
F800 Erect, assemble and connect
FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications19
Once again attach covering panels and bolt them together with
the unit:
Attach front sheet metal cover (1).
Insert grille (2).
Place and bolt together upper sheet metal cover (3 and 4)
Once again push on lateral casing (5).
Fig. 4-12
4.1.2 Two units in one plant
Should two F800 be required for reaching the required dehumidification efficiency,
these could be controlled and monitored in parallel by a common remote control. The
additional switch box type F8ZRK should be installed outside of the protected zone 1
and 2 (3.50 m from the pool edge), preferably outside of the swimming pool.
Fig. 4-13: F8ZRK
Electrical connection, see "Electrical installation" on page 27
4.1.3 Mixed-air operation
An improvement of the room climatic conditions can be achieved by the connection of
an outside-air connector.
1
2
3
4
5
NOTICE!
Units with an outside air connection must be installed at the outside wall, since addi-
tional ducts could reduce the outside air volume flow.
Minimum distances between unit and pool edge according to VDE must be observed
without fail.
Furthermore, these units must be equipped with a PWW reheater coil (accessory)
and an outgoing-air fan (see Fig. 4-21: Outgoing-air fan on page 22) must be pro-
vided (accessory).
NOTE
In this case, a PWW additional heating register (accessory) is required, to ensure
that the supply-air temperature is not less than the hall-air temperature (avoid-
ance of air draughts).
An air filter and equipment for the air flow rate setting must be provided building-
side and be mounted in the outside air connection! Otherwise the unit can
become soiled and the performance impaired.
Erect, assemble and connect F800
20 FläktGroup DC-2013-0105-DE 2018-05/R5 • Subject to modifications
Prepare the unit as follows:
Open or cut the outside air connection. Be sure
to hold the cut-out material tightly to avoid it fall-
ing back into the interior of the unit! Otherwise
the unit must be opened in order to remove the
cut-out material.
For units with rear wall mounting, the outside air
connection is mounted in front of the unit (see
“Set up in ancillary rooms (rear wall assembly)”
on page 20.
Fig. 4-14 Screw on the outside-air connectors (accesso-
ry) with 2 screws.
Connect air connection.
The installed thermostatic valve regulates the hot
water flow rate.
The heater supply is directly connected at the
valve (R 1/2"i) and the heater return line at the
heating register connection (R 1/2"i) (left unit side).
Fig. 4-15: Mixed-air operation
1: Outside-air connection
2: Heater water connection (supply) R1/2" (accessory)
3: Heater water connection (return line) R1/2" (accessory)
4.1.4 Set up in ancillary rooms (rear wall assembly)
Units to be installed in ancillary are delivered without casing.
The ambient temperature must be at least 20° C to avoid temperature shortfalls in the
unit and air ducts.
Rear-wall units must be set up in such a way, that the unit can be connected with short
duct pieces. The maximum total static pressure is 20 Pa. The pre-assembled flexible
connection for the supply air connection can be delivered as an accessory (see
“Adapter for extract-air connection for setting up in ancillary rooms” on page 21).
The unit is equipped with an adapter for connection to on-site exhaust air lines (e.g.
flexible air hoses). This is mounted before the air intake at the lower part of the unit
(see “Adapter for extract-air connection for setting up in ancillary rooms” on page 21).
Connectors with a diameter of 180 mm are provided for the connection of the hoses.
1002
130
13556
Ø150
240
127
571
601
714
400
161708
1
1
13
2
a
b
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

FläktGroup F800 Operating instructions

Category
Above ground pool accessories
Type
Operating instructions