Ignis AKF 619 IX Program Chart

Type
Program Chart

This manual is also suitable for

AKF 618 / AKF 619 PRODUCT DESCRIPTION SHEET
IT
5019 519 66008
Operation of burners with safety
device and electric ignition
To light one o the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught, an
interruption in the gas delivery, boiling over of
liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1.
Removable grids
2-5.
Medium burners
3.
Large burner
4.
Auxiliary burner
6.
Tr i p l e c r o w n b u r n e r
7.
Front left burner control knob
8.
Rear left burner control knob
9.
Central burner control knob
10.
Rear right burner control knob
11.
Front right burner control knob
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening or
reduced delivery
Insert a wooden panel at
least 20 mm thick under the
hob, at a distance of at least
15 mm from the cooking
hob bottom.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance “A” between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be at least 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
hob, the height “B” must be a minimum of 400 mm.
Before installing a hood above the hob please refer to the hood instructions,
which specify the correct distance.
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Typ e o f g as us ed Typ e o f
burner
Injector
marking
100/mm
Rated heat
capacity
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
triple crown
rapid
semi-rapid
auxiliary
141
129
101
77
3.50
3.00
1.75
1.00
333 l/h
286 l/h
167 l/h
95 l/h
1.50
0.80
0.50
0.50
17 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G30
triple crown
rapid
semi-rapid
auxiliary
94
87
66
50
3.50
3.00
1.75
1.00
254 g/h
218 g/h
127 g/h
73 g/h
1.50
0.80
0.50
0.50
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G31
triple crown
rapid
semi-rapid
auxiliary
94
87
66
50
3.50
3.00
1.75
1.00
254 g/h
218 g/h
127 g/h
73 g/h
1.50
0.80
0.50
0.50
25 37 45
Typ e of gas
used
Appliance model Total rated heat
capacity
kW
Total rated
consumption
Air necessary (m3)
for the combustion
of 1 m
3
of gas
G20 20 mbar 5 gas 11 1048 22
G30 28-30 mbar 5 gas 11 799 22
G31 37 mbar 5 gas 11 799 22
  • Page 1 1