3
©2017 Hubbell Incorporated | Chance® Snatch Block Installation Instructions
Installation
ALWAYS insure that lok pin is fully inserted into appropriate hole. Pin must require a minimum of
4 lbs. (17.8 N) pull out force to remove from hole. If less than 4 lbs. DO NOT USE. Unintentional
dislodging of pin could result in SERIOUS INJURY or DEATH and damage to the load if the Snatch
Block opens and drops the load.
ALWAYS insure that the safety latch is fully closed against the hook before applying the load.
Failure to do so could result in SERIOUS INJURY or DEATH and DAMAGE to the load if the Snatch
Block falls from the mounting point.
Do not use Snatch Block if safety latch or lok pin do not operate properly. Tag Block “Dangerous,
Do Not Use” and remove from service until it can be inspected.
1. Remove lok pin to install fiber rope on sheave
or feed rope through available space without
removing Lok Pin. Ensure that the lok pin is
reinstalled properly after installation of rope.
See Figure 1.
2. Secure Snatch block to structure capable of
supporting the load being lifted. Ensure that the
safety latch is fully closed after securing Snatch
Block. See Figure 2.
A. Properly installed lok pin.
A. Fully Closed Safety Latch B. Safety latch not fully
closed. DO NOT USE.
C. Properly functioning
lok pin.
B. Incorrect installation of lok
pin. DO NOT USE.
D. Malfunctioning
lok pin.
DO NOT USE.
!
WARNING
!
WARNING
!
WARNING
DATEEC # CHG BY RESP ENG
DESC OF CHANGES:
REASON FOR CHANGE:
DISPOSITION OF MAT'L:
AREAS AFFECTED
BY LATEST EC
No
No
No
No
No
No
No
No
- - - -
CHANCE
TOLERANCE CHART
.X .060 FRAC 1/16 ANGLES 2
.XX .030 ADD DRAFT (UNLESS NOTED)
.XXX
.005 CASTINGS 3 FORGINGS 7
CONFIDENTIAL: THIS DRAWING AND ITS
CONTENTS ARE CONFIDENTIAL AND THE
EXCLUSIVE PROPERTY OF HUBBELL POWER
SYSTEMS. NO PUBLICATION, DISTRIBUTION, OR
COPIES MAY BE MADE WITHOUT THE WRITTEN
CONSENT OF HUBBELL POWER SYSTEMS. HUBBELL
POWER SYSTEMS UNPUBLISHED ALL RIGHTS
RESERVED UNDER THE COPYRIGHT LAWS.
TITLE
SIZE
DWG NO.CAT / PART / ASSY NO.
REV
DO NOT SCALE
THIS DRAWING
DRN BY DATE SHEET
B
HUBBELL POWER SYSTEMS, INC.
-
1 OF 1 GKT
-
-
-
-
-
-
-
POWER SYSTEMS, INC.
THIS SYMBOL IDENTIFIES
CRITICAL FEATURES
CF
S.P.C.
F.A.I.
SUPPLIER
GAUGES
TOOL/EQUIP
PRCS PROC
PKG/LABEL
INSP/TEST
-
-NOTES-
1. .025" RAISED LETTERING
3.4" (86.36 mm) REF
2 . 8 "
(71.12 mm) REF
1.0" (25.4 mm) REF
SAFETY LATCH
6 . 4 "
(162.56 mm) REF
4" (101.6 mm) REF
DATEEC # CHG BY RESP ENG
DESC OF CHANGES:
REASON FOR CHANGE:
DISPOSITION OF MAT'L:
AREAS AFFECTED
BY LATEST EC
No
No
No
No
No
No
No
No
- - - -
CHANCE
TOLERANCE CHART
.X
.060 FRAC 1/16 ANGLES 2
.XX .030 ADD DRAFT (UNLESS NOTED)
.XXX
.005 CASTINGS 3 FORGINGS 7
CONFIDENTIAL: THIS DRAWING AND ITS
CONTENTS ARE CONFIDENTIAL AND THE
EXCLUSIVE PROPERTY OF HUBBELL POWER
SYSTEMS. NO PUBLICATION, DISTRIBUTION, OR
COPIES MAY BE MADE WITHOUT THE WRITTEN
CONSENT OF HUBBELL POWER SYSTEMS. HUBBELL
POWER SYSTEMS UNPUBLISHED ALL RIGHTS
RESERVED UNDER THE COPYRIGHT LAWS.
TITLE
SIZE
DWG NO.CAT / PART / ASSY NO.
REV
DO NOT SCALE
THIS DRAWING
DRN BY DATE SHEET
B
HUBBELL POWER SYSTEMS, INC.
-
1 OF 1 GKT
-
-
-
-
-
-
-
POWER SYSTEMS, INC.
THIS SYMBOL IDENTIFIES
CRITICAL FEATURES
CF
S.P.C.
F.A.I.
SUPPLIER
GAUGES
TOOL/EQUIP
PRCS PROC
PKG/LABEL
INSP/TEST
-
-NOTES-
1. .025" RAISED LETTERING
3.4" (86.36 mm) REF
2 . 8 "
(71.12 mm) REF
SAFETY LATCH
DATEEC # CHG BY RESP ENG
DESC OF CHANGES:
REASON FOR CHANGE:
DISPOSITION OF MAT'L:
AREAS AFFECTED
BY LATEST EC
No
Yes
Yes
No
No
No
No
No
- - - -
CHANCE
TOLERANCE CHART
.X .060 FRAC 1/16 ANGLES 2
.XX .030 ADD DRAFT (UNLESS NOTED)
.XXX
.005 CASTINGS 3 FORGINGS 7
CONFIDENTIAL: THIS DRAWING AND ITS
CONTENTS ARE CONFIDENTIAL AND THE
EXCLUSIVE PROPERTY OF HUBBELL POWER
SYSTEMS. NO PUBLICATION,
DISTRIBUTION, OR
COPIES MAY BE MADE WITHOUT THE WRITTEN
CONSENT OF HUBBELL POWER SYSTEMS. HUBBELL
POWER SYSTEMS UNPUBLISHED ALL RIGHTS
RESERVED UNDER THE COPYRIGHT LAWS.
TITLE
SIZE
DWG NO.CAT / PART / ASSY NO.
REV
DO NOT SCALE
THIS DRAWING
DRN BY DATE SHEET
A
HUBBELL POWER SYSTEMS, INC.
-
1 OF 1 GKT
-
-
-
-
-
-
-
POWER SYSTEMS, INC.
THIS SYMBOL IDENTIFIES
CRITICAL FEATURES
CF
S.P.C.
F.A.I.
SUPPLIER
GAUGES
TOOL/EQUIP
PRCS P
ROC
PKG/LABEL
INSP/TEST
-
DATEEC # CHG BY RESP ENG
DESC OF CHANGES:
REASON FOR CHANGE:
DISPOSITION OF MAT'L:
AREAS AFFECTED
BY LATEST EC
No
Yes
Yes
No
No
No
No
No
- - - -
CHANCE
TOLERANCE CHART
.X .060 FRAC 1/16 ANGLES 2
.XX .030 ADD DRAFT (UNLESS NOTED)
.XXX
.005 CASTINGS 3 FORGINGS 7
CONFIDENTIAL: THIS DRAWING AND ITS
CONTENTS ARE CONFIDENTIAL AND THE
EXCLUSIVE PROPERTY OF HUBBELL POWER
SYSTEMS. NO PUBLICATION,
DISTRIBUTION, OR
COPIES MAY BE MADE WITHOUT THE WRITTEN
CONSENT OF HUBBELL POWER SYSTEMS. HUBBELL
POWER SYSTEMS UNPUBLISHED ALL RIGHTS
RESERVED UNDER THE COPYRIGHT LAWS.
TITLE
SIZE
DWG NO.CAT / PART / ASSY NO.
REV
DO NOT SCALE
THIS DRAWING
DRN BY DATE SHEET
A
HUBBELL POWER SYSTEMS, INC.
-
1 OF 1 GKT
-
-
-
-
-
-
-
POWER SYSTEMS, INC.
THIS SYMBOL IDENTIFIES
CRITICAL FEATURES
CF
S.P.C.
F.A.I.
SUPPLIER
GAUGES
TOOL/EQUIP
PRCS P
ROC
PKG/LABEL
INSP/TEST
-
FIGURE 1. LOK PIN INSTALLATION
FIGURE 2. SAFETY LATCH
DATEEC # CHG BY RESP ENG
DESC OF CHANGES:
REASON FOR CHANGE:
DISPOSITION OF MAT'L:
AREAS AFFECTED
BY LATEST EC
No
No
No
No
No
No
No
No
- - - -
CHANCE
TOLERANCE CHART
.X .060 FRAC 1/16 ANGLES 2
.XX .030 ADD DRAFT (UNLESS NOTED)
.XXX
.005 CASTINGS 3 FORGINGS 7
CONFIDENTIAL: THIS DRAWING AND ITS
CONTENTS ARE CONFIDENTIAL AND THE
EXCLUSIVE PROPERTY OF HUBBELL POWER
SYSTEMS. NO PUBLICATION, DISTRIBUTION, OR
COPIES MAY BE MADE WITHOUT THE WRITTEN
CONSENT OF HUBBELL POWER SYSTEMS. HUBBELL
POWER SYSTEMS UNPUBLISHED ALL RIGHTS
RESERVED UNDER THE COPYRIGHT LAWS.
TITLE
SIZE
DWG NO.CAT / PART / ASSY NO.
REV
DO NOT SCALE
THIS DRAWING
DRN BY DATE SHEET
B
HUBBELL POWER SYSTEMS, INC.
-
1 OF 1 GKT
-
-
-
-
-
-
-
POWER SY STEMS, INC.
THIS SYMBOL IDENTIFIES
CRITICAL FEATURES
CF
S.P.C.
F.A.I.
SUPPLIER
GAUGES
TOOL/EQUIP
PRCS PROC
PKG/LABEL
INSP/TEST
-
-NOTES-
1. .025" RAISED LETTERING
3.4" (86.36 mm) REF
2 . 8 "
(71.12 mm) REF
SAFETY LATCH
DATEEC # CHG BY RESP ENG
DESC OF CHANGES:
REASON FOR CHANGE:
DISPOSITION OF MAT'L:
AREAS AFFECTED
BY LATEST EC
No
No
No
No
No
No
No
No
- - - -
CHANCE
TOLERANCE CHART
.X .060 FRAC 1/16 ANGLES 2
.XX .030 ADD DRAFT (UNLESS NOTED)
.XXX
.005 CASTINGS 3 FORGINGS 7
CONFIDENTIAL: THIS DRAWING AND ITS
CONTENTS ARE CONFIDENTIAL AND THE
EXCLUSIVE PROPERTY OF HUBBELL POWER
SYSTEMS. NO PUBLICATION, DI
STRIBUTION, OR
COPIES MAY BE MADE WITHOUT THE WRITTEN
CONSENT OF HUBBELL POWER SYSTEMS. HUBBELL
POWER SYSTEMS UNPUBLISHED ALL RIGHTS
RESERVED UNDER THE COPYRIGHT LAWS.
TITLE
SIZE
DWG NO.CAT / PART / ASSY NO.
REV
DO NOT SCALE
THIS DRAWING
DRN BY DATE SHEET
B
HUBBELL POWER SYSTEMS, INC.
-
1 OF 1 GKT
-
-
-
-
-
-
-
POWER SYSTE MS, INC.
THIS SYMBOL IDENTIFIES
CRITICAL FEATURES
CF
S.P.C.
F.A.I.
SUPPLIER
GAUGES
TOOL/EQUIP
PRCS PRO
C
PKG/LABEL
INSP/TEST
-
-NOTES-
1. .025" RAISED LETTERING
3.4" (86.36 mm) REF
2.8 "
(71.12 mm) REF
PS400006 LOK PIN
SAFETY LATCH