Extron FOX T USW 203 User manual

Category
Video switches
Type
User manual
User Guide
FOX T USW 203
Fiber Optic Switcher
Three Input Universal Switcher
with an Integrated Fiber Optic Transmitter
68-2226-01 Rev. B
12 14
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit
d’une tension électrique dangereuse susceptible de provoquer un choc
électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation,
la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les
informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site
Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind
und die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise
zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad de
Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: www.extron.com,
номер по каталогу - 68-290-01.
Chinese Simplified(简体中文)
警告 产品上的这个标志意在警告用户产品机壳内有暴露的危险
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
Chinese Traditional )
警告: 若產品上使用此符號,是為了提醒使用者產品機殼內存
可能會導致觸電之風險的未絕緣危險電壓
注意 若產品上使用此符號是為使用者設備隨附的用戶手冊中有
要的操作和維護(維修説明
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳
細資訊,請瀏覽 Extron 網站:www.extron.com,然後參閱《Extron 安全性
與法規遵守手冊》,準則編號 68-290-01。
Japanese
警告: この が製品上に示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があるこを示ています
意: この 製品上に表示されている場合は、の取扱説明
( )
意を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01)ご覧ださい。
Korean
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
Copyright
© 2014 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
®
, registered service marks
(SM)
, and trademarks
(TM)
are the property of
RGBSystems, Inc. or Extron Electronics:
Registered Trademarks
(®)
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, GlobalViewer, Hideaway, Inline, IPIntercom,
IPLink, KeyMinder, LockIt, MediaLink, PlenumVault, PoleVault, PowerCage, Pure3, Quantum, SoundField, SpeedMount, SpeedSwitch,
SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTP Systems
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassDRippleSuppression),
DDSP (Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital Sync
Validation Processing), DTP, eLink, EQIP, FastBite, FlexOS, FOXBOX, GlobalConfigurator, IP Intercom HelpDesk, LinkLicense, MAAP,
MicroDigital, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Scope-Trigger, SIS - Simple Instruction Set, Skew-Free, SpeedNav,
Triple-Action Switching, WebShare, XTRA, ZipCaddy, ZipClip
FDA/IEC 60825-1 Requirements
CLASS 1 LASER PRODUCT
Complies with FDA performance standards for laser products except for deviations pursuant to Laser
Notice No. 5, dated June 24, 2007.
The product is intended to be used with the fiber optic cables fully installed.
This product meets the applicable requirements of IEC 60825-1, Edition 1 (2007).
Any service to this product must be carried out by Extron Electronics and its qualified service
personnel.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility,
accessibility, and related topics, see the “Extron Safety and Regulatory Compliance Guide
on the Extron website.
FDA/IEC 60825-1 Prérequis
Produit laser de classe1
Conforme aux standards de performance FDA pour les produits laser, sauf pour d’éventuelles
modifications, conformément à la «Laser Notice» numéro 5, datant du 24 juin 2007.
Le produit est conçu pour être utilisé avec les câbles fibre optique entièrement installés.
Ce produit répond aux prérequis applicables de l’IEC 60825-1, 1ère Édition (2007).
Si ce produit a besoin d’un quelconque entretient, celui-ci doit être fait par ExtronElectronics et son
personnel qualifié.
Remarque : Pour plus d'informations sur les directives de sécurité, les conformités de régulation,
la compatibilité EMI/EMF, l'accessibilité, et les sujets en lien, consultez le «Informations de
sécurité et de conformité Extron» sur le site internet d'Extron.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT: Risque potentiel de blessure grave ou de mort.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E X! *X1&* X2)* X2#* X2! CE}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” is the capital
letter “o.”
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
viiFOX T USW 203 Universal Switcher • Contents
Contents
Introduction............................................................ 1
About this Guide ................................................. 1
About the FOX T USW 203 Universal Switcher ... 1
System Compatibility ...................................... 2
Cable Transmission Modes ............................. 2
Key Features ...................................................... 2
Installation .............................................................. 4
Installation Overview ........................................... 4
Rear Panel Features ........................................... 4
Input Connectors ............................................ 5
Output Connectors ......................................... 5
RS-232 Over Fiber and Alarm Connector........ 6
Control Connectors ........................................ 7
Power Connector ........................................... 7
Connection Details ............................................. 7
Connecting HDMI Connectors ........................ 7
Wiring for RS-232 Over Fiber and Alarm
Communication ............................................. 8
Wiring for Remote Contact Closure
Communication ............................................. 9
Wiring the Power Supply ................................ 9
Operation .............................................................. 11
Front Panel Features ......................................... 11
Front Panel Operation ....................................... 11
Initial Power Up............................................. 11
Selecting an Input ......................................... 12
Setting the Front Panel Lockout Mode
(Executive Mode) ......................................... 12
Setting Switch Modes ................................... 12
SIS Configuration and Control ........................ 13
Simple Instruction Set Control .......................... 13
SIS Programming Guide ............................... 13
Error Responses ........................................... 14
Using the Command and Response Table
for SIS Commands ...................................... 14
Symbol Definitions ........................................ 14
Command and Response Tables for SIS
Commands ..................................................... 16
Input Switching Commands .......................... 16
Audio Configuration Commands ................... 16
Picture Adjustments Commands
(Analog Only) .............................................. 17
EDID Commands .......................................... 18
Advanced Configurations Commands........... 18
FOX Extenders Control Program .................... 21
Installing the Software ....................................... 21
Starting the Software ........................................ 22
Using the Software ........................................... 22
Menu Bar ..................................................... 23
Main Screen ................................................. 30
Reference Information ...................................... 38
Mounting .......................................................... 38
Tabletop Use ................................................ 38
Mounting Kits ............................................... 38
Updating Firmware ........................................... 39
Downloading Extron Firmware Loader .......... 39
Installing Firmware Loader ............................ 40
Downloading Firmware ................................. 40
Installing Firmware with Firmware Loader ...... 41
FOX T USW 203 Universal Switcher • Contents viii
FOX T USW 203 Universal Switcher • Introduction 1
Introduction
This section contains general information about this guide and the FOX T USW 203 Universal
Switcher with an integrated fiber optic transmitter, selected device features, and a typical
application diagram. Topics in this section include:
About this Guide
About the FOX T USW 203 Universal Switcher
Key Features
About this Guide
This guide describes installation, operation, and control procedures, and reference
information for the FOX T USW 203 Universal Switcher with an integrated fiber optic
transmitter. In this guide, the terms “FOX T USW 203” and “switcher” are used
interchangeably to refer to any model of the FOX T USW 203 Universal Switcher in
singlemode or multimode.
About the FOX T USW 203 Universal Switcher
The Extron FOX T USW 203 is a three input universal switcher with an integrated fiber optic
transmitter that provides long haul transmission of HDCP-compliant HDMI, RGBHV, or HD
component video, stereo audio, and RS-232 signals over fiber optic cabling. It delivers
pixel-for-pixel transmission of images up to 1920x1200 and 2K, including HDTV 1080p
@ 60 Hz.
To configure and control the FOX T USW 203, connect a computer and enter Simple
Instruction Set (SIS) commands (see SIS Configuration and Control on page 13) or use the
FOX Extenders Control Program (see FOX Extenders Control Program on page 21).
12V
1.0A MAX
FOX SR HDMI
POWER
LINK
LINK
OPTICAL
Rx
Tx
HDMI AUDIO
HDMI
AUDIO
OUTPUTS
ON
OFF
REMOTE
RS-232
Tx Rx
RS-232
OVER FIBER
ALARM
Tx Rx 1 2
L R
S
TANDBY
CLASS 2 WIRING
1
2
XPA 1002
LE
VEL
1
1
2
1
2
LIMIT
ER/
PROTECT
SIGNAL
2
INPUTS
OUTPUT
REMOT
E
0
0
VOL/MUTE
10
V 5
0 m
A
1
00-24
0V
1
.3A, 5
0-60H
z
FOX T USW 203
RS-232CONTACT
RS-232
OVER FIBER
AUDIO
HDMI
HDMI
LOOP-THRU
ALARM
REMOTE
Tx Rx
Tx Rx
OPTICAL
INPUTS
1
POWER
12V
0.7 A MAX
2
3
LINK
LINK
G Tx Rx G1 2 1 2 3 G
RGB/R-Y, Y, B-Y
OUTPUTS
Extron
FOX T USW 203
Fiber Optic Switcher
1
31
42
31
42
3
1
4
2
2
3
1
0
0
L
I
NK
ACT
C
O
M
IR
INPUT
RE
L
AY
T
X
R
X
R
IPL
250
®
O
N
O
F
F
DISP
LAY
MUTE
S
C
R
E
E
N
UP
SC
R
E
E
N
DOW
N
VC
R
D
VD
DO
C
CAM
LA
P
TOP
P
C
TCP/IP
TouchLink
Control
System
RS-232
RS-232
Extron
FOXBOX SR HDMI
Fiber Optic Receiver
Flat Panel Display
Flat Panel Display
VGA PC
HDMI
La
ptop
Blu-ray Player
Up to 30 km
(18.75 miles)
singlemode ber
SM Model
HDMI
HDMI
+ Audio
HDMI
+ Audio
VGA
Audio
Audio
Output
RS-232
Extron
XPA 1002
Power
Amplier
Extron
SI 28
Surface-moun
t
Speakers
Figure 1. Typical FOX T USW 203 Application
FOX T USW 203 Universal Switcher • Introduction 2
WARNING: Potential risk of severe injury. The FOX T USW 203 outputs continuous
invisible light, which may be harmful to the eyes; use with caution.
AVERTISSEMENT: Risque potentiel de blessure grave ou de mort. Le
FOX T USW 203 émet une lumière invisible en continu qui peut être dangereux pour
les yeux, à utiliser avec précaution.
Do not look into the rear panel fiber optic cable connectors or into the fiber optic
cables themselves.
Ne regardez pas dans les connecteurs de câble fibre optique sur le panneau arrière
ou dans les câbles fibre optique eux-mêmes.
Plug the attached dust caps into the optical transceivers when the fiber cable is
unplugged.
Branchez les protections contre la poussière dans l’ensemble émetteur/récepteur
lorsque le câble fibre optique est débranché.
System Compatibility
The FOX T USW 203 supports Plus or Non-Plus mode transmission for compatibility with
FOX receivers. Devices in Plus mode are only compatible with other devices in Plus mode.
Use SIS commands (see Plus mode transmission on page 19) or the FOX Extenders
Control Program (see Plus Mode Transmission panel on page 34) to change the mode.
Non-Plus — Supports resolutions from 640x480 up to 1600x1200 @ 60 Hz, including
480p up to 1080p @ 60 Hz. Embedded audio is not supported, but analog audio is
supported and HDCP compliant.
Plus — Supports all resolutions supported in non-plus mode, plus 1920x1200 and
2K (2048x1080) @ 60 Hz. Embedded audio and analog audio are supported and are
both HDCP compliant.
Supported Receivers
Plus Mode Non-Plus Mode
FOXBOX Rx DVI Plus FOXBOX Rx VGA
FOXBOX Rx HDMI FOXBOX Rx DVI
FOXBOX SR HDMI FOX 500 DVI Rx
PowerCage FOX Rx DVI Plus FOX 500 Rx
PowerCage FOX Rx HDMI PowerCage FOX Rx VGA
PowerCage FOX SR HDMI PowerCage FOX Rx DVI
FOX II R DP
Cable Transmission Modes
The switcher is further categorized by the type of fiber optic cable, multimode (MM) or
singlemode (SM), which define the effective range of transmission
Multimode — Long distance, up to 2 km (6,560 feet) (depending on the fiber cable)
Singlemode — Very long distance, up to 30 km (18.75 miles)
Key Features
Long distance fiber optics transmission — Transmits HDMI or analog video, stereo
audio, and RS-232 signals up to 30 km when using singlemode fiber optic cabling.
Inputs — Include two female HDMI type-A connectors, one RGBHV/RGBS or HD
component on 15-pin HD connector, and one unbalanced analog stereo audio on a 3.5 mm
stereo mini-jack.
FOX T USW 203 Universal Switcher • Introduction 3
All digital technology — Delivers pixel-for-pixel transmission of video signals to ensure
optimal image quality at resolutions up to 1920x1200 and 2K, including HDTV 1080p
@ 60 Hz.
Digital conversion of analog video and audio input signals — Digitizes analog signals,
ensuring that a reliable, high quality digital video signal is sent to the output destination.
Auto-input switching — Automatically switches to the highest or lowest priority input with
an active video signal for simplified operation.
HDCP-compliance
Key Minder — Authenticates and maintains continuous HDCP encryption between input
and output devices to ensure quick and reliable switching in professional AV environments,
while enabling simultaneous distribution of a single source signal to one or more displays.
EDID Minder — Automatically manages EDID communication between connected devices
to ensure that all sources properly power up and reliably display content.
Audio embedding — Converts analog stereo audio signals to digital HDMI audio when the
analog input is selected.
Audio gain and attenuation adjustment capability
LED indicators for signal presence, HDCP, and power — Provides a visual indication of
system status for real-time feedback and monitoring of key performance parameters.
RS-232 control — Features an RS-232 serial port for control and configuration.
Contact closure remote control availability
Alarm notification for fiber link loss — The FOX T USW 203 can be set up to trigger an
external control system for immediate notification when a fiber link has been lost. Requires a
second fiber link.
Multimode and singlemode availability — Available as an 850 nm multimode model for
long-range transmissions up to 2 km (6,560 feet), and a 1310 nm singlemode model for
extreme distances up to 30 km (18.75 miles).
Industry standard LC connectors — Provide reliable physical connectivity and precise
fiber core alignment.
Compatibility with the following Extron FOX series:
Matrix switchers — Creates HDCP-compliant signal distribution systems up to
1000x1000 and larger.
DisplayPort, HDMI, DVI Plus, DVI, and VGA receivers — Compatible with FOX
series DisplayPort, HDMI, and DVI Plus receivers up to 1920x1200 and 2K, including
HDTV 1080p/60. Compatible with FOX series DVI and VGA receivers up to 1600x1200,
including HDTV 1080p/60.
NOTE: The FOX T USW 203 is not compatible with the FOX 3G HD-SDI, FOX 3G DVC,
or FOX AV models.
Front panel USB configuration port
1U high, half rack width metal enclosure — Compact, low profile enclosure for discreet
placement and concealment.
Includes LockIt
®
HDMI cable lacing bracket
Energy-efficient external universal power supply included — Provides worldwide
compatibility, low power consumption, and reduced operating costs.
FOX T USW 203 Universal Switcher • Installation 4
Installation
This section describes information for connecting and wiring the FOX T USW 203. Topics in
this section include:
Installation Overview
Rear Panel Features
Connection Details
Installation Overview
Follow these steps to install and set up an Extron FOX T USW 203 in a fiber optic system:
1. Turn off all of the equipment. Ensure that the video sources and output display are all
turned off and disconnected from the power source.
NOTE: For proper equipment cooling, do not stack units in a rack.
2. Mount the switcher (see Mounting on page 38).
3. Connect the cables (see Rear Panel Features below).
4. Configure the switcher (see SIS Configuration and Control on page 13 or FOX
Extenders Control Program on page 21).
Rear Panel Features
FOX T USW 203
RS-232CONTACT
RS-232
OVER FIBER
AUDIO
HDMI
HDMI
LOOP-THRU
ALARM
REMOTE
Tx Rx
Tx Rx
OPTICAL
INPUTS
1
POWER
12V
0.8 A MAX
2
3
LINK
LINK
GT
xRxG12 123G
RGB/R-Y, Y, B-Y
OUTPUTS
J B D E F G H IA C
A
Analog video connector (see page 5)
B
Analog video loop-through
connector (see page 5)
C
HDMI input connectors (see page 5)
D
Audio input connector (see page 5)
E
HDMI switched output connector
(see page 5)
F
Fiber optic connector (see page 6)
G
RS-232 and Alarm Over Fiber
connector (see page 6)
H
Contact closure connector (see page 7)
I
Remote RS-232 connector (see page 7)
J
Power connector (see page 7)
Figure 2. FOX T USW 203 Rear Panel Features
FOX T USW 203 Universal Switcher • Installation 5
Input Connectors
A
Analog video connector Connect a video source to the female
15-pin HD connector, labeled input 1 or RGB/R-Y, Y, B-Y.
B
Analog video loop-through connector Connect an analog RGB
or YUV video display to the female 15 HD VGA connector for a local
display of input 1 (VGA). This output is always on.
Selected Video Input VGA Loop-thru Output
VGA (input 1) Always on
HDMI (inputs 2 and 3) N/A
C
HDMI input connectors Connect a source device to either or both
HDMI connectors (see Connecting HDMI Connectors on page 7).
These are inputs 2 and 3. They can accept HDMI DVI (with an
appropriate adaptor), or dual mode DisplayPort video sources.
D
Audio input connector Connect an analog audio source
to the 3.5 mm tip-ring-sleeve (TRS) connector. All three
video inputs can share this audio input.
The following table shows the audio format that is sent over
the fiber connection when a specific audio format is not
specified (see the Audio input selection SIS commands on
page 16 to switch the active audio source).
Selected Video
Input
HDMI Embedded
Audio Present
Analog Audio
Present
Audio Sent Over Fiber
VGA N/A Yes Analog audio
VGA N/A No No audio
HDMI Yes No HDMI embedded audio
HDMI Yes Yes HDMI embedded audio
HDMI No Yes Analog audio
HDMI No No No audio
Output Connectors
E
HDMI switched output connector Connect a display device to the
female type A HDMI output connector for local HDMI output for switched
inputs 1, 2, and 3.
Selected Video Input HDMI Switched Output
VGA (input 1) On (no embedded audio or HDCP compliance)
HDMI (input 2 and 3) On
1
RGB/R-Y, Y, B-Y
LOOP-THRU
HDMI
2
3
Sleeve ( )
Ring (
-
)
Tip (+)
3.5 mm Stereo Plug Connector
(unbalanced)
HDMI
FOX T USW 203 Universal Switcher • Installation 6
F
Fiber optic connector For one-way video, audio, and serial communication from
the FOX T USW 203 to a receiver, connect a fiber optic cable between the Tx port on
the FOX T USW 203 and the Rx port on a compatible receiver.
To return serial data from a receiver to the FOX T USW 203 or for HDCP compliance,
connect a fiber optic cable between the Rx port on the FOX T USW 203 and the Tx port
on the receiver.
WARNING: Potential risk of severe injury. The
FOX T USW 203 outputs continuous invisible light, which may
be harmful to the eyes; use with caution.
AVERTISSEMENT: Risque potentiel de blessure grave ou
de mort. Le FOX T USW 203 émet une lumière invisible en
continu qui peut être dangereux pour les yeux, à utiliser avec
précaution.
Do not look into the rear panel fiber optic cable connectors
or into the fiber optic cables themselves.
Ne regardez pas dans les connecteurs de câble fibre
optique sur le panneau arrière ou dans les câbles fibre
optique eux-mêmes.
Plug the attached dust caps into the optical transceivers
when the fiber cable is unplugged.
Branchez les protections contre la poussière dans
l’ensemble émetteur/récepteur lorsque le câble fibre optique
est débranché.
NOTES:
Ensure that you use the proper fiber optic cable. Typically, singlemode fiber
optic cable has a yellow jacket and multimode fiber optic cable has an orange
or aqua jacket.
Only one fiber optic cable, transmitter-Tx-to-receiver-Rx, is required for video,
audio, and serial command transmission, but the HDMI signal output on the
receiver will not be HDCP-compliant and the FOX T USW 203 will not receive
RS-232 reports from the controlled device.
The Link LED indicators light when there is light presence on either fiber optic port.
RS-232 Over Fiber and Alarm Connector
G
RS-232 Over Fiber connector To pass serial command signals to
a receiver (for serial control of a projector, for example), connect a host
device to the transmitter via the leftmost poles (Tx, Rx, and G) of this
5-pole captive screw connector (see Wiring for RS-232 Over Fiber and
Alarm Communication on page 8 for wiring configurations).
Alarm connector — For remote monitoring of the status of fiber optic
link 2, connect a custom or furnished monitoring device to the switcher via
the rightmost poles (1 and 2) of this 5-pole captive screw connector (see
Wiring for RS-232 Over Fiber and Alarm Communication on page 8).
NOTE: Pins 1 and 2 short within the switcher when link 2 does not detect any
connection.
Tr
ansmitter
to
Receiver
OPTICAL
Rx
Tx
LINK
LINK
OPTICAL
Rx
Tx
LINK
LINK
ALARM
Tx Rx G 1 2
RS-232
OVER FIBER
ALARM
Tx Rx G 1 2
RS-232
OVER FIBER
FOX T USW 203 Universal Switcher • Installation 7
Control Connectors
H
Contact closure connector Connect a contact closure device (such
as a simple switch) to the 3.5 mm, 4-pole captive screw connector.
The first three ports are used for selecting inputs 1 through 3 when
momentarily shorted to the ground pin (see Wiring for Remote Contact
Closure Communication on page 9).
I
Remote RS-232 connector Connect a host device to the 3.5 mm,
3-pole captive screw connector for serial control of the switcher.
Power Connector
J
Power connector Connect an external power supply to the 3.5 mm, 2-pole
captive screw connector (see Wiring the Power Supply on page 9).
Connection Details
Connecting HDMI Connectors
Use an Extron LockIt lacing bracket to secure an HDMI cable to each device.
1. Plug the HDMI cables into the panel connection
(see
1
of the image to the right).
2. Loosen the side HDMI connection mounting screw from
the panel enough to allow the LockIt lacing bracket to
be placed over it (see
2
). The screw does not have to
be removed.
3. Place the LockIt lacing bracket on the screw and
against the HDMI connector, then tighten the screw to
secure the bracket (see
3
).
ATTENTION: Do not overtighten the HDMI
connector mounting screw. The shield to which it is
fastened is very thin and can easily be stripped.
ATTENTION : Ne serrez pas trop la vis de montage
du connecteur HDMI. Le blindage auquel elle
est attachée est très fin et peut facilement être
dénudé.
4. Loosely place the included tie wrap around the HDMI connector and the LockIt lacing
bracket (see
4
).
5. While holding the connector securely against the lacing bracket, use pliers or a similar
tool to tighten the tie wrap, then remove any excess length.
1
2
3
4
CONTACT
12
3G
RS-232
Tx Rx G
POWER
12V
0.8A MA
FOX T USW 203 Universal Switcher • Installation 8
Wiring for RS-232 Over Fiber and Alarm Communication
The RS-232 Over Fiber port is for transmission of serial signals, such as projector control
signals. The alarm port is an internal relay to connect or disconnect a custom alarm circuit.
Wire the connector as shown in figure 3 below.
RxTx
Alarm Device
RS-232 Device
G
RS-232
OVER FIBER ALARM
Tx Rx G12
12
Figure 3. Wiring the RS-232 Over Fiber and Alarm Connector
ATTENTION:
The length of exposed wires in the stripping process is critical. The ideal length is
3/16 inch (5 mm).
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches).
Any longer and the exposed wires may touch, causing a short circuit between
them.
S’ils sont un peu plus longs, les câbles exposés pourraient se toucher et provoquer
un court circuit.
Any shorter and the wires can be easily pulled out even if tightly fastened by the
captive screws.
S’ils sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les
vis captives.
For RS-232 over fiber connection, cross the Tx and Rx lines once between the source and
the target.
The alarm pins do not produce any discrete on or off or voltage signals.
NOTES:
The alarm port does not produce any discrete on or off voltage signals.
If power is lost or if link 2 optical light is disconnected, lost, or broken, alarm pins 1
and 2 internally short.
FOX T USW 203 Universal Switcher • Installation 9
Wiring for Remote Contact Closure Communication
Each port senses an external switch or contact closure. Use these ports to select an input
on the switcher. Wire the connector as shown in figure 4 below.
CONTACT
123G
Ground
Wire Nut
Device 3
Device 2
Device 1
(Switches,
relays, or
similar items)
Switch
1
2
3
G
Heat
Shrink
Over
Shield
Wires
Figure 4. Wiring the Contact Closure Connector
Wiring the Power Supply
Connect a 12 VDC power supply to the 3.5 mm, 2-pole captive screw connector
(see figure 5 below for wiring details).
SECTION A–A
AA
Power Supply
Output Cord
2-Pole Captive Screw
Connector
Ridges
Smooth
Tie
Wrap
3/16”
(5 mm) Max.
Figure 5. Power Connector Wiring
CAUTION: Electric shock hazard. The wires must be kept separate while the power
supply is plugged in. Remove power before wiring.
ATTENTION: Risque de choc électrique: Les deux cordons d’alimentation doivent
être tenus à l’écart l’un de l’autre quand l’alimentation est branchée. Couper
l’alimentation avant de faire l’installation électrique.
FOX T USW 203 Universal Switcher • Operation 11
Operation
This section describes the front panel features of the FOX T USW 203 and describes front
panel operations. Topics in this section include:
Front Panel Features
Front Panel Operation
Front Panel Features
FOX T USW 203
FOX UNIVERSAL SWITCHER
AUTO
SWITCH
MODE
CONFIG
NORMAL
1 2
AUTO
SIGNAL
HDCP
STATUS
3
123
CA B D
Figure 6. FOX T USW 203 Front Panel Features
A
Auto Switch LED indicator Lights when the transmitter is in auto switch mode.
B
Config port Connect a host device to the mini USB Config port for remote control.
C
Input selection buttons Select inputs 1 through 3 or modes of operation. The
corresponding LEDs light to indicate an input is currently active or which mode is
currently active.
D
Status LED indicators The Signal LEDs light to indicate the signal presence of
each input. The HDCP LEDs light when the signal on the corresponding input is HDCP
compliant. Input 1 (the VGA connector) does not have an HDCP LED.
Front Panel Operation
The three buttons with corresponding LEDs on the front panel (labeled Mode, Normal, and
Auto) are used to manually select inputs 1 through 3 or enable and disable device modes
(see the table below). The LEDs indicate status and the currently selected input.
The front panel operations can also be performed remotely with SIS commands (see SIS
Configuration and Control on page 13) or the FOX Extenders Control Program (see FOX
Extenders Control Program on page 21).
Initial Power Up
Upon initial power up, all the front panel LEDs blink simultaneously. They blink once for
multimode or twice for singlemode. Afterwards, the LEDs return to their normal signal
presence indication.
If a different fiber optic SFP module or no SFP module is connected, the LEDs first blink
once or twice to identify the device, but then blink continuously.
FOX T USW 203 Universal Switcher • Operation 12
Selecting an Input
To select an input from the front panel, perform the following actions:
1. Press the input selection button that corresponds with the desired rear panel input
connector.
2. The corresponding LED lights to indicate the active input.
Setting the Front Panel Lockout Mode (Executive Mode)
Push and hold (for about 5 seconds) inputs 1, 2, and 3 simultaneously until the front
panel LEDs blink three times to enable or disable front panel configuration. In executive
mode, contact closure and RS-232 control are still available. By default, executive mode is
disabled.
Setting Switch Modes
The FOX T USW 203 operates in two different switch modes: Normal and Auto Switch. In
Normal switch mode, select inputs from the front panel manually. In Auto Switch mode, an
input is selected automatically based on the active inputs (see the table below for button
combinations).
To enable or disable executive, auto switch, or normal switch mode from the front panel,
press and hold a combination of input selection buttons simultaneously until the appropriate
LEDs blink (see the table below for the different button combinations).
NOTE: Setting audio switch mode to prioritize the lowest numbered active input can be
done only with SIS commands (see Auto switch mode SIS commands on page 16).
Normal switch mode is the default mode.
To enable normal switch mode and disable auto switch mode, push and hold (for about
3 seconds) inputs 1 and 2 until the front panel Auto Switch LED turns off.
Front Panel Button Combinations for Device Modes
Mode Button Combinations
Auto switch (prioritize the highest numbered active input) 1 and 3
Normal switch (default) 1 and 2
FOX T USW 203 Universal Switcher • SIS Configuration and Control 13
SIS Configuration
and Control
This section describes remote control of the FOX T USW 203 through SIS commands
and basic installation instructions for the FOX Extenders Control Program (refer to the FOX
Extenders Control Program Help File for operation details).
To enable serial control of the FOX T USW 203, use a computer running the HyperTerminal
or DataViewer utility, or a control system to make serial control of the transmitter. Connect
the computer to the FOX T USW 203 through the front panel configuration port or the rear
panel RS-232 connector.
The protocol for the RS-232 port is as follows: 9600 baud, no parity, 8 data bits, 1 stop bit,
no flow control.
Simple Instruction Set Control
Command and Response Tables for SIS Commands
Simple Instruction Set Control
SIS Programming Guide
Host-to-device and device-to-host communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the FOX T USW 203 determines that
a command is valid, it executes the command and sends a response to the host device. All
responses from the transmitter or receiver to the host end with a carriage return and a line
feed (CR/LF = ]), which signals the end of the response character string. A string is one or
more characters.
Device-initiated messages
When a local event occurs, the device responds by sending a message to the host. The
device-initiated message may depend on whether the device is multimode or singlemode.
They are listed below.
© Copyright YYYY, Extron Electronics FOX T USW 203 MM, Vx.xx, 60-1230-11
© Copyright YYYY, Extron Electronics FOX T USW 203 SM, Vx.xx, 60-1230-12
YYYY
is a four digit year. Vx.xx is the firmware version number.
Reconfig]
The FOX T USW 203 returns this message when there is any change to the input frequency
on the currently selected input.
1LnkX%2LnkX%Vid X%AudX%X1)TX]
The FOX T USW 203 returns this status message whenever a change in the fiber link, video,
or audio connection occurs. X% indicates whether the link is present or not present
(0 = not present, 1 = present) and X1) represents whether the device is multimode or
singlemode (MM = multimode, SM = singlemode).
FOX T USW 203 Universal Switcher • SIS Configuration and Control 14
Error Responses
When the FOX T USW 203 receives an SIS command and determines that it is valid, it
performs the command and sends the corresponding response to the host device. If the
command is determined invalid or contains invalid parameters, the transmitter or receiver
returns an error response to the host. The error response codes are:
E01 = Invalid input number E14 = Not valid for this configuration
E06 = Invalid switch attempt in this mode E17 = Invalid command for signal type
E10 = Invalid command E22 = Busy
E13 = Invalid parameter
Using the Command and Response Table for SIS Commands
The Command and Response Tables begin on page 16. Lowercase letters are
acceptable in the command field except where indicated. Figure 7 shows the hexadecimal
equivalent of ASCII characters used in the command and response tables.
ASCII to Hex Conversion Table
Space
Figure 7. ASCII to Hexadecimal Conversion
Symbol Definitions
]
= Carriage return and line feed
¦ or }
= Carriage return with no line feed
= Space
E or W
= Escape key
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Extron FOX T USW 203 User manual

Category
Video switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI