FTXS20K

Daikin FTXS20K, CTXS35K2V1B, FTXS35K User manual

  • Hello! I am an AI chatbot trained to assist you with the Daikin FTXS20K User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
FTXS20K2V1B
FTXS25K2V1B
CTXS15K2V1B
CTXS35K2V1B
EnglishDeutschFrançaisNederlandsEspañolItaliano
Eλληνικά
PortuguesPyccкийTürkçe
00_CV_3P297033-1.indd 1 9/16/2011 3:24:43 PM
1
Feature
For your comfort and energy
saving
Other functions
COMFORT AIRFLOW OUTDOOR UNIT QUIET ECONO
Theairowdirectionwillbeinupward
whileinCOOLoperation,indownward
whileinHEAToperation.Thisfunction
willpreventcoldorwarmairfrom
directlyblowingonyourbody.
Page15
OUTDOORUNITQUIEToperation
lowersthenoiseleveloftheoutdoor
unit.Thisfunctionisusefulwhenyou
needtoconsiderthenoiseforyour
neighbourhood.
Page19
Thisfunctionenablesefcientoperation
bylimitingthemaximumpower
consumption.Itisusefulwhenusingthe
airconditionerandotherelectrical
devicessimultaneously.
Page20
INTELLIGENT EYE
TheINTELLIGENTEYEsensordetectsthehumanmovementin
aroom.Ifnooneisintheroomformorethan20minutes,the
operationautomaticallychangestoenergysavingoperation.
Page16
WEEKLY TIMER
Upto4timersettingscanbesavedforeachdayoftheweek
accordingtoyourfamily’slifestyle.TheWEEKLYTIMERallows
youtoseton/offtimeandthedesiredtemperature.
Page23
01_EN_3P297033-1.indd 1 10/12/2011 2:14:56 PM
English
2
COMFORT AIRFLOW OUTDOOR UNIT QUIET ECONO
Theairowdirectionwillbeinupward
whileinCOOLoperation,indownward
whileinHEAToperation.Thisfunction
willpreventcoldorwarmairfrom
directlyblowingonyourbody.
Page15
OUTDOORUNITQUIEToperation
lowersthenoiseleveloftheoutdoor
unit.Thisfunctionisusefulwhenyou
needtoconsiderthenoiseforyour
neighbourhood.
Page19
Thisfunctionenablesefcientoperation
bylimitingthemaximumpower
consumption.Itisusefulwhenusingthe
airconditionerandotherelectrical
devicessimultaneously.
Page20
Contents
Read before Operation
SafetyPrecautions.......................................... 3
NameofParts................................................. 5
PreparationbeforeOperation......................... 9
Operation
AUTO·DRY·COOL·HEAT·FAN
Operation...........................................11
AdjustingtheAirflowDirection
andRate............................................13
COMFORTAIRFLOWOperation.......15
INTELLIGENTEYEOperation...........16
POWERFULOperation......................18
OUTDOORUNITQUIET
Operation...........................................19
ECONOOperation.............................20
OFFTIMEROperation.......................21
ONTIMEROperation.........................22
WEEKLYTIMEROperation................23
Multi Connection
NoteforMultiSystem.................................. 29
Care
CareandCleaning....................................... 31
Troubleshooting
Troubleshooting........................................... 36
TheEnglishtextistheoriginalinstruction.Otherlanguagesare
translationsoftheoriginalinstructions.
01_EN_3P297033-1.indd 2 10/12/2011 2:14:59 PM
3
Safety Precautions
•Keepthismanualwheretheoperatorcaneasilyndit.
•Readtheprecautionsinthismanualcarefullybeforeoperatingtheunit.
•TheprecautionsdescribedhereinareclassiedasWARNINGandCAUTION.Theybothcontainimportantinformation
regardingsafety.Besuretoobserveallprecautionswithoutfail.
WARNING
CAUTION
Failuretofollowtheseinstructionsproperlymayresultin
personalinjuryorlossoflife.
Failuretoobservetheseinstructionsproperlymayresultin
propertydamageorpersonalinjury,whichmaybeserious
dependingonthecircumstances.
Neverattempt.
Neverwettheairconditionernortheremotecontrollerwith
water.
Besuretofollowtheinstructions.
Nevertouchtheairconditionernortheremotecontrollerwith
wethands.
Besuretoestablishanearthconnection.
•Afterreading,keepthismanualinaconvenientplacesothatyoucanrefertoitwhenevernecessary.Iftheequipmentis
transferredtoanewuser,besurealsotohandoverthemanual.
WARNING
• Inordertoavoidre,explosionorinjury,donotoperatetheunitwhenharmful,amongwhichammableorcorrosive
gases,aredetectedneartheunit.
• Beawarethatprolonged,directexposuretocoolorwarmairfromtheairconditioner,ortoairthatistoocoolortoo
warmcanbeharmfultoyourphysicalconditionandhealth.
• Donotplaceobjects,includingrods,yourngers,etc.,intheairinletoroutlet.Productmalfunctioning,productor
injurydamagemayresultduetocontactwiththeairconditioner’shigh-speedfanblades.
• Donotattempttorepair,dismantle,reinstallormodifytheairconditioneryourselfasthismayresultinwaterleakage,
electricshocksorrehazards.
• Donotuseammablesprayneartheairconditioner,orotherwiseremayresult.
• Bewareofreincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolor
warmair,refrigerantleakagecouldbethecause.Consultyourdealerforassistance.Therefrigerantwithintheair
conditionerissafeandnormallydoesnotleak.
However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxious
gas.Donotlongerusetheairconditioneruntilaqualiedservicepersonconrmsthattheleakagehasbeen
repaired.
• Donotattempttoinstallorrepairtheairconditioneryourself.Improperworkmanshipmayresultinwaterleakage,
electricshocksorrehazards.Pleasecontactyourlocaldealerorqualiedpersonnelforinstallationand
maintenancework.
• Whentheairconditionerismalfunctioning(givingoffaburningodour,etc.)turnoffpowertotheunitandcontactyour
localdealer.Continuedoperationundersuchcircumstancesmayresultinafailure,electricshocksorrehazards.
•
Besuretoinstallanearthleakagebreaker.Failuretoinstalltheearthleakagebreakermayresultinelectricshocksorre.
•Besuretoearththeunit.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfect
earthingmayresultinelectricshocks.
CAUTION
• Donotusetheairconditionerforpurposesotherthanthoseforwhichitisintended.Donotusetheairconditionerfor
coolingprecisioninstruments,food,plants,animalsorworksofartasthismayadverselyaffecttheperformance,
qualityand/orlongevityoftheobjectconcerned.
• Donotexposeplantsoranimalsdirectlytoairowfromtheunitasthismaycauseadverseeffects.
• Donotplaceappliancesthatproducenakedamesinplacesexposedtotheairowfromtheunitasthismayimpair
combustionoftheburner.
• Donotblockairinletsnoroutlets.Impairedairowmayresultininsufcientperformanceortrouble.
• Donotsitontheoutdoorunit,putthingsontheunit,orpulltheunit.Doingsomaycauseaccidents,suchasfallingor
topplingdown,thusresultingininjury,productmalfunctioning,orproductdamage.
01_EN_3P297033-1.indd 3 10/12/2011 2:14:59 PM
English
4
CAUTION
• Donotplaceobjectsthataresusceptibletomoisturedirectlybeneaththeindoororoutdoorunits.Undercertain
conditions,condensationonthemainunitorrefrigerantpipes,airlterdirtordrainblockagemaycausedripping,
resultinginfoulingorfailureoftheobjectconcerned.
• Afterprolongeduse,checktheunitstandanditsmountsfordamage.Iftheyareleftinadamagedcondition,theunit
mayfallandcauseinjury.
• Toavoidinjury,donottouchtheairinletoraluminiumnsoftheindoororoutdoorunits.
• Theapplianceisnotintendedforusebyunattendedyoungchildrenorinrmpersons.Impairmentofbodilyfunctions
andharmtohealthmayresult.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeunitoritsremotecontroller.Accidental
operationbyachildmayresultinimpairmentofbodilyfunctionsandharmhealth.
• Donotgiveimpacttotheindoorandoutdoorunits,orotherwiseproductdamagemayresult.
• Donotplaceammableitems,suchasspraycans,within1moftheairoutlet.
Thespraycansmayexplodeasaresultofhotairfromtheindoororoutdoorunits.
•
Becarefulnottoletpetsurinateontheairconditioner.Urinationontheairconditionermayresultinelectricshocksorre.
• Toavoidoxygendepletion,ensurethattheroomisadequatelyventilatedifequipmentsuchasaburnerisused
togetherwiththeairconditioner.
• Beforecleaning,besuretostopunitoperation,turnthebreakerofforremovethepowercord.Otherwise,anelectric
shockandinjurymayresult.
• Onlyconnecttheairconditionertothespeciedpowersupplycircuit.Powersuppliesotherthantheonespecied
mayresultinelectricshocks,overheatingandres.
•
Arrangethedrainhosetoensuresmoothdrainage.Imperfectdrainagemaycausewettingofthebuilding,furnitureetc.
• Donotplaceobjectsindirectproximityoftheoutdoorunitanddonotletleavesandotherdebrisaccumulatearound
theunit.Leavesareahotbedforsmallanimalswhichcanentertheunit.Onceintheunit,suchanimalscancause
malfunctions,smokeorrewhenmakingcontactwithelectricalparts.
• Donotplaceobjectsaroundtheindoorunit.
Doingsomayhaveanadverseinuenceontheperformance,productquality,andlifeoftheairconditioner.
• Thisapplianceisnotintendedtobeusedbypersonswithreducedphysical,sensoryormentalcapabilities,orwith
lackofoperationknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerningtheapplianceuseby
personresponsiblefortheirsafety.
Keepoutofchildren’sreachtoensurethattheydonotplaywiththeappliance.
• Toavoidelectricshocks,donotoperatewithwethands.
• Donotwashtheairconditionerwithwater,asthismayresultinelectricshocksorre.
• Donotplacewatercontainers(vasesetc.)abovetheunit,asthismayresultinelectricshocksorrehazards.
Installation site.
Toinstalltheairconditionerinthefollowingtypesofenvironments,consultthedealer.
•Placeswithanoilyambientorwheresteamorsootoccurs.
•Saltyenvironmentsuchascoastalareas.
•Placeswheresuldegasoccurssuchashotsprings.
•Placeswheresnowmayblocktheoutdoorunit.
•Theindoorunitisatleast1mawayfromanytelevisionorradioset(unitmaycauseinterferencewiththepictureorsound).
•Thedrainfromtheoutdoorunitmustbedischargedtoaplaceofgooddrainage.
Consider nuisance to your neighbours from noises.
Forinstallation,chooseaplaceasdescribedbelow.
•Aplacesolidenoughtobeartheweightoftheunitwhichdoesnotamplifytheoperationnoiseorvibration.
•Aplacefromwheretheairdischargedfromtheoutdoorunitortheoperationnoisewillnotannoyyourneighbours.
Electrical work.
•Forpowersupply,besuretouseaseparatepowercircuitdedicatedtotheairconditioner.
System relocation.
•Relocatingtheairconditionerrequiresspecializedknowledgeandskills.Pleaseconsultthedealerifrelocationis
necessaryformovingorremodeling.
01_EN_3P297033-1.indd 4 10/12/2011 2:15:00 PM
Display
5
Name of Parts
Indoor Unit
Air inlet
Front panel
Air outlet
Louvers (vertical blades)
• Thelouversareinsideoftheairoutlet.
Page13
INTELLIGENT EYE
sensor
• Itdetectsthemovementsof
peopleandautomatically
switchesbetweennormal
operationandenergysaving
operation.
Page16
Flap (horizontal blade)
Page13
INTELLIGENT EYE lamp
(green)
Page16
Signal receiver
• Itreceivessignalsfromtheremote
controller.
• Whentheunitreceivesasignal,youwill
hearabeepsound.
Case Soundtype
Operationstart beep-beep
Settingchanged beep
Operationstop longbeep
Indoor unit ON/OFF switch
• Pressthisswitchoncetostartoperation.
Pressonceagaintostopit.
• Theoperationmodereferstothefollowingtable.
Mode Temperaturesetting Airowrate
AUTO 25°C AUTO
• Thisswitchisusefulwhentheremotecontrollerismissing.
Model name
plate
Room temperature
sensor
• Itdetectstheairtemperature
aroundtheunit.
TIMER lamp (yellow)
Page21
OPERATION lamp
(green)
01_EN_3P297033-1.indd 5 10/12/2011 2:15:01 PM
English
6
Outdoor Unit
•Appearanceoftheoutdoorunitmaydifferfromsomemodels.
Open the front panel
Air  lter
Titanium apatite
photocatalytic
air-purifying  lter
Refrigerant piping and
inter-unit wiring
Earth terminal
• Itisinsideofthiscover.
Drain hose
Air inlet
(back and side)
Air outlet
Outdoor temperature
sensor (back)
Model name plate
01_EN_3P297033-1.indd 6 10/12/2011 2:15:02 PM
7
Name of Parts
Remote Controller
Signal transmitter
Receiver
• Tousetheremotecontroller,aimthe
transmitterattheindoorunit.Ifthere
isanythingtoblocksignalsbetween
theunitandtheremotecontroller,
suchasacurtain,theunitwillnot
operate.
• Donotdroptheremotecontroller.Do
notgetitwet.
• Themaximumdistancefor
communicationisapprox.7m.
FAN setting button
• Itselectstheairowratesetting.
Page14
POWERFUL button
• POWERFULoperation.
Page18
Display (LCD)
• Itdisplaysthecurrentsettings.
(Inthisillustration,eachsectionis
shownwithitsdisplaysonforthe
purposeofexplanation.)
TEMPERATURE
adjustment buttons
• Itchangesthetemperaturesetting.
Page12
ON/OFF button
• Pressthisbuttononcetostart
operation.
Pressonceagaintostopit.
Page11
Front cover
• Openthefrontcover.
Page8
Model ARC466A6
01_EN_3P297033-1.indd 7 10/12/2011 2:15:03 PM
English
8
Open the front cover
ECONO button
• ECONOoperation.
Page20
SWING button
•
Adjustingtheairowdirection
.
Page13
INTELLIGENT EYE
button
•
INTELLIGENTEYE
operation
.
Page16
: WEEKLY button
: PROGRAM button
: COPY button
: BACK button
: NEXT button
• WEEKLYTIMERoperation.
Page23
ON TIMER button
Page22
CLOCK button
Page10
QUIET button
• OUTDOORUNITQUIET
operation.
Page19
COMFORT button
• COMFORTAIRFLOW
operation.
Page15
OFF TIMER button
Page21
TIMER CANCEL
button
• Itcancelsthetimersetting.
Page21,22
• Itcannotbeusedforthe
WEEKLYTIMERoperation.
SELECT button
• ItchangestheON/OFF
TIMERandWEEKLYTIMER
settings.
Page21,22,23
MODE selector button
• Itselectstheoperationmode.
(AUTO/DRY/COOL/HEAT/
FAN)
Page11
01_EN_3P297033-1.indd 8 10/12/2011 2:15:04 PM
9
Preparation before Operation
To set the batteries
Position and
correctly!
+
2
3
1
1. Slide the front cover to take it off.
2. Set twodry batteries AAA.LR03 (alkaline).
3. Set the front cover as before.
To x the remote controller holder on the wall
Remote
controller holder
Remote controller
Screws
1. Choose a place from where the signals
reach the unit.
2. Fix the holder to a wall, a pillar, or similar
location with the screws procured locally.
3. Place the remote controller in the remote
controller holder.
NOTE
Notes on batteries
• Whenreplacingthebatteries,usebatteriesofthesametype,andreplacebotholdbatteriestogether.
• Whenthesystemisnotusedforalongtime,takethebatteriesout.
• Thebatterieswilllastforapprox.1year.Iftheremotecontrollerdisplaybeginstofadeandthedegradationofreceptionperformanceoccurs
withinayear,however,replacebothbatterieswithnew,sizeAAA.LR03(alkaline).
• Theattachedbatteriesareprovidedfortheinitialuseofthesystem.
Theusableperiodofthebatteriesmaybeshortdependingonthemanufactureddateoftheairconditioner.
Notes on remote controller
• Neverexposetheremotecontrollertodirectsunlight.
• Dustonthesignaltransmitterorreceiverwillreducethesensitivity.Wipeoffdustwithsoftcloth.
• Signalcommunicationmaybedisabledifanelectronic-starter-typeuorescentlamp(suchasinverter-typelamps)isintheroom.Consultthe
shopifthatisthecase.
• Iftheremotecontrollersignalshappentooperateanotherappliance,movethatappliancetosomewhereelse,orconsulttheserviceshop.
01_EN_3P297033-1.indd 9 10/12/2011 2:15:04 PM
English
10
NOTE
Note on setting the clock
• Iftheindoorunit’sinternalclockisnotsettothecorrecttime,theONTIMER,OFFTIMERandWEEKLYTIMERwillnotoperatepunctually.
Turn the breaker on
•Afterthepoweristurnedon,theapoftheindoorunitopensandclosesoncetoset
thereferenceposition.
To set the clock
1. Press .
• “ ”isdisplayedontheLCD.
• “ ”and“ ”blink.
2. Press to set the current day of the week.
3. Press .
• “ ”blinks.
4. Press to set the clock to the present time.
•Holdingdown or rapidlyincreasesordecreasesthetimedisplay.
5. Press .
•Pointtheremotecontrollerattheindoorunitwhenpressingthebuttons.
• “ ”blinks.
01_EN_3P297033-1.indd 10 10/12/2011 2:15:06 PM
11
AUTO · DRY · COOL · HEAT ·
FAN Operation
Theairconditioneroperateswiththeoperationmodeofyourchoice.
Fromthenexttimeon,theairconditionerwilloperatewiththesameoperationmode.
To start operation
1. Press and select an operation mode.
•Eachpressingofthebuttonadvancesthemodesettinginsequence.
AUTO DRY COOL HEAT FAN
2. Press .
• ”isdisplayedontheLCD.
•TheOPERATIONlamplightsgreen.
Display
To stop operation
Press again.
• ”disappearsfromtheLCD.
•TheOPERATIONlampgoesoff.
NOTE
MODE Notesoneachoperationmode
HEAT
•Sincethisairconditionerheatstheroombytakingheatfromoutdoorairtoindoors,theheatingcapacitybecomessmallerin
loweroutdoortemperatures.Iftheheatingeffectisinsufcient,itisrecommendedtouseanotherheatingappliancein
combinationwiththeairconditioner.
•Theheatpumpsystemheatstheroombycirculatinghotairaroundallpartsoftheroom.AfterthestartofHEAToperation,
ittakessometimebeforetheroomgetswarmer.
•InHEAToperation,frostmayoccurontheoutdoorunitandlowertheheatingcapacity.Inthatcase,thesystemswitches
intodefrostingoperationtotakeawaythefrost.
•Duringdefrostingoperation,hotairdoesnotowoutofindoorunit.
COOL
•Thisairconditionercoolstheroombyreleasingtheheatintheroomoutside.
Therefore,thecoolingperformanceoftheairconditionermaybedegradediftheoutdoortemperatureishigh
DRY
•Thecomputerchipworkstoridtheroomofhumiditywhilemaintainingthetemperatureasmuchaspossible.Itautomatically
controlstemperatureandairowrate,somanualadjustmentofthesefunctionsisunavailable.
AUTO
•InAUTOoperation,thesystemselectsanappropriateoperationmode(COOLorHEAT)basedontheroomandoutside
temperaturesandstartstheoperation.
•Thesystemautomaticallyreselectssettingataregularintervaltobringtheroomtemperaturetouser-settinglevel.
FAN •Thismodeisvalidforfanonly.
01_EN_3P297033-1.indd 11 10/12/2011 2:15:07 PM
English
12
To change the temperature setting
Press .
•ThedisplayeditemsontheLCDwillchangewhenevereitheroneofthebuttonsis
pressed.
COOLoperation HEAToperation AUTOoperation DRYorFANoperation
18-32°C 10-30°C 18-30°C
Thetemperaturesettingis
notvariable.
Press
toraisethetemperatureandpress tolowerthe
temperature.
Operating conditions
Recommended temperature setting
• Forcooling:26-28°C
• Forheating:20-24°C
Tips for saving energy
• Becarefulnottocool(heat)theroomtoomuch.
Keepingthetemperaturesettingatamoderatelevelhelpssaveenergy.
• Coverwindowswithablindoracurtain.
Blockingsunlightandairfromoutdoorsincreasesthecooling(heating)effect.
• Cloggedairlterscauseinefcientoperationandwasteenergy.Cleanthemonceinaboutevery2weeks.
Notes on the operating conditions
• Theoutdoorunitconsumessomepowertohaveitselectriccomponentsworkevenwhileitisnotoperating.
ConnectingoutdoorunitRXS20/25:1-15W
Otheroutdoorunits:15-20W
Theoutdoorunitconsumes40to55Wofpoweratthetimeofcompressorpreheating.
• Ifyouarenotgoingtousetheairconditionerforalongperiod,forexampleinspringorautumn,turnthebreakeroff.
• Usetheairconditionerinthefollowingconditions.
MODE Operatingconditions Ifoperationiscontinuedoutofthisrange
COOL
Outdoortemperature:<2MXS>10-46°C
<3/4/5MXS>–10-46°C
<RXS>–10-46°C
Indoortemperature:18-32°C
Indoorhumidity:80%max.
•Asafetydevicemayworktostoptheoperation.
(Inmultisystem,itmayworktostoptheoperationofthe
outdoorunitonly.)
•Condensationmayoccurontheindoorunitanddrip.
HEAT
Outdoortemperature:<2/3/4/5MXS>–15-24°C
<RXS>–15-24°C
Indoortemperature:10-30°C
•Asafetydevicemayworktostoptheoperation.
DRY
Outdoortemperature:<2MXS>10-46°C
<3/4/5MXS>–10-46°C
<RXS>–10-46°C
Indoortemperature:18-32°C
Indoorhumidity:80%max.
•Asafetydevicemayworktostoptheoperation.
•Condensationmayoccurontheindoorunitanddrip.
• Operationoutsidethishumidityortemperaturerangemaycauseasafetydevicetodisablethesystem.
01_EN_3P297033-1.indd 12 10/12/2011 2:15:07 PM
13
Adjusting the Airfl ow Direction
and Rate
Youcanadjusttheairowdirectiontoincreaseyourcomfort.
To start auto swing
Upper and lower airfl ow direction
Press .
• isdisplayedontheLCD.
•Theap(horizontalblade)willbegintoswing.
To set the fl ap at desired position
•Thisfunctioniseffectivewhileapisinautoswingmode.
Press when the fl ap has reached the
desired position.
• disappearsfromtheLCD.
To adjust the louvers at desired position
Hold the knob and move the louvers.
•Youwillndaknobontheleft-sideandtheright-side
blades.
•Whentheunitisinstalledinthecornerofaroom,the
directionofthelouvers(verticalblades)shouldbefacing
awayfromthewall.
Iftheyfacethewall,thewallwillblockoffthewind,
causingthecooling(orheating)efciencytodrop.
•Iftheapisintheway,press
ontheremotecontrollertomovetheapoutof
thewayandthenadjustthelouvers.
01_EN_3P297033-1.indd 13 10/12/2011 2:15:09 PM
English
14
To adjust the airfl ow rate setting
Press .
•Eachpressingof advancestheairowratesettinginsequence.
Auto Indoor unit quiet Low Middle low
MiddleMiddle highHigh
•Whentheairowissetto“ ”,indoorunitquietoperationwillstartandthenoise
fromtheunitwillbecomequieter.
•Inindoorunitquietoperation,theairowrateissettoaweaklevel.
•Ifthetemperaturedoesnotreachthedesiredpointintheindoorunitquietoperation,
changetheairowratesetting.
•InDRYmode,theairowratesettingisnotvariable.
NOTE
Notes on the angles of the fl ap
• Theapswingingrangedependsontheoperation.(Seethegure.)
FAN operationHEAT operationCOOL and
DRY operation
Upper limit
Stop operation
Lower limit
Upper limit
Upper limit
COMFORT AIRFLOW
Stop operation Stop operation
Lower limit
Lower limit
45°
COMFORT AIRFLOW
15°
45°
50°
45°
• IftheairconditionerisoperatedinCOOLorDRYoperationwiththeapkeptstoppedinthedownwarddirection,theapwillautomatically
startoperatinginapproximatelyanhourinordertopreventdewcondensation.
Note on airfl ow rate setting
• Atsmallerairowrates,thecooling(heating)effectisalsosmaller.
CAUTION
• Alwaysusearemotecontrollertoadjusttheanglesoftheap.Ifyouattempttomovetheapandlouversforciblywithhandwhentheyare
swinging,themechanismmaybebroken.
• Becarefulwhenadjustingthelouvers.
Insidetheairoutlet,afanisrotatingatahighspeed.
01_EN_3P297033-1.indd 14 10/12/2011 2:15:10 PM
15
COMFORT AIRFLOW Operation
TheowofairwillbeintheupwarddirectionwhileinCOOLoperationandinthe
downwarddirectionwhileinHEAToperation,whichwillprovideacomfortable
windthatwillnotcomeindirectcontactwithpeople.
To start COMFORT AIRFLOW operation
Press .
• isdisplayedontheLCD.
•AirowrateissettoAuto.
COOL/DRY:Theapwillgoup.
HEAT:Theapwillgodown.
To cancel COMFORT AIRFLOW operation
Press again.
•TheapswillreturntothememorypositionfrombeforeCOMFORTAIRFLOW
operation.
•
”disappearsfromtheLCD.
COOL operation HEAT operation
NOTE
Notes on COMFORT AIRFLOW operation
• Theappositionwillchange,preventingairfromblowingdirectlyontheoccupantsoftheroom.
• POWERFULoperationandCOMFORTAIRFLOWoperationcannotbeusedatthesametime.
Priorityisgiventothefunctionofwhicheverbuttonispressedlast.
• TheairowratewillbesettoAuto.Iftheupperandlowerairowdirectionisselected,theCOMFORTAIRFLOWoperationwillbecanceled.
01_EN_3P297033-1.indd 15 10/12/2011 2:15:11 PM
English
16
“INTELLIGENTEYE”istheinfraredsensorwhichdetectsthehumanmovement.
Ifnobodyintheroomformorethan20minutes,theoperationautomatically
changestoenergysavingoperation.
To start INTELLIGENT EYE operation
Press .
• ”isdisplayedontheLCD.
•TheINTELLIGENTEYElamplightsgreen.
Display
To cancel INTELLIGENT EYE operation
Press again.
• ”disappearsfromtheLCD.
•TheINTELLIGENTEYElampgoesoff.
INTELLIGENT EYE Operation
01_EN_3P297033-1.indd 16 10/12/2011 2:15:12 PM
17
INTELLIGENT EYE Operation
NOTE
Notes on INTELLIGENT EYE operation
• Applicationrangeisasfollows.
90°
55°
7m
55°
Vertical angle 90°
(Side view)
Horizontal angle 110°
(Top view)
7m
• Sensormaynotdetectmovingobjectsfurtherthan7maway.(Checktheapplicationrange.)
• Sensordetectionsensitivitychangesaccordingtoindoorunitlocation,thespeedofpassersby,temperaturerange,etc.
• Thesensoralsomistakenlydetectspets,sunlight,utteringcurtainsandlightreectedoffofmirrorsaspassersby.
• INTELLIGENTEYEoperationwillnotgoonduringPOWERFULoperation.
• NIGHTSETmode
Page21
willnotgoonduringuseofINTELLIGENTEYEoperation.
CAUTION
• Donotplacelargeobjectsnearthesensor.
Alsokeepheatingunitsorhumidiersoutsidethesensor’sdetectionarea.Thissensorcandetectundesirableobjects.
• DonothitorviolentlypushtheINTELLIGENTEYEsensor.Thiscanleadtodamageandmalfunction.
[Example]
When someone is in the
room
Normal operation
•Theairconditionerisinnormal
operationwhilethesensoris
detectingthemovementofpeople.
When no one is in the room
20minutes after, start energy
saving operation.
•Thesettemperatureisshiftedin
±2°Csteps.
Someone is back in the
room
Back to normal operation.
•Theairconditionerwillreturnto
normaloperationwhenthesensor
detectsthemovementofpeople
again.
INTELLIGENT EYE operation is useful for energy saving
Energy saving operation
• Ifnopresencedetectedintheroomfor20minutes,theenergysavingoperationwillstart.
• Thisoperationchangesthetemperature–2°CinHEAT/+2°CinCOOL/+1°CinDRYoperationfromsettemperature.
Whentheroomtemperatureexceeds30°C,theoperationchangesthetemperature+1°CinCOOL/+1°CinDRYoperationfromset
temperature.
• ThisoperationdecreasestheairowrateslightlyinFANoperationonly.
01_EN_3P297033-1.indd 17 10/12/2011 2:15:12 PM
English
18
POWERFUL Operation
POWERFULoperationquicklymaximisesthecooling(heating)effectinany
operationmodes.Youcangetthemaximumcapacity.
To start POWERFUL operation
Press during operation.
•POWERFULoperationendsin20minutes.Thenthesystemautomaticallyoperates
againwiththeprevioussettingswhichwereusedbeforePOWERFULoperation.
•
”isdisplayedontheLCD.
To cancel POWERFUL operation
Press again.
• ”disappearsfromtheLCD.
[Example]
Normal operation
•Whenyouwanttogetthe
coolingeffectquickly,start
thePOWERFULoperation.
POWERFUL operation
•POWERFULoperationwill
workfor20minutes.
Back to normal
operation
NOTE
Notes on POWERFUL operation
• WhenusingPOWERFULoperation,therearesomefunctionswhicharenotavailable.
• POWERFULoperationcannotbeusedtogetherwithECONO,COMFORTAIRFLOWorOUTDOORUNITQUIEToperation.
Priorityisgiventothefunctionofwhicheverbuttonispressedlast.
• POWERFULoperationcanonlybesetwhentheunitisrunning.Pressing
causesthesettingstobecanceled,andthe“ ”disappears
fromtheLCD.
• POWERFULoperationwillnotincreasethecapacityoftheairconditioneriftheairconditionerisalreadyinoperationwithitsmaximum
capacitydemonstrated.
•
In COOL and HEAT operation
Tomaximizethecooling(heating)effect,thecapacityofoutdoorunitisincreasedandtheairowrateisxedtothemaximumsetting.
Thetemperatureandairowsettingsarenotvariable.
•
In DRY operation
Thetemperaturesettingisloweredby2.5°Candtheairowrateisslightlyincreased.
•
In FAN operation
Theairowrateisxedtothemaximumsetting.
•
In AUTO operation
Tomaximizethecooling(heating)effect,thecapacityofoutdoorunitisincreasedandtheairowrateisxedtothemaximumsetting.
•
When using priority room setting
Seenoteformultisystem.
Page29
01_EN_3P297033-1.indd 18 10/12/2011 2:15:13 PM
19
OUTDOOR UNIT QUIET
Operation
OUTDOORUNITQUIEToperationlowersthenoiseleveloftheoutdoorunitby
changingthefrequencyandfanspeedontheoutdoorunit.Thisfunctionis
convenientduringthenight.
To start OUTDOOR UNIT QUIET operation
Press .
• isdisplayedontheLCD.
To cancel OUTDOOR UNIT QUIET operation
Press again.
• disappearsfromtheLCD.
[Example] Using the OUTDOOR UNIT QUIET operation during the night.
•Thenoiseleveloftheoutdoorunitwillbelower.
Thisfunctionisusefulwhenyouneedtoconsiderthenoiseforyourneighbourhood.
NOTE
Notes on OUTDOOR UNIT QUIET operation
• Ifusingamultisystem,theOUTDOORUNITQUIEToperationwillworkonlywhenthisfunctionissetonalloperatedindoorunits.However,
ifusingpriorityroomsetting,refertonoteformultisystem.
Page29
• ThisfunctionisavailableinCOOL,HEAT,andAUTOoperation.
ThisisnotavailableinFANandDRYoperation.
• POWERFULoperationandOUTDOORUNITQUIEToperationcannotbeusedatthesametime.
Priorityisgiventothefunctionofwhicheverbuttonispressedlast.
• EventheoperationisstoppedbyusingtheremotecontrollerortheindoorunitON/OFFswitchwhenusingOUTDOORUNITQUIET
operation,
willremainontheremotecontrollerdisplay.
• OUTDOORUNITQUIEToperationwilldropneitherthefrequencynorfanspeediftheyhavebeenalreadydroppedlowenough.
01_EN_3P297033-1.indd 19 10/12/2011 2:15:14 PM
/