Door Sensor Alarm Host Using Method:
Press and hold the button for 2 seconds to enter programming
mode.
When all 4 LED lights are lit, the device is ready for remote controls to
be added.
Press any button on a remote control.
Lights will flash and host will beep twice.
Press and release the button to cycle through the zone numbers.
(See note below for which light indicator is which zone)
To program auxiliary devices onto a zone, activate them like you
would to set the alarm off.
Light will flash and host will beep twice.
To exit programming mode, press and release the button or wait 20
seconds without any operation.
Note:
From top to bottom, the first indicator light is the first zone, the second
indicator light is second zone, the third indicator light is the third zone, the
fourth indicator light is the fourth zone.
Important information:
If the alarm host beeps once when attempting to add auxiliary sensor, that
sensor is already programmed into the device. If all indicator lights flash 3
times it means the Fortress Safeguard is full.
Note:
The Safeguard can hold 10 sensors and 20 remote controls.