IndoorUnit
ForceCoolingOperation
Whentheremotecontrolcannotbeusedor
forrepairingandtesting,pleaseusethis
button.
PowerSwitchON/OFF
OperationIndicationLamps
Power(green)
Timer(orange)
Lightsupinoperation;
BlinksduringHotStart
operationand
determiningAuto
Operationmode
OperationMode
Cooling/Heating/SoftDry/AutoOperation
TimeDelaySafetyControl
Theunitwillrestartoperationin3-4
minutesaftereachpause.
Keeppressingthisbuttonfor5secondstostart
theforcecoolingoperation.
AutoSwitch
Button
Airquality
Green
Orange
Red
Anti-freezingControlfortheEvaporator
CoolingorSoftDryOperation
WarmBootingControl
Indoorfanstartsrunningwhenindoor
pipingreaches19orabove.temperature ℃
High,Med+,Med,Med-,Low
AutoFanSpeed
IndoorFanSpeedControl
AutomaticAirflowDirectionControl
Thelouverautomaticallyswingsupanddown
FiveManualAirflowDirectionControl
AirflowDirectionControl
DelayedOn-timerControl
Forcoolingorsoftdrymode,theunit
starts15minutesbeforethesettimewith
theremotecontrol,butforheatingmode
30minutesbeforethesettime.
ForceHeatingOperation
Keeppressingthisbuttonfor8secondstostart
theforceheatingoperation.
SignalReceivingSound
Keeppressingthisbuttonfor16secondstoturn
offorturnonthesignalreceivingsound
or
H14AbnormalityDetectionMode.
LightupinTimerSetting.
BlinksinSelfDiagnosisControl
AutomaticRestartControl
Operationisrestartedafterpowerfailure
atprevioussettingmode.
DifferentRemoteControllingSetting
Keeppressingthisbuttonfor11tochange
differentremotecontrollingsetting(AB)
Mode.
Featuremode
Powerful
Quiet
CS-RE9GKE/CU-RE9GKE/CS-RE12GKE/CU-RE12GKE