  • Hello! I am an AI chatbot trained to assist you with the Abicor Binzel Welding Torch ABIMIG® Shipyard & Offshore Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
T E C H N O L O G Y F O R T H E W E L D E R ´ S W O R L D .
www.binzel-abicor.com
1
DE Beipackzettel / EN Instruction leaflet
DE Adapter PP plus ABIMIG AT LW/
EN Adapter PP plus ABIMIG AT LW
DE Montageanleitung
1 Haltenippel (6) in Brennerkörper (7) einfügen.
2 Adapterkörper (5) so anlegen, dass die Stifte in die vorgesehenen
Bohrungen passen.
3 Adapterkörper (5) mit Befestigungshülse (4) an den Brennerkörper (7)
schrauben.
4 Befestigungshülse (4) mit einem Schlüssel SW 27 anziehen.
5 Isolierhülse (2) über Befestigungshülse (4) schieben und mit
Halteschraube (3) fixieren.
.
Der Brennerhals ABIMIG (1) kann nun in acht verschiedenen Positionen
montiert werden.
1 Brennerhals ABIMIG
2 Isolierhülse
3 Halteschraube
4 Befestigungshülse
5 Adapterkörper
6 Haltenippel
7 Brennerkörper
Abb. 1 Übersicht
1234 5 6 7
a
HINWEIS
Die Gewindebohrung der Isolierhülse (2) muss möglichst senkrecht zur
Schlüsselfläche (a) der Befestigungshülse (4) liegen.
EN 2
Adapter PP plus
EN Mounting Instructions
1 Introduce holding nipple (6) into torch body (7).
2 Put adapter body (5) such that the pins fit into the provided bores.
3 Screw adapter body (5) with fastening sleeve (4) to the torch body (7).
4 Tighten fastening sleeve (4) using spanner SW 27.
5 Slide insulating sleeve (2) over fastening sleeve (4) and fix using locking
screw (3).
.
The torch neck ABIMIG (1) can be now mounted in eight different positions.
1 Torch neck ABIMIG
2 Insulating sleeve
3 Locking screw
4 Fastening sleeve
5 Adapter body
6 Holding nipple
7 Torch body
Fig. 1 Overview
1234 5 6 7
a
NOTICE
The threaded bore of the insulating sleeve (2) must be positioned as
vertically as possible to the spanner flat (a) of the fastening sleeve (4).