Bauknecht TGZ 3570 IN Program Chart

Type
Program Chart
5019 419 66011/B
TGZ 3570 PRODUCT DESCRIPTION SHEET
NL
Operation of burners with
safety device and electric
ignition
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame and star
setting.
At the same time, hold the knob down
until the burner ignites.
After the burner has ignited, keep the knob
pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the
operations described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the
small flame setting.
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden
draught, an interruption in the gas
delivery, boiling over of liquids, etc.).
The separator panel, positioned beneath
the cooktop at a minimum distance of
20 mm, must be sealed.
1. Removable panstand grids
2-5. Medium burners
3-6. Large burners
4. Small burner
7. Control knob for front
left burner
8. Control knob for rear,
left burner
9. Control knob for
central burner
10. Control knob for rear,
right burner
11. Control knob for front
right burner
Symbols
Shaded
circle
Tap closed
Large
flame and
star
Maximum opening/
delivery and electric
ignition
Small
flame
Minimum opening or
reduced delivery
4gb66011b.fm Page 1 Monday, July 14, 2003 4:04 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and
680 mm, the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width
of the cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood
instructions, which specify the correct distance.
INJECTORS TABLE CATEGORY II2L3B/P
Type of gas used Type of
burner
Injector
marking
Rated
heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G25
large
medium
small
132
102
80
3.00
1.75
1.00
332 l/h
194 l/h
111 l/h
0.80
0.50
0.50
20 25 30
LIQUID
PETROLEUM GAS
(Cylinder) G30
large
medium
small
87
66
50
3.00
1.75
1.00
218 g/h
127 g/h
73 g/h
0.80
0.50
0.50
25 30 35
LIQUID
PETROLEUM GAS
(Cylinder) G31
large
medium
small
87
66
50
2.7
1.575
0.9
193 g/h
112 g/h
64 g/h
0.80
0.50
0.50
25 30 35
Type of gas
used
Appliance model Total rated heat
capacity
Pcs-kW
Total rated
consumption
Air required for
burning m
3
/h
G25 25 mbar 5 gas 10.5 1163 l/h 21
G30 30 mbar 5 gas 10.5 763 g/h 21
G31 30 mbar 5 gas 9.45 674 g/h 18.9
4gb66011b.fm Page 2 Monday, July 14, 2003 4:04 PM
  • Page 1 1
  • Page 2 2

Bauknecht TGZ 3570 IN Program Chart

Type
Program Chart

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI