GUIDE TO SELECTING FUNCTIONS
Functions and settings
Other abnormal appliance operations displayed
by indicator lamps.
In case of abnormal appliance operation, all the temperature
selection indicator lamps will flash and a beep will sound.
After pressing and holding the alarm deactivation "
RESET
"
button, the beep will stop and the indicator lamps will light
up, allowing for determining the alarm code (in accordance
with the following table listing possible alarm codes).
When the "
RESET
" is released, the indicator lamps will flash
until the fault is eliminated. If any alarm from the table below
occurs, other functions such as temperature adjustment and
fast freezing are not available until the fault is eliminated.
When several alarms occur simultaneously, the alarm with the
highest priority is displayed. (Code 01 is the highest priority.)
After determining the alarm code (between 01 and 04):
•
The user can eliminate the reason of the code 04 alarm by
closing the door completely.
•
Code 03 alarm - The alarm deactivates when the minimum
required temperature is reached.
•
The other alarms (code 01, 02) - Contact the After-Sales
Service and provide the alarm code.
How can increase the freezer compartment capacity
In certain models you can increase the freezer compartment
capacity by:
- Removing the shelf with the turntable.
- Removing the turntable only.
Please refer to the figures beside to see how to proceed.
How to make ice cubes
Depending on the model:
With a turntable and ice-cube trays
•
Remove the turntable, fill the trays with water to approx. 3/
4 and place back in the appliance.
•
The ice-cubes will be automatically ejected into the
container after turning the ice-cube tray knobs
With an ice-cube tray
•
Fill the ice-cube tray with water to approx. 3/4 and insert it
into the SFF section of the freezer compartment.
•
Do not use any sharp or cutting items to remove the tray.
Alarm off button
Fast Freezing
: Activate this function before freezing
fresh products. To activate this function, press the
“
Fast Freezing
”
- All 3 green indicator lamps on the panel will light
up simultaneously. This function is automatically
disabled after 18 hours. To deactivate it earlier:
- Press the “
Fast Freezing
” button again - the
temperature selection indicator lamps will return
to the previously set temperature level, or.
- Press the temperature selection button in the
freezer compartment.
Temperature selection - It is possible to select
between 3 levels of the freezer temperature
(minimum, medium, maximum) by
pressing the temperature selection button .
The “
Anti-Bacterial Filter
” - alarm, signalled by the
continuous yellow indicator lamp (2), indicates the
need to replace the filter. After replacing the filter
press the “
RESET
” button for approx. 5
seconds until the indicator lamp goes off.
“
Black-out
”
Alarm -
in case of power failure, the
appliance automatically monitors the temperature
changes in the freezer compartment. After the
power supply returns,- the
“Black-out”
alarm will
activate, if the temperature has risen above the
admissible level. This is indicated by:
- Flashing of the yellow indicator lamp (2).
- Activation of a beep.
When the “
Black-out
” alarm is active, it is
recommended to proceed as follows:
- If the food in the freezer is not frozen but is still
cold, transfer it promptly to the refrigerator
compartment and consume within 24 hours.
- If the food in the freezer is frozen, it has re-frozen
after thawing caused by the power failure.
Consumption of re-frozen food is not
recommended since it lost its nutritive value and
may be hazardous to your health.
Note:
The “
Black-out
” alarm does not guarantee
the food quality and its safety in case of consumption.
It merely indicates the necessity to assess the quality
of food in the freezer andrefrigerator compartments.
To deactivate the alarm, press the “
RESET
”
button for approximately 3 seconds, until the
indicator light goes off.
The temperature will return to the normal operating
cycle level and the beep will silence.
Alarm priority Alarm
code
Te m p e r a t u r e
setting indicator lamps on
minimum
MIN
medium
MED
maximum
MAX
Evaporator sensor failure 01 No
Yes
No
Freezer sensor failure 02
Yes
No No
High freezer compartment
temperature alarm
03
Yes Yes
No
Open door alarm 04
Yes Yes Yes
5019 636 01001