Panasonic CS-UE12JKE Datasheet

Category
Split-system air conditioners
Type
Datasheet

This manual is also suitable for

© Panasonic Home Appliances Air-Conditioning
(Guangzhou) Co., Ltd. 2008. Unauthorized copying
and distribution is a violation of law.
Order No: PHA-AG0903005C2
Indoor Unit Outdoor Unit
CS-UE9JKE
CS-UE12JKE
CU-UE9JKE
CU-UE12JKE
TABLE OF CONTENTS
1. Safety Precautions.............................................3
2. Specification.......................................................5
2.1 CS-UE9JKE CU-UE9JKE ............................5
2.2 CS-UE12JKE CU-UE12JKE ........................7
3.
Features ..............................................................9
4. Location of Controls and Components .........10
4.1 Indoor Unit..................................................10
4.2 Outdoor Unit...............................................10
4.3 Remote Control..........................................10
5. Dimensions.......................................................11
5.1 Indoor Unit..................................................11
5.2 Outdoor Unit...............................................13
6. Refrigeration Cycle Diagram...........................14
7. Block Diagram..................................................15
8. Wiring Connection Diagram............................16
8.1
CS-UE9JKE CU-UE9JKE ..........................18
8.2 CS-UE12JKE CU-UE12JKE ......................19
9.
Installation Instruction.....................................18
9.1 Select the Best Location ............................18
9.2 Indoor Unit..................................................19
9.3 Outdoor Unit...............................................21
10. Service Mode....................................................24
10.1 Auto OFF/ON Button..................................24
10.2 Select Remote Control Transmission Code24
10.3 Operate and Display of Remote Control....25
11. Operation Control.............................................27
11.1 Basic Function............................................27
11.2 Indoor Fan Motor Operation.......................28
11.3 Outdoor Fan Motor Operation....................28
12. Protection control ............................................31
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.
WARNING
2
12.1
Protection Control For All Operations.........31
12.2 Protection Control For Cooling and Soft Dry
Operation....................................................32
12.3 Outdoor Air Temperature Control...............33
13. Troubleshooting Guide....................................35
13.1 Refrigeration Cycle System........................35
13.2 Break Down self Diagnosis Function..........35
14.
Disassembly and Assembly Instructions......38
15. Exploded View and Replacement Pars List...41
15.1 Indoor Unit..................................................41
15.2 Outdoor Unit...............................................43
3
CAUTION
WARNING
WARNING
1. Safety Precautions
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the
power plug and main circuit for the model installed.
The caution items stated here must be followed because these important contents are related to safety. The
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction
will cause harm or damage, and the seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury
This indication shows the possibility of causing injury or damage to properties.
The items to be followed are classified by the symbols:
Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation,
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for
future reference.
1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage,
electrical shock or fire.
2. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical
shock or fire.
3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water
leakage, fire or electrical shock.
4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or
installation is not properly done, the set will drop and cause injury.
5. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise
building, child may climb up to outdoor unit and cross over the handrail and causing accident.
6. For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent
circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will
cause electrical shock or fire.
7. This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual
Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation
breakdown.
8. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning
rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown.
9. Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the
cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up
or fire at the connection.
10. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed
perfectly, it will cause fire or electrical shock.
11. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into
refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion
and injury.
12. Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock.
13. Do not modify the length of the power supply cord or use extension cord, and do not share the single outlet with other
electrical appliances. Otherwise, it will cause fire or electrical shock.
14. • For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same
may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use
only R410A materials.
• Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm
• It is desirable that the amount of residual oil is less than 40 mg/10 m.
15. During installation, before run the compressor, confirm the refrigeration pipes are fixed. Operation of compressor
without fixing the piping, setting the 2 way valve and 3-way valve at open condition, a burst may occur and cause
injury.
16. During pump down operation, stop the compressor before remove the refrigeration piping. When remove piping while
2-way valve, 3 way valve at open condition, burst may occur and cause injury.
Symbol with white background denotes item that is PROHIBITED from doing.
Symbol with dark background denotes item that must be carried out.
4
CAUTION
17. After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the
refrigerant contacts with fire.
18. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with
fire.
19. Recommended installation height for indoor unit shall be at least 2.5 m.
20. The appliance shall be installed in accordance with national wiring regulations.
21. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
23. Do not modify the machine, part, material during repairing service.
24. Must not use other parts except original parts describe in catalog and manual.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room
and damage the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long
period, the flare may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminums fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Power supply connection to the air conditioner.
Connect the power supply cord of the air conditioner to the mains using one of the following methods.
Power supply point should be in easily accessible place for power disconnection in case of emergency.
In some countries, permanent connection of this air conditioner to the power supply is prohibited.
1) Power supply connection to the receptacle using a power plug.
Use an approved 15/16A power plug with earth pin for the connection to the receptacle.
2) Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for
the permanent connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
7. Do not release refrigerant.
Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts.
Take care of the liquid refrigerant, it may cause frostbite.
8. Installation and service work.
It may need two people to carry out the installation and service work.
9. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
10. Do not sit ot step on the unit, you may fall down accidentally.
11. Do not touch the sharp aluminium fin, sharp parts may cause injury.
12. Thermal fuse specification for indoor unit: 250V 3.15A T3.15AL; outdoor unit: 205V 3.15A T3.15AL,205V 20A T20AL.
5
2. Specification
2.1 CS-UE9JKE CU-UE9JKE
Item Unit Indoor Unit Outdoor Unit
kW 2.50(0.90~3.00) Capacity
BTU/h 8530(3070~10230)
W/W 3.33(4.73~3.00) EER
BTU/hW 11.37(16.15~10.23)
dB(A) Hi: 42 Lo: 27 QLo: 22 Hi: 46
COOLING
Noise Level
Power level dB 53 59
kW 3.30(0.90~4.00) Capacity
BTU/h 11260(3070~13650)
W/W 3.66(4.09~3.33) COP
BTU/hW 12.51(13.95~11.37)
dB(A) Hi: 42 Lo: 27 QLo: 25 Hi: 47
HEATING
Noise Level
Power level dB 53 60
l/h 1.4 Moisture Removal
(pt/h) 2.4
Lo m
3
/m (ft
3
/m) 6.15(232) -
Me m
3
/m (ft
3
/m) 7.93(300) -
Air Volume
Hi m
3
/m (ft
3
/m) 10.08 (381) 28.9(1020)
Refrigerant Control Device - Capillary Tube
Refrigerant Oil (Charged) cm
3
- RB68A or Freol Alpha68M
Refrigerant (Charged) R410A kg (oz) - 0.78 (27.5)
Height mm (inch) 250 (9-27/32) 540 (21-1/4)
Width mm (inch) 770 (30-5/16) 780 (30-23/32)
Dimension
Depth mm (inch) 205 (8-1/16) 289 (11-3/8)
Net Weight kg (lbs) 7.0 28 (62)
Gas mm (inch) 9.52 (3/8) Pipe
Diameter
Liquid mm (inch) 6.35 (1/4)
Pipe Length m (ft) 3 (9.8) - 15(49.2)
Height Difference m (ft) 5 (16.4)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigerant Charge Less m (ft) 7.5 (24.6)
Inner diameter mm 14 - Drain Hose
Length mm 500 -
Type - Rotary
Motor Type - Induction (6-poles)
Compressor
Rated Output W - 750
Type Cross-Flow Fan Propeller Fan
Material AS PP
Motor Type Induction (8-poles) Induction (6-poles)
Input power W - -
Output power W 30 15
Lo rpm 830 -
Me rpm 1070 -
Fan
Fan
Speed
Hi rpm 1360 750
Fin material Aluminium (Pre Coated) Aluminum ( Pre Coated)
Fin type Slit Fin Slit Fin
Row x stage x FPI 2 x 12 x 18 1 x 24 x 17
Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4 709 x 504 x 18.2
Material P.P.HONEY COMB - Air Filter
Type
Style One-Touch -
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F
Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (80.6°F Dry Bulb) and outdoor air
temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
6
Item Unit
φ
Single
V 230
Power Source (Phase, Voltage, Cycle)
Hz 50
Input Power COOLING W 750(190~1000)
HEATING W 900(220~1200)
Starting Current A 4.10
Running Current COOLING A 3.60
HEATING A 4.10
Maximum Current A 5.50
Power Factor COOLING % 90
HEATING % 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Number of core 3 (1.5mm) Power Cord
Length m 1.3
Thermostat Electronic Control
Protection Device Electronic Control
Note
z Specification is subject to change without prior notice for further improvement.
z Operational temperature range:
Indoor Outdoor
Temperature °C
* DBT *WBT *DBT *WBT
Maximum 32 23 43 26
COOLING
Minimum 16 11 16 11
Maximum 30 - 24 18
HEATING
Minimum 16 - -5 -6
NOTICE: This model is not suitable for 24 hours non-stopping operation in heating mode below -5°C. If this model
is used out of above conditions, the outdoor unit might be frozen up and stop operation for protection
control.
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
7
2.2 CS-UE12JKE CU-UE12JKE
Item Unit Indoor Unit Outdoor Unit
kW 3.50(0.90~3.90) Capacity
BTU/h 11940(3070~13300)
W/W 3.30(5.29~3.25) EER
BTU/hW 11.26(18.06~11.08)
dB(A) Hi: 42 Lo: 30 QLo: 22 Hi: 48
COOLING
Noise Level
Power level dB Hi: 53 Lo: - Hi: 61
kW 4.25(0.90~4.70) Capacity
BTU/h 14490(3070~16030)
W/W 3.63(6.00~3.56) COP
BTU/hW 12.38(20.47~12.14)
dB(A) Hi: 42 Lo: 33 QLo: 25 Hi: 50
HEATING
Noise Level
Power level dB Hi: 53 Lo: - Hi: 63
l/h 2.0 Moisture Removal
(pt/h) 3.5
Lo m
3
/m (ft
3
/m) 8.1(285) -
Me m
3
/m (ft
3
/m) 9.9(349) -
Air Volume
Hi m
3
/m (ft
3
/m) 11.7 (413) 30.5 (1076)
Refrigerant Control Device - Capillary Tube
Refrigerant Oil (Charged) cm
3
- RB68A or Freol Alpha68M
Refrigerant (Charged) R410A kg (oz) - 0.97 (34.2)
Height mm (inch) 280 (11-1/32) 540 (21-1/4)
Width mm (inch) 799 (31-15/32) 780(30-23/32)
Dimension
Depth mm (inch) 183 (7-13/64) 289 (11-3/8)
Net Weight kg (lbs) 8.5 (19) 30 (66)
Gas mm (inch) 9.52 (3/8) Pipe
Diameter
Liquid mm (inch) 6.35 (1/4)
Pipe Length m (ft) 3 (9.8) - 15 (49.2)
Height Difference m (ft) 5 (16.4)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigerant Charge Less m (ft) 7.5 (24.6)
Inner diameter mm 14 - Drain Hose
Length mm 500 -
Type - Rotary
Motor Type - Induction (6-poles)
Compressor
Rated Output W - 900
Type Cross-Flow Fan Propeller Fan
Material AS PP
Motor Type Induction (8-poles) Induction (6-poles)
Input power W - -
Output power W 30 25
Lo (Cool) rpm 940 -
Me (Cool) rpm 1160 -
Fan
Fan
Speed
Hi (Cool) rpm 1370 870
Fin material Aluminum (Pre Coated) Aluminum (Pre Coated)
Fin type Slit Fin Slit Fin
Row x stage x FPI 2 x 15 x 20 2 x 24 x 17
Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4 709 x 540 x 36.4
Material P.P.HONEY.COMP - Air Filter
Type
Style One-Touch -
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F
Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (80.6°F Dry Bulb) and outdoor air
temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
8
Item Unit
Single
V 230
Power Source (Phase, Voltage,
Cycle)
Hz 50
Input Power COOLING W 1060(170~1200)
HEATING W 1170(150~1320)
Starting Current A 5.20
Running Current COOLING A 4.70
HEATING A 5.20
Maximum Current A 6.80
Power Factor COOLING 98
HEATING % 98
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Number of core
3 (1.5mm)
Power Cord
Length m
1.3
Thermostat
Electronic Control
Protection Device
Electronic Control
Note
z Specification is subject to change without prior notice for further improvement.
z Operational temperature range:
Indoor Outdoor
Temperature °C
* DBT *WBT *DBT *WBT
Maximum 32 23 43 26
COOLING
Minimum 16 11 16 11
Maximum 30 - 24 18
HEATING
Minimum 16 - -5 -6
NOTICE: This model is not suitable for 24 hours non-stopping operation in heating mode below -5°C. If this model
is used out of above conditions, the outdoor unit might be frozen up and stop operation for protection
control.
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
9
3. Features
Inverter Technology
o Wider output power range
o Energy saving
o Quick Cooling
o More precise temperature control
Long Installation Piping
o CS/CU-UE9/12JKE, long piping up to 15 meters.
Easy to use remote control
Quality Improvement
o Random auto restart after power failure for safety restart operation
o Gas leakage protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 12-hour timer
Serviceability Improvement
o Breakdown Self Diagnosis Function.
10
4. Location of Controls and Components
Indoor Unit
4.1 Outdoor Unit
4.2 Remote Control
z For normal operation, the ERROR RESET button is
not in use.
z Press RESET button to restore the remote control’s
default setting.
OFF/ON
Operation
mode
Airflow direction
adjustment
Timer
setting
Temperature
setting
Transmitter
Fan speed
selection
11
5. Dimensions
5.1 Indoor Unit
Unitmm
CS-UE9JKE
12
CS-UE12JKE
13
5.2 Outdoor Unit
Unit: mm
14
6. Refrigeration Cycle Diagram
15
7. Block Diagram
16
8. Wiring Diagram
CS/CU-UE9JKE
17
CS/CU-UE12JKE
18
9. Installation Instruction
9.1 Select the Best Location
9.1.1 Indoor Unit
There should not be any heat source or steam near the
unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
Recommended installation height for indoor unit shall be at
least 2.5m.
9.1.2 Outdoor Unit
If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
There should not be any animal or plant which could be
affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
Do not place any obstacles which may cause a short circuit
of the discharged air.
If piping length is over the rated length, additional refrigerant
should be added as shown in the table below:
Example: If the unit is installed at a 10m distance, the quantity
of additional refrigerant should be 50 g.
…… (10-7.5) m x 20g/m = 50 g
Piping size Model
Gas Liquid
Rated
Length
(m)
Max
Elevati
on (m)
Min
Piping
Length
(m)
Max
Piping
Length
(m)
Additional
Refrigera
nt (g/m)
UE9JKE 3/8” 1/4" 7.5 5 3 15 20
UE12JKE 3/8” 1/4” 7.5 5 3 15 20
11.1.3
Indoor/Outdoor Unit
19
Wall
Indoor Outdoor
15 mm
Sleeve for
tube ass’y
Approx. 5 - 7 mm
Bushing for tube ass’y
Putty or caulking compound
Ø 70 through hole
9.2 Indoor Unit
9.2.1 How to Fix Installation Plate
The centre of installation plate should be at more than 450mm at right and left of the wall.
The distance from installation plate edge to ceiling should be more than 67mm.
From installation plate left edge to unit's left side is 62mm (UE9JKE) or 98mm (UE12JKE).
From installation plate right edge to unit's right is 79mm (UE9JKE) or 112mm (UE12JKE).
B : For left side piping, piping connection for liquid should be about 10 mm from this line.
: For left side piping, piping connection for gas should be about 45mm from this line.
: For left side piping, piping connecting cable should be about 785mm (UE9JKE) or 800mm (UE12JKE) from
this line.
1 Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider
using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with
the thread and using a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
z Put measuring tape at position as shown in the diagram above. The hole centre is
obtained by measuring the distance namely 105mm and 145mm for left and right hole
respectively (UE9JKE), or 150mm and 125mm for (UE12JKE).
z Drill the piping plate hole at either the right or left and the hole should be slightly slanted
to the outdoor side.
9.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1 Insert the piping sleeve to the hole.
2 Fix the busing to the sleeve.
3 Cut the sleeve until it extrudes about 15mm from the wall
4 Finish by sealing the sleeve with putty or caulking compound at the
final stage.
Caution
When the wall is hollow, please be sure to use the sleeve for tube
ass’y to prevent dangers caused by mice biting the connecting
cable.
20
9.2.3 Indoor Unit Installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Panasonic CS-UE12JKE Datasheet

Category
Split-system air conditioners
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI