Brocade Communications Systems ICX 7450 series Hardware Installation Manual

Category
Network switches
Type
Hardware Installation Manual
53-1003623-03
10 October 2016
®
Brocade ICX 7450
Hardware Installation Guide
Supporting FastIron Software Release 08.0.30
Copyright © 2015 Brocade Communications Systems, Inc. All Rights Reserved.
ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and
Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of
Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names
mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to
this document at any time, without notice, and assumes no responsibility for its use. This informational document describes
features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.
Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with
respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that
accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other
open source license agreements. To find out which open source software is included in Brocade products, view the licensing
terms applicable to the open source software, and obtain a copy of the programming source code, please visit
http://www.brocade.com/support/oscd.
Title Publication number Summary of changes Date
Brocade ICX 7450 Hardware Installation
Guide
53-1003399-01 Initial Release September 2014
Brocade ICX 7450 Hardware Installation
Guide
53-1003399-02 Added support for DC power
supply
November 2014
Brocade ICX 7450 Hardware Installation
Guide
53-1003623-01 Updated document number,
release date, and software
release number
March 2015
Brocade ICX 7450 Hardware Installation
Guide
53-1003623-02 Updates to the Technical
Specifications Appendix.
April 2015
Brocade Communications Systems, Incorporated
Document History
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000
Fax: 1-408-333-8101
E-mail: info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: china-info@brocade.com
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: emea-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 – 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: china-info@brocade.com
Brocade ICX 7450 Hardware Installation Guide iii
53-1003623-02
Contents
About This Guide
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . vii
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Command syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Notes, cautions, and danger notices . . . . . . . . . . . . . . . . . . . . . viii
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Chapter 1 Brocade ICX 7450 Overview
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Brocade ICX 7450 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Brocade ICX 7450 customizable switches . . . . . . . . . . . . . . . . . . 1
Views of the Brocade ICX 7450 switch . . . . . . . . . . . . . . . . . . . . . . . . 4
Brocade ICX 7450 slot and Ethernet port numbering . . . . . . . . . . . . 7
Supported expansion modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Supported transceivers and cables. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 2 Installing the Brocade ICX 7450
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Unpacking the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Installation and safety considerations. . . . . . . . . . . . . . . . . . . . . . . .12
Electrical considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Environmental considerations . . . . . . . . . . . . . . . . . . . . . . . . . .12
Location considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Cabinet considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Recommendations for cable management . . . . . . . . . . . . . . . .13
Installation tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
iv Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
Installation precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
General precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Lifting precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Power precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installing the device on a desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installing the device in a rack or cabinet. . . . . . . . . . . . . . . . . . . . . . 17
2-post rack mount installation . . . . . . . . . . . . . . . . . . . . . . . . . .18
4-post rack mount installation . . . . . . . . . . . . . . . . . . . . . . . . . .20
Connecting devices in a stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Stacking ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Stacking configuration requirements. . . . . . . . . . . . . . . . . . . . .22
Stacking cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Stack size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Stacking topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Grounding the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Powering on the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Power supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Power supply usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Using a second power supply . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Installing and replacing a power supply unit . . . . . . . . . . . . . . .26
Installing an AC power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Installing a DC power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
DC-DC power source cautions. . . . . . . . . . . . . . . . . . . . . . . . . . .30
Attaching a PC or terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Connecting to the management port. . . . . . . . . . . . . . . . . . . . . . . . . 31
Installing an SFP/SFP+ transceiver . . . . . . . . . . . . . . . . . . . . . . . . . .31
Connecting network devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Connecting a network device to a copper port . . . . . . . . . . . . .32
Connecting a network device to a fiber port . . . . . . . . . . . . . . .32
Chapter 3 Brocade ICX 7450 Operation
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
LED activity interpretation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Brocade ICX 7450 front panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . .35
Brocade ICX 7450 rear panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 41
LED patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Diagnostic tests and monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Chapter 4 Managing the Brocade ICX 7450
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Hardware maintenance schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Brocade ICX 7450 Hardware Installation Guide v
53-1003623-02
Replacing a copper or fiber-optic module . . . . . . . . . . . . . . . . . . . . . 47
Removing a copper or fiber-optic module . . . . . . . . . . . . . . . . .48
Cabling a fiber-optic module . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Cleaning the fiber-optic connectors . . . . . . . . . . . . . . . . . . . . . .49
FRU removal and replacement procedures. . . . . . . . . . . . . . . . . . . .49
Replacing a power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Determining the need to replace a power supply . . . . . . . . . . . 51
Time and items required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Replacing a power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Replacing fan trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Determining the need to replace a fan assembly . . . . . . . . . . .52
Time and items required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Installing or replacing the fan assembly . . . . . . . . . . . . . . . . . .53
Replacing an expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Time and items required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Installing or replacing an expansion module . . . . . . . . . . . . . . .54
Appendix A Brocade ICX 7450 Specifications
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
System specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Power supply specifications (per PSU). . . . . . . . . . . . . . . . . . . . . . . . 61
Power consumption (typical configuration) . . . . . . . . . . . . . . . . . . . .61
Power consumption (maximum configuration) . . . . . . . . . . . . . . . . .62
Power consumption (modules). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Data port specifications (Ethernet) . . . . . . . . . . . . . . . . . . . . . . . . . .63
Serial port specifications (pinout - mini-USB) . . . . . . . . . . . . . . . . . .64
Serial port specifications (pinout RJ-45) . . . . . . . . . . . . . . . . . . . . . .64
Serial port specifications (protocol). . . . . . . . . . . . . . . . . . . . . . . . . .64
Memory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Regulatory compliance (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Regulatory compliance (safety)65
Regulatory compliance (environmental) . . . . . . . . . . . . . . . . . . . . . .65
Appendix B Brocade ICX 7450 Regulatory Statements
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
USA (FCC CFR 47 Part 15 Warning) . . . . . . . . . . . . . . . . . . . . . . . . . .67
vi Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
Industry Canada statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Europe and Australia (CISPR 22 Class A Warning) . . . . . . . . . . . . . .68
Germany (Noise Warning). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Japan (VCCI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
China . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
BSMI statement (Taiwan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Appendix C Brocade ICX 7450 Cautions and Danger Notices
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Danger Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Index
Brocade ICX 7450 Hardware Installation Guide vii
53-1003623-02
About This Guide
Audience
This document is designed for system administrators with a working knowledge of Layer 2 and
Layer 3 switching and routing.
If you are using a Brocade Layer 3 Switch, you should be familiar with the following protocols if
applicable to your network: IP, RIP, OSPF, BGP, IS-IS, PIM, and VRRP.
Supported hardware and software
This document is specific to the Brocade ICX 7450 running FastIron release 08.0.20a.
How this document is organized
The document contains the following components:
Chapter 1, “Brocade ICX 7450 Overview” provides an overview of the Brocade ICX 7450.
Chapter 2, “Installing the Brocade ICX 7450” provides the information needed to install the
switch in your network.
Chapter 3, “Brocade ICX 7450 Operation” discusses the day-to-day operational procedures for
using the switch.
Chapter 4, “Managing the Brocade ICX 7450” provides procedures for removing and replacing
the field-replaceable units (FRUs), including the fan assemblies and power supplies.
Appendix A, “Brocade ICX 7450 Specifications” provides tables of physical, environmental, and
general specifications.
Appendix B, “Brocade ICX 7450 Regulatory Statements” provides a list of the regulatory
statements for safety compliance.
Appendix C, “Brocade ICX 7450 Cautions and Danger Notices” provides a list of the
international caution and danger statements for safety compliance.
Document conventions
This section describes text formatting conventions and important notice formats used in this
document.
viii Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold text Identifies command names
Identifies the names of user-manipulated GUI elements
Identifies keywords
Identifies text to enter at the GUI or CLI
italic textProvides emphasis
Identifies variables
Identifies paths and Internet addresses
Identifies document titles
code text Identifies CLI output
For readability, command names in the narrative portions of this guide are presented in mixed
lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase.
Command syntax conventions
Command syntax in this manual follows these conventions:
command Commands are printed in bold.
--option, option Command options are printed in bold.
-argument, arg Arguments.
[ ] Optional elements appear in brackets.
variable Variables are printed in italics. In the help pages, values are underlined or
enclosed in angled brackets < >.
... Repeat the previous element, for example “member[;member...]”
value Fixed values following arguments are printed in plain font. For example,
--show WWN
| Boolean. Elements are exclusive. Example: --show -mode egress | ingress
Notes, cautions, and danger notices
The following notices and statements are used in this manual. They are listed below in order of
increasing severity of potential hazards.
NOTE
A note provides a tip, guidance, or advice, emphasizes important information, or provides a
reference to related information.
Brocade ICX 7450 Hardware Installation Guide ix
53-1003623-02
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you or cause
damage to hardware, firmware, software, or data.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely
hazardous to you. Safety labels are also attached directly to products to warn of these conditions
or situations.
Notice to the reader
This document might contain references to the trademarks of the following corporations. These
trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Corporation Referenced Trademarks and Products
Microsoft Corporation Windows, Windows NT, Internet Explorer
Oracle Corporation Oracle, Java, Sun, Solaris
Netscape Communications Corporation Netscape
Mozilla Corporation Mozilla Firefox
Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover
Related publications
The following Brocade documents supplement the information in this guide:
Brocade ICX 7450 Release Notes
Brocade ICX 7450 Administration Guide
Brocade ICX 7450 Platform and Layer 2 Configuration Guide
Brocade ICX 7450 Layer 3 Routing Configuration Guide
Brocade ICX 7450 Security Configuration Guide
Brocade ICX 7450 IP Multicast Configuration Guide
Brocade ICX 7450 Diagnostic Reference
Unified IP MIB Reference
The latest versions of these guides are posted at http://www.myBrocade.com/ethernetproducts.
xBrocade ICX 7450 Hardware Installation Guide
53-1003623-02
Additional information
This section lists additional Brocade and industry-specific documentation that you might find
helpful.
Brocade resources
To get up-to-the-minute information, go to http://www.myBrocade.com to register at no cost for a
user ID and password.
White papers, online demonstrations, and data sheets are available through the Brocade website
at:
http://www.myBrocade.com/products-solutions/products/index.page
For additional Brocade documentation, visit the Brocade website:
http://www.myBrocade.com
Release notes are available on the MyBrocade website.
Getting technical help
To contact Technical Support, go to http://www.myBrocade.com/services-support/index.page for
the latest e-mail and telephone contact information.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and
completeness of this document. However, if you find an error or an omission, or you think that a
topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your
comment, including the topic heading and page number and your suggestions for improvement.
Brocade ICX 7450 Hardware Installation Guide 1
53-1003623-02
Chapter
1
Brocade ICX 7450 Overview
In this chapter
Brocade ICX 7450 features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Views of the Brocade ICX 7450 switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Brocade ICX 7450 slot and Ethernet port numbering. . . . . . . . . . . . . . . . . . . 7
Supported expansion modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Supported transceivers and cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Brocade ICX 7450 features
The Brocade ICX 7450 is a high-density aggregation switch that offers 10/100 Mbps Ethernet,
1/10 Gigabit Ethernet (GbE), and 10/40 GbE line rates, low latency cut-through switching, and up
to 336 Gbps throughput for campus LAN and classic Ethernet data center environments.
The Brocade ICX 7450 switch features:
Comprehensive support for a range of 1 GbE, 10 GbE, and 40 GbE optics (refer to the latest
Brocade Optics Family Data Sheet).
Dual redundant, hot-swappable power supplies available with intake or exhaust airflow
(250 W AC or 510W DC for non-PoE switches, and 1000W AC or 510W DC for PoE switches)
ICX 7450-24P and ICX 7450-48P copper ports support PoE, PoE+, High PoE, and PoH.
1G SFP module with four 100 Mbps / 1 GbE SFP ports
10G SFP+ module with four 1/10 GbE SFP+ ports
10G copper module with four 1/10 GbE RJ-45 ports
Two 40 GbE QSFP+ stacking ports (supporting stacking for up to twelve switches)
Dual redundant, hot-swappable fan units available with intake or exhaust airflow.
One Gigabit Ethernet port (RJ-45) and one serial management port (mini-USB) to configure and
manage the switch through the CLI.
One USB port for the transfer of software and configuration files from an external disk drive.
Brocade ICX 7450 customizable switches
The Brocade ICX 7450 base systems do not ship with power supplies, fans, stacking modules, or
media expansion modules. Fans, power supplies, and expansion modules are ordered separately
to allow for building the system that meets your network needs. Table 1 lists the available power
supplies, fans, and expansion modules.
2Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
1Brocade ICX 7450 features
TABLE 1 SKUs for creating custom Brocade ICX 7450 switches
Part Description
ICX7400-4X1GF Brocade ICX 7450 4-port 1GbE SFP expansion module
ICX7400-4X10GF Brocade ICX 7450 4-port 1/10GbE SFP+ uplink / stacking expansion module
ICX7400-4X10GC Brocade ICX 7450 4-port 1/10GbE copper expansion module
ICX7400-1X40GQ Brocade ICX 7450 1-port 40G QSFP+ data uplink / stacking module
RPS15-E Brocade ICX non-PoE 250 W AC PSU, power-supply-side exhaust (port-side intake)
airflow
RPS15-I Brocade ICX non-PoE 250 W AC PSU, power-supply-side intake (port-side exhaust)
airflow
RPS16-E Brocade ICX PoE+ 1000 W AC PSU, power-supply-side exhaust (port-side intake)
airflow
RPS16-I Brocade ICX PoE+ 1000 W AC PSU, power-supply-side intake (port-side exhaust)
airflow
RPS16DC-E Brocade ICX 510 W DC PSU, power-supply-side exhaust (port-side intake) airflow
RPS16DC-I Brocade ICX 510 W DC PSU, power-supply-side intake (port-side exhaust) airflow
ICX-FAN10-E Brocade ICX 7450 power-supply-side exhaust airflow fan (two fans required with two
power supplies)
ICX-FAN10-I Brocade ICX 7450 power-supply-side intake airflow fan (two fans required with two
power supplies)
E1MG-100FX-IR-OM 100Base-FX IR SFP optic for SMF with LC connector, Optical Monitoring Capable. For
distances up to 15Km.
E1MG-100FX-LR-OM 100Base-FX LR SFP optic for SMF with LC connector, Optical Monitoring Capable. For
distances up to 40Km.
E1MG-100FX-OM 100Base-FX SFP optic MMF, LC connector, Optical Monitoring Capable
E1MG-BXD 1000Base-BXD SFP optic SMF, TX 1490nm and RX 1310nm, LC connector, single
strand SMF fiber. This optic should only be connected to an E1MG-BXU at the far end.
E1MG-BXU 1000Base-BXU SFP optic SMF, TX at 1310nm and RX at 1490nm, LC connector, single
strand SMF fiber. This optic should only be connected to an E1MG-BXD at the far end.
E1MG-LHA-OM-T 1000Base-LHA SFP optic SMF, LC connector, Optical Monitoring Capable (70km),
Industrial Temperature
E1MG-LX-OM 1000Base-LX SFP optic SMF, LC connector, Optical Monitoring Capable
E1MG-SX-OM 1000Base-SX SFP optic MMF, LC connector, Optical Monitoring Capable
E1MG-TX 1000BASE-TX SFP Copper, RJ-45 Connector
10G-SFPP-ER 10GBASE-ER SFP+ optic (LC), for up to 40km over SMF
10G-SFPP-LR 10GBASE-LR, SFP+ optic (LC), for up to 10km over SMF
10G-SFPP-LRM 10GBASE-LRM SFP+ optic (LC), for up to 220m over MMF
10G-SFPP-SR 10GBASE-SR, SFP+ optic (LC), target range 300m over MMF
10G-SFPP-ZR 10GBASE-ZR SFP+ optic (LC), for up to 80km over SMF
10G-SFPP-USR 10GE USR SFP+ optic (LC), target range 100m over MMF
40G-QSFP-LR4 40GBASE-LR4 QSFP+ optic (LC), for up to 10km over SMF
Brocade ICX 7450 features
Brocade ICX 7450 Hardware Installation Guide 3
53-1003623-02
1
40G-QSFP-SR4 40GBASE-SR4 QSFP+ optic (MTP 1x8 or 1x12), 100m over MMF
40G-QSFP-C-00501 40GE QSFP Direct Attached Copper Cable, 0.5m, 1-pack, passive
40G-QSFP-C-0101 40GE QSFP Direct Attached Copper Cable, 1m, 1-pack, passive
40G-QSFP-QSFP-C-0101 40GE Direct Attached QSFP+ to QSFP+ Active Copper cable, 1m, 1-pack
40G-QSFP-QSFP-C-0301 40GE Direct Attached QSFP+ to QSFP+ Active Copper cable, 3m, 1-pack
40G-QSFP-QSFP-C-0501 40GE Direct Attached QSFP+ to QSFP+ Active Copper cable, 5m, 1-pack
CC-MINIUSB-RJ45 Console cable, male mini-USB to male RJ-45
10G-SFPP-TWX-0101 Direct Attached SFPP Active Copper cable, 1m, 1-pack
10G-SFPP-TWX-0301 Direct Attached SFPP Active Copper cable, 3m, 1-pack
10G-SFPP-TWX-0501 Direct Attached SFPP Active Copper cable, 5m, 1-pack
10G-SFPP-TWX-0701 Direct Attached SFPP Active Copper cable, 7m, 1-pack
10G-SFPP-TWX-1001 Direct Attached SFPP Active Copper cable, 10m, 1-pack
ICX7750/7450-RMK FRU, Rack mount kit, 2 post, ICX 7750/7450
XBR-R000295 FRU, Universal rack mount kit, 4 post 24-32 inch depth rack, DX6740T/VDX6740T-1G
PCEURO Power Cord for RPS15/16, European version
PCUK Power Cord for RPS15/16, United Kingdom version
PCAUS Power Cord for use in Australia
PCJAPAN Power Cord for RPS15/16, Japan version
PCCHINA2-IEC309 Power Cord, China, IEC309 TO C13, 10A, 250V
PCSWISS-C1312G-HF Power Cord, Swiss, SEV1011 TO C13, 10A, 250V, halogen free
PCINDIA 6 foot AC power cord for India
TABLE 1 SKUs for creating custom Brocade ICX 7450 switches (Continued)
Part Description
4Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
1Views of the Brocade ICX 7450 switch
Views of the Brocade ICX 7450 switch
Figure 1 shows the front view of the Brocade ICX 7450-24 switch.
FIGURE 1 Front view of the Brocade ICX 7450-24
Figure 2 shows the front view of the Brocade ICX 7450-24P switch.
NOTE
PoE/PoE+ power is available to ports 1-24. High PoE/PoH is limited to ports 1-8.
FIGURE 2 Front view of the Brocade ICX 7450-24P
1System LEDs 6Mini-USB console port
2 Media/Stacking module LEDs 7 Reset button
3 Stack unit ID display 8 1GBase-T RJ-45 ports 1/1/1 - 1/1/24
4 Management port (RJ-45) 9 SFP/SFP+/QSFP+ ports 1/2/1 - 1/2/4
5 USB port (for flash drive)
1System LEDs 6Mini-USB console port
2 Media/Stacking module LEDs 7 Reset button
3 Stack unit ID display 8 1GBase-T RJ-45 ports 1/1/1 - 1/1/24
4 Management port (RJ-45) 9 SFP/SFP+/QSFP+ ports 1/2/1 - 1/2/4
5 USB port (for flash drive)
Views of the Brocade ICX 7450 switch
Brocade ICX 7450 Hardware Installation Guide 5
53-1003623-02
1
Figure 3 shows the front view of the Brocade ICX 7450-48 switch.
FIGURE 3 Front view of the Brocade ICX 7450-48
Figure 4 shows the front view of the Brocade ICX 7450-48P switch.
NOTE
PoE/PoE+ power is available to ports 1-48. High PoE/PoH is limited to ports 1-8.
FIGURE 4 Front view of the Brocade ICX 7450-48P
1System LEDs 6Mini-USB console port
2 Media/Stacking module LEDs 7 Reset button
3 Stack unit ID display 8 1GBase-T RJ-45 ports 1/1/1 - 1/1/48
4 Management port (RJ-45) 9 SFP+ ports 1/2/1 - 1/2/4
5 USB port (for flash drive)
1System LEDs 6Mini-USB console port
2 Media/Stacking module LEDs 7 Reset button
3 Stack unit ID display 8 1GBase-T RJ-45 ports 1/1/1 - 1/1/48
4 Management port (RJ-45) 9 SFP+ ports 1/2/1 - 1/2/4
5 USB port (for flash drive)
6Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
1Views of the Brocade ICX 7450 switch
Figure 5 shows the front view of the Brocade ICX 7450-48F switch.
FIGURE 5 Front view of the Brocade ICX 7450-48F
Figure 6 shows the rear view of the Brocade ICX 7450 switch.
FIGURE 6 Rear view of the Brocade ICX 7450
1System LEDs 6Mini-USB console port
2 Media/Stacking module LEDs 7 Reset button
3 Stack unit ID display 8 SFP port LEDs 1/1/1 - 1/1/48
4 Management port (RJ-45) 9 SFP+ ports 1/2/1 - 1/2/4
5 USB port (for flash drive)
1Grounding terminal 5Fan tray 1
2 Fan tray 2 6 Power supply unit 2
3 Uplink / Stacking module 4 7 Power supply unit 1
4 Uplink / Stacking module 3
Brocade ICX 7450 slot and Ethernet port numbering
Brocade ICX 7450 Hardware Installation Guide 7
53-1003623-02
1
Brocade ICX 7450 slot and Ethernet port numbering
Many CLI commands require users to enter port numbers as part of the command syntax, and
many show command outputs display port numbers. The port numbers are entered and displayed
in stack-unit/slot number/port number format.
The Brocade ICX 7450 contains the following slots and Ethernet ports:
Slot 1 and Slot 2 are located on the front of the Brocade ICX 7450-24 and ICX 7450-24P
devices. Slot 1 contains 1 GbE RJ-45 ports 1/1/1 through 1/1/24, with odd port numbers on
the top row and port 1/1/1 on the left. Slot 2 contains 1/10 GbE SFP+ ports 1/2/1 and 1/2/3
on the top row (left to right), and ports 1/2/2 and 1/2/4 on the bottom row (left to right). Refer
to the following figure.
FIGURE 7 Brocade ICX 7450-24 and ICX 7450-24P slot numbering
Slot 1 and Slot 2 are located on the front of the Brocade ICX 7450-48 and ICX 7450-48P
devices. Slot 1 contains 1 GbE RJ-45 ports 1/1/1 through 1/1/48, with odd port numbers on
the top row and port 1/1/1 on the left. Slot 2 contains 1/10 GbE SFP+ ports 1/2/1 and 1/2/3
on the top row (left to right), and ports 1/2/2 and 1/2/4 on the bottom row (left to right). Refer
to the following figure.
FIGURE 8 Brocade ICX 7450-48 and ICX 7450-48P slot numbering
Slot 1 and Slot 2 are located on the front of the Brocade ICX 7450-48F device. Slot 1 contains
1 GbE SFP ports 1/1/1 through 1/1/48, with odd port numbers on the top row and port 1/1/1
on the left. Slot 2 contains 1/10 GbE SFP+ ports 1/2/1 and 1/2/3 on the top row (left to
right), and ports 1/2/2 and 1/2/4 on the bottom row (left to right). Refer to the following
figure.
FIGURE 9 Brocade ICX 7450-48F slot numbering
8Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
1Supported expansion modules
Slot 3 is located on the rear of the Brocade ICX 7450 switch and with a single-port module
installed contains 40 GbE QSFP+ stacking/data port 1/3/1, With a 4-port module installed,
Slot 3 contains 1/10 GbE SFP+ ports 1/3/1 and 1/3/3 on the top row (left to right), and ports
1/3/2 and 1/3/4 on the bottom row (left to right). Refer to Figure 10.
Slot 4 is also located on the rear of the Brocade ICX 7450 switch and with a single-port module
installed contains 40 GbE QSFP+ stacking/data port 1/4/1, With a 4-port module installed,
Slot 4 contains 1/10 GbE SFP+ ports 1/4/1 and 1/4/3 on the top row (left to right), and ports
1/4/2 and 1/4/4 on the bottom row (left to right). Refer to Figure 10.
FIGURE 10 Brocade ICX 7450 rear slot numbering
Supported expansion modules
A 4-port 1GbE SFP expansion module can be purchased and installed in the slots shown in Table 2
on page 8 and Table 3 on page 9. The expansion module supports 1 GbE optics (refer to the
Brocade Optics Family Data Sheet).
A 4-port 1/10GbE SFP+ expansion module can be purchased and installed in the slots shown in
Table 2 on page 8 and Table 3 on page 9. The expansion module supports 1 GbE and 10 GbE
optics (refer to the Brocade Optics Family Data Sheet).
A 4-port 1/10GbE copper expansion module can be purchased and installed in the slots shown in
Table 2 on page 8 and Table 3 on page 9. The expansion module supports 1 GbE and 10 GbE
copper wired connections.
A 1-port 40GbE QSFP+ expansion module can be purchased and installed in the slots shown in
Table 2 on page 8 and Table 3 on page 9. The expansion module supports 40 GbE optics. This
module can be used for data uplink or stacking.
TABLE 2 Brocade ICX 7450-24 and 24P expansion slots and supported media modules
Module Slot 2 Slot 3 Slot 4
ICX7400-4X1GF 4X1G 4X100M 4X1G 4X100M 4X1G 4X100M
Yes Yes No No No No
ICX7400-4X10GF 4X10G 4X1G 4X10G 4X1G 4X10G 4X1G
Yes Yes Yes Yes Yes Yes
ICX7400-4X10GC 4X10G 4X1G 4X10G 4X1G 4X10G 4X1G
Yes Yes Yes Yes Yes Yes
ICX7400-1X40GQ 40G 4X10G 40G 4X10G 40G 4X10G
Yes No Yes No Yes No
TABLE 3 Brocade ICX 7450-48, 48P and 48F expansion slots and supported media modules
Module Slot 2 Slot 3 Slot 4
ICX7400-4X1GF 4X1G 4X100M 4X1G 4X100M 4X1G 4X100M
Yes Yes No No No No
ICX7400-4X10GF 4X10G 4X1G 4X10G 4X1G 4X10G 4X1G
Yes Yes Yes Yes Yes Yes
ICX7400-4X10GC 4X10G 4X1G 4X10G 4X1G 4X10G 4X1G
Yes Yes Yes Yes Yes Yes
ICX7400-1X40GQ 40G 4X10G 40G 4X10G 40G 4X10G
No No Yes No Yes No
Supported transceivers and cables
Brocade ICX 7450 Hardware Installation Guide 9
53-1003623-02
1
Instructions for installing or replacing an expansion module are described in “Replacing an
expansion module” on page 53.
FIGURE 11 40 GbE QSFP+ expansion module
NOTE
Pull the release lever down before removing a media or stacking module.
Supported transceivers and cables
For a list of supported transceivers and cables, refer to the Brocade Optics Family Data Sheet.
1Release lever latch 3QSFP+ slot
2 Module slot LEDs 4 Expansion module power LED
10 Brocade ICX 7450 Hardware Installation Guide
53-1003623-02
1Supported transceivers and cables
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94

Brocade Communications Systems ICX 7450 series Hardware Installation Manual

Category
Network switches
Type
Hardware Installation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI