Electrolux 728404 (RH06RD1FL) Datasheet

Type
Datasheet
Technical Bulletin
file: technical bulletin
Identification:
Bulletin no:
Date:
Issuer:
Factory:
D02-D03-D04-D05-D06
CGX2003-11 (page 1 of 1), 2nd
24 May 2006
R. Sartor (Customer Support Dept.)
DW Vallenoncello - Italy
ELECTROLUX PROFESSIONAL SPA
DISHWASHING SYSTEMS PLATFORM POSTAL ADDRESS TELEPHONE TELEFAX
VALLENONCELLO FACTORY 33170 PORDENONE (ITALY) ++39 0434 380 650 ++39 0434 380 643
ISO 9001 - ISO 14001 CERTIFIED VIA SEGALUZZA, 30
Subject
Contactors in UC, FL, HT, PW and RT
Model
Undercounter double skin Marine versions (WT 38M), Frontal Loading (LS 7 /
WT 40), Hood Type (LS 9-10EA-14EA / WT 55-65E), Frontal Loading
Pot&Pan Washer (PW 1-2 / WT 830-850) ranges.
Reason
Suppliers standardization
Action in
Factory
Since serial nr. 32300001 we’ve introduced new contactors as follow:
OLD
The supplier’s model name gives the current rate for inductive loads (e.g. pumps)
Spare Part
Code
Supply rate
NEW
Spare Part
Code
Supplier’s
Model name
Inductive
current rate
Resistive
current rate
Where
048825 230V / 50Hz
0L0285
K3-10A01 10A 25A
WT 38M50
FL
HT
PW
048736 230V / 60Hz
0L0286
K3-10A01 10A 25A
WT 38M60
HT (60Hz)
PW (60Hz)
046994 24V / 50Hz
0L0360
K3-14A10 14A 25A
Old RT range
Old HAB/ADT
0E0177 24V / 50Hz
0L0361
K3-24A00 24A 50A
Old RT range
075796 230V / 50Hz
0L0354
K3-14A10 14A 25A
RT10/WT90
0W0690 § 230V / 50Hz
0L0355 §
K3-24A00 24A 50A
RT10/WT90
The supplier’s model name does NOT give the current rate for resistive
loads (e.g. tank and boiler heaters)!!!
Action in
Field
Most of new contactors are perfectly interchangeable towards previous ones.
Only the old contactor 0W0690 (see § above) has been replaced by contactor
0L0355 + auxiliary contact 046995. These 2 parts can be ordered together as
kit 0L0364.
The present modification/upgrade can be retrofitted but is not mandatory.
  • Page 1 1