Midmark Scavenging Systems Product information

Type
Product information
Quick Reference Guide
Matrx™ Central Scavenger
Waste Anesthetic Gas Disposal System
Model Number:
Serial Number:
Dealer Information:
Purchase Date:
This guide highlights basic operation infor-
mation for the Matrx™ Central Scavenger
System.
Refer to the Matrx™ Central Scavenger
System Installation Manual for more de-
tailed information about the Unit.
If service is required, contact your
authorized Midmark dealer.
Maintenance Limited Warranty
© Midmark Corporation 2008
Once a year inspect the following:
• Outside Vent must be kept free of dirt, snow and
debris including bird, rodent and insect nests.
• Visually inspect the fan for dirt and dust buildup.
Vacuum if necessary.
• Visually inspect power cord and all Scavenging
Hoses for damage. Replace if necessary.
• Test the vacuum levels at each Scavenging Hose
port using the Manometer supplied with the unit.
Follow the instructions printed on the front of the
Manometer.
Vacuum levels registering outside of the pass bands
on the Manometer indicate that the fan needs to be
cleaned, replaced, or that there is a blockage in the
duct work.
Calling for Service
If service is required, contact your Midmark dealer.
To contact Midmark Corporation directly:
1-800-Midmark (1-800-643-6275)
8:00 am - 5:00 pm (EST) Monday through Friday
Wiring Diagram
10593300 Rev C (11/11)
Operation of the Matrx™ Central
Scavenger System is restricted to use in
veterinary procedures performed by
veterinary professionals trained in
anesthesia practice.
Test the vacuum levels at each
Scavenging Hose port using the
Manometer provided with the
product:
A) When a new line is added.
B) When any Trunk Line or Scavenging
Hose line is modified.
C) Yearly to verify performance and
functionality of the equipment.
Note: Instructions for using the Manometer are
printed on the front of the device.
Power Supply
12
VDC
115
VAC
Midmark Corporation (“Midmark”) warrants to the original
purchaser its new Matrx™ Central Scavenger products
and components (except for components not warranted
under “Exclusions”) manufactured by Midmark to be free
from defects in material and workmanship under normal
use and service. Midmark’s obligation under this war-
ranty is limited to the repair or replacement, at Midmark’s
option, of the parts or the products the defects of which
are reported to Midmark within the applicable warranty
period and which, upon examination by Midmark, prove
to be defective.
APPLICABLE WARRANTY PERIOD
The applicable warranty period, measured from the date
of installation for the original user, shall be Five (5) years.
EXCLUSIONS
This warranty does not cover and Midmark shall not be
liable for the following: (1) repairs and replacements
because of misuse, abuse, negligence, alteration, ac-
cident, freight damage, or tampering; (2) products which
are not installed, used, and properly cleaned as required
in the Midmark Installation” manual and or “maintenance”
guide for this applicable product; (3) products considered
to be of a consumable nature; (4) accessories or parts
not manufactured by Midmark; (5) charges by anyone
for adjustments, repairs, replacement parts, installation,
or other work performed upon or in connection with such
products which is not expressly authorized in writing in
advance by Midmark.
EXCLUSIVE REMEDY
Midmark’s only obligation under this warranty is the repair
or replacement of defective parts. Midmark shall not be
liable for any direct, special, indirect, incidental, exempla-
ry, or consequential damages or delay, including, but not
limited to, damages for loss of profits or loss of use.
NO AUTHORIZATION
No person or firm is authorized to create for Midmark any
other obligation or liability in connection with this product.
THIS WARRANTY IS MIDMARK’S ONLY WARRANTY
AND IS IN LIEU OF ALL OTHER WARRANTIES, EX-
PRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED
WARRANTIES OF ANY KIND INCLUDING ANY WAR-
RANTIES OF MERCHANTABILITY OR FITNESS FOR
ANY PARTICULAR PURPOSE. THIS WARRANTY IS
LIMITED TO THE REPAIR OR REPLACEMENT OF
DEFECTIVE PARTS.
Equipment Alert
Up to 3 Trunk Lines can be installed per Central Scavenger Unit.
Trunk Lines can be up to 100 feet in overall length.
Up to eight 90° elbows can be placed in a Trunk Line.
Up to 4* Scavenging Hoses can be connected to a Trunk Line.
A Check Valve must be installed at every terminating end of a Trunk Line.
All Pipe should be mounted to a Wall or Ceiling and can be concealed inside walls if desired.
It is recommend the unit be turned off during close of business in order to extend longevity of system.
* Maximum of 3 Scavenging Lines per 100 foot Trunk Line in Canada.
© Midmark Corporation 2008
Adding Trunk Lines
PVC Inlet holes:
• The Scavenger Unit’s cabinet has 5 PVC Inlet holes to provide an array of possible
trunk line configurations. All holes are covered with plastic caps. Caps must remain in
place on all unused holes.
2 on Back
2 on Top
1 on Bottom
Sample Trunk Line Assembly
Scavenger Unit
Vacuum Inlet Assembly, installed with the Check
Valve facing downwards at the terminating end of
the Trunk Line.
3 feet
6 feet
8 feet 8 feet
14 feet
6 feet
14 feet
20 feet
20 feet
Scavenging
Hose
Scavenging
Hose
Scavenging
Hose
Scavenging
Hose
Midmark Corporation
60 Vista Drive
Versailles, OH 45380 USA
1-800-643-6275
1-937-526-3662
www.midmark.com
  • Page 1 1
  • Page 2 2

Midmark Scavenging Systems Product information

Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI