A+ Corporation Avenger 38M Installation & Operation Instructions

Type
Installation & Operation Instructions
©2005 A+ Corporation, LLC. All rights reserved.
SCC-38M-InsInstallationOperation_100318
An ISO 9001:2008 certified company
Manufacturing Contact Information
A+ Corporation, LLC
41041 Black Bayou Rd.
Gonzales, LA 70737
Call for expert product application assistance:
Phone: (225)-644-5255 Website: www.geniefilters.com
Fax: (225)-644-3975 E-mail: sales@geniefilters.com
Safety Warnings
!
Tools Required
Avenger™ Model 38M
Installation & Operation Instructions
Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death.
} 

} 
} 
} Four #10 screws for mounting bracket to panel.
} Screwdriver for mounting bracket to panel.
©2005 A+ Corporation, LLC. All rights reserved.
SCC-38M-InsInstallationOperation_100318
An ISO 9001:2008 certified company
Technical Specications
Dimensions
Back View Side View
PORT D
3.700”
0.355”
1.250”
DIA.
3.256”
0.883”
3.700”
1.876”
2.626”
2.000”
2.625”
4.270”
4.995”
MINIMUM MAINTENANCE CLEARANCE 8.100”
OPTIONAL
MOUNTING
BRACKET
Technical Specifications
Maximum recommended
membrane flow rate
(For higher flow rates contact the factory)
Outside Diameter: ~ 1.4”
Inside Diameter: ~ 1.0”
Length: ~ 2.5”
Lowest possible pressure consistent with application
Machined parts: 316/316L stainless steel / NACE compliant
All other metal parts: stainless steel / NACE compliant
Sealing material: Fluoroelastomer standard
Membrane: inert
2,000 psig
1/4” female NPT
185˚F (85˚C) for Type 6 membrane
302˚F (150˚C) for Type 7 membrane
1,000 cc/min for Type 6 membrane
3,600 cc/min for Type 7 membrane
*Maximum flow results in approximately 2 psi membrane differential pressure
Maximum recommended
supply pressure
Port sizes
5
Number of ports
50 cc
Internal volume
Wetted materials
Maximum pressure rating
Element size
Maximum temperature
35 psig*
*Slowly open the supply pressure so that the minimum differential
pressure required to shut off the Liquid Block™ is not met or exceeded.
Maximum Liquid Block™
valve auto-reset pressure
©2005 A+ Corporation, LLC. All rights reserved.
SCC-38M-InsInstallationOperation_100318
An ISO 9001:2008 certified company
Installation Instructions
Install the mounting bracket onto the Avenger Model 33M or 38M as per the Mounting Bracket Installation Instructions included in A+
Corporation Mounting Bracket Kit P/N 33-509SS for Model 33M or P/N 38-509SS for Model 38M. Aftermarket brackets may be mounted
as per the mounting diagrams below. Mount the Avenger horizontally as shown in the diagram. Lock washers may be used on the lower 10-



Application Drawing
©2005 A+ Corporation, LLC. All rights reserved.
SCC-38M-InsInstallationOperation_100318
An ISO 9001:2008 certified company
Application Drawing
An ISO 9001:2008 certified company
Genie,
®
Avenger,
TM
Liquid Block
TM
and Genie
®
Membrane Technology
TM
are trademarks or registered
trademarks of A
+
C
orporation, LLC. All other referenced trademarks are the property of their respective owners.
Model Numbering & Additional Part Numbers
Model Numbering & Additional Part Numbers
How to build the model number:
How to build the replacement filter element number: How to build the replacement membrane kit number:
How to build the replacement o-ring kit number:
Your model number is determined by your specific needs. Choose options below.
Sealing material 0 = Fluoroelastomer 1 = Perfluoroelastomer (other materials available upon request)
Element type 07CFS = 0.1 micron coalescer fluorocarbon SS10 = 10 micron stainless steel
Membrane type 6 = Rejects ALL types of liquids from vapor 7= Rejects ONLY high surface tension liquids
Liquid Block™
Blank = No Liquid Block
L = Liquid Block
Mounting bracket accessory Part # 38-509SS (sold separately)
38M
3/2
S
Sealing material
Element type
Membrane type
Liquid Block option
Liquid Block option
Liquid Block option
30
5
5
Element type Membrane type
38M
5 0
38M
5 0
Sealing material
S
L
S
Replacement filter and membrane kits contain 5 each. O-ring replacement kit contains all assembly o-rings.
We cannot recommend specific sealing materials due to the complex nature of sample stream compositions. Temperature and pressure also may be factors. Unless specified otherwise, the product
will ship with our standard sealing materials and materials of construction stated in the technical specifications section of the corresponding Product Sheet.
Please refer to dupontelastomers.com for sealing material recommendations and advice. It is the user’s responsibility to specify the sealing materials of construction for their application.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

A+ Corporation Avenger 38M Installation & Operation Instructions

Type
Installation & Operation Instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI