WEG CFW500 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the WEG CFW500 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
RS485-B Communication
Plug-in Module
Módulo Plug-in
Comunicación RS485-B
Módulo Plug-in
Comunicação RS485-B
CFW500
Installation, Configuration and Operation Guide
Guía de Instalación, Configuración y Operación
Guia de Instalação, Configuração e Operação
Motors | Automation | Energy | Transmission & Distribution | Coatings
Summary / Índice
English
EspañolPortuguês
1 SAFETY INFORMATION ...............................5
1.1 SAFETY WARNINGS ...................................5
1.2 PRELIMINARY RECOMMENDATIONS .......5
2 GENERAL INFORMATION ...........................5
3 CONTENTS OF THE PACKAGE ...................6
4 ACCESSORY INSTALLATION ....................6
5 SETTINGS ...................................................... 7
1 INFORMACIONES DE SEGURIDAD .........11
1.1 AVISOS DE SEGURIDAD ........................... 11
1.2 RECOMENDACIONES PRELIMINARES ....11
2 INFORMACIONES GENERALES .............. 11
3 CONTENIDO DEL EMBALAJE .................12
4 INSTALACIÓN DEL ACCESORIO .............12
5 CONFIGURACIONES ..................................13
1 INFORMAÇÕES DE SEGURANÇA ............ 17
1.1 AVISOS DE SEGURANÇA ........................ 17
1.2 RECOMENDAÇÕES PRELIMINARES ....... 17
2 INFORMÕES GERAIS ..........................17
3 CONTEÚDO DA EMBALAGEM .................18
4 INSTALAÇÃO DO ACESRIO ................18
5 CONFIGURAÇÕES......................................19
APPENDIX A – FIGURES ...............................23
ANEXO A – FIGURAS .....................................23
RS485-B Communication Plug-in Module
English
CFW500 | 5
1 SAFETY INFORMATION
1.1 SAFETY WARNINGS
NOTE!
Only use the CFW500-CRS485-B or
CFW500-CRS485-B-PNP Plug-in
Module in CFW500 WEG inverters.
We recommend reading the CFW500
user’s manual before installing or
operating this accessory.
This guide contains important
information for the correct understanding
and proper operation of this module.
1.2 PRELIMINARY RECOMMENDATIONS
ATTENTION!
Always disconnect the general
power supply before connecting or
disconnecting the accessories of the
frequency inverter CFW500.
Wait for at least 10 minutes to
guarantee complete de-energization
of the inverter.
2 GENERAL INFORMATION
This guide shows how tho install, configure and operate
the CFW500-CRS485-B or CFW500-CRS485-B-PNP
Plug-in Module.
NOTE!
The CFW500-CRS485-B-PNP
accessory must only be used with
the main software version equal to
or above the version V2.06 for the
CFW500, 1.85 for the CFW501 or
version V2.00 for the MW500.
RS485-B Communication Plug-in Module
English
6 | CFW500
3 CONTENTS OF THE PACKAGE
When receiving the product, check if this package
contains:
Accessory in anti-static packaging.
Installation, configuration and operation guide.
4 ACCESSORY INSTALLATION
The accessory is easily installed or replaced. For correct
installation of the accessory execute the following steps:
Step 1: With the inverter power supply off, remove the
front cover of the Inverter (figure A.1 (a)).
Step 2: Remove the accessory (connected plug-in
module) if any, as in figure A.1 (a).
Step 3: Fit and press the accessory to be installed as
indicated in figure A.1 (b) and then assemble the front
cover of the inverter.
Step 4: Power up the inverter and check if parameter
P0027 shows value 9 (P0027 = 9, for CFW500-CRS485-B)
or the value 15 (P0027 = 15, for CFW500-CRS485-B-PNP).
If this information is not true, check if the module used is
actually the CFW500-CRS485-B or CFW500-CRS485-B-
PNP and repeat steps 1-4.
RS485-B Communication Plug-in Module
English
CFW500 | 7
5 SETTINGS
The control connections (analogical input / output, digital
inputs / outputs and RS485 interface) must be performed
as shown in table 1 and figure A.1 (a) and figure A.1 (b).
Table 1: Signals of control connector
Connector Description
Superior Terminal
1 DO1-RL-NO
Digital output 1
(NO contact of relay 1)
3 DO1-RL-C
Digital output 1
(common point of relay 1)
5 DO1-RL-NC
Digital output 1
(NC contact of relay 1)
7 DO3-RL-NO
Digital output 3
(NO contact of relay 2)
9 DO3-RL-C
Digital output 3
(common point of relay 2)
11 DO3-RL-NC
Digital output 3
(NC contact of relay 2)
13 NC Not connected
15 +24 V +24 Vdc Power suply
17 DI1 Digital input 1
19 DI2 Digita l input 2
21 DI3 Digital input 3
23 DI4 Digital input 4
Inferior Terminal
2 AO1 Analogical output 1
4 GND Reference 0 V
6 AI1 Analogical input 1
8 +10 V
Reference +10 Vdc for
potentiometer
10 DO2-TR Digital output 2 (transistor)
12 RS485 - A1(-) RS485 (Terminal A1(-))
14 RS485 - B1(+) RS485 (Terminal B1(+))
16 GND1 GND 1 (RS485)
18 AI2 Analogical input 2
20 RS485 - A2(-) RS485 (Terminal A2(-))
22 RS485 - B2(+) RS485 (Terminal B2(+))
24 GND2 GND 2 (RS485)
RS485-B Communication Plug-in Module
English
8 | CFW500
AI1
AO1
GND
+10 V
DO2-T R
R
rpm
GND 1 (RS485)
GND 2 (RS485)
RS485 - B1(+)
RS485 - B2(+)
+24 V
+24 V
NC
DO1-RL -NO
DO3-RL -NO
DO1-RL -C
DO3-RL -C
DO1-RL -NC
DO3-RL -NC
DI1
DI2
DI3
DI4
RS485 - A1(-)
RS485 - A2(-)
≥5 kΩ
AI2
(a) Control connector signals to the
CFW500-CRS485-B module
AI1
AO1
GND
+10 V
DO2-T R
R
rpm
GND 1 (RS485)
RS485 - B1(+)
RS485 - B2(+)
GND 2 (RS485)
+24 V
NC
DO1-RL -NO
DO3-RL -NO
DO1-RL -C
DO3-RL -C
DO1-RL -NC
DO3-RL -NC
DI1
+24 V
DI2
DI3
DI4
RS485 - A1(-)
RS485 - A2(-)
≥5 kΩ
AI2
(b) Control connector signals to the
CFW500-CRS485-B-PNP module
Figure 1: (a) and (b) Control connector signals
RS485-B Communication Plug-in Module
English
CFW500 | 9
NOTE!
For the CFW500-CRS485-B-PNP module,
the digital inputs are fixed at active high
(P0271 = 8). It is not possible to set P0271
different from 8.
The location of the DIP-switches for selecting the type
of analog input and output signal and termination of
the RS485 line can be better visualized in figure A.2.
To use the analog inputs and/ or outputs with signal in
current, switch S1 and related parameters must be set as
indicated in table 2 . For further details about the control
connections see chapter 3 - Installation and Connection
of the CFW500 user's manual.
Table 2: Settings of switches to select the type of analog
input and output signal of the CRS485-B
Input /
Output
Signal
Setting of
Switch S1
Range of
Signal
Parameter
Settings
AI1
Voltage S1.1 = OFF
0...10 V P0233 = 0 or 2
Current S1.1 = ON
0...20 mA P0233 = 0 or 2
4...20 mA P0233 = 1 or 3
AI2
Voltage S2.1 = OFF
0...10 V P0238 = 0 or 2
Current S2.1 = ON
0...20 mA P0238 = 0 or 2
4...20 m A P0238 = 1 or 3
AO1
Voltage S1.2 = ON
0...10 V P0253 = 0 or 3
Current S1.2 = OFF
0...20 mA P0253 = 1 or 4
4...20 mA P0253 = 2 or 5
NOTE!
Configurations for activation of RS485 (1):
S1.3 = ON and S1.4 = ON: RS485
termination ON
S1.3 = OFF and S1.4 = OFF: RS485
termination OFF
Any other combinations of the switches
are not allowed
RS485-B Communication Plug-in Module
English
10 | CFW500
NOTE!
Configurations for activation of
RS485(2):
S2.3 = ON and S2.4 = ON: RS485(2)
termination ON
S2.3 = OFF and S2.4 = OFF: RS485(2)
termination OFF
Any other combinations of the switches
are not allowed
This module has a connector (figure A.2) to enable the
use of the Flash Memory Module (CFW500-MMF), which
allows data transfer between inverters. For further details
on this accessory, refer to the installation, configuration
and operation guide of the CFW500-MMF.
/